• Title/Summary/Keyword: RS-422

Search Result 74, Processing Time 0.029 seconds

Design and Implementation of Progress Management System Using Swing Component Based on Internet (Swing 컴포넌트를 이용한 인터넷 기반 공정관리시스템 설계와 구현)

  • Kim, Tai-Suk;Kim, Jong-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1163-1170
    • /
    • 2010
  • In this paper, in order to develop a remote progress management system through the Internet, we show a design method to make easy maintenance by developing the system with both the JAVA language and GoF Design Patterns. For the system implementation, we added the RS232C and RS422/RS485 communication modules to PLC(Programmable Logic Controller) in the control box which provide the real time status data of machines. Also we set up the RS232C to Ethernet converter based on wireless environment to communicate the PLC control data. We use JAVA Swing components to implement the multi-tier architecture system supported the GUI of the Applet and Frame at the same time so that the manager grasps the progress of work easily at the remote machines through the Internet. The key objective of the multi-tier architecture is to share resources among clients, this proposed system can help to develop the software to control the remote machine, and also it has the advantage that developer who wants to make a similar software can make easy to add new function reusing the existing codes.

The implementation of Access Control System using Biometric System (Biometric System(fingerprint Reader)을 이용한 Access Control System 구현에 관한 연구)

  • 김광환;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.439-442
    • /
    • 2003
  • In this paper, a system that implementation of Access Control System Using Biometric System. Biometrics is science which deals with verifying or recognizing using physiological or behavioral characteristic Access Control System uses Biometric system to make an access control system. Biometrics goes under the study of bio-recognition or bio-measurement. It is a technology or study that identifies individuals using one's Biometric character. Access control system is a system used to identify one's entrance and exit, personal management, and security. Access control system can be joined with Biometric system to produce easier use and more sufficient effects. Access control system using Wiegand (Data Format) signal output, can replace earlier RF Card systems and make an access control (security) system. It uses RS-232, Rs-422 or TCP/IP type communication with the computer so an embedded system can be controlled using the software.

  • PDF

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 M모A 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2419-2422
    • /
    • 2010
  • The current marine internal communication systems are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. However, general vessel communication method have a weak point that must establish the extra private line. But, the power line communication has advantage over general vessel communication method as it uses AC220V/DC24V without changing line. Therefore, we will propose a new bridge based on the DC-PLC(power Line communication) technique which support the NMEA0183 protocol inside vessel network systems.

Implementation of Intelligent BNWAS and NMEA protocol Bridge Based on RlexRay (FlexRay 기반의 지능형 BNWAS 및 NMEA 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kim, Min;Byun, Gi-Sig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.183-186
    • /
    • 2010
  • This paper presents a stable real-time based FlexRay technology which is employed with a standard protocol of the marine electronic equipments and the bridge navigational watch alarm system (BNWAS). The traditional marine communications use NMEA communication protocols, and RS-232 and RS-422 techniques in the BNWAS, thus there are difficulty in seeking stability and reliability. To overcome such problems we utilize the FlexRay protocol technique to prevent data loss or error.

  • PDF

The implementation of Access Control System using Biometric System (생체인식 시스템을 이용한 Access Control System 구현에 관한 연구)

  • 김광환;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.494-498
    • /
    • 2004
  • In this paper, a system that implementation of Access Control System Using Biometric System. Biometries is science which deals with verifying or recognizing using physiological or behavioral characteristic Access Control System uses Bionietric system to make an access control system. Biometrics goes under the study of bio-recognition or bio-measurement. It is a technology or study that identifies individuals using one's Biometric character. Access control system is a system used to identify one's entrance and exit, personal management, and security. Access control system can be joined with Biometric system to produce easier use and more sufficient effects. Access control system using Weigand (Data format) signal output, can replace earlier RF Card systems and make an access control (security) system. It uses RS-232, Rs-422 or TCP/IP type communication with the computer so an embedded system can be controlled using the software.

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 NMEA 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.577-578
    • /
    • 2010
  • The current marine communication networks are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. This paper proposes a new bridge based on the DC power line communication technique supported from the NMEA0183 to design inside marine systems.

  • PDF

A study of multi protocol communication on single serial interface (Serial 전송라인에서 Multi-Protocol 통신의 구현 연구)

  • Lee, Jae-Cheol;Ko, Dae-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.5
    • /
    • pp.464-469
    • /
    • 2008
  • The RS-232C (Unbalanced serial) and RS-485 (balanced serial) are standard in serial communication. RS-485 uses a differential electrical signal, as opposed to unbalanced signals referenced to ground with the RS-232. Differential transmission, which uses two lines each for transmit and receive signal results in greater noise immunity and longer distances as compared to the RS-232C. The greater noise immunity and distance are big advantages in industrial environments. In general, one protocol on one serial interface is very normal application. In this study, we implemented multi protocols on one serial RS-485 interface and examine the performance and result with hanging multi equipments.

  • PDF

Developmetn of Integrated Monitoring System for Composition of CIM System's infrastructure(DLU & DAU) (l) (CIM 시스템의 Infrastructure(DLU & DAU) 구성을 위한 통합 모니터링 시스템의 개발(I))

  • Kang, H.W.;Lee, W.;Kim, S.B.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.18-24
    • /
    • 1995
  • This paper describes a multi-computer system developed for CIM(Computer Integrated Manufacturing) system, which combines single board computers and personal computers by using RS422/485 communication and LAN. The system adopts a concept of hot run back up system based on dual CUP system of host and supervisor structure. The dual CPU system and the single board computer are respectively developed using 32 bits microcomputer and 16 bits microprocessor. 8097BH. The multi communication between two types of system is done by using RS 422/485, and also data logging computers are linked with LAN.

  • PDF