• Title/Summary/Keyword: RF noise

Search Result 623, Processing Time 0.029 seconds

Direct Time-domain Phase Correction of Dual-comb Interferograms for Comb-resolved Spectroscopy

  • Lee, Joohyung
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.289-297
    • /
    • 2021
  • We describe a comb-mode resolving spectroscopic technique by direct time-domain phase correction of unstable interferograms obtained from loosely locked two femtosecond lasers. A low-cost continuous wave laser and conventional repetition rate stabilization method were exploited for locking carrier and envelope phase of interferograms, respectively. We intentionally set the servo control at low bandwidth, resulting in severe interferograms' fluctuation to demonstrate the capability of the proposed correction method. The envelope phase of each interferogram was estimated by a quadratic fit of carrier peaks to correct timing fluctuation of interferograms in the time domain. After envelope phase correction on individual interferograms, we successfully demonstrated 1 Hz linewidth of RF comb-mode over 200 GHz optical spectral-bandwidth with 10-times signal-to-noise ratio (SNR) enhancement compared to the spectrum without correction. Besides, the group delay difference between two femtosecond pulses is successfully estimated through a linear slope of phase information.

A Study on Microwave Self Oscillating Mixer Using Ga As MESFET (GaAs MESFET를 이용한 초고주파 자체발진 혼합기에 관한 연구)

  • Kwon, Dong Seung;Chae, Jong Seok;Park, Han Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.3
    • /
    • pp.413-419
    • /
    • 1987
  • In this paper, self-oscillating mixer is designed by small signal S-parameter and series feedback circuit. The input-output matching circuit is accomplished from double stub and additional matching stub. The self-oscillating mixer is oscillating itself and amplifies without any external local oscillator and an intermediate frequency amplifier, so it has advantages in its economical and system simplification. The experimental results show the maximum conversion gain 1.5d B and the noise figure 6.5d B at RF center frequency 4GHz and IF 1.1GHz` output oscillating power 4d Bm, efficiency 13.4%, stability -10MHz/V and -0.5MHz/\ulcornerC at oscillating frequency 5.1GHz.The rejection band loss characteristics in band pass filter and low pass filter are -40d B and -30d B, respectively.

  • PDF

Localization of a Mobile Robot Using Ceiling Image with Identical Features (동일한 형태의 특징점을 갖는 천장 영상 이용 이동 로봇 위치추정)

  • Noh, Sung Woo;Ko, Nak Yong;Kuc, Tae Yong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.160-167
    • /
    • 2016
  • This paper reports a localization method of a mobile robot using ceiling image. The ceiling has landmarks which are not distinguishablefrom one another. The location of every landmark in a map is given a priori while correspondence is not given between a detected landmark and a landmark in the map. Only the initial pose of the robot relative to the landmarks is given. The method uses particle filter approach for localization. Along with estimating robot pose, the method also associates a landmark in the map to a landmark detected from the ceiling image. The method is tested in an indoor environment which has circular landmarks on the ceiling. The test verifies the feasibility of the method in an environment where range data to walls or to beacons are not available or severely corrupted with noise. This method is useful for localization in a warehouse where measurement by Laser range finder and range data to beacons of RF or ultrasonic signal have large uncertainty.

Radiofrequency Coil Design for in vivo Sodium Magnetic Resonance Imaging of Mouse Kidney at 9.4T

  • Lim, Song-I;Woo, Chul-Woong;Kim, Sang-Tae;Choe, Bo-Young;Woo, Dong-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.65-70
    • /
    • 2018
  • The objective of this study was to describe a radiofrequency (RF) coil design for in vivo sodium magnetic resonance imaging (MRI) for use in small animals. Accumulating evidence has indicated the importance and potential of sodium imaging with improved magnet strength (> 7T), faster gradient, better hardware, multi-nucleus imaging methods, and optimal coil design for patient and animal studies. Thus, we developed a saddle-shaped sodium volume coil with a diameter/length of 30/30 mm. To evaluate the efficiency of this coil, bench-level measurement was performed. Unloaded Q value, loaded Q value, and ratio of these two values were estimated to be 352.8, 211.18, and 1.67, respectively. Thereafter, in vivo acquisition of sodium images was performed using normal mice (12 weeks old; n = 5) with a two-dimensional gradient echo sequence and minimized echo time to increase spatial resolution of images. Sodium signal-to-noise ratio in mouse kidneys (renal cortex, medulla, and pelvis) was measured. We successfully acquired sodium MR images of the mouse kidney with high spatial resolution (approximately 0.625 mm) through a combination of sodium-proton coils.

Characteristics of PLT Thin Films on MgO Substrates and Fabrication of Infrared Sensor (MgO 기판 위에 올린 PLT 박막의 특성과 적외선 센서의 제작)

  • Cho, Sung-Hyun;Jung, Jae-Mun;Lee, Jae-Gon;Kim, Ki-Wan;Hahm, Sung-Ho;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.188-193
    • /
    • 1997
  • The lanthanum-modified lead titanate (PLT) thin films on (100) cleaved MgO single crystal substrate have been prepared by RF magnetron sputtering method using PbO-rich target with varing La contents. The substrate temperature, working pressure, $Ar/O_{2}$, and RF power density of PLT thin films were $580^{\circ}C$ 10mTorr, 10/1, and $1.7W/cm^{2}$, respectively. In these conditions, the c-axis growth and tetragonality of the PLT thin films decreased for addition of La content and the PLT thin films showed diffuse phase transition from high temperature XRD patterns. The infrared sensor was fabricated. The remanent polarization was above $1.71{\mu}C/cm^{2}$ and the pyroelectric voltage was above 500mV with 10:1 signal to noise ratio.

