• Title/Summary/Keyword: ROM-based

Search Result 348, Processing Time 0.024 seconds

MASK ROM IP Design Using Printed CMOS Process Technology (Printed CMOS 공정기술을 이용한 MASK ROM 설계)

  • Jang, Ji-Hye;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.788-791
    • /
    • 2010
  • We design 64-bit ROM IP for RFID tag chips using printed CMOS non-volatile memory IP design technology for a printed CMOS process. The proposed 64-bit ROM circuit is using ETRI's $0.8{\mu}m$ CMOS porocess, and is expected to reduce process complexity and cost of RFID tag chips compared to that using a conventional silicon fabrication based on a complex lithography process because the poly layer in a gate terminal is using printing technology of imprint process. And a BL precharge circuit and a BL sense amplifier is not required for the designed cell circuit since it is composed of a transmission gate instead of an NMOS transistor of the conventional ROM circuit. Therefore an output datum is only driven by a DOUT buffer circuit. The Operation current and layout area of the designed ROM of 64 bits with an array of 8 rows and 8 columns using $0.8{\mu}m$ ROM process is $9.86{\mu}A$ and $379.6{\times}418.7{\mu}m^2$.

  • PDF

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

Differences in Story Comprehension: Children's Reading Levels and CD-ROM and Printed Storybooks (전자동화 및 인쇄동화 유형과 읽기 이해 수준에 따른 아동의 이야기 이해 차이)

  • Jeong, Jae-Hoo;Kim, Myoung Soon
    • Korean Journal of Child Studies
    • /
    • v.24 no.5
    • /
    • pp.15-26
    • /
    • 2003
  • In this study of children's story comprehension, 157 first grade students were randomly selected from 2 elementary schools. Based on their test scores on standardized reading comprehension test, 36 children in the upper and in the lower 25th percentiles were assigned to either a high or a low reading group. Children of both groups read the same story presented either by CD-ROM or by printed-book. Story comprehension was measured by retelling the story and by questions on comprehension. Data were analyzed by 2-way ANOVA. Results showed significantly higher comprehension scores in CD-Rom compared with the printed-book group. The difference in comprehension scores between the CD-ROM and the printed-book groups was greater than in the low reading group compared with the high reading group.

  • PDF

Effects of Limited Dorsiflexion Range of Motion on Movement Strategies during Landing (발등굽힘 관절가동범위 제한이 착지 시 움직임 전략에 미치는 영향)

  • Inje Lee;Donggun Kim;Hyeondeukje Kim;Hyunsol Shin;Jiwon Lee;Yujin Jang;Myeongwoo Pi
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.147-154
    • /
    • 2023
  • Objective: This study aimed 1) to compare the Landing Error Scoring System (LESS) score and movement patterns during landing of the lesser dorsiflexion range of motion (LDFROM) group to that with the greater dorsiflexion range of motion group, and 2) to identify the correlation between the weight-bearing dorsiflexion range of motion (WBDF ROM), LESS score, and movement patterns during landing. Method: Fifty health adults participated in this study. WBDF ROM was measured using the weight bearing lunge test while movement patterns during landing was assessed using the LESS. The joint angles of the ankle, knee and hip joints during landing were analyzed using the 2D video analysis. After mean value of WBDF ROM was calculated, participants were divided into two groups (GDFROM and LDFROM) based on the mean value. The Mann-Whiteny 𝒰 test was used to identify differences in movement strategies during landing between two groups and the Pearson's correlation analysis was performed to determine relationships between WBDF ROM and movement strategies. Results: The LDFROM group showed the poorer LESS score and stiffer landing kinematics during landing compared to the GDFROM group (p<0.05). In addition, DFROM was significantly related to the LESS score and landing kinematics (p<0.05) except for total hip excursion (p=0.228). Conclusion: Our main findings showed that the LDFROM group had poorer landing quality and stiffer landing movements compared to the GDFROM group. In addition, increase of WBDF ROM significantly improved landing quality and soft-landing movements. To reduce shock during landing such as ground reaction forces, individuals need to better utilize WBDF ROM and lower extremity movements based on our findings. Therefore, intervention programs for safer landings should include exercises that increase WBDF ROM and utilize eccentric contraction.

