• Title/Summary/Keyword: ROM-based

Search Result 348, Processing Time 0.025 seconds

Robust servo control of high speed optical disk drives (고속 광 디스크 드라이브의 강인 서보제어)

  • 임승철;정태영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.438-444
    • /
    • 1997
  • Recently, optical disk drives are increasingly demanded to have higher speed as well as high information density, especially for applications like CD-ROM drives. To this end, improvement of their optical pick-up structure and control is recognized the very challenging issue. In this paper, the 2-D motion of the pick-up is first analytically modelled to identify the cause and effect of the troublesome cross coupling between auto-focusing and tracking directions. Subsequently, the overall system equations are derived to include the dynamics of the related components in the auto-focusing servo system. While its unmeasurable parameters being estimated by the least square error method, a simple but decent linear model can be obtained within its operating frequency range. To design the high speed and robust positional servo controller, the design specifications are detailed and H$\sub$.inf./ control method is employed based on the simple model. Using the pickup in a commercial 8 fold speed CD-ROM drive as an example, performance of the designed controller is verified by realtime experiments.

  • PDF

Identifications and Reductions of Aerodynamic Noise Sources in High Speed Rotating CD-Rom Drive (고속으로 회전하는 CD-Rom 드라이브의 공력 소음원 규명 및 소음 저감)

  • Heo, Dae-Nyoung;Kim, Yong-Seok;Han, Seung-Jin;Kim, Young-Chan;Lee, Duck-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.771-776
    • /
    • 2000
  • Major noise source in high speed rotating CD-Rom drives arises due to the high-speed airflow produced from the upper and lower surfaces on the rotating disk. The present paper deals with the experimental approach how to identify the noise source based on the fundamental principles of aeroacoustics and to propose a reduction method of the noise source. Experimental studies were carried out in the anechoic wind tunnel with various design modifications, such as tray geometry and window size, to identify and reduce the major aerodynamic noise source and significant reductions of the noise source were obtained.

  • PDF

NUMERICAL SOLUTIONS OF BURGERS EQUATION BY REDUCED-ORDER MODELING BASED ON PSEUDO-SPECTRAL COLLOCATION METHOD

  • SEO, JEONG-KWEON;SHIN, BYEONG-CHUN
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.19 no.2
    • /
    • pp.123-135
    • /
    • 2015
  • In this paper, a reduced-order modeling(ROM) of Burgers equations is studied based on pseudo-spectral collocation method. A ROM basis is obtained by the proper orthogonal decomposition(POD). Crank-Nicolson scheme is applied in time discretization and the pseudo-spectral element collocation method is adopted to solve linearlized equation based on the Newton method in spatial discretization. We deliver POD-based algorithm and present some numerical experiments to show the efficiency of our proposed method.

Short-term Comparison of Supervised Rehabilitation and Home-based Rehabilitation for Earlier Recovery of Shoulder Motion, Pain, and Function after Rotator Cuff Repair

  • Song, Si-Jung;Jeong, Tae-Ho;Moon, Jung-Wha;Park, Han-Vit;Lee, Si Yung;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.15-21
    • /
    • 2018
  • Background: This study was undertaken to compare the outcome of supervised and home exercises with respect to range of motion (ROM), pain, and Single Assessment Numeric Evaluation (SANE). We further correlated the ROM recovery and pain reduction as well. Methods: The study included 49 patients who underwent arthroscopic rotator cuff repair. Rehabilitation was initiated after 4 weeks of immobilization. A total of 29 patients performed supervised exercise 3 times a week. Standardized education and brochures for review were provided to the remaining 20 patients who insisted on home rehabilitation. Statistical analysis was performed for comparing pain Numerical Rating Scale (NRS), SANE, and ROM. In addition, we also evaluated the correlation between pain and ROM. Results: Comparison of the two groups revealed no significant differences in forward flexion, internal rotation, abduction, and pain NRS. However, SANE at the 9th week (63.8 vs. 55.0, p=0.038) and improvement of external rotation from the 5th to the 9th week (17.6 vs. 9.3, p=0.018) were significantly higher in the supervised exercise group as compared to the home exercise group. Correlation of pain NRS with forward flexion, external rotation, internal rotation and abduction were statistically not significant (correlation coefficient=0.032 [p=0.828], -0.255 [p=0.077], 0.068 [p=0.642], and -0.188 [p=0.196], respectively). Conclusions: The supervised rehabilitation after arthroscopic rotator cuff repair showed better improvement in external rotation and higher SANE score after 4 weeks of rehabilitation exercise. However, no statistically significant correlation was observed between the recovery of ROM and short-term pain relief.

