A study of multi protocol communication on single serial interface (Serial 전송라인에서 Multi-Protocol 통신의 구현 연구)

  • Lee, Jae-Cheol;Ko, Dae-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.5
    • /
    • pp.464-469
    • /
    • 2008
  • The RS-232C (Unbalanced serial) and RS-485 (balanced serial) are standard in serial communication. RS-485 uses a differential electrical signal, as opposed to unbalanced signals referenced to ground with the RS-232. Differential transmission, which uses two lines each for transmit and receive signal results in greater noise immunity and longer distances as compared to the RS-232C. The greater noise immunity and distance are big advantages in industrial environments. In general, one protocol on one serial interface is very normal application. In this study, we implemented multi protocols on one serial RS-485 interface and examine the performance and result with hanging multi equipments.

  • PDF

Design and Implementation of the JAVA Serial Communication Program to Control the Industrial Digital Indicator (산업용 디지털 지시계 제어를 위한 자바 시리얼 통신 프로그램의 설계와 구현)

  • Kim, Tai-Suk;Kim, Jong-Soo;Lee, Jung-Hwa
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.6
    • /
    • pp.794-801
    • /
    • 2011
  • Main machinery in the factory have various digital indicator to display its operating data for the manager. It is useful to control these datum at the remote office for factory automation in order to increase machine productivity. It is easy to use Ethernet infrastructure for remote communication. But most of all machinery in domestic factories still support RS232c or RS485 serial communication way. In this case to control machinery datum on the ethernet base, it is need to change RS232C or RS485 data to ethernet base. In this paper, in order to develop a remote progress management system through the wireless Internet, we show a design method to make easy maintenance by developing the system with both the JAVA language and RxTx Package for RS232c serial communication. For the system implementation, we added the digital indicator connect with a thermo couple to a machine which provide the real time status data of temperature. To connect machines management server program, we set up a convertor to change the RS485 data to the RS232c and also another convertor to change the RS232c data to wireless ethernet.

Multiple UART Communications Using CAN Bus (CAN 버스를 이용한 다중 UART 통신)

  • Kang, Tae-Wook;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1184-1187
    • /
    • 2020
  • This paper proposes an in-vehicle network controller fully exploiting the advantages of UART (Universal Asynchronous Receiver/Transmitter) and CAN (Controller Area Network). UART is used in 1-to-1 communication and it exploits parity bit for data integrity check. The proposed in-vehicle network controller converts UART into CAN, which enables multiple communications along with 1-to-1 communication. Also, the proposed in-vehicle network controller exploits CRC (cyclic redundancy check) for data integrity check, which increases communication reliability. CAN is controlled by microprocessor, but the proposed in-vehicle network controller can be controlled by any devices compliant with RS-232, RS-422, and RS-485.

A Development of CCTV Control System Based on Wireless Sensor Network (무선 센서 네트워크 기반 CCTV 제어 시스템 연구)

  • Cho, Soo-Hyung;Kim, Dae-Hwan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.219-220
    • /
    • 2009
  • Many surveillance cameras used in security system are controlled with RS-485 communication protocol. In this situation, if RS-485 connection can be replaced with wireless connection using sensor network technology, an installation will become ease because of no wired connection and also a deployment of cameras will become free. This paper explains about the design of wireless sensor node and the necessary implementation for an operation, which can be replacing RS-485 connection for the development of CCTV control system based on wireless sensor network. The hardware platform of sensor node was designed based on MicaZ and the software was developed based on TinyOS. To control surveillance cameras deployed on wide area, the supporting of multi-hop also was implemented. With the result of experiment deploying on real environment, it was revealed that the controller could control cameras quickly with wireless.

  • PDF

Interface Conversion to Extend Communication Cable of Ultrasonic Sensor (초음파 센서 통신선 연장을 위한 인터페이스 변환)

  • Seo, Dae-Il;Kwon, Byung-Hyuk;Kim, Sang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.467-472
    • /
    • 2022
  • The 3D ultrasonic anemometer transmits measured data by connecting PC and RS232C interface. Depending on the observation location, it is often necessary to extend the cable connecting the PC and the sensor. When installing on the test bed of the Air Meteorological Agency, the original AWM2919 cable was required to be extended because the distance between the PC container and the equipment installation site was more than 30 m. The cable was extended through a process such as extending the AWM2919 cable, converting the interface with the PC from RS232C to RS485, and testing the RS485 communication. After the equipment was installed with an extended cable, data were remotely collected and analyzed to confirm successful cable extension.

