• Title/Summary/Keyword: RF testing

Search Result 121, Processing Time 0.019 seconds

Study on the stabilisateur of information transmission in RF-CBTC train control system using the FHSS system (FHSS방식을 채용한 RF-CBTC 열차제어시스템 정보 전송의 안정화에 관한 연구)

  • Oh, Sea-Hwa;Jin, Zhe-Huan;Lee, Key-Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.4
    • /
    • pp.455-468
    • /
    • 2014
  • This paper presents seamless hand off implementation suggesting algorithm and Measuring /testing at the tunnel environment in order to derive the ideal value of wireless data transmission in RF-CBTC train control system modeled by Shinbundang Operation System. In addition, it proposes the ideal value(-57dB) for reducing the re-transmission or frequency interference rate and demonstrates frequency optimization which enables highly reliable data communication in Train control system using wireless communications. Based on these result, Shinbundang phase 2 plan to apply to this system.

RF heating experiment to verify the design process of graphite target at the RAON µSR facility

  • Jae Young Jeong;Jae Chang Kim;Kihong Pak;Yong Hyun Kim;Yong Kyun Kim;Wonjun Lee;Ju Hahn Lee;Taek Jin Jang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3768-3774
    • /
    • 2023
  • The purpose of the target system for the muon spin rotation, relaxation, and resonance (µSR) facility at the Rare isotope Accelerator complex for ON-line experiments (RAON) is to induce the production of a significant number of surface muons in thermally stable experiments. The manufactured target system was installed at RAON in the Sindong area near Daejeon in 2021. The design was made conservatively with a sufficient margin of safety through ANSYS calculations; however, verification experiments had to be performed on the ANSYS calculations. Because the 600-MeV proton beam has not yet been provided, an alternative way to reproduce the calculation conditions was required. The radio frequency (RF) heating method, which has not yet been applied to the target verification experiment but has several advantages, was used. It was observed that the RF heating method has promise for testing the thermal stability of the target, and whether the target system design process was performed conservatively enough was verified by comparing the RF heating experiments with the ANSYS calculations.

Development of Frequency Discriminated Simulative Target Generator Based on DRFM for Radar System Performance Evaluation

  • Chung, Myung-Soo;Kim, Woo-Sung;Bae, Chang-Ok;Kang, Seung-Min;Park, Dong-Chul
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.213-219
    • /
    • 2011
  • Simulative target generators are needed for testing and calibrating various radar systems. The generator in this study discriminates the transmitting frequency from a radar and simulates parameters like target range, range rate, and atmospheric attenuation using the digital RF memory technique. The simulative target echo is then sent to the radar for testing and evaluation. This paper proposes a novel architecture for controlling the digital RF memory so it continually writes ADC data to the memory and reads it for the DAC with increasing one step address in order to control the delay of target range in a simple way. The target echo is programmed according to various preprogrammed scenarios and is generated in real time using a wireless local area network (LAN). To analyze the detected and generated target information easily, the system times for the radar and simulative target generator are synchronized using a global positioning system (GPS).

Cloning and Expression of Partial Japanese Flounder (Paralichthys olivaceus) IgD

  • Choi, Dae-Han;Jang, Han-Na;Ha, Dae-Mang;Kim, Jae-Wha;Oh, Chan-Ho;Choi, Sang-Hoon
    • BMB Reports
    • /
    • v.40 no.4
    • /
    • pp.459-466
    • /
    • 2007
  • The cDNA sequence of the Japanese flounder (Paralychthys olivaceus) IgD has been previously reported (GenBank accession no. AB052658) and this was followed by the detection of IgD mRNA expression in some flounder organ tissues. However, it has not been determined whether the flounder IgD gene is virtually expressed into IgD protein. To characterize the flounder immunoglobulins utilized in elucidating the mechanism, evolution and diversity of the flounder immune system, antibodies specific to IgD and IgM were necessary. In the present study, partial flounder recombinant IgD (rIgD), IgM (rIgM) and the conserved regions of IgD and IgM (rCIg) were produced by cloning the cDNA sequence using isotype specific primers which were designed to produce unique fragments of IgD and IgM specific amino acid sequences. The production of recombinant Igs was ascertained by SDS-gel electrophoresis and immunoblot analysis using anti-T7$\cdot}$Taq antibody. The produced recombinant Igs were purified using affinity columns, and used as immunogens. Antibodies specific to the isotype of flounder Igs were generated by immunizing rabbits with rfIgs and the antibodies produced were identified by enzyme-linked immunosorbent assay (ELISA) and immunoblotting. Specificities of the generated antibodies were evaluated by testing cross-reactivity between recombinant IgM and IgD. By ELISA, rabbit antibodies against the rfIgD fragment (anti-rfIgD) failed to recognize any kind of flounder serum Igs, whereas respective antibodies against rfCIg (anti-rfCIg) and rfIgM fragments (anti-rfIgM) reacted with serum Igs. Likewise, in immunoblot assays, though anti-rfIgD did not, both anti-rfCIg and anti-rfIgM bound with the ~85 kd flounder IgM heavy chain. By flow cytometry analysis, anti-rfCIg, anti-rfIgD and anti-rfIgM reacted with 6%, 3% and 6.5% of cells, respectively, suggesting that flounder IgD is not secreted in serum but expressed on flounder B-like cell surfaces as in mammals. Antibodies produced against recombinant flounder Igs could be used to develop sandwich assay systems for detecting flounder Igs and for further investigating the flounder immune system.