Is Adjacent Segment Disease More Frequent in Proximal Levels in Comparison with Distal Levels? Based on Radiological Data of at Least 2 Years Follow Up with More than 2 Level Thoracolumbar Fusions

  • Kim, Jung-Ho;Ryu, Dal-Sung;Yoon, Seung-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.603-609
    • /
    • 2019
  • Objective : The purpose of this retrospective study was to determine which of the proximal adjacent segment disease (ASD) and distal ASD was more prevalent and what parameters is more related to ASD in proximal levels and distal levels after more than 2 levels fusions. Methods : The medical records were reviewed retrospectively for 856 cases. A total of 66 cases of ASD were enrolled. On preop magnetic resonance imaging, disc degeneration was measured at the upper and lower parts of surgically treated levels and confirmed by the commonly used Pfirrmann grade. Segmental flexibility in sagittal plane was embodied in segment range of motion (ROM) obtained through flexion and extension X-ray before surgery. Coronal angle was recorded as methods Cobb's angle including fusion levels preoperatively. For the comparison of categorical variables between two independent groups, the chi-square test and Fisher exact test were performed. Results : Proximal ASD and distal ASD were 37/856 (4.32%) and 29/856 (3.39%), respectively. The incidence of proximal ASD was relatively high but insignificant differences. In comparison between ASD group and non ASD group, proximal Pfirmman was higher in proximal ASD and distal Pfirmman was higher in distal ASD group (p=0.005, p<0.008, respectively). However, in the ROM, proximal ROM was higher in proximal ASD, but distal ROM was not different between the two groups (p<0.0001, p=0.995, respectively). Coronal angle was not quite different in both groups (p=0.846). Conclusion : In spite of higher frequency in ASD in proximal level in spinal fusion, it is not clear that incidence of ASD in proximal level is not higher than that of distal ASD group in more than 2 level thoracolumbar fusions. Not only Pfirrmann grade but also proximal segmental ROM is risk factor for predicting the occurrence of ASD in patients more than 2 level of thoracolumbar spine fusion operation excluding L5S1.

Design of a Simple PCM Encoder Architecture Based on Programmable ROM (프로그래머블 ROM 기반의 심플 PCM 엔코더 설계)

  • Kim, Geon-Hee;Jin, Mi-Hyun;Kim, Bok-Ki
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.186-193
    • /
    • 2019
  • This paper presents and implements a simple programmable PCM encoder structure uisng the commutation method. In the telemetry system, information is required to assign each data to the channel in order to generate a frame format the data acpuired from the sensor. In this case, when the number of state information is large or the data type is various, there is a necessity to input a large amount of information to each channel. However, the more the number of channels and data, the more probability the error will occur. Therefore, in this paper, the channel information is created using the program. And PCM encoder was implemented to store channel information in ROM. The proposed PCM encoder architecture reduces the likelihood of errors. And it can improve the development speed. The validity of proposed structure is proved by simulation.

Development of a Test Strip Reader for a Lateral Flow Membrane-based Immunochromatographic Assay

  • Park, Je-Kyun;Kim, Suhyeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.127-131
    • /
    • 2004
  • A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochromatographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15mm. The performance of the strip reader was tested by analysis of HBV(hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample.

