• Title/Summary/Keyword: ROC곡선

Search Result 159, Processing Time 0.032 seconds

Cutoff Values of Body Mass Index and Body Fat Measures for Metabolic Syndrome in Korean Population (한국인에서 대사증후군의 선별검사로서 체성분 분석 및 체질량지수의 타당성연구)

  • Lee, Hyun-Jae;Kim, Byoung-Gwon;Kim, Joon-Youn;Kim, Jung-Man;Yoo, Byung-Chul;Kim, Eun-Jeong;Hong, Young-Seoub
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • This study investigated cut-off values of body mass index (BMI) and body fat measures for metabolic syndrome (MS) in elderly Koreas. Questionnaire surveys, anthropometric measurements, medical examinations, and body composition analyses were conducted for 10,077 subjects aged 40-65 years in the health examinee cohort in Korea between 2004 and 2006. Cut-off values were identified using receiver-operating characteristic (ROC) curve analysis for both men and women. Stratified analyses by weight range (<60, 60-69, 70-79, and 80-89, ${\geq}90\;kg$ for men; <50, 50-59, 60-69, 70-79, ${\geq}80\;kg$ for women) were conducted. Among male subjects, the cut-off points were $25.5\;kg/m^2$ for BMI with a sensitivity of 70.0% and a specificity of 72.0%, and 26.1% for body fat percentage with a sensitivity of 60.6% and a specificity of 76.4%. Among female subjects, the cutoff points were $24.1\;kg/m^2$ for BMI with a sensitivity of 73.3% and a specificity of 68.8%, and 31.5% for body fat percentage with a sensitivity of 76.7% and a specificity of 65.6%. Stratified analysis by weight range showed that the cutoff points of BMI and body fat measures tended to higher as weight level increased. The results of our study suggest cut-off values of BMI and body fat measure for MS were similar to the general obesity criteria in Korea.

The Differentiation of Malignant and Benign Musculoskeletal Tumors by F-18 FDG PET/CT Studies - Determination of maxSUV by Analysis of ROC Curve (F-18 FDG PET/CT에서 양성과 악성 근골격 종양의 감별진단 - 수신자 판단특성곡선을 이용한 maxSUV의 절단값 결정)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Choi, Jun-Heok;Shin, Duk-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2007
  • Purpose: We evaluated the standard uptake value (SUV) of F-18 FDG at PET/CT for differentiation of benign from malignant tumor in primary musculoskeletal tumors. Materials and Methods: Forty-six tumors (11 benign and 12 malignant soft tissue tumors, 9 benign and 14 malignant bone tumors) were examined with F-18 FDG PET/CT (Discovery ST, GE) prior to tissue diagnosis. The maxSUV(maximum value of SUV) were calculated and compared between benign and malignant lesions. The lesion analysis was based on the transverse whole body image. The maxSUV with cutoff of 4.1 was used in distinguishing benign from malignant soft tissue tumor and 3.05 was used in bone tumor by ROC curve. Results: There was a statistically significant difference in maxSUV between benign (n=11; maxSUV $3.4{\pm}3.2$) and malignant (n=12; maxSUV $14.8{\pm}12.2$) lesions in soft tissue tumor (p=0.001). Between benign bone tumor (n=9; maxSUV $5.4{\pm}4.0$) and malignant bone tumor (n=14; maxSUV $7.3{\pm}3.2$), there was not a significant difference in maxSUV. The sensitivity and specificity for differentiating malignant from benign soft tissue tumor was 83% and 91%, respectively. There were four false positive malignant bone tumor cases to include fibrous dysplasia, Langerhans-cell histiocytosis (n=2) and osteoid osteoma. Also, one false positive case of malignant soft tissue tumor was nodular fasciitis. Conclusion: The maxSUV was useful for differentiation of benign from malignant lesion in primary soft tissue tumors. In bone tumor, the low maxSUV correlated well with benign lesions but high maxSUV did not always mean malignancy.

