• Title/Summary/Keyword: RT3D

Search Result 538, Processing Time 0.028 seconds

Radiation therapy for gastric mucosa-associated lymphoid tissue lymphoma: dose-volumetric analysis and its clinical implications

  • Lim, Hyeon Woo;Kim, Tae Hyun;Choi, Il Ju;Kim, Chan Gyoo;Lee, Jong Yeul;Cho, Soo Jeong;Eom, Hyeon Seok;Moon, Sung Ho;Kim, Dae Yong
    • Radiation Oncology Journal
    • /
    • v.34 no.3
    • /
    • pp.193-201
    • /
    • 2016
  • Purpose: To assess the clinical outcomes of radiotherapy (RT) using two-dimensional (2D) and three-dimensional conformal RT (3D-CRT) for patients with gastric mucosa-associated lymphoid tissue (MALT) lymphoma to evaluate the effectiveness of involved field RT with moderate-dose and to evaluate the benefit of 3D-CRT comparing with 2D-RT. Materials and Methods: Between July 2003 and March 2015, 33 patients with stage IE and IIE gastric MALT lymphoma received RT were analyzed. Of 33 patients, 17 patients (51.5%) were Helicobacter pylori (HP) negative and 16 patients (48.5%) were HP positive but refractory to HP eradication (HPE). The 2D-RT (n = 14) and 3D-CRT (n = 19) were performed and total dose was 30.6 Gy/17 fractions. Of 11 patients who RT planning data were available, dose-volumetric parameters between 2D-RT and 3D-CRT plans was compared. Results: All patients reached complete remission (CR) eventually and median time to CR was 3 months (range, 1 to 15 months). No local relapse occurred and one patient died with second primary malignancy. Tumor response, survival, and toxicity were not significantly different between 2D-RT and 3D-CRT (p > 0.05, each). In analysis for dose-volumetric parameters, $D_{max}$ and CI for PTV were significantly lower in 3D-CRT plans than 2D-RT plans (p < 0.05, each) and $D_{mean}$ and V15 for right kidney and $D_{mean}$ for left kidney were significantly lower in 3D-CRT than 2D-RT (p < 0.05, each). Conclusion: Our data suggested that involved field RT with moderate-dose for gastric MALT lymphoma could be promising and 3D-CRT could be considered to improve the target coverage and reduce radiation dose to the both kidneys.

Evaluation of Image Quality for 2D TSE(RT) and 3D GRASE in MRCP Study: Fast MRCP Method (췌담관자기공명영상에서 2D TSE(RT)와 3D GRASE(BH) 기법에 대한 영상의 질 평가 : Fast MRCP 기법)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.983-989
    • /
    • 2021
  • In this study, we intend to evaluate image quality and provide to clinical basic data by applying to 2D TSE (RT) and 3D GRASE (BH) techniques using Fast MRCP testing methods for application to patients in poor patient condition. Data were analyzed for 30 patients (15 males, 15 females, and 64±4.26 average age) who underwent MRCP tests. The equipment used was Ingenia CX 3.0 T equipment and Ds anterior coil was used for data acquisition. SNR and CNR of each image were measured through quantitative analysis, and the quality of the image was evaluated by dividing it into 5 grades for qualitative evaluation. The image evaluation was performed on the paired t-test and the Wilcoxon test, and when the p value was 0.05 or less, it was considered to be significant. As a result of quantitative analysis of SNR and CNR, 3D GRASE (BH) was measured high when comparing the two techniques, 2D TSE (RT) MRCP and 3D GRASE (BH) (p<0.05). The qualitative analysis result is a sharpness of the bile duct: 3D GRASE(BH): 4.12±0.03, Overall image quality: 3D GRASE(BH): 4.21±0.91 was high (p=0.001). The motion artifact of the bile duct showed no significant difference with two techniques(2D TSE(RT): 4.41±0.04, 3D GRASE(BH): 4.53±0.14(p=0.067). However, the background suppression obtained significant results with 2D TSE(RT) of 4.14±0.55(p=0.001). In conclusion, as a result of using the Fast MRCP testing method, MRCP images obtained by 3D GRASE (BH) had an advantage over MRCP images using 2D TSE (RT). However, there will be useful results of 2D TSE(RT) MRCP technique in patients who have difficulty holding their breath.

Analysis of the image composition speed of RT and TPSM algorithms (RT과 TPSM 알고리즘의 영상구성 속도 분석)

  • Jin-Seob Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.139-143
    • /
    • 2023
  • In this paper, compared to the RT algorithm that constitutes CT images, the TPSM algorithm available in the conical CB-CT system was applied to enable 3D CT image configuration faster than the existing RT, and the image speeds of the two algorithms were compared and analyzed. To this end, the TPSM algorithm available in the conical CB-CT system was applied to enable real-time processing in 3D CT image composition. As a result of the experiment, it was found that the cross-sectional image constructed using TPSM decreases the quality of the image slightly by empty pixels as the distance from the center point increases, but in the case of TPSM rotation-based methods, the image composition speed is far superior to that of the RT algorithm.

A Neutravidin-based Assay for Reverse Transcriptase Suitable for High Throughput Screening of Retroviral Activity

  • Brennan, Lyndall E.;Sune, Carlos;Klimkait, Thomas
    • BMB Reports
    • /
    • v.35 no.3
    • /
    • pp.262-266
    • /
    • 2002
  • A non-isotopic neutravidin-based reverse transcriptase (RT) assay adapted for high throughput screening of HIV activity is described. Using a 96-well microtitre plate, HIV particles are lysed and the RT enzyme released into a reaction mixture containing poly(A) RNA, biotinylated oligo d(T) and fluorescein-labelled dUTP (FI-dUTP). With poly(A) as a template and oligo d(T) as primer, the viron RT incorporates FI-dUTP into an elongating DNA strand. The resulting product is captured on a neutravidin-coated 96-well plate and the unincorporated nucleotides removed by a series of washing steps. A simple ELISA is subsequently performed using a monoclonal antifluorescein antibody conjugated to alkaline phosphatase. Quantification of RT activity is facilitated by a colorimetric readout. The assay was validated in the context of a diagnostic HIV-1 phenotyping assay. Using supernatants from HIV-1 infected lymphocyte cultures the assay was shown to be as sensitive as a radioactive assay and the RT activity correlated well with levels of cell-asociated HIV-p24. Importantly, even minor reductions of RT activity by virus variants with reduced fitness could be distinguished.

Evaluation of Biodegradation in an Aquifer Contaminated with Petroleum Hydrocarbon

  • 이지훈;이진용;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.120-123
    • /
    • 2001
  • To evaluate the biodegradability of contaminants in an aquifer, computer modeling with RT3D model (Clement, 1997) was used. The RT3D model simulates the biodegradation of organic contaminants using a number of aerobic and anaerobic electron acceptors. The RT3D model was applied to a well-studied petroleum hydrocarbon plume in a shallow unconfined aquifer in Uiwang, Korea. The results of this study demonstrate tile importance of biodegradation processes in the monitored natural attenuation and in reducing contaminant concentrations in a shallow aquifer. The modeling results tell that the amount of electron acceptors is the key factor affecting biodegradation of TEX, the petroleum hydrocarbon contaminant in shallow groundwater

  • PDF

Dosimetric comparison of axilla and groin radiotherapy techniques for high-risk and locally advanced skin cancer

  • Mattes, Malcolm D.;Zhou, Ying;Berry, Sean L.;Barker, Christopher A.
    • Radiation Oncology Journal
    • /
    • v.34 no.2
    • /
    • pp.145-155
    • /
    • 2016
  • Purpose: Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or volumetric-modulated arc therapy (VMAT) may improve radiation delivery to the target while avoiding organs at risk in the clinical context of skin cancer regional nodal irradiation. Materials and Methods: Twenty patients with locally advanced/high-risk skin cancers underwent computed tomography simulation. The relevant axilla or groin planning target volumes and organs at risk were delineated using standard definitions. Paired t-tests were used to compare the mean values of several dose-volumetric parameters for each of the 4 techniques. Results: In the axilla, the largest improvement for 3D-CRT compared to 2D-RT was for homogeneity index (13.9 vs. 54.3), at the expense of higher lung $V_{20}$ (28.0% vs. 12.6%). In the groin, the largest improvements for 3D-CRT compared to 2D-RT were for anorectum $D_{max}$ (13.6 vs. 38.9 Gy), bowel $D_{200cc}$ (7.3 vs. 23.1 Gy), femur $D_{50}$ (34.6 vs. 57.2 Gy), and genitalia $D_{max}$ (37.6 vs. 51.1 Gy). IMRT had further improvements compared to 3D-CRT for humerus $D_{mean}$ (16.9 vs. 22.4 Gy), brachial plexus $D_5$ (57.4 vs. 61.3 Gy), bladder $D_5$ (26.8 vs. 36.5 Gy), and femur $D_{50}$ (18.7 vs. 34.6 Gy). Fewer differences were observed between IMRT and VMAT. Conclusion: Compared to 2D-RT and 3D-CRT, IMRT and VMAT had dosimetric advantages in the treatment of nodal regions of skin cancer patients.