Comparison of Knee Muscle Strength and Ankle Dorsiflexion Range of Motion Between Standing Workers With and Without Patellofemoral Pain Syndrome

  • Weon, Young-soo;Ahn, Sun-hee;Kim, Jun-hee;Gwak, Gyeon-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2020
  • Background: Prolonged standing during work causes a lower extremity pain and disorders. Patellofemoral pain syndrome (PFPS) is one of the common diagnoses of the knee pain. Although the etiology of PFPS is not completely understood, it is considered to be multifactorial. Objects: The purpose of this study was to investigate difference in strength of knee muscles, quadriceps:hamstring muscles strength ratio (Q:H ratio), asymmetry ratio of knee muscles strength and dorsiflexion range of motion (ROM) between standing workers with and without PFPS. Methods: Twenty-eight standing workers with PFPS and 26 age-, height-, and weight-matched standing workers without PFPS participated in this study. A tension sensor measured knee muscle strength, and motion sensor measured dorsiflexion ROM. The asymmetry ratio of knee muscles was calculated by a specific formula using the knee muscles strength of the dominant side and the sound side. An independent t-test was used to identify significant differences in the strength, ROM, Q:H ratio, and asymmetry ratio between the PFPS and normal groups. Results: The standing worker with PFPS have significantly lower dorsiflexion ROM (p < 0.000) and higher asymmetry ratio of the hamstring muscles strength (p < 0.000) compare to the standing worker without PFPS. No significant differences were seen in the strength of quadriceps muscle and hamstring muscles, Q:H ratio, and asymmetry ratio of quadriceps muscle strength. Conclusion: There was a significant difference in the asymmetry ratio of the isometric hamstring muscle strength. This finding suggests that the asymmetry ratio of isometric hamstring muscle strength may be more important than measuring only the hamstring muscle strength of the PFPS side. Furthermore, the results of this study showed a significant difference in dorsiflexion ROM between the standing industrial workers with and without PFPS. Dorsiflexion ROM and isometric hamstring muscle strength should be considered when evaluating the subjects with PFPS.

Rotation Control of Shoulder Joint During Shoulder Internal Rotation: A Comparative Study of Individuals With and Without Restricted Range of Motion

  • Min-jeong Chang;Jun-hee Kim;Ui-jae Hwang;Il-kyu Ahn;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2024
  • Background: Limitations of shoulder range of motion (ROM), particularly shoulder internal rotation (SIR), are commonly associated with musculoskeletal disorders in both the general population and athletes. The limitation can result in connective tissue lesions such as superior labrum tears and symptoms such as rotator cuff tears and shoulder impingement syndrome. Maintaining the center of rotation of the glenohumeral joint during SIR can be challenging due to the compensatory scapulothoracic movement and anterior displacement of the humeral head. Therefore, observing the path of the instantaneous center of rotation (PICR) using the olecranon as a marker during SIR may provide valuable insights into understanding the dynamics of the shoulder joint. Objects: The aim of the study was to compare the displacement of the olecranon to measure the rotation control of the humeral head during SIR in individuals with and without restricted SIR ROM. Methods: Twenty-four participants with and without restricted SIR ROM participated in this study. The displacement of olecranon was measured during the shoulder internal rotation control test (SIRCT) using a Kinovea (ver. 0.8.15, Kinovea), the 2-dimensional marker tracking analysis system. An independent t-test was used to compare the horizontal and vertical displacement of the olecranon marker between individuals with and without restricted SIR ROM. The statistical significance was set at p < 0.05. Results: Vertical displacement of the olecranon was significantly greater in the restricted SIR group than in the control group (p < 0.05). However, no significant difference was observed in the horizontal displacement of the olecranon (p > 0.05). Conclusion: The findings of this study indicated that individuals with restricted SIR ROM had significantly greater vertical displacement of the olecranon. The results suggest that the limitation of SIR ROM may lead to difficulty in rotation control of the humeral head.

Comparison of Scapular Kinematics During Active Shoulder Horizontal Adduction Between Subjects With and Without Limited Range of Motion of Shoulder Horizontal Adduction

  • Joung, Ha-na;Kim, Moon-hwan;Jeon, In-cheol;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.68-75
    • /
    • 2016
  • Background: Shoulder horizontal adduction (HA) is performed in many activities of daily living. The limited range of motion (LROM) of HA is affected by the tightness of the posterior deltoid, infraspinatus, teres major, and posterior capsule of glenohumeral joint. The LROM of shoulder HA contributes to excessive scapular abduction. Objects: The aim of this study is to compare the scapular abduction distance and three-dimensional displacement of the scapula during shoulder horizontal adduction between subjects with and without the LROM of shoulder HA. Methods: 24 subjects (12 people in LROM group and 12 people in normal ROM group) participated. Subjects with less than $115^{\circ}$ of HA ROM were included in LROM group. Shoulder HA was performed 3 times for measuring scapular abduction distance and three-dimensional displacement of the scapula. Tape measure was used for measuring scapular abduction distance. Scapular abduction distance was normalized by dividing the scapular size. Polhemus Liberty was used for measuring the three-dimensional displacement of the scapula. Results: Normalized scapular abduction distance was significantly greater in LROM group than normal ROM group (p<.001). Three-dimensional displacement of the scapula during shoulder HA was greater in LROM group than normal ROM group (p<.05). Conclusion: LROM group had a greater scapular abduction and three-dimensional displacement of the scapula during shoulder HA compared to normal ROM group.