Diagnostic Availability of Estrogen Receptor Alpha mRNA on Cervical Cancer Tissue (자궁경부암 조직에서 에스트로겐 수용체 알파 mRNA의 진단적 유용성)

  • Kim, Geehyuk;Yu, Kwangmin;Kim, Jungho;Kim, Seoyong;Park, Sunyoung;Ahn, Sungwoo;Lee, Ji-Young;Kim, Sunghyun;Park, Ho-Hyun;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.449-456
    • /
    • 2018
  • Cervical cancer is the fourth most frequently diagnosed cancer in women worldwide. In lower Human Development Index countries, it has the second highest incidence and mortality among cancer in women. Therefore, better diagnosis and treatment systems are needed. Among them, estrogen receptor alpha ($ER-{\alpha}$) mRNA expression has been analyzed with RT-qPCR since several studies reported that $ER-{\alpha}$ is necessary in the maturation of the uterus and is related to cervical cancer. In this study, $ER-{\alpha}$ quantitative analysis was performed on various lesions and normal tissue samples. Based on the receiver operating characteristic (ROC) curve, its sensitivity and specificity were 85% and 75%, respectively, showing higher or similar results to those of conventional HPV tests. In addition, its expression level was analyzed with clinical information. With regression analysis, the R square value between the $ER-{\alpha}$ mRNA expression level and menopause status was 0.5041, indicating a strong correlation. This study was performed as part of a pilot study and suggests that $ER-{\alpha}$ is related to carcinogenesis. Future studies will examine other hormones and menopausal factors with a larger sample size.

Correlation between Carotid Intima-media Thickness and Risk Factors for Atherosclerosis (경동맥 내중막 두께에 따른 죽상경화반의 위험요인과의 상관관계)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.339-348
    • /
    • 2019
  • The purpose of this study was to investigate the effect of carotid artery ultrasound Respectively. The carotid intima-media thickness is known to have a significant correlation with cardiovascular disease and cerebrovascular disease. We investigated the relationship between carotid intima - media thickness, body mass index, waist circumference, the blood lipid value, fasting blood glucose, glycated hemoglobin, and blood pressure using carotid artery ultrasound. The carotid artery ultrasound was considered to be abnormality of IMT thickness over 0.8 mm and the presence or absence of atherosclerotic plaque was evaluated. Serological tests were used to compare the geologic value, fasting blood glucose level, and glycated hemoglobin. As a result, waist circumference (=.022), low density cholesterol (=.004), fasting blood glucose level (.019), and glycemic index (.002) were analyzed as predictors of atherosclerosis. In the ROC curve analysis, sensitivity was 87.80% (95% CI: 73.8-95.9), specificity was 41.67% (95% CI: 30.2-53.9), sensitivity was 78.05% (95% CI: 62.4-89.4) in low density lipoprotein, Specificity was 50.00% (95% CI: 38.0-62.0), sensitivity was 73.11% (95% CI: 57.1-85.8), specificity was 61.11 (95% CI: 48.9-72.4) and sensitivity was 82.93%-91.8) and a specificity of 43.06% (31.4-55.3). In logistic regression analysis, the risk of atherosclerosis was 0.248 times at waist circumference (WC)> 76 cm, 3.475 times at low-density lipoprotein (LDL-C) ${\geq}124mg/dL$, 0.618 at HbA1c> 5.4% It appeared as a times. We suggest that prospective study of carotid artery ultrasound should be performed for the effective prevention of cardiovascular diseases.

The Quantitative Evaluation of Cardiac Calcification Using 18F-Sodium fluoride PET/CT (18F-Sodium fluoride PET 이용한 심장 석회화 정량평가에 대한 고찰)

  • Choi, Yong Hoon;Lee, Seung Jae;Kang, Chun Goo;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.38-42
    • /
    • 2019
  • Purpose Although computed tomography (CT) is used for coronary artery calcification, it is difficult to differentiate between high risk microcalcifications. Studies have shown that $^{18}F$-sodium fluoride ($^{18}F-NaF$) is very useful for the diagnosis of microcalcifications. In this study, we aimed to evaluate the usefulness of $^{18}F-NaF$ PET imaging in quantitative evaluation of calcification. Materials and Methods A total of 45 patients ($67.1{\pm}6.9years\;old$) were injected with 250 MBq of $^{18}F-NaF$ for 1 hour and images were acquired for 30 minutes. All patients underwent CT angiography (CTAngiography, CTA) before the PET scan. The SUVmax of calcification was measured and the background radioactivity of the left atrium was measured to determine Target to Background (TBR) and quantitatively analyzed. High risk group was classified through ROC curve (Receiver Operating Characteristic Curve). Results There were 226 coronary artery calcifications in the cohort and SUVmax was $1.15{\pm}0.39$. Of the 28 patients (62%), 58 were classified as high risk (TBR > 1.25). The remaining 168 were $TBR{\leq}1.25$. Conclusion $^{18}F-NaF$ PET images were available for quantitative assessment of microcalcifications and could be classified into high-risk groups. The combination of angiographic CT and $^{18}F-NaF$ PET may be a new method for early diagnosis of high-risk microcalcifications.