Development of Overhead Projector Films, CD-ROM, and Bio-Cosmos Home Page as Teaching Resources for High School Biology (고교 생물의 오버헤드 프로젝터용 필름 제작 및 전달 매체로서의 CD-ROM과 홈페이지의 설계)

  • Song, Bang-Ho;Sin, Youn-Uk;Choi, Mie-Sook;Park, Chang-Bo;Ahn, Na-Young;Kang, Jae-Seuk;Kim, Jeung-Hyun;Seo, Hae-Ae;Kwon, Duck-Kee;Sohn, Jong-Kyung;Chung, Hwa-Sook;Yang, Hong-Jun;Park, Sung-Ho
    • Journal of The Korean Association For Science Education
    • /
    • v.19 no.3
    • /
    • pp.428-440
    • /
    • 1999
  • The colorful overhead projector films, named as Bio-cosmos II, including photographs, pictures, concept maps, and diagrams, were developed and manufactured as audio-visual teaching aids and teaching resources for students' biology learning in high school, and the CD-ROM and web sites for their application to the school were also constructed. The content of the films was organized based upon the analysis of seven different biology textbooks approved by the Ministry of Education. The films were designated based on various instructional strategies and manufactured using multimedia with various educational softwares. The CD-ROM was composed of the scenes as logo, initial main, chapters list, contents, and quit. Initial main scene indicated various chapters according to the texts of biology areas in General Science, Biology I, and II. Each chapters linked with the scenes for detailed concept maps, the downstream real subjects, and contents. The subject screens were composed of various types of summarized diagrams including lesson contents, figures, pictures, photographs, and their explanation, experimental procedures and results, tables for summarized contents, and additional animation with video captures, explanations, glossary, etc. Most files were manufactured in software Adobe Photoshop by scanning the pictures, figures and photographs, and then the explanation, modification, storing with PICT or PSD files, and transformation with JPG files, were processed in the aspect of high quality in terms of instructional strategies and graphic skills on gracefulness, clearness, colorfulness, brightness, and distinctness. A 14 films for biology areas in General Science, 80 for Biology I, and 142 for Biology II were manufactured and loaded to the CD-ROM and web site, and the files had been attempted to opened with an internet home-page of http://gic.kyungpook.ac.kr/biocosmos.

  • PDF

A DST-3 BASED TRANSFORM KERNEL DERIVATION METHOD FOR DST-4 and DCT-4 IN VIDEO CODING (DST-4 와 DCT-4 를 위한 DST-3 기반 비디오 압축 변환 커널 유도 방법)

  • Shrestha, Sandeep;lee, Bumshik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.11a
    • /
    • pp.249-251
    • /
    • 2019
  • In the ongoing standardization of Versatile Video Coding (VVC), DCT-2, DST-7 and DCT-8 are designated as the vital primary transform kernels. Due to the effectiveness of DST-4 and DCT-4 in smaller resolution sequences, DST-4 and DCT-4 transform kernel can also be used as the replacement of the DST-7 and DCT-8 transform kernel respectively. While storing all of those transform kernels, ROM memory storage is considered as the major issue. So, to deal with this scenario, a unified DST-3 based transform kernel derivation method is proposed in this paper. The transform kernels used in this paper is DCT-2, DST-4 and DCT-4 transform kernels. The proposed ROM memory required to store the matrix elements is 1368 bytes each of 8-bit precision.

  • PDF

Implementation of an simulation-based digital twin for the plastic blow molding process (플라스틱 블로우몰딩 공정의 해석기반 디지털 트윈 구현)

  • Seok-Kwan Hong
    • Design & Manufacturing
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2023
  • Blow molding is a manufacturing process in which thermoplastic preforms are preheated and then pneumatically expanded within a mold to produce hollow products of various shapes. The two-step process, a type of blow molding method, requires the output of multiple infrared lamps to be adjusted individually, so the process of finding initial conditions hinders productivity. In this study, digital twin technology was applied to solve this problem. A blow molding simulation technique was established and simulation-based metadata was generated. A response surface ROM (Reduced Order Model) was built using the generated metadata. Then, a dynamic ROM was constructed using the results of 3D heat transfer analysis. Through this, users can quickly check the product wall thickness uniformity according to changes in the control value of the heating lamp for products of various shapes, and at the same time, check the temperature distribution of the preform in real time.