• 제목/요약/키워드: RMS Height

검색결과 91건 처리시간 0.026초

초소형 광 정보 저장 기기를 위한 광 경로 설계 및 마이크로 보정 렌즈 제작 (Design of Optical Path for Small Form Factor Optical Disk Drive and Fabrication of Micro-Compensatory Lens)

  • 김홍민;정경성;최우재;박노철;강신일;박영필
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.115-118
    • /
    • 2002
  • The purpose of this paper is to design a pick-up for the small form factor optical disk drive and to fabricate a micro-compensatory lens for the pick-up using the micro-compression molding process. At design stage, the optical elements including the objective lens and the compensatory lens are miniaturized. The height of pick-up and free working distance are designed as 2mm and 0.2% respectively. To analyze the fabricated micro-compensatory lens, the system was analyzed using the surface profile of the fabricated micro-compensatory lens and CODE V which is commercial software. The RMS wave front aberration of the system using fabricated micro-compensatory lens is 0.01677λ which is lower than Marechal's criterion, 0.07λ.

  • PDF

SPL에 의한 나노구조 제조 공정 연구 (Fabrication of nanometer scale patterning by a scanning probe lithography)

  • 류진화;김창석;정명영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.330-333
    • /
    • 2005
  • The fabrication of mold fur nano imprint lithography (NIL) is experimentally reported using the scanning probe lithography (SPL) technique, instead of the conventional I-beam lithography technique. The nanometer scale patterning structure is fabricated by the localized generation of oxide patterning on the silicon (100) wafer surface with a thin oxide layer, The fabrication method is based on the contact mode of scanning probe microscope (SPM) in air, The precision cleaning process is also performed to reach the low roughness value of $R_{rms}=0.084 nm$, which is important to increase the reproducibility of patterning. The height and width of the oxide dot are generated to be 15.667 nm and 209.5 nm, respectively, by applying 17 V during 350 ms.

  • PDF

A Semi-empirical Model for Polarimetric Radar Backscattering from Bare Soil Surfaces

  • Oh, Yi-Sok
    • 대한원격탐사학회지
    • /
    • 제17권2호
    • /
    • pp.141-153
    • /
    • 2001
  • A semi-empirical polarimetric backscattering model for bare soil surfaces is presented. Based on measurements by using polarimetric scatterometers and the JPL AirSAR, as well as the theoretical models, the backscattering coefficints $\sigma$$^0_w$, $\sigma$$^0_{hh}$ and $\sigma$$^0_{vh}$, and the parameters of the copolarized phase-difference probability density function, namely the degree of correlation $\alpha$ and the copolarized-phase-difference $\zeta$, are modeled empirically in terms of the volumetric soil moisture content m$_v$ and the surface roughness parameters $k_s$ and $k_l$, where k=2$\pi$f/c, s is the rms height and l is the correlation length.

Ergonomic Evaluation of Workload in Imbalanced Lower Limbs Postures

  • Kim, Eun-Sik;Yoon, Hoon-Yong
    • 대한인간공학회지
    • /
    • 제30권5호
    • /
    • pp.671-681
    • /
    • 2011
  • Objective: The purpose of this study is to compare the workload level at each lower limbs posture and suggest the ergonomic workstation guideline for working period by evaluating the imbalanced lower limbs postures from the physiological and psychophysical points of view. Background: Many workers like welders are working in various imbalanced lower limbs postures either due to the narrow working conditions or other environmental conditions. Method: Ten male subjects participated in this experiment. Subjects were asked to maintain 3 different lower limbs postures(standing, squatting and bending) with 3 different working conditions(balanced floor with no scaffold, imbalanced floor with 10cm height of scaffold, and imbalanced floor with 20cm height of scaffold). EMG data for the 4 muscle groups(Retus Femoris, Vastus Lateralis, Tibialis Anterior, Gastrocnemius) from each lower limbs posture were collected for 20 seconds every 2 minutes during the 8 minutes sustaining task. Subjects were also asked to report their discomfort ratings of body parts such as waist, upper legs, lower legs, and ankle. Results: The ANOVA results showed that the EMG root mean square(RMS) values and the discomfort ratings(CR-10 Rating Scale) were significantly affected by lower limbs postures and working time(p<0.05). The correlation was analyzed between the EMG data and the discomfort ratings. Also, prediction models for the discomfort rating for each posture were developed using physical condition, working time, and scaffold height. Conclusion: We strongly recommend that one should not work more than 6 minutes in a standing or squatting postures and should not work more than 4 minutes in a bending posture. Application: The results of this study could be used to design and assess working environments and methods. Furthermore, these results could be used to suggest ergonomic guidelines for the lower limbs postures such as squatting and bending in the working fields in order to prevent fatigue and pain in the lower limbs body.

