• Title/Summary/Keyword: ROM data

Search Result 377, Processing Time 0.029 seconds

DSP Implementation of Speech Enhancement System Using Microphone Array with Adaptive Post-processing (적응 후처리 과정을 갖는 마이크로폰 배열을 이용한 잡음제거기의 DSP 구현)

  • 권홍석;김시호;배건성
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.413-416
    • /
    • 2002
  • In this paper, a speech enhancement system using microphone array with adaptive Post-Processing is implemented in real-lime with TMS320C6201 DSP. It consists of delay-and-sum beamformer and adaptive post-processing filters with NLMS (Normalized Least Mean Square) algorithm. THS1206 ADC is used for collection of 4-channel microphone signals. Sizes of program memory, data ROM and data RAM of the implemented system are 15,744, 748 and 47,540 bytes, respectively. Finally 21.839${\times}$106 clocks per second is required for real-time operation.

  • PDF

$\alpha$ Scaling Parameter Optimization On Watermarking Using Autostereogram (오토스테레오그램을 이용한 워터마킹에서 $\alpha$스켈링 파라미터 최적화)

  • 허덕규;이인정;김성옥
    • Journal of Internet Computing and Services
    • /
    • v.2 no.4
    • /
    • pp.101-109
    • /
    • 2001
  • In recent year, the use of digital picture information and general picture information has been increased, However, numerous copyright infringement and pirate copy of picture information through Internet and CD-ROM happen very often, As a result, several methods of watermarking have been presented to solve and verify distortion of the original data, In addition, watermark data have been suggested to resolve the vastness of the original data, Watermarking methods are often used to protect the right of ownership of a copyright, However, these Watermarking methods have brought the obscurity of recognition caused by the complexity of verification procedure and the increase of magnitude computation occurrence, This paper mainly mentions about the local optimization of scaling parameter, the maximization of hiding of Watermark information and maximization of watermark information in case of restoration that determine the amount of inserted information which is used for preventing distortion and transformation of the original data caused by insertion and hiding of Watermark information on compounding Autostereogram into JPEG picture information.

  • PDF

Comparative Analysis of Gait Parameters and Symmetry between Preferred Walking Speed and Walking Speed by using the Froude Number

  • Yoo, Si-Hyun;Kim, Jong-Bin;Ryu, Ji-Seon;Yoon, Suk-Hoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.221-228
    • /
    • 2016
  • Objective: The purpose of this study was to investigate differences in gait parameters and symmetry between walking speed by using the Froude number and preferred walking speed. Method: Fifty adults (age: $21.0{\pm}1.7years$, body weight: $71.0{\pm}9.2kg$, height: $1.75{\pm}0.07m$, leg length: $0.89{\pm}0.05m$) participated in this study. Leg length-applied walking speed was calculated by using the Froude number, defined as Fr = ${\upsilon}^2$/gL, where v is the velocity, g is the gravitational acceleration, and L is the leg length. Video data were collected by using eight infrared cameras (Oqus 300, Qualysis, Sweden) and the Qualisys Track Manager software (Qualisys, Sweden), with a 200-Hz sampling frequency during two-speed walking (preferred walking speed [PS] and leg length-applied walking speed [LS]) on a treadmill (Instrumented Treadmill, Bertec, USA). The step length, stride length, support percentage, cadence, lower joint angle, range of motion (ROM), and symmetry index were then calculated by using the Matlab R2009a software. Results: Step and stride lengths were greater in LS than in PS (p < 0.05). The right single-support percentage was greater in LS than in PS (p < 0.05). The hip joint angle at heel contact and toe-off were greater in LS than in PS (p < 0.05). The hip and knee joint ROM were greater in LS than in PS (p < 0.05). Conclusion: Based on our findings, we suggest that increased walking speed had a significant effect on step length, stride length, support percentage, and lower joint ROM.

The Creation of Dental Radiology Multimedia Electronic Textbook (멀티미디어기술을 이용한 치과방사선학 전자 교과서 제작에 관한 연구)

  • Kim Eun-Kyung;Cha Sang-Yun;Han Won-Jeong;Hong Byeong-Hee
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.55-62
    • /
    • 2000
  • Purpose: This study was performed to develop the electronic textbook (CD-rom title) about preclinical practice of oral and maxillofacial radiology, using multimedia technology with interactive environment. Materials and Methods: After comparing the three authoring methods of multimedia, i.e. programming language, multimedia authoring tool and web authoring tool, we determined the web authoring tool as an authoring method of our electronic textbook. Intel Pentium II 350 MHz IBM-compatible personal computer with 128 Megabyte RAM, Umax Powerlook flatbed scanner with transparency unit, Olympus Camedia l400L digital camera, ESS 1686 sound card, Sony 8 mm Handycam, PC Vision 97 pro capture board, Namo web editor 3.0, Photoshop 3.0, ThumbNailer, RealPlayer 7 basic and RealProducer G2 were used for creating the text document, diagram, figure, X-ray image, video and sound files. We made use of javascripts for tree menu structure, moving text bar, link button and spread list menu and image map etc. After creating all files and hyperlinking them, we burned out the CD-rom title with all of the above multimedia data, Netscape communicator and plug in program as a prototype. Results and Conclusions : We developed the dental radiology electronic textbook which has 9 chapters and consists of 155 text documents, 26 figures, 150 X-ray image files, 20 video files, 20 sound files and 50 questions with answers. We expect that this CD-rom title can be used at the intranet and internet environments and continuous updates will be performed easily.