Three-Dimensional Net Shaping Combining $VLM-_{ST}$ and the Triple Reverse Rapid Tooling ($VLM-_{ST}$ 공정과 삼단역전 쾌속 툴링 공정을 이용한 3차원 제품 정형가공에 관한 연구)

  • 안동규;이상호;양동열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.428-432
    • /
    • 2003
  • The technical combination of RP and RT has a potential for rapid manufacturing of three-dimensional parts. In the present work a new RP system, $VLM-_{ST}$, is proposed to manufacture net shapes of 3D prototypes. ㅁ human head shape and a kob shape are manufactured by the $VLM-_{ST}$ apparatus. In addition, a new RT technology, which utilizes a RTV molding technique and a triple reverse process technique, is proposed to manufacture net shapes of 3D plastic parts using prototypes of $VLM-_{ST}$. A plastic part of the knob shape os produced by the proposed RT technology. The combination of the proposed RP and RT enables the manufacturing of a plastic knob within two days.

  • PDF

Investigation into Net-Shape Manufacturing of Three-Dimensional Parts by using RP and RT (쾌속 조형과 쾌속 툴링을 이용한 3차원 제품의 정형 가공에 관한 연구)

  • Ahn D. G.;Lee S. H.;Kim K. D.;Yang D. Y.;Park S. K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.05a
    • /
    • pp.16-19
    • /
    • 2001
  • Rapid Prototyping (RP) and Rapid Tooling (RT) were introduced to reduce time-to-market and cost by shortening not only the development phase but also the production phase of the manufacturing process. RP generally builds up a prototype layer by layer, rapidly generating a fully three-dimensional free form shape. RT enables the manufacture of production tools. The integration of RP and RT has the potential for rapid net shaping of thee-dimensional parts, which have geometrical complexity. In this study, net shaping techniques for making three-dimensional parts using RP and RT are described and a sample part are shown. A three-dimensional metal part is manufactured by a new RP process, Variable Lamination Manufacturing by using Expandable Polystyrene Foam (VLM-S), and its application to RT for making a clover punch. In addition, we discussed the technology fusion between metal forming md RP/RT.

  • PDF

Study on Rapid Manufacturing of 3D Functional Parts Combining VLM-ST Process and Its RT Technology (단속형 가변적층 쾌속조형공정과 쾌속툴링 기술을 이용한 쾌속 3차원 기능성 제품 개발에 관한 연구)

  • 안동규;이상호;김기돈;양동열
    • Transactions of Materials Processing
    • /
    • v.11 no.4
    • /
    • pp.323-331
    • /
    • 2002
  • The combination of rapid prototyping(RP) and rapid tooling(RT) has a potential for rapid manufacturing of three-dimensional parts. In the present study, a new RP system transfer type Variable Lamination Manufacturing using Expandable Polystyrene Foam (VLM-ST), is proposed to fabricate net shapes of three-dimensional prototypes. Various three-dimensional parts, such as a knob shape and a human head shape, are manufactured by the VLM-ST apparatus. In addition, a new rapid tooling technology, which utilizes a room temperature vulcanizing (RTV) molding technique and a triple reverse process technique, is proposed to manufacture net shapes of three-dimensional plastic parts using the prototypes of VLM-ST. A plastic part of the knob shape is produced by the proposed RT technology. The combination of the proposed RP and RT enables the manufacture of a plastic knob within two days.

An Analysis on the Real-Time Performance of the IGS RTS and Ultra-Rapid Products (IGS RTS와 Ultra Rapid 실시간 성능 분석)

  • Kim, Mingyu;Kim, Jeongrae
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • For real-time precise positioning, IGS provides ephemeris predictions (IGS ultra-rapid, IGU) and real-time ephemeris estimates (real-time service, RTS). Due to the RTS data latency, which ranges from 5 s to 30 s, a short-term prediction process is necessary before applying the RTS corrections. In this paper, the real-time performance of the RTS correction and IGU prediction are compared. The RTS correction availability for the GPS satellites observed in Korea is computed as 99.3%. The RTS correction is applied to broadcast ephemeris to verify the accuracy of the RTS correction. The 3D orbit RMS error of the RTS correction is 0.043 m. Prediction of the RTS correction is modeled as a polynomial, and then the predicted value is compared with the IGU prediction value. The RTS orbit prediction accuracy is nearly equivalent to the IGU prediction, but RTS clock prediction performance is 0.13 m better than the IGU prediction.