Development of Control System with Android Operation System for Dentistry Integrated Device (치과용 통합공급장치를 위한 안드로이드 운영체제가 내장된 제어시스템 개발)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.635-642
    • /
    • 2012
  • In this paper, a real-time control system with Wi-Fi wireless communication was developed for dentistry Integrated Device. The control system is developed based on the Android platform using S3C6410 ARM core that is equipped with Wi-Fi communication, RS-485, Linux 2.6 and Android 2.0. The control system controls a water purifier, compressor and suction in real-time. The experimental results that the control system was controlled by each control modules connected with a water purifier, compressor and suction. The status values are displayed in real-time using RS485.

Development of a Large Quantity of Inputs Interface System Using a Single Chip microcontroller (원칩 마이컴을 이용한 대용량 입력 인터페이스 시스템의 개발)

  • Park, Ju-Tae;Choi, Duck-sung;Jeong, Seung-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.215-221
    • /
    • 2016
  • In this thesis we introduce a large quantity of input interface system using a low cost single chip microcontroller which is consists of walking board with 1600 switches, RS485 communication for switch data communication and PC application software for walking pattern analysis. When a pedestrian walks on the walking board, the pattern analysis of foot pressed switches can be utilized on diverse divisions of sports and industry such as walking physical therapy, dancing, a large quantity of sensors interface system, etc.

Performance of Serial Communication Protocols through Conducting Threads (전도성사를 매체로 한 직렬 통신 프로토콜 성능)

  • Kim, Na-Young;Kim, Hwan;Kim, Juk-Young;Kwon, Young-Mi
    • Journal of Internet Computing and Services
    • /
    • v.12 no.5
    • /
    • pp.21-28
    • /
    • 2011
  • Recently medical and entertainment applications using conducting textile are suggested, but the data of conducting threads are not characterized, classified and verified. Only the data sheet published by manufacturing companies is available. Thus we need to verify the performances of the threading threads in communication. And we need a guideline if the existing communication protocols can be used for the conducting threads communication or the new specific communication protocols have to be developed for the communication. This paper classifies the characteristics of conducting threads made by domestic and overseas companies. Based on the criteria we classified conducting threads into three classes: class A, class B and class C. Further we carried out experiments to verify the adaptability of existing simple serial communication protocols such as RS232. Six different conducting threads are used in experiments and the length of each thread was 0.5m, 1m, 2m and 3m. The data transmission rate and error rate are collected and analyzed. RS485 is very prone to error due to static electricity from human and environment. So it may not be appropriate as long-distance communication protocol up to 12km which is possible in theory. RS232 shows stable and error-less data transmission ability even though every conducting thread didn’t show transmission capability over RS232. USB protocol shows high data rate transmission but the distance cannot be exceeded over 2m. Additionally, USB requires stable power supply. But if the power is supplied through conducting thread, its function is not.

Design of Industrial Communication Gateway Using Additive Layer Type Communication Module (적층형 통신 모듈을 이용한 산업용 통신 게이트웨이 설계)

  • Nam, Jae-Hyun;Eum, Sang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1673-1678
    • /
    • 2019
  • There are various networks and communication methods are used in industrial communication. Enterprises need to convert communications between industrial devices and networks for production line expansion, factory upgrades, network segmentation, and SI. This requires designers manufactured by many manufacturers to provide communication equipment for data or protocol conversion in order to connect and transmit various other mechanical devices to the network. This paper designed industrial communication gateway that can support the transformation of industrial communication protocol using multi-layered communication module. Industrial communication gateways have a structure that connects individual communication modules using RS485 communication to multiple layers. Each communication module consisted of analog and digital data card, LAN, and CAN-enabled card. The main board processor used Atmega micro-processor, and the RS485 slot was placed to have a multi-layer communication module structure. These additive layer type communication modules support analog and digital I/O functions and LAN and CAN for wide use in industrial communication control and monitoring.

Industrial Communication Gateway Design of Communications Module Additive layer type (통신 모듈 적층형 산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Nam, Jae Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.133-136
    • /
    • 2019
  • Recently, many industrial devices are facing protocol compatibility problems with external monitoring and control systems. This paper designed an industrial communication gateway that can support the transformation of industrial communication protocol using multi-layered communication module. Industrial communication gateways have a structure that connects individual communication modules using rs485 serial communication to multiple layers. Each communication module consisted of analog data card, a digital data card LAN, and a CAN-enabled card. The main board processor used Atmega micro-processor, and the rs485 serial slot was placed to have a multi-layer communication module structure. These additive layer type communication modules support analog and digital I/O functions and LAN and CAN for wide use in industrial communication control and monitoring.

  • PDF