  • PDF

The Effect of the Ratio of Standing to Sitting Height on the Spinal Forward Bending Range of Motion in Normal Subjects (앉은 자세와 기립 자세의 비율이 정상 성인의 체간 굴곡 유연성에 미치는 영향)

  • Kwon, Hyuk-Cheol;Jeong, Dong-Hoon
    • Physical Therapy Korea
    • /
    • v.8 no.2
    • /
    • pp.55-63
    • /
    • 2001
  • For spinal flexibility measurements to be meaningful to clinicians or researchers, they must have a normative information and an understanding of how different variables affect spinal range of motion (ROM). Normal spinal ROM measurements are influenced to differing degrees by many factors. These factors include age, gender, time of day, leisure activities, previous history of low back pain, warming up, and the techniques with which normative data are collected. The additional variables of standing height, ratio of standing height to sitting height, and obesity had not been previously studied extensively and were shown to have a significant effect on flexibility in the sagittal plane. These relationship cannot be explained easily. Thus, the purpose of this study was to determine the relationship between spinal flexibility and individual factors (weight, standing height, and ratio of standing height to sitting height) that influence it. Fifteen healthy subjects between the ages of 20 and 27 years were studied. Two physical therapists measured independently the spinal forward bending ROM in the sagittal plane by Remodified Schober test and Finger-to-floor test. In order to determine the statistical significance of the result the Pearson's correlation was applied at the .05 level of significance. The results of this study were as follows: 1) Significant relationship was not identified between spinal flexibility and weight. 2) Significant relationship was not identified between spinal flexibility and standing height. 3) Significant relationship was not identified between spinal flexibility and ratio of standing height to sitting height.

  • PDF

The Level of Pain, Gait Speed, and ROM in Community-dwelling Older Adults with Knee Joint Pain (슬관절통이 있는 재가노인의 통증과 보행속도 및 관절가동범위)

  • Kim, Kye-Ha;Lee, Jin-Min
    • Research in Community and Public Health Nursing
    • /
    • v.28 no.2
    • /
    • pp.156-164
    • /
    • 2017
  • Purpose: The purpose of this study is to investigate the level of pain, gait speed, and ROM (Range of motion) in community-dwelling older adults with knee joint pain. Methods: A convenience sample of 160 participants living in G city were recruited. Elderly people who suffer from knee joint pain with a pain level ${\geq}5$ during the last one year on a visual analogue scale were included in the study. The data were collected from June to August 2016. All statistical analyses were performed using IBM SPSS ver. 22.0. Results: Participants' pain was 6.81 by VAS. The mean gait speed was 13.9 sec/10m. The ROM of left knee and right knee were $54.06^{\circ}$ and $56.50^{\circ}$, respectively. The level of pain was different according to gender (t=-4.87, p<.001), economic status (t=3.51, p=.032), diseases (t=5.23, p<.001), diagnosis of arthritis (t=3.86, p<.001), region of knee joint pain (F=9.30, p<.001), duration of pain occurrence (F=13.82, p<.001), and limp (F=3.58, p<.001). The level of knee joint pain and gait speed had significant correlations. Conclusion: The gait speed in older adults is an important variable that should be taken into account in the assessment of their level of knee joint pain.

Effect of Rehabilitation Education Using Isokinetic Exercise on Physical Function Recovery (Isokinetic Exercise에 의한 중풍 재활교육이 인체기능회복에 미치는 영향)

  • Park, Seung-Man;Kim, Yong-Nam
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.1
    • /
    • pp.229-242
    • /
    • 1997
  • This study was performed to figure out effects of stroke rehabilitation on education using isokinetic exercise on physical function recovery. It is considered isokinetic exercise will playa primary role in muscle strength, ROM of joint, and body balance recovery for stroke rehabilitation and so far can be used as a basic references to increase the health of all people. The study consisted of 42 stroke patient(21 training group, 21 control group) diagnosed as cerebral hemorrhage from Oriental Rehabilitation Department of Kyung Hee University. Upper extremity and lower extremity exercise was performed in the training group using isokinetic ergometer. The recovery of physical function(muscle strength, ROM of joint, body balance) data between the two groups were compared and ana lysed by paired t-test are as followed. 1. Muscle testing record showed increased in the strength of elbow flexion, knee flexion, knee extension, ankle extension of the training group com paired to control group(p < .05). In the measurement of ROM, however other parts of the body motion showed no significant changes, only shoulder extension of the training group was increased(p < .05). 2. Body balance increase was highly significant in all training group compaired to control group(p<001). Based on these findings, stroke rehabilitation education with isokinetic ergometer showed available effects on recovery of physical function rehabilitation program with isokinetic exercise will play a primary role in the recovery of physical function of stroke or brain injury patients as well as to promote the health of all people.