A Study on the Measurement of Anti-Cyclic Citrullinated Peptide (Anti-CCP) (Anti-Cyclic Citrullinated Peptide(Anti-CCP) 측정에 대한 연구)

  • Seo, Seol
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.42-48
    • /
    • 2007
  • This study was carried out to review and evaluate anti-CCP ELISA assay for diagnostic in RA patients from an early arthritis clinic (EAC). The subjects were obtained from patients visiting the outpatient clinic of the Dept. of Rhumatology med.of P hospital in Daegu, during 6 months from July 1, 2006 to December 31, 2006. The subjects were 140 cases : 80 cases from RA patients (60 women and 20 men; mean age 58 years; range, 32-68 years) confirmed by clinical diagnostic. 39 cases of these RA patients were classified as having early RA (EAC). 50 cases (non-RA) did not fulfill the criteria for RA, and 10 cases were from healthy individuals. We performed the analysis with solid phase-ELISA method (ETI-max3000, Diasorin; Italy) for anti-CCP and Nephelometry assay (Roche/Hitachi 902 analyzer; USA) for RF. The results obtained were summarized as follows ; anti-CCP ELISA is more specific than RF Nephelometry assay (specificity 94% vs 90%) to diagnose RA patients with suspected EAC (early arthritis clinic). The combination test "anti-CCP and RF" had a very high specificity (specificity 98.3%, PPV; RA group 96%, EAC 95%), the difference was statistically significant (p<0.05). Anti-CCP ELISA had more sensitivity in EAC (Early arthritis clinic) patients than chronic RA patients (sensitivity 64% vs 24%, respectively), anti-CCP of RA group and EAC group was more specific than RF (anti-CCP PPV; 92%, 89% vs 89%, 81% respectively), the difference was statistically significant (p<0.05). The difference of antibody concetration between anti-CCP and RF for RA and the control group is statistically significant (p<0.05). In conclusion, anti-CCP ELISA testing may be useful if performed concomitantly with RF Nephelometry assay to diagnose RA patients with suspected EAC (early arthritis clinic).

  • PDF

Improvement of Signal to Noise Ratio by Synthetic Aperture Focusing Technique in Ultrasonic Testing (집속 신호 합성 기법에 의한 초음파 탐상 신호 개선)

  • Lee, S.L.;Chang, K.O.;Kim, B.C.;Kim, G.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 1998
  • Nondestructive method can include both testing itself and analysis or evaluation of the testing results. Although vast amount of testing can be accomplished in a fairly short amount of time due to the advancement of electronic technology. it is really difficult matter to identify whether the indication found during testing corresponds to be a real defect. Thus, in ultrasonic testing, advanced digital signal processing techniques have been widely studied in order to identify the shape of the defect during testing, and one of the signal processing techniques, synthetic aperture focusing technique(SAFT) was tried for holes machined in carbon steel plate in this study. Result showed that signal to noise ratio has been improved considerably compared to the result from original RF signals.

