• Title/Summary/Keyword: ROM-based

Search Result 350, Processing Time 0.027 seconds

An 1.2V 8-bit 800MSPS CMOS A/D Converter with an Odd Number of Folding Block (홀수개의 폴딩 블록으로 구현된 1.2V 8-bit 800MSPS CMOS A/D 변환기)

  • Lee, Dong-Heon;Moon, Jun-Ho;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.61-69
    • /
    • 2010
  • In this paper, an 1.2V 8b 800MSPS A/D Converter(ADC) with an odd number of folding block to overcome the asymmetrical boundary-condition error is described. The architecture of the proposed ADC is based on a cascaded folding architecture using resistive interpolation technique for low power consumption and high input frequency. The ADC employs a novel odd folding block to improve the distortion of signal linearity and to reduce the offset errors. In the digital block, furthermore, we use a ROM encoder to convert a none-$2^n$-period code into the binary code. The chip has been fabricated with an $0.13{\mu}m$ 1P6M CMOS technology. The effective chip area is $870{\mu}m\times980{\mu}m$. SNDR is 44.84dB (ENOB 7.15bit) and SFDR is 52.17dBc, when the input frequency is 10MHz at sampling frequency of 800MHz.

A Randomized Comparative Study of Blind versus Ultrasound Guided Glenohumeral Joint Injection of Corticosteroids for Treatment of Shoulder Stiffness

  • Lee, Hyo-Jin;Ok, Ji-Hoon;Park, In;Bae, Sung-Ho;Kim, Sung-Eun;Shin, Dong-Jin;Kim, Yang-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.120-127
    • /
    • 2015
  • Background: We prospectively compared the response to blind and ultrasound-guided glenohumeral injection of corticosteroids for treatment of shoulder stiffness. Methods: A total of 77 patients with shoulder stiffness between April 2008 and March 2012 were recruited. Patients were randomized to receive either a blind (group 1, n=39) or ultrasound-guided (group 2, n=38) glenohumeral injection of 40 mg triamcinolone. The clinical outcomes and shoulder range of motion (ROM) before injection, at 3, 6, and 12 months after injection and at the last follow-up were assessed. The same rehabilitation program was applied in both groups during the follow-up period. Results: There was no significant difference in demographic data on age, sex, ROM, and symptom duration before injection between groups (p>0.05). There were no significant differences in ROM including forward flexion, external rotation at the side, external rotation at $90^{\circ}$ abduction, and internal rotation, visual analogue scale for pain and functional outcomes including American Shoulder and Elbow Surgeons score, Simple Shoulder test between the two groups at any time point (p>0.05). Conclusions: Based on the current data, the result of ultrasound-guided glenohumeral injection was not superior to that of blind injection in the treatment of shoulder stiffness. We suggest that ultrasound-guided glenohumeral injection could be performed according to the patient's compliance and the surgeon's preference. Once familiar with the non-imaging-guided glenohumeral injection, it is an efficient and reliable method for the experienced surgeon. Ultrasound could be performed according to the surgeon's preference.

The Effect of Shoe Heel Types and Gait Speeds on Knee Joint Angle in Healthy Young Women - A Preliminary Study

  • Chhoeum, Vantha;Wang, Changwon;Jang, Seungwan;Min, Se Dong;Kim, Young;Choi, Min-Hyung
    • Journal of Internet Computing and Services
    • /
    • v.21 no.6
    • /
    • pp.41-50
    • /
    • 2020
  • The consequences of wearing high heels can be different according to the heel height, gait speed, shoe design, heel base area, and shoe size. This study aimed to focus on the knee extension and flexion range of motion (ROM) during gait, which were challenged by wearing five different shoe heel types and two different self-selected gait speeds (comfortable and fast) as experimental conditions. Measurement standards of knee extension and flexion ROM were individually calibrated at the time of heel strike, mid-stance, toe-off, and stance phase based on the 2-minute video recordings of each gait condition. Seven healthy young women (20.7 ± 0.8 years) participated and they were asked to walk on a treadmill wearing the five given shoes at a self-selected comfortable speed (average of 2.4 ± 0.3 km/h) and a fast speed (average of 5.1 ± 0.2 km/h) in a random order. All of the shoes were in size 23.5 cm. Three of the given shoes were 9.0 cm in height, the other two were flat shoes and sneakers. A motion capture software (Kinovea 0.8.27) was used to measure the kinematic data; changes in the knee angles during each gait. During fast speed gait, the knee extension angles at heel strike and mid-stance were significantly decreased in all of the 3 high heels (p<0.05). The results revealed that fast gait speed causes knee flexion angle to significantly increase at toe-off in all five types of shoes. However, there was a significant difference in both the knee flexion and extension angles when the gait in stiletto heels and flat shoes were compared in fast gait condition (p<0.05). This showed that walking fast in high heels leads to abnormal knee ROM and thus can cause damages to the knee joints. The findings in this preliminary study can be a basis for future studies on the kinematic changes in the lower extremity during gait and for the analysis of causes and preventive methods for musculoskeletal injuries related to wearing high heels.

The Effect of Spiral Balance Taping on Postoperative Sequelae in Breast Cancer : Case study (스파이랄 발란스 테이핑이 유방암 환자의 수술 후 후유증에 미치는 영향 : 사례연구)

  • Su-Ji Kang;Dae-Hee Lee;Cheul Jang;Back-Vin Lim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose : Cancer survivors often suffer from postoperative sequelae. the diagnosing and provision of manual therapy using spiral taping significantly improves the quality of life of cancer patients. The aim of this case study is to investigate the immediate effects of spiral taping on pain, range of motion (ROM), chemotherapy-induced peripheral neuropathy (CIPN), and lymphedema following breast cancer surgery. Methods : The taping techniques were performed as follows by spiral taping. The measurements were taken before, in the middle, and after taping using a mobile phone camera, tape measure, and a numerical rating score (NRS). The evaluation employed a single-group pre-post design based on a primitive experimental design. Results : Out of four patients, all four exhibited Reverse circle flow energy (RCFE), Passive cervical right (Rt) rotation test, anterior-posterior movement pattern, nerve type (+), cold energy (CE), sangcho acupuncture point, blood clot, hwal point. Comparing before and after treatment, almost all values were reduced to zero after treatment in terms of pain complaints. The lack of range of motion (ROM) caused by the shortened tissue after surgery did not increase. The range of motion (ROM) lost due to pain returned to normal. The circumference of lymphedema did not show a tendency. The symptoms of CIPN improved. Conclusion : There was a significant change in joint range of motion, with pain decreasing, but there were structural limitations in the tissue due to total resection, and the chemotherapy-induced peripheral neuropathy scale. It was effectively treated surgical site pain, axillary membrane syndrome-induced pain, and unexplained pain. While there was a treatment effect for lymphedema in the evaluation of circumference values, there was no significant change in circumference. There was a significant effect on chemotherapy-induced peripheral neuropathy, particularly in treating numbness in the feet, which is a side effect of TC anticancer drugs. This case study found that spiral balance taping provides a rapid therapeutic effect for most side effects in patients who have undergone total breast cancer resection. However, the generalization is limited due to the small sample size, and further research is needed to determine the extent to which the effects of one treatment are maintained.

Development and Tree-Dimensional Kinematic Analysis of the Dual Chamber-based Drinking Aid for Stroke Patients: A Prospective Pilot Study (이중 체임버 구조가 내장된 뇌졸중 환자용 컵의 개발과 3차원 동작분석을 통한 운동 형상학적 유용성 검증: 전향적 예비연구)

  • Heo, Seo Yoon;Kim, Kyeong-Mi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.180-190
    • /
    • 2016
  • This prospective pilot clinical trial mainly focuses on developing dual chamber-based assistive cups which are suitable for stroke patients who have struggled with using there affected arms. It is unable to provide motor and sensory enhancement during drinking activities and to examine the feasibility of the devices for acute phase, even for chronic stroke survivors. The stroke patients(n=16; male=8, female=8), in this trial, were provided informed consent to the investigation. All the individuals participated in 1 weeks of training for using cups, randomized over dedicated dual chamber based assistive cups(DC) or placebo-cups(PC) training. All the participants were assessed within 1 week before and after the intervention period. 3-dimensional motion analysis, sEMG(surface electromyography) and 3-dimensional trunk movement were assessed. The result presents DC data group compared with PC showed, they needed lesser ROM(range of motion) at the phase of drinking in shoulder movements and lesser muscle activities on upper trapezius, deltoid middle fiber and triceps brachii muscles, lesser tilting movement on front and back side in drinking phase, the differences were statistically significant(p<.05). Dual chamber-based assistive cup could be one of efficient way to complete ADLs(activities of daily living), especially drinking tasks, and these evidence data may contribute to determine certain rehabilitation policies related to assistive devise usage.

Adaptive Weighted Mean Filter to Remove Impulse Noise in Images (영상에서 임펄스 잡음제거를 위한 적응력 있는 가중 평균 필터)

  • Lee, Jun-Hee;Choi, Eo-Bin;Lee, Won-Yeol;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.2
    • /
    • pp.233-245
    • /
    • 2008
  • In this work, a new adaptive weighted mean filter is proposed for preserving image details while effectively suppressing impulse noise. The proposed filter is based on a noise pixel detection-estimation strategy. All the pixels are first detected using an impulse noise detector. Then the detected noise pixels are replaced with the output of the weighted mean filter over adaptive working window according to the rate of corrupted neighborhood pixels, while noise-free pixels are left unaltered. We compare the proposed filter to other existing filters in the qualitative measure and quantitative measures such as PSNR and MAE as well as computation time to verify the capability of the proposed filter. Extensive simulations show that the proposed filter performs better than other filters in impulse noise suppression and detail preservation without increasing of running time.

Measurement System for Phosphor Dispensing Shape of LED Chip Package Using Machine Vision (머신비전에 의한 LED Chip Package 형광물질 토출형상 측정)

  • Ha, Seok-Jae;Kim, Jong-Su;Cho, Myeong-Woo;Choi, Jong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2113-2120
    • /
    • 2013
  • In this study, an efficient machine vision based inspection system is developed for the in-line measurement of phosphor resin dispensing shapes on LED chip package. Since the phosphor resin (target material) has semitransparent characteristics, illuminated light beam is reflected from the bottom of the chip as well as from the surface. Since such phenomenon can deteriorate inspection reliability, a white LED and a 635nm laser slit beams are experimentally tested to decide suitable illumination optics. Also, specular and diffuse reflection methods are tested to decide suitable optical triangulation. As a result, it can be known that the combination of a white slit beam source and specular reflection method show the best inspection results. The Catmull-Rom spline interpolation is applied to the obtained data to form smoother surface. From the results, it can be conclude that the developed system can be sucessfully applied to the in-line inspection of LED chip packaging process.

Hardware Design of Arccosine Function for Mobile Vector Graphics Processor (모바일 벡터 그래픽 프로세서용 역코사인 함수의 하드웨어 설계)

  • Choi, Byeong-Yoon;Lee, Jong-Hyoung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.727-736
    • /
    • 2009
  • In this paper, the $arccos(cos^{-1})$ arithmetic unit for mobile graphics accelerator is designed. The mobile vector graphics applications need tight area, execution time, power dissipation, and accuracy constraints compared to desktop PC applications. The designed processor adopts 2nd-order polynomial approximation scheme based on IEEE floating point data format to satisfy speed and accuracy conditions and reduces area via hardware sharing structure. The arccosine processor consists of 15,280 gates and its estimated operating frequency is about 125Mhz at operating condition of $0.35{\mu}m$ CMOS technology. Because the processor can execute arccosine function within 7 clock cycles, it has about 17 MOPS(million arccos operations per second) execution rate and can be applicable to mobile OpenVG processor. And because of its flexible architecture, it can be applicable to the various transcendental functions such as exponential, trigonometric and logarithmic functions via replacement of ROM and minor hardware modification.

Clinical Usefulness of M-test on Patients with Chronic Neck Pain: A Single Arm Pre-post Comparison Study (M-test에 근거한 만성 경항통 환자의 진단 및 치료: 전후비교 임상연구)

  • Cho, Woo-Young;Chung, Seok-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.4
    • /
    • pp.67-75
    • /
    • 2016
  • Objectives The purpose of this study was to investigate the clinical usefulness of M-test (Meridian test) as an adjunctive evaluation and treatment in patients with chronic neck pain. Methods This study was a single arm pre-post comparison study. Thirty-six eligible subjects with chronic neck pain were recruited from August to September, 2015. M-test was used for evaluating the condition of meridian, which can induce the limitation of ROM and body discomfort. Subjects were offered intradermal acupuncture treatment on one-acupoint for 48 hours. Cervical numeric rating scale (NRS), cervical range of motion (ROM), neck disability index (NDI) and surface electromyography (SEMG) were measured before and after the treatment. Total NRS and the number of movement limitation of M-test were also measured before and after the treatment. Results Among the 36 participating subjects, 4 subjects were lost to follow-up or excluded in accordance with the criteria. Significant differences on Cervical NRS and NDI were found after the treatment (p<0.001). There was a significant difference in the range of left cervical rotation (p<0.05). Root mean square (RMS) of SEMG significantly decreased on the right sternocleidomastoid muscle (p<0.05), but significantly increased on the right trapezius muscle (p<0.05). Median frequency (MdF) of SEMG significantly increased on both sternocleidomastoid muscles. There appears to be significant differences after the treatment in total NRS and the number of movement limitation of M-test (p<0.05). Conclusions These results suggest that the evaluation and treatment of M-test based on the meridian and collateral theory were effective on cervical NRS and NDI, and also improved the movability of human body.

ANALYSIS OF EIGEN VALUES FOR EFFECTIVE CHOICE OF SNAPSHOT DATA IN PROPER ORTHOGONAL DECOMPOSITION (적합직교분해 기법에서의 효율적인 스냅샷 선정을 위한 고유값 분석)

  • Kang, H.M.;Jun, S.O.;Yee, K.
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.59-66
    • /
    • 2017
  • The guideline of selecting the number of snapshot dataset, $N_s$ in proper orthogonal decomposition(POD) was presented via the analysis of Eigen values based on the singular value decomposition(SVD). In POD, snapshot datasets from the solutions of Euler or Navier-Stokes equations are utilized to SVD and a reduced order model(ROM) is constructed as the combination of Eigen vectors. The ROM is subsequently applied to reconstruct the flowfield data with new set of flow conditions, thereby enhancing the computational efficiency. The overall computational efficiency and accuracy of POD is dependent on the number of snapshot dataset; however, there is no reliable guideline of determining $N_s$. In order to resolve this problem, the order of maximum to minimum Eigen value ratio, O(R) from SVD was analyzed and presented for the decision of $N_s$; in case of steady flow, $N_s$ should be determined to make O(R) be $10^9$. For unsteady flow, $N_s$ should be increased to make O(R) be $10^{11\sim12}$. This strategy of selecting the snapshot dataset was applied to two dimensional NACA0012 airfoil and vortex flow problems including steady and unsteady cases and the numerical accuracies according to $N_s$ and O(R) were discussed.