요역동학 측정시스템을 위한 새로운 복압측정 기법 (A New Approach Method of Measuring Abdominal Pressure for Urodynamic Monitoring System)

  • 서정환;김거식;안양수;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1170-1176
    • /
    • 2007
  • The conventional urodynamic monitoring is fulfilled by artificially filling a bladder with saline. Generally. it is difficult to evaluate the physiological functions of the storage and voiding of a bladder. With this aim, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by measuring bio-impedance variations. Our system was clinically evaluated for 10 patients. It turned out to be that as the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased more as compared to those who observed during the rest mode. Also, we determined the optimum electrode pair for estimating the abdominal pressure using bio-impedance method and consequently compared with the conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified in terms of impedance change, correlation coefficient and SNR Our results showed the optimum electrode pair (1,9) which could detect impedance changes due to the increase of the intensity in the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. Thus, our system demonstrated that the abdominal pressure could be measured noninvasively and conveniently by simply estimating bio-impedance values. We propose that this optimum electrode configuration would be useful for the future studies involving the handy measurements of abdominal pressure with our suggested ambulatory urodynamics monitoring system.

상지운동 동안 복부에 적용된 압력 차이가 요부와 복부 근육 활성도에 미치는 영향 (Effect of Applied Pressure Differences to Abdomen on Lumbar and Abdominal Muscle Activation During Upper Limb Exercise)

  • 고은혜;윤혜선;신헌석;이강성
    • 대한물리치료과학회지
    • /
    • 제10권2호
    • /
    • pp.96-103
    • /
    • 2003
  • The purpose of this study was to assess the effect of applied pressure to abdomen on lumbar and abdominal muscle activation during upper limb exercise. The experimental group consisted of twenty-seven healthy male subjects (mean age=$22.40{\pm}2.19years$, mean height=$175.30{\pm}2.19cm$, mean weight= $67.67{\pm}7.44kg$, RM=$8.43{\pm}2.76kg$). In each different pressure condition (OmmHg, 30mmHg, 70mmHg, 100mmHg), upper limb exercise was performed in total of 10 trials with 10 RM dumb-bell exercise. Lumbar and abdominal muscle activity was measured using surface bipolar electrode electromyography(EMG). EMG activity was measured from upper rectus abdominis, external oblique abdominis, internal oblique abdominis, and elector spinae. The raw EMG signal was processed into the root mean square(RMS). All RMS EMG data were normalized and express as a percentage of the EMG(%EMG). Collected data were statistically analyzed by SPSS/PC Ver 10.0 using two-way analysis of variance for repeated measures($4{\pm}3$) and Bonferroni post hoc, test. Lumbar and abdominal muscle activation was significantly increased when 100 mmHg was applied(p<.05). Upper rectus abdominis activation was significantly increased compared as other muscles activation(p<.05). However, there were no interaction between pressure and muscles(p>.05). The findings of this study can be used as a fundamental data when lumbar orthosis is applied and external pressure can be used as a therapeutic tool.

  • PDF

제주도의 GPS/Levelling 지오이드와 PNU95 지오이드 (Comparison of GPS/Levelling Geoid with PNU95 Geoid in Cheju Island)

  • 최광선;박재희;홍순헌
    • 지구물리
    • /
    • 제3권1호
    • /
    • pp.13-24
    • /
    • 2000
  • 제주도 내의 13개의 수준점에서 GPS를 측정하였으며, 이에 의한 GPS/Levelling 지오이드와 PNU95 지오이드를 비교, 분석하여 보았다. GPS의 측정결과 각. 수준점의 타원체 높이를 ${\pm}3\;cm$ 이내의 정밀도로 측정하였다. 계산된 GPS/Levelling 지오이드는 제주도의 지형 변화를 잘 나타내고 있으며, 제주도에서 지오이드와 지형의 상관식은 다음과 같다. $$N\;=\;0.001082\;{\times}\;h\;+\;25.458\;{\pm}\;0.227\;s.d.$$ 계산된 GPS/Levelling 지오이드와 PNU95 지오이드는 잘 일치하고 있으며 두 지오이드의 RMS 차이는 0.14 m이다.

  • PDF

2차원저천단구조물(LCS)의 주변에서 불규칙파동장의 변동특성 (Variation Characteristics of Irregular Wave Fields around 2-Dimensional Low-Crested-Breakwater)

  • 이광호;최군호;이준형;정욱진;김도삼
    • 한국해안·해양공학회논문집
    • /
    • 제31권6호
    • /
    • pp.356-367
    • /
    • 2019
  • 본 연구는 olaFlow 모델에 의한 혼상류수치해석법을 적용하여 저천단구조물에 의한 불규칙파랑의 변동특성을 수치적으로 검토한다. 목표스펙트럼에 의한 불규칙파형과 측정된 불규칙파형과의 비교 및 이로부터 산정된 두 주파수스펙트럼의 비교로부터 olaFlow의 타당성을 검증하고, 2차원저천단구조물에 의한 불규칙파의 주파수스펙트럼의 변동, 파전달율, Hrms의 공간분포, 평균유속과 평균난류운동에너지의 공간분포 등을 수치적으로 검토한다. 이로부터 LCS 외해측의 전면에서 시계방향의 해빈류와 반시계방향의 순환류셀이 형성되고, 내해측의 정수면 근방에서 항내로 향하는 강한 일방향흐름이 발생되는 등의 중요한 결과를 얻을 수 있었다.

한국인 20대 남성의 NIOSH Lifting Equation 계수평가에 관한 연구 (A Study on the Evaluation of Horizontal, Vertical, Asymmetric and Coupling Multipliers of the NIOSH Lifting Equation in Korean Male)

  • 배동철;김용재
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.83-88
    • /
    • 2009
  • The objective of this paper was to evaluate the effectiveness of horizontal, vertical, asymmetric and coupling multipliers for manual material handling. Lifting tasks with 5 different horizontal distances ($30{\sim}70cm$) for 6 vertical distances(ankle, knee, waist, elbow, shoulder and head height) were experimented. The muscle activity and muscle exertion level during asymmetric load handling(without trunk flexion) was experimented. Lifting tasks with and without handle tote box for three postures(straight, bending, right angle posture) were experimented. The degrading tendency did not appeared almost in $60{\sim}70cm$ interval's horizontal distance. As a result of ANOVA, MVC paid attention to horizontal and vertical distance but cross effect was insignificant(p<0.01). The change of the MVC according to the horizontal, vertical distance appeared similar from of RWL. The results of normalized MVC measurement were decreased about 16%, 24%, 34% respectively as the asymmetry angle was $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. RMS EMG values of right erector spinae muscles were decreased as the work posture went to $90^{\circ}$ and those of left erector spinae muscles were increased until the asymmetry angle was $40^{\circ}$ but decreased continually over $40^{\circ}$. 7 subjects, activities of left and right latissimus dorsi muscles were maintained constantly, while for remainer, those were irregular. MVC reduced maximum 23% by type of handle. MVC was highest in straight posture, but was lowest in right angle posture. As a result of ANOVA, MVC paid attention to posture, coupling(p<0.01). To all handle types, biceps brachii activity was increased in right angle posture, but reduced in straight posture. Based on the results of this study, it is suggested that the NIOSH guideline should not be directly applied to Korean without reasonable reexamination. In addition, we need to afterward study through an age classification.

Double Gyre 모형 해양에서 앙상블 칼만필터를 이용한 자료동화와 쌍둥이 실험들을 통한 민감도 시험 (Implementation of the Ensemble Kalman Filter to a Double Gyre Ocean and Sensitivity Test using Twin Experiments)

  • 김영호;유상진;최병주;조양기;김영규
    • Ocean and Polar Research
    • /
    • 제30권2호
    • /
    • pp.129-140
    • /
    • 2008
  • As a preliminary effort to establish a data assimilative ocean forecasting system, we reviewed the theory of the Ensemble Kamlan Filter (EnKF) and developed practical techniques to apply the EnKF algorithm in a real ocean circulation modeling system. To verify the performance of the developed EnKF algorithm, a wind-driven double gyre was established in a rectangular ocean using the Regional Ocean Modeling System (ROMS) and the EnKF algorithm was implemented. In the ideal ocean, sea surface temperature and sea surface height were assimilated. The results showed that the multivariate background error covariance is useful in the EnKF system. We also tested the sensitivity of the EnKF algorithm to the localization and inflation of the background error covariance and the number of ensemble members. In the sensitivity tests, the ensemble spread as well as the root-mean square (RMS) error of the ensemble mean was assessed. The EnKF produces the optimal solution as the ensemble spread approaches the RMS error of the ensemble mean because the ensembles are well distributed so that they may include the true state. The localization and inflation of the background error covariance increased the ensemble spread while building up well-distributed ensembles. Without the localization of the background error covariance, the ensemble spread tended to decrease continuously over time. In addition, the ensemble spread is proportional to the number of ensemble members. However, it is difficult to increase the ensemble members because of the computational cost.