A Longitudinal Validation Study of the Korean Version of PCL-5(Post-traumatic Stress Disorder Checklist for DSM-5) (PCL-5(DSM-5 기준 외상 후 스트레스 장애 체크리스트) 한국판 종단 타당화 연구)

  • Lee, DongHun;Lee, DeokHee;Kim, SungHyun;Jung, DaSong
    • Korean Journal of Culture and Social Issue
    • /
    • v.28 no.2
    • /
    • pp.187-217
    • /
    • 2022
  • The aim of this study is to examine the psychometric properties of the Korean version of the Post-traumatic Stress Disorder Checklist for DSM-5(PCL-5). For this purpose, online surveys were conducted for two times with a one year interval using the data from 1,077 Korean adults at time 1, and 563 Korean adults at time 2. First, from the result of the confirmatory factor analysis, comparing the model fit of the 1, 4, 6, and 7-factor model, the 4, 6, and 7-factor model showed a acceptable fit, and the best fit was seen in the order of the 7, 6, 4-factor model. Second, the internal consistency, omega coefficient, construct validity, average variance extracted, and test-retest reliability results were all satisfactory.. Third, a correlation analysis with the K-PC-PTSD-5 and the sub-factors of BSI-18 was conducted to check the validity of the Korean Version of PCL-5. As a result, a positive correlation was seen with both K-PC-PTSD-5 and BSI-18. Fourth, a hierarchical multiple regression was performed to examine whether the Korean Version of PCL-5 predicts future PTSD, depression, anxiety, and somatization. As a result, the Korean Version of PCL-5 measured at time 1 significantly predicted PTSD, depression, anxiety, and somatization symptoms at time 2. Fifth, by analyzing the ROC curve, the discriminant power of PCL-5 for screening PTSD symptom groups was confirmed, and the best cut-off score was suggested. As a result of the longitudinal validation of Korean version of PCL-5, it was found that this scale is a reliable and valid measure for Korean adults. By looking into the predictive validity of the scale, it was found that the Korean version of PCL-5 can predict not only PTSD symptoms but also PTSD-related symptoms such as depression, anxiety, and somatization. Also, this study differs from previous validation studies measuring PTSD symptoms in that it suggested a cut-off score to help differentiate PTSD symptom groups.

Development of Reminiscence Function Scale-Short Form: A Study on Reliability and Validity (단축형 회상기능척도(Reminiscence Function Scale-Short Form) 개발 : 신뢰도 및 타당도 연구)

  • Cha, Yu-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.6
    • /
    • pp.225-235
    • /
    • 2016
  • This study aims at developing Reminiscence Function Scale-Short Form(RFS-S) and verifying it as a supplemental diagnosis instrument to judge differences between normal and mild cognitive impairment and useful measure to rate effects of reminiscence therapy in the clinical field through internal consistency reliability and criterion validity. The study also aims at figuring out factors affection reminiscence function by figuring out demographic features of RFS-S. The research subjects were the control group of 60 normal people and experimental group of 58 people with mild cognitive impairment and both groups were over 65 years old. For internal consistency reliability(Cronbach's alpha) between questions was reliable with 0.63. Convergent validities of RFS-S with SRT and CDR-SB were 0.20(p<.05) and -0.25(p<.001), respectively, as both showed significant correlations. As a result of criterion validity to analyze AUROC, it was 0.68(p<.001) and less accurate. Its optimal cut-off points were 17 and sensitivity according to them was 0.59, and specificity was 0.72, respectively. However, reminiscence function according to demographic variables did not show any significant differences. Therefore, it is expected that RFS-S will be used as a supplemental diagnosis instrument with higher reliability and validity for discerning differences between normal and mild cognitive impairment and as a useful one to verify effects of reminiscence therapy.