  • PDF

Biomechanical Analysis of Injury Factor According to the Change of Direction After Single-leg Landing

  • Kim, Jong-Bin;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.433-441
    • /
    • 2016
  • Objective: The purpose of this study was to understand the injury mechanism and to provide quantitative data to use in prevention or posture correction training by conducting kinematic and kinetic analyses of risk factors of lower extremity joint injury depending on the change of direction at different angles after a landing motion. Method: This study included 11 men in their twenties (age: $24.6{\pm}1.7years$, height: $176.6{\pm}4.4cm$, weight: $71.3{\pm}8.0kg$) who were right-leg dominant. By using seven infrared cameras (Oqus 300, Qualisys, Sweden), one force platform (AMTI, USA), and an accelerometer (Noraxon, USA), single-leg drop landing was performed at a height of 30 cm. The joint range of motion (ROM) of the lower extremity, peak joint moment, peak joint power, peak vertical ground reaction force (GRF), and peak vertical acceleration were measured. For statistical analysis, one-way repeated-measures analysis of variance was conducted at a significance level of ${\alpha}$ <.05. Results: Ankle and knee joint ROM in the sagittal plane significantly differed, respectively (F = 3.145, p = .024; F = 14.183, p = .000), depending on the change of direction. However, no significant differences were observed in the ROM of ankle and knee joint in the transverse plane. Significant differences in peak joint moment were also observed but no statistically significant differences were found in negative joint power between the conditions. Peak vertical GRF was high in landing (LAD) and after landing, left $45^{\circ}$ cutting (LLC), with a significant difference (F = 9.363, p = .000). The peak vertical acceleration was relatively high in LAD and LLC compared with other conditions, but the difference was not significant. Conclusion: We conclude that moving in the left direction may expose athletes to greater injury risk in terms of joint kinetics than moving in the right direction. However, further investigation of joint injury mechanisms in sports would be required to confirm these findings.

A Study on Risk Factors of Recurrent Otitis Media (소아 재발성 중이염의 위험인자에 대한 연구)

  • Kim, Eun Jin;Kwon, Young Ran;Song, Kang Hoon;Jang, Won Nyung;Lee, Jin;Chang, Jin Keun;Cha, Sung Ho
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.91-100
    • /
    • 2010
  • Purpose : Recurrent otitis media (ROM) is usually defined as ${\geq}$3 distinct and well-documented episodes within 6 months or ${\geq}$4 episodes within 12 months. ROM is sufficiently important to warrant consideration of chemoprophylaxis, tympanostomy tube placement. There also is evidence that children with ROM are at risk for both hearing loss and speech delay. However, studies of ROM have been notably insufficient. In addition, even though environmental, racial, and sociocultural differences can affect risk factors, few studies have been conducted with regard to recurrent otitis media in Korea. Methods : This study was conducted from July 2009 to January 2010 with infants and children who were younger than 60 months old, who visited the out-patient clinics at Han-Il General Hospital and Kyunghee University Hospital. Data were collected by interview using a pre-formed sheet. Among a total of 892 infants and children, 457 were excluded, and the remaining 435 were allocated to 104 with ROM and 331 as a control group. Results : Attendance at daycare centers (P<0.001, OR=2.85), allergic rhinitis (P=0.026, OR=2.32), past history of bronchiolitis (P=0.003, OR=2.33), and low socioeconomic status (P=0.005, OR=2.00) were found to have a close significant correlation with ROM. Risk factors such as sex, having a sibling, breast-feeding, use of pacifiers, atopy, pneumococcal vaccination, influenza vaccination, smoking of parents, and indoor smoking are not relevant. Conclusion : Attendance at daycare centers, allergic rhinitis, past history of bronchiolitis, and low socioeconomic status have been identified as risk factors for ROM.

DVD와 호환 가능한 홀로그래픽 롬 시스템

  • Mun Jin-Bae;Kim Geun-Yul;Jeong Gyu-Il;Park Ju-Yeon;Nam Eun-Ha
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.145-149
    • /
    • 2005
  • We describe holographic ROM system to read bit-type data. It has optical system similar to general optical data storage system such as DVD. But because holographic data storage systems have to adopt imaging optical system, in our system bit-type data can be read out by different servos with DVD. We devised 3-hole method similar to 3- beam method for the tracking servo and used astigmatic optical system for the focusing servo. Also we developed the reference beam servo to measure movement of reference beam because especially holographic data storage systems need reference beam. The system was operated by these three servos and objective lens of NA 0.6. We obtained eye pattern from random data of 3T-2um track pitch. We also obtained another eye pattern from DVD disk by only using focusing servo PDIC in our system to verify the compatibility with DVD.

  • PDF