• Title/Summary/Keyword: RMS Value

Search Result 395, Processing Time 0.029 seconds

Input-Output Gains of Linear Periodic Time-Varying Systems with Applications to Multirate Signal Processing (다중비 신호처리에 적용한 선형 주기적 시변 시스템의 입출력 이득)

  • 이상철;박계원
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.963-969
    • /
    • 2000
  • In this paper, we define two input-output gains of linear periodic time-varying systems. One is the ratio of output with worst-case l2-norm over all inputs with unit 12-norm. It denotes G($\iota_2,\iota_2$.The other is the ratio of output with worst-case RMS value over all inputs with unit RMS value. It denotes G(RMS, RMS) .It is fact that these two gains are equivalent for linear time-invariant system. In this paper, we prove these two gains are also equivalent for linear periodic time-varying system. In addition, the relationship between two method of obtaining the generalized frequency responses for linear periodic time-varying system is derived. Finally, we apply the defined input-output gains to M-channel filter-bank which is multi-rate signal Processing system, used to speech coding. In the filter-bank, generally, aliasing distortion, magnitude distortion, and phase distortion are present. It is shown that these are kept small if the filter-bank is designed by a method that optimizes the gain G($\iota_2,\iota_2$ of an error system.

  • PDF

A Study on the Evaluation of Repeated Measurement Stability of 3D Tooth Model Obtained by Several Dental Scanners (수종의 치과용 스캐너로 채득된 3차원 치아 모형의 반복측정 안정성 평가 연구)

  • Bae, Eun-Jeong;Kim, Won-Soo;Lim, Joong Yeon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.5
    • /
    • pp.996-1003
    • /
    • 2021
  • The purpose of this study is to evaluate the reliability of repeated measurements of several dental scanners. Blue-lighted scanners, white-light scanners and optical-type scanners are used in the study of repeatability in this study. The measurement results were calculated as root mean square (RMS) and the significance level was confirmed by applying the 1-way ANOVA statistical technique (𝛼=.05). According to the statistical analysis, the scanner with the largest RMS value was Z-opt group (38.2 ㎛. Next, D-white was 35.2 ㎛ and the group with the lowest RMS value was I-blue (34.1 ㎛). The comparison of RMS means between each group was not significant (p>.05). From this result, the blue light had the lowest error in repeatability of dental scanners, but no statistical significance. The conclusion of this study is that the study results are clinically acceptable.

Investigation for the Characters of Human Perception Level according to Acceleration Value Parameters (가속도 크기 변수에 따른 수직진동에 대한 인지수준 고찰)

  • Lee, MinJung;Han, SangWhan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.731-740
    • /
    • 2014
  • Occupants induced floor vertical vibrations may cause other occupant's annoyance and lead to social loss. To help control such floor vibrations, several criteria have been developed mostly based on human perception tests and floor vibration tests. Floor vibration is evaluated by comparison with criteria and vibration parameters of subject floor, such as frequency, damping ratio, acceleration value, vibration duration time and occurrence frequency. Three acceleration value parameters are used in criteria; peak acceleration, rms acceleration and VDV, when a floor vibration serviceability is evaluated. Meanwhile rms acceleration and peak acceleration are adopted as vibration limit value in criteria and researches of human perception for vibration. Occupants induced floor vibration is transient rather than steady state. However, rms acceleration is not reliable parameter for evaluating transient vibration. The objective of this study is to investigate the characters of human perception level according to acceleration value parameters for vibration induced by heel impacts and walking activities.

A Study on the In-process Detection of Fracture of Endmill by Acoustic Emission Measurement (음향방출을 이용한 가공중의 엔드밀 파손 검출에 관한 연구)

  • Yoon, Jong-Hak;Kang, Myung-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.3
    • /
    • pp.75-82
    • /
    • 1990
  • Automatic monitoring of the cutting conditions is one of the most improtant technologies in machining. In this study, the feasibility in applying acoustic emission(AE) signals for the in-process detection of endmill wear and fracture has been investigated by performing experimental test on the NC vertical milling machine with SM45C for specimen. As the results of detecting and analyzing AE signals on various cutting conditions, the followings have confirmed. (1) The RMS value of acoustic emission is related sensitively to the cutting velocity, but is not affected largely by feed rate. (2) The burst type AE signals of high level have been observed when removing chips distorderly and discontinuously. (3) When the RMS value grows up rapidly due to the increase of wear the endmill are generally broken or fractured, but when the endmills fracture at the conditions of smooth chip-flow or built-up-edge(BUE) occurred frequently, the rapid change of the RMS arenot found. And it is expected that this technigue will be quite useful for in-process sensing of tool wear and fracture.

  • PDF

The RMS Characteristics of Cutting Force Depending on the Tool Wear (공구마멸에 따른 절삭력의 RMS특성)

  • 권용기;오석형;김동현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2214-2222
    • /
    • 1993
  • With the use of the NC machine tool, the unmanned production system has been growing recently in the manufacturing field. This there are problems with monitoring adequate tool fracture during the cutting process efficiently. This study was planned and carried out to discover a way of monitoring tool condition in NO-LINE systems during the cutting process. The acquisition of data in cutting force and tool wear has been made in the section examined, to extract the RMS value of the cutting force as specific factors in the cutting process. The fluctuation of the RMS characteristics. From the results, it has been shown that the fluctuation of the RMS values for the cutting force has a close relation to flank wear.

The Changes of Range of Motion of Lumbar Region and Muscle Activities of Lumbar Extensor During Trunk Motions Between Subjects With Low Back Pain and Healthy Subjects (만성요통환자와 정상인의 체간 운동시 요추 신전근의 근활성도와 관절운동범위의 변화)

  • Kim, Tae-Ho
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.61-69
    • /
    • 2006
  • The purpose of this study was to compare the electromyography (EMG) activities of the lumbar extensor muscles during motion of trunk flexion-extension and compare range of motion (ROM) with a 3-dimensional motion analysis system of the lumbar region between subjects with chronic low back pain (CLBP) and healthy subjects during the trunk flexion-extension, trunk rotation and trunk lateral flexion cycle. Thirty CLBP subjects and thirty healthy subjects were included. We measured the root mean square (RMS) value of the lumbar extensor muscles from resting, standing, lumbar flexion and return position. The RMS ratio was normalized from maximal EMG activity of the lumbar extensor muscles during trunk motion. The results of this study showed that the RMS ratio of the lumbar extensor was significantly higher in CLBP subjects than healthy subjects during all of trunk motion (p<.05). The ratio of the highest RMS value during flexion and extension was higher in CLBP subjects than in healthy subjects (p<.05). The ROM of the lumbar region was significantly lower in CLBP subjects than healthy subjects during trunk flexion-extension, trunk rotation and lateral flexion cycle. The relationship between the RMS ratio for full lumbar flexion and the ROM of lumbar flexion was not correlated significantly. CLBP subjects have both decreased ROM of the lumbar region and higher muscle activities of the lumbar extensor muscle than healthy subjects.

  • PDF

Unsteady 2-D flow field characteristics for perforated plates with a splitter

  • Yaragal, Subhash C.
    • Wind and Structures
    • /
    • v.7 no.5
    • /
    • pp.317-332
    • /
    • 2004
  • Wind tunnel experiments were conducted under highly turbulent and disturbed flow conditions over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on fluctuating velocities and fluctuating pressures measured across and along the separation bubble was studied. The different perforation levels of the normal plate; that is 0%, 10%, 20%, 30%, 40% and 50% are studied. The Reynolds number based on step height was varied from $4{\times}10^3$ to $1.2{\times}10^4$. The shape and size of the bubble vary with different perforation level of the normal plate that is to say the bubble is reduced both in height and length up to 30% perforation level. For higher perforation of the normal plate, bubble is completely swept out. The peak turbulence value occurs around 0.7 to 0.8 times the reattachment length. The turbulence intensity values are highest for the case of solid normal plate (bleed air is absent) and are lowest for the case of 50% perforation of the normal plate (bleed air is maximum in the present study). From the analysis of data it is observed that $\sqrt{\overline{u^{{\prime}2}}}/(\sqrt{\overline{u^{{\prime}2}}})_{max}$, (the ratio of RMS velocity fluctuation to maximum RMS velocity fluctuation), is uniquely related with dimensionless distance y/Y', (the ratio of distance normal to splitter plate to the distance where RMS velocity fluctuation is half its maximum value) for all the perforated normal plates. It is interesting to note that for 50% perforation of the normal plate, the RMS pressure fluctuation in the flow field gets reduced to around 60% as compared to that for solid normal plate. Analysis of the results show that the ratio [$C^{\prime}_p$ max/$-C_{pb}(1-{\eta})$], where $C^{\prime}_p$ max is the maximum coefficient of fluctuating pressure, $C_{pb}$ is the coefficient of base pressure and ${\eta}$ is the perforation level (ratio of open to total area), for surface RMS pressure fluctuation levels seems to be constant and has value of about 0.22. Similar analysis show that the ratio $[C^{\prime}_p$ max/$-C_{pb}(1-{\eta})]$ for flow field RMS pressure fluctuation levels seems to be constant and has a value of about 0.32.