The Value of Calcium-scoring CT for Ischemic Cardiovascular Disease Screening (허혈성 심혈관 질환 선별을 위한 Calcium-scoring CT의 유용성)

  • Oh, Jung-Hoan;An, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.69-78
    • /
    • 2009
  • The cardiovascular disease has been known as a common cause of death for a long time in the west. The eating habits of Asia, including Korea, have changed recently, so that this disease is also a problem in Asia now. Annual Report on the Cause of Death Statistics from 1996 to 2006 reported that the cardiovascular disease would become the number one cause of death in the next $5{\sim}10$ years. Therefore we realize that more accurate examination is required. The aim of this study was to investigate the accuracy of Calcium-scoring CT and the relationship between risk factor and quantitative scores of Calcium-scoring CT. Through this study we expect that the national public health will be improved. Seventy patients with chest pain were chosen at random. The patients were undergone both coronary CT antigraphy and Calcium - scoring CT at G hospital in Incheon from February 1 to June 30, 2008. The result of the Calcium-scoring CT showed its usefulness for Ischemic cardiovascular disease, with an accuracy similar to that of exercise/pharmacologic stress or ECG when it is difficult for a patient to exercise due to joint problems, aging or for other reasons.

  • PDF

Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass (유방종괴에 대한 BI-RADS범주를 이용한 횡탄성 초음파와 병리결과 비교분석)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.217-223
    • /
    • 2018
  • This study to search the diagnostic performance of shear wave elastography(SWE) in breast mass and to compare the biopsy result and stiffness obtained from shear wave elastography. Diagnostic breast ultrasonography and SWE were targeted for 157 patients who had breast ultrasonography was diagnosed mass from June 2017 to September 2017. Pathology results of 157 patients showed a benign 92 patients(Age, $44.54{\pm}11.84$) and a malignancy 65 patients(Age, $51.55{\pm}10.54$). Final evaluation, biopsy result, and quantitative SWE result were obtained and compared with each other according to Breast Imaging Reporting and Data System(BI-RADS) of diagnostic breast ultrasonography. Quantitative SWE value and pathologic result showed the highest diagnostic specificity of 83.70% in Emean and sensitivity of 89.23% in Emin. Quantitative SWE result and biopsy result is statistically significant.(p=0.000). The optimal cut-off value for malignant lesions was 66.3 kPa and 63.7 kPa, respectively, for the sensitivity, specificity, high maximum mean elasticity value(Emax) and mean elasticity value(Emean) and this showed the highest diagnostic area under the ROC curve(Az) value compared to other SWE measurement(p=0.000). The addition of SWE to conventional US in breast mass make a increase diagnostic specificity and reduce unnecessary biopsy. Therefore, it is expected that it will be helpful to analyze the breast mass using the above analysis and apparatus.

Signal-Averaged P Wave Analysis in Patients with Paroxysmal Atrial Fibrillation (발작성 심방세동 환자의 신호평균 P파 분석)

  • 김인영;이종연;이병채;이용희;이종민;김선일;김준수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Atrial fibrillation(AF). chronic or paroxysmal is the most frequent arrhythmia in human subjects Duration of P wave in signal-averaged electrocardiography(SAECG) reflects intra-atrial conduction time and therefore. could be used as an electrophysiological marker for atrial conduction chance at the earthy stave. So we apply the analysis method using SAECG to diagnose Paroxysmal atrial fibrillation(PAF) . Subjects Participated for the study consisted of two groups: a control group(n=34) of normal healthy volunteers and a group of AF Patients(n=38) with a documented history of PAF but no other history of cardiac disease. We evaluated the effect of several filtering and determination methods to find the starting and ending feints of the P wavy on its duration. To increase the measurement reliability of P wave duration. the automatic detection method was proposed. Also. to increase the detection rate for PAF risk, the decision threshold value was optimized using receiver operation characteristics(ROC) curve. Results showed that the highest statistical difference (p〈0.001) of the P wane duration between controls and subjects was obtained at the Processing condition, using absolute threshold vague(8.75 $\mu N$) , a least mean square(LMS) high pass filter and 30 Hz cutoff frequency. The most outstanding difference(sensitivity 88 % specificity 64.4 %) between controls and subjects was obtained at the decision threshold value of 112 ms.