• Title/Summary/Keyword: RO(Reverse Osmosis)

Search Result 231, Processing Time 0.022 seconds

A Study on Condition-based Maintenance Policy using Minimum-Repair Block Replacement (최소수리 블록교체 모형을 활용한 상태기반 보전 정책 연구)

  • Lim, Jun Hyoung;Won, Dong-Yeon;Sim, Hyun Su;Park, Cheol Hong;Koh, Kwan-Ju;Kang, Jun-Gyu;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.18 no.2
    • /
    • pp.114-121
    • /
    • 2018
  • Purpose: This study proposes a process for evaluating the preventive maintenance policy for a system with degradation characteristics and for calculating the appropriate preventive maintenance cycle using time- and condition-based maintenance. Methods: First, the collected data is divided into the maintenance history lifetime and degradation lifetime, and analysis datasets are extracted through preprocessing. Particle filter algorithm is used to estimate the degradation lifetime from analysis datasets and prior information is obtained using LSE. The suitability and cost of the existing preventive maintenance policy are each evaluated based on the degradation lifetime and by using a minimum repair block replacement model of time-based maintenance. Results: The process is applied to the degradation of the reverse osmosis (RO) membrane in a seawater reverse osmosis (SWRO) plant to evaluate the existing preventive maintenance policy. Conclusion: This method can be used for facilities or systems that undergo degradation, which can be evaluated in terms of cost and time. The method is expected to be used in decision-making for devising the optimal preventive maintenance policy.

Simulation of membrane lifetime by analysis on deterioration of reverse osmosis membrane (역삼투 막 열화 분석을 통한 막 수명 모의)

  • Sun-A An;Seong-Min Cho;Han-Seung Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.4
    • /
    • pp.223-232
    • /
    • 2024
  • This study was conducted to simulate the lifetime of the membrane by analyzing the performance of the membrane degraded by chlorine. Chlorine exposure under several conditions caused the degradation of the membrane, resulting in the absence of any salts and an extreme increase in permeability. When the n value was calculated and compared through CnT analysis and CTn analysis, the p values were all less than 0.005, but CTn analysis, which had a higher R2 value, was adopted to simulate the membrane lifetime. Power coefficients take on values higher than 1, indicating that the exposure time to chlorine has a greater influence on membrane deterioration than the chlorine exposure concentration at 20℃ and 30℃. In particular, the process should be operated at less than 0.5 ppm at 30℃, and the chlorine exposure time of 1 cycle should be set to within 15 hours. In addition, the sensitivity to chlorine increased by 10.5 to 12.2 times when the chlorine exposure temperature increased by 10℃ through the correlation between the chlorine exposure cycle and membrane lifetime. The membrane lifetime investigated in this study is only an estimated value, entirely because of chlorine membrane deterioration, excluding raw water characteristics and the type of detergent. Accordingly, it is considered that the membrane lifetime simulation can be applied by comparing the membrane performance with the actual process based on the filtration performance of membrane deterioration by chlorine.

Studies on the Efficient Concentration Process of Apple Juice with Reverse Osmosis Process (역삼투막 공정을 이용한 사과쥬스의 효율적인 농축공정에 관한 연구)

  • Hur, Sang-Sun;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.321-326
    • /
    • 1993
  • Membrane separation technology with polymeric membranes for the effective separation and energy conservation has emerged to be a new technology for separation in recent years. In this research, the reverse osmosis process was applied to the concentration process of clarified apple juices. The changes of concentration and permeate flux of apple juice in this process were measured at different membrane characteristics, operating pressures, temperature and flow rate. And the changes of quality were also measured at different pressures. The prediction model for the permeate flux based on these data was established. Generally, the osmotic pressure increased as the concentration of the feed increased in the RO process, which caused a reduction of permeate flux. The changes of permeate flux were not much dependent on temperature and flow rate, but very much dependent on pressure. The most effective factor in increased permeate flux was found to be the operating pressure, followed by temperature and flow rate. The final prediction model for the permeate flux was developed by the $SPSS^x$ computer program. The result showed that recovery of sugar was not affected by processing pressures, but the percentage recovery of total flavor was increased with increasing pressure.

  • PDF

An Economic Analysis of Desalination for Potential Application in Korea (국내 적용을 위한 해수 담수화 경제성 분석)

  • Park, No Suk;Park, Hee Kyung;Park, Mi Hyun;Kim, Byung Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.48-54
    • /
    • 1998
  • Korea becomes one of the countries which suffer from water shortage. It is expected that its water shortage in the early 2000's will be more than 10% of the annual demand. The shortage problem is more serious in the coastal areas where many industry complex locate. To solve the shortage problem, seawater desalination gets more attention as an alternative water supply source since Korea is surrounded by sea on its three sides. For potential application of seawater desalination in Korea, an economic analysis was conducted using cost data for the plants in the Middle Ease areas, The United states and others. The study is to provide a basis for the government to establish a strategy for promoting seawater desalination in Korea. It is discussed that the Reverse Osmosis (RO) process gets cheaper over times than the thermal processes of Multi-stage Flash Distillation (MSF) and Multi Effect Distillation (ME), especially in case where the capacity is less than about 50,000 ton/day. The unit cost of RO seawater is analyzed about US$1.35/ton in 1990 price. Since the Desalination plant can be operated regardless of weather conditions, industries in Korea's coastal areas which suffer from frequent droughts and water shortages are recommended to look into this option with more attention.

  • PDF

Industrial dairy wastewater purification by shear-enhanced membrane filtration: The effects of vibration

  • Kertesz, Szabolcs
    • Membrane and Water Treatment
    • /
    • v.5 no.2
    • /
    • pp.73-86
    • /
    • 2014
  • Membrane fouling is a major challenge limiting the use of membrane applications. In this study high induced shear rates were utilized at the membrane surface in order to reduce the organic and inorganic scaling by using the torsional vibration of flat sheet membranes. The performances of a vibratory shear-enhanced processing (VSEP) system for the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membrane filtration of industrial dairy wastewater were investigated. The vibration and non-vibration methods were compared with the same membrane and operational parameters during the purification of real dairy industrial process wastewater. In the initial experiments, short-term tests were carried out in which the effects of vibration amplitude, recirculation flow rate and transmembrane pressure were measured and compared. The permeate flux, turbidity, conductivity and chemical oxygen demand (COD) reduction of dairy wastewater were investigated by using UF, NF and RO membranes with vibration and non-vibration methods. In the subsequent experiments, concentration tests were also carried out. Finally, scanning electron microscopy (SEM) revealed that the vibration method gave a better performance, which can be attributed to the higher membrane shear rate, which reduces the concentration of solids at the membrane, and the transmission.

Optimization of chemical cleaning of discarded reverse osmosis membranes for reuse

  • Jung, Minsu;Yaqub, Muhammad;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • This study optimized the chemical cleaning process of discarded RO membranes for reuse in less demanding separation processes. The effect of physicochemical parameters, including the temperature, cleaning time, pH of the cleaning solution, and addition of additives, on the cleaning process was investigated. The membrane performance was evaluated by testing the flux recovery rate and salt rejection before and after the cleaning process. High temperatures (45-50 ℃) resulted in a better flux recovery rate of 71% with more than 80% salt rejection. Equal time for acid and base cleaning 3-3 h presented a 72.43% flux recovery rate with salt rejection above 85%. During acid and base cleaning, the best results were achieved at pH values of 3.0 and 12.0, respectively. Moreover, 0.05% concentration of ethylenediaminetetraacetic acid presented 72.3% flux recovery, while 69.2% flux was achieved using sodium dodecyl sulfate with a concentration of 0.5%; both showed >80% salt rejection, indicating no damage to the active layer of the membrane. Conversely, 0.5% concentration of sodium percarbonate showed 83.1% flux recovery and 0.005% concentration of sodium hypochlorite presented 85.2% flux recovery, while a high concentration of these chemicals resulted in oxidation of the membrane that caused a reduction in salt rejection.

Physical and Chemical Characterization of Recycled Oxide CMP Slurry (재생된 옥사이드 CMP 슬러리의 물리적, 화학적 특징에 대한 연구)

  • 김명식;박진구;이관호
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.235-239
    • /
    • 2001
  • In recent years, as Chemical Mechanical Planarization(CMP) has been routinely utilized in integrated circuit(IC) fabrication, the consumption of slurry, main consumable in a CMP process, is greatly increased. Thus the reprocess of CMP slurries has been actively considered in the industry to reduce cost-of-consumable (COC). The main purpose of this study was to recycle the used oxide slurry using filters as a new method. As a result, Ultra Fine(UF) Filter could distinguish silica from the used oxide slurry and Reverse Osmosis(RO) Filter could distinguish Deionized(DI) Water and chemistry from chemistry solution. The tetraethylorthosilicate removal rate was almost the same as the number of recycle polishing was increased, when it was modified by slightly adding new SS-12 slurry. The microscratch didnt found as the number of recycle polishing was increased.

  • PDF

PREPARATION OF ASYMMETRIC POLYIMIDE MEMBRANTES BY THE PHASE INVERSION PROCESS

  • Nakane, Takashi;Yanagishita, Hiroshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.10a
    • /
    • pp.7-12
    • /
    • 1993
  • Preparation of asymmetric polyimide membranes by the phase inversion process was investigated to develop ultrafiltration, reverse osmosis and pervaporation membranes for organic solutions, using a commercially available solvent-soluble polymaide. The influences of the various factors such as the composition of a cast solution, casting conditions, gelating solutions and others on membrane structure and performance were studied in detail, and it was made clear that a wide variety of asymmetric polyimide membranes ranging from UF to RO for organic solutions could be prepared from the aromatic polyimide used. It was also found that the chemical stability and separation performance of the asymmetric polyimide membranes could be improved by annealing in a liquid or a vacuum at above 200$\circ$. The membrane annealed at 300$\circ$ in a vacuum exhibited the separation factor $\alpha(H_2O/EtOH)$ of 900 with the flux of 1.0 kg/$m^2\cdot h$ at 60$\circ$C for an aqueous ethanol solution of 95 vol%.

  • PDF

Progresses in membrane and advanced oxidation processes for water treatment

  • Khulbe, K.C.;Feng, C.Y.;Matsuura, T.;Ismail, A.F.
    • Membrane and Water Treatment
    • /
    • v.3 no.3
    • /
    • pp.181-200
    • /
    • 2012
  • At present water crisis is not an issue of scarcity, but of access. There is a growing recognition of the need for increased access to clean water (drinkable, agricultural, industrial use). An encouraging number of innovative technologies, systems, components, processes are emerging for water-treatment, including new filtration and disinfectant technologies, and removal of organics from water. In the past decade many methods have been developed. The most important membrane-based water technologies include reverse osmosis (RO), ultrafiltration (UF), microfiltration (MF), and nanofiltration. Beside membrane based water-treatment processes, other techniques such as advanced oxidation process (AOP) have also been developed. Some unconventional water treatment technology such as magnetic treatment is also being developed.

제주도 대체수자원 확보를 위한 하수처리장 방류수 재이용 연구

  • Kang, Bong-Rae;Kim, Geon-Tae;Koh, Gi-Won;Heo, Mok
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.180-183
    • /
    • 2003
  • 제주지역 하수종말처리장에서 발생하는 방류수(2차 처리수)를 재이용함으로써 지하수에 편중된 제주도의 용수 이용패턴을 다원화하는 대체수자원으로 활용하기 위하여 2001년 6월부터 하수처리장 방류수 재이용 방안연구를 실시하였다. 제주도내에서 운영 중인 3개 하수종말처리장의 방류수에 대한 장기적인 수질검사 결과, 염소이온 함량이 높아 재처리를 하지 않은 상태로 재이용 하기는 곤란한 것으로 파악되었다. 따라서, 재처리를 위한 최적의 공정을 선정하기 위해 pilot test를 실시한 결과, 방류수를 MF(정밀여과)막 전처리 + RO(역삼투)막 처리의 재처리 공정으로부터 재처리된 물(3차 처리수)의 수질은 먹는물로 사용하더라도 전혀 문제가 없을 만큼 깨끗하게 처리되었다. 따라서 방류수 배출량이 많은 제주시 도두 하수처리장과 서귀포 보목 하수처리장의 방류수를 재처리하여 비음용 생활용수, 골프장 관개 수용수, 농업용수, 지하수 인공 함양용수 등으로 재이용하는 방안을 제시하였다.

  • PDF