Study of Sequale of Low Back Pain in Traffic Accident Patients (교통사고 환자의 요통후유증에 대한 고찰)

  • Cho, Won-young;Lee, Kyoung-yoon;Park, Kwae-hwan
    • Journal of Acupuncture Research
    • /
    • v.20 no.6
    • /
    • pp.36-44
    • /
    • 2003
  • Objective: We have various ways in evaluating the level of low back pain as sequelae, general approaches such as neurologic examination, MRI, Radiologic examination and evaluating the effect of psychological stress on the low back pain. Besides We can find another approach to evaluating the sequale of low back pain in TA patients. So, I intend to analyze how much relationship the patients that got low back pain by TA have with Roland Morris Disability Scale(RMS) in 2 months after discharge. Methods: In this article, I will compare two results of TA inpatients and non-TA inpatients, which obtained with the RMS. This study was carried out about 22 TA patients and 18 non-TA patients, who had low back pain and were hospitalized between March 2002 and July 2002. Results & conclusions : 1. RMS point is related with the post-discharge term to a point of time of answering the questionnaire in both TA patients and non-TA patients. 2. In distribution of RMS point, Gr II take most possesion as 41% in TA patients while Gr I take most possesion as 56% in non-TA patients. 3. In distribution of RMS point, patients that correspond to more than Gr III take 27% in TA patients, 16% in non-TA patients. 4. TA patients show higher level of distribution than non-TA patients in RMS point in verifying them by mean value and T-test. 5. Degree of pain score change(${\Delta}$P.S), using mean value and T-test, showed lower level of distribution in TA patients than non-TA patients. 6. We can see that TA patients have more restriction in their life for low back pain.

  • PDF

Development of reference materials for cement paste

  • Lee, Dong Kyu;Choi, Myoung Sung
    • Advances in concrete construction
    • /
    • v.9 no.6
    • /
    • pp.547-556
    • /
    • 2020
  • This study aimed to develop reference materials (RMs) that are chemically stable and can simulate the flow characteristics of cement paste. To this end, the candidate components of RMs were selected considering the currently required properties of RMs. Limestone, slag, silica, and kaolin were selected as substitutes for cement, while glycerol and corn syrup were selected as matrix fluids. Moreover, distilled water was used for mixing. To select the combinations of materials that meet all the required properties of RMs, flow characteristics were first analyzed. The results revealed that silica and kaolin exhibited bilateral nonlinearity. When an analysis was conducted over time, slag exhibited chemical reactions, including strength development. Moreover, fungi were observed in all mixtures with corn syrup. On the other hand, the combination of limestone, glycerol, and water exhibited a performance that met all the required properties of RMs. Thus, limestone, glycerol, and water were selected as the components of the RMs. When the influence of each component of the RMs on flow characteristics was analyzed, it was found that limestone affects the yield value, while the ratio of water and glycerol affects the plastic viscosity. Based on this, it was possible to select the mixing ratios for the RMs that can simulate the flow characteristics of cement paste under each mixing ratio. This relationship was established as an equation, which was verified under various mixing ratios. Finally, when the flow characteristics were analyzed under various temperature conditions, cement paste and the RMs exhibited similar tendencies in terms of flow characteristics. This indicated that the combinations of the selected materials could be used as RMs that can simulate the flow characteristics of cement paste with constant quality under various mixing ratio conditions and construction environment conditions.

Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method

  • Jeong, Yoo-Geum;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.245-251
    • /
    • 2018
  • PURPOSE. To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. MATERIALS AND METHODS. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). RESULTS. The RMS value ($152{\pm}52{\mu}m$) of the model manufactured by the milling method was significantly higher than the RMS value ($52{\pm}9{\mu}m$) of the model produced by the 3D printing method. CONCLUSION. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.