  • PDF

A Study on the Stiffness of a 13degree-type Impact Tester for Aluminum Wheels (자동차용 휠(wheel)의 충격해석 신뢰도 향상을 위한 13도법 충격시험기의 강성 연구)

  • Ko, Kil-Ju;Kim, Man-Seob;Song, Hyun-Woo;Yang, Chang-Geun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.12-19
    • /
    • 2006
  • It is positively necessary to study on the stiffness of a 13degree-type impact tester in order to improve the fracture prediction of impact testing in wheels using FE(finite-element) analysis. The 13degree-type impact tester consists of an impact striker, a wheel fixer, a steel plate, and four cylindrical rubbers. Important parts of the tester are the steel plate and four cylindrical rubbers which play a role of absorbing impact energy during impact testing. Because of these buffers, the RF(reaction force) variation of the lower part in the 13degree-type impact tester showed the tendency like a damped harmony oscillation during impact testing. In order to investigate the stiffness of a 13degree-type impact tester, this work measured each stiffness of a steel plate and cylindrical rubbers. The stiffness of a cylindrical rubber was measured using a compressive tester. On the other hand, the stiffness of a steel plate was predicted by simulating experimental method using FE analysis.

Characteristic evaluations and production of triode magnetron sputtering system (Triode magnetron sputtering system의 제작 및 특성평가)

  • Kim, H.H.;Lee, M.Y.;Kim, K.T.;Yoon, S.H.;Yoo, H.K.;Kim, J.M.;Park, C.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.787-790
    • /
    • 2003
  • A rf triode magnetron sputtering system is designed and installed its construction in vacuum chamber. In order to calibrate the rf triode magnetron sputtering for thin films deposition processes, the effects of different glow discharge conditions were investigated in terms of the deposition rate measurements. The basic parameters for calibrating experiment in this sputtering system are rf power input, gas pressure, plasma current, and target-to-substrate distance. Because a knowledge of the deposition rate is necessary to control film thickness and to evaluate optimal conditions which are an important consideration in preparing better thin films, the deposition rates of copper as a testing material under the various sputtering conditions are investigated. Furthermore, a triode sputtering system designed in our team is simulated by the SIMION program. As a result, it is sure that the simulation of electron trajectories in the sputtering system is confined directly above the target surface by the force of $E{\times}B$ field. Finally, some teats with the above 4 different sputtering conditions demonstrate that the deposition rate of rf triode magnetron sputtering is relatively higher than that of the conventional sputtering system. This means that the higher deposition rate is probably caused by a high ion density in the triode and magnetron system. The erosion area of target surface bombarded by Ar ion is sputtered widely on the whole target except on both magnet sides. Therefore, the designed rf triode magnetron sputtering is a powerful deposition system.

  • PDF

Implementation of 5.0GHz Wide Band RF Frequency Synthesizer for USN Sensor Nodes (USN 센서노드용 5.0GHz 광대역 RF 주파수합성기의 구현)

  • Kang, Ho-Yong;Kim, Se-Han;Pyo, Cheol-Sig;Chai, Sang-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.4
    • /
    • pp.32-38
    • /
    • 2011
  • This paper describes implementation of the 5.0GHz RF frequency synthesizer with 0.18${\mu}m$ silicon CMOS technology being used as an application of the IEEE802.15.4 USN sensor node transceiver modules. To get good performance of speed and noise, design of the each module like VCO, prescaler, 1/N divider, fractional divider with ${\Sigma}-{\Delta}$ modulator, and common circuits of the PLL has been optimized. Especially to get excellent performance of high speed and wide tuning range, N-P MOS core structure and 12 step cap banks have been used in design of the VCO. The chip area including pads for testing is $1.1{\times}0.7mm^2$, and the chip area only core for IP in SoC is $1.0{\times}0.4mm^2$. Through analysing of the fabricated frequency synthesizer, we can see that it has wide operation range and excellent frequency characteristics.

Implementation of 1.9GHz RF Frequency Synthesizer for USN Sensor Nodes (USN 센서노드용 1.9GHz RF 주파수합성기의 구현)

  • Kang, Ho-Yong;Kim, Nae-Soo;Chai, Sang-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.5
    • /
    • pp.49-54
    • /
    • 2009
  • This paper describes implementation of the 1.9GHz RF frequency synthesizer with $0.18{\mu}m$ silicon CMOS technology being used as an application of the USN sensor node transceiver modules. To get good performance of speed and noise, design of the each module like VCO, prescaler, 1/N divider, fractional divider with ${\Sigma }-{\Delta}$ modulator, and common circuits of the PLL has been optimized. Especially to get good performance of speed, power consumption, and wide tuning range, N-P MOS core structure has been used in design of the VCO. The chip area including pads for testing is $1.2{\times}0.7mm^2$, and the chip area only core for IP in SoC is $1.1{\times}0.4mm^2$. The test results show that there is no special spurs except -63.06dB of the 6MHz reference spurs in the PLL circuitry. There is good phase noise performance like -116.17dBc/Hz in 1MHz offset frequency.