Multiple-Section Using 3D Spline based Cut-Scene Effect (3차 곡선을 이용한 다 구간 경로 기반의 컷씬 효과)

  • Sun, Bok-Gun;Shin, Young-Seo;Park, Sung-Jun
    • Journal of Korea Game Society
    • /
    • v.11 no.1
    • /
    • pp.93-100
    • /
    • 2011
  • Cinematic camera techniques are being increasingly applied to the game development these days. In this study, the object movement and camera effect for the game development using the curve in the 3D space were discussed. The Catmull-Rom spline algorithm follows the curve more closely than the other curve algorithms. With the algorithm proposed in this study, the Catmull-Rom spline was dynamically created according to the user's input in multiple sections in the 3D space, and objects smoothly passed along the route. In addition, Cut-Scene section is specified using the Catmull-Rom spline and the object movement can be observed. The results of the study on the accuracy and efficiency of the curve showed that the Catmull-Rom spline is very efficient not only for the object movement but also for the cinematic camera technique.

The Effect of Patellar Inferior Gliding on Knee Flexion Range of Motion in Individuals With Rectus Femoris Tightness

  • Kim, Jun-hee;Kim, Moon-hwan;Jeon, In-cheol;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.23 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • Background: Various methods are used for recovery of knee flexion range of motion (ROM) due to a tightened rectus femoris muscle (RFM) or limited inferior glide of the patella. Stretching methods are common interventions for restoring the tightened RFM length. Also patellar inferior gliding (PIG) technique can recover tightened RFM length too. However, effect of applying the PIG to passive knee flexion (PKF) has not been studied. Objects: The purpose of this study was to investigate the effect of combining PIG with RFM stretching for improving knee flexion ROM in subjects with RFM tightness. Methods: Twenty-six subjects with RFM tightness were recruited. Two different methods of knee stretching were tested: 1) PKF during modified Thomas test (MTT) and 2) PKF with PIG during MTT. The passive stretching forces was controlled by hand-held dynamometer. The knee flexion ROM angle was measured by a MTT with ImageJ software. Differences between the conditions with and without PIG were identified with a paired t-test. Results: The knee flexion ROM was significantly greater for PKF with PIG ($114.44{\pm}9.33$) than for PKF alone ($108.97{\pm}9.42$) (p<.001). Conclusion: A combination of passive knee flexion exercise and PIG can be more effective than PKF in increasing knee flexion ROM in individuals with RFM tightness.

Highlights of the 2023 Bethesda System for Reporting Thyroid Cytopathology, 3rd Edition (갑상선 세침흡인세포검사 2023년 베데스다 시스템, 3판의 하이라이트)

  • Dong Eun Song
    • Korean Journal of Head & Neck Oncology
    • /
    • v.40 no.1
    • /
    • pp.1-5
    • /
    • 2024
  • The Bethesda System for Reporting Thyroid Cytopathology (TBSRCT) is crucial for cytopathologists to use a standardized, category-based reporting system for thyroid fine needle aspirations and is effective for clear communication with the referring physicians. The new Bethesda System for Reporting Thyroid Cytopathology, the third edition in 2023, provides several key updates. The most important update is the assignment of only single name for each of the six diagnostic categories: (I) nondiagnostic; (II) benign; (III) atypia of undetermined significance; (IV) follicular neoplasm; (V) suspicious for malignancy; and (VI) malignant. An implied risk of malignancy (ROM) for each of six categories has been updated based on extensively published data since the second edition of TBSRTC in 2017 and offers both an average ROM for each category and the expected range of cancer risk. Estimated final ROM after excluding "Noninvasive Follicular Thyroid Neoplasm with Papillary Like Nuclear Features (NIFTP)" for each of six categories has been updated based on the reported mean decreases in the ROM if excluding NIFTP. For atypia of undetermined significance (AUS) category, the subcategorization is simplified and more formalized into 2 subgroups, AUS-nuclear atypia or AUS-other, based on the implied ROM and molecular profiling. For the pediatric thyroid disease, pediatric ROMs and management algorithms are newly added for the same six reporting categories for this age group. New or revised disease nomenclatures including high-grade follicular-derived carcinoma has been updated according to the recently published 2022 World Health Organization Classification of Thyroid Neoplasms. Brand new two chapters are added including clinical perspectives and imaging studies (Chap. 13) and the use of molecular and other ancillary tests (Chap. 14). The atlas is updated with new images to illustrate more effectively for new disease entity and diagnostic criteria.