  • PDF

Performance Analysis of RF Transformation in DS/CDMA Receiver (DS/CDMA수신기에서 RF변환부의 성능분석)

  • Pyeon, Suk-Bum;Ju, Jae-Han
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.2
    • /
    • pp.86-92
    • /
    • 1998
  • In this paper, it is derived the system design parameters for the J-STD-018 of the PCS mobile station(MS) minimum performance using DS/CDMA analyzed the system performance due to the receiver components. The simulation shows the selectivity is -70.96dB at 1.25MHz frequency offset from the carrier frequency while the MS noise figure to satisfy J-STD-018 is 10dB and the input 3rd harmonics intercept point of the MS class I and MS class II-V is -9.5dBm and -14dBm respectively. When the interference power level at the receiver is small, the receiver has better performance as we increase the gain of LNA. However, when the interference level at the receiver is large, the receiver performance is decreased by the effect of the spurious. Thus, the effectiveness of LNA On/Off switching technique is proved as to reduce the effect of the spurious.

  • PDF

Development of an SIS(Superconductor-Insulator-Superconductor) Junction Mixer over 120∼180 GHz Band (120∼180 GHz 대역 SIS (Superconductor-Insulator-Superconductor) 접합 믹서의 개발)

  • Chung, Moon-Hee;Lee, Changhoon;Kim, Kwang-Dong;Kim, Hyo-Ryoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.8
    • /
    • pp.737-743
    • /
    • 2004
  • A fixed-tuned SIS(Superconductor-Insulator-Superconductor) mixer across 120∼180 GHz band has been developed. This mixer employs an SIS chip fabricated by Nobeyama radio observatory which consists of a series array of 6 Nb/Al-Al$_2$O$_3$/Nb junctions in a microstrip line on a fused quartz substrate. The SIS chip is placed at the center of the half-height waveguide mixer mount to have a good incoming signal coupling over the whole frequency band. No mechanical tuner was used in the SIS mixer and the RF signal and local oscillator power are injected to the mixer via a cooled cross-guide coupler. In order to prevent the IF signal loss, the If output impedance of the SIS mixer was matched to the 50 $\Omega$ input impedance of the IF chain. Measured double sideband noise temperatures of a receiver using the SIS mixer are 32∼131 K over 120∼180 GHz band. The developed SIS mixer is now in use for radio astronomical observations on the TRAO 14 m radio telescope.

Real-Time Respiration and Heartbeat Detector Using a Compact 1.6 GHz Single-Channel Doppler Sensor (소형화된 1.6 GHz 단일 채널 도플러 센서를 이용한 실시간 호흡 및 심장 박동 감지기)

  • Lee, Hyun-Woo;Park, Il-Ho;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.379-388
    • /
    • 2007
  • This paper presents a real-time respiration and heartbeat detector comprised of a 1.6 GHz single-channel Doppler sensor and analog/digital signal processing block for remote vital sign detection. The RF front end of the Doppler sensor consists of an oscillator, mixer, low noise amplifier, branch-line hybrid and patch antenna. We apply artificial transmission lines(ATLs) to the branch-line hybrid, which leads to a size reduction of 40 % in the hybrid, while its performance is very comparable to that of a conventional hybrid. The analog signal conditioning block is implemented using second order Sallen-Key active filters and the digital signal processing block is realized with a LabVIEW program on a computer. The respiration and heartbeat detection is demonstrated at a distance of 50 cm using the developed system.

Hybrid Balanced VCO Suitable for Sub-1V Supply Voltage Operation (1V 미만 전원전압 동작에 적합한 혼성 평형 전압제어 발진기)

  • Jeon, Man-Young;Kim, Kwang-Tae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.715-720
    • /
    • 2012
  • This study presents a hybrid balanced voltage controlled oscillator (VCO) circuit which is suitable for low phase noise operation at sub-1V supply voltages. Half circuits of the proposed VCO use the varactor-integrated feedback capacitors in their respective circuit. The varactor-integrated feedback capacitors further increase the negative resistance of the equivalent tank thereby ensuring stable start-up of oscillation even at the sub-1V supply voltage. In addition, this work theoretically analyses the phenomenon of the increase of the negative resistance. Simulation results using a $0.18{\mu}m$ RF CMOS technology exhibit the phase noises of -122.4 to -125.5.8 dBc/Hz at 1 MHz offset from oscillation frequency of 4.87 GHz over the supply voltages of 0.6 through 0.9 V.

Design of RF Digital Spectrum Analyser for Mobile Communication (이동 통신용 RF 디지털 스펙트럼 분석기 설계)

  • Woo, Kwang-Joon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.29-34
    • /
    • 2007
  • It is important to analyse the frequency spectrum for the measurement of modulated signal, distortion, and noise. The frequency spectrum analysis is performed by the execution of Radix-2 DIT DFT i.e. FFT algorithm. The discrete input signal converted by A/D converter from the input signal in time domain is mathematically transformed to the frequency spectrum by FFT algorithm. In this study, we design the digital spectrum analyser by the hardware based on the TMS320F2812 DSP and AD9244 converter, and by the software based on the C28x S/W modules. We can timely analyse the frequency spectrum in mobile communication system by the digital frequency analyser based on the high performance DSP and S/W modules. This real-time analysing capability is the important performance in the internet-based mobile communication server system.