• 제목/요약/키워드: RF Scanner

검색결과 16건 처리시간 0.019초

Measurements of Dark Area in Sensing RFID Transponders

  • Kang, J.H.;Kim, J.Y.
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.103-108
    • /
    • 2012
  • Radiofrequency(RF) signal is a key medium to the most of the present wireless communication devices including RF identification devices(RFID) and smart sensors. However, the most critical barrier to overcome in RFID application is in the failure rate in detection. The most notable improvement in the detection was from the introduction of EPC Class1 Gen2 protocol, but the fundamental problems in the physical properties of the RF signal drew less attention. In this work, we focused on the physical properties of the RF signal in order to understand the failure rate by noting the existence of the ground planes and noise sources in the real environment. By using the mathematical computation software, Maple, we simulated the distribution of the electromagnetic field from a dipole antenna when ground planes exist. Calculations showed that the dark area can be formed by interference. We also constructed a test system to measure the failure rate in the detection of a RFID transponder. The test system was composed of a fixed RFID reader and an EPC Class1 Gen2 transponder which was attached to a scanner to sweep in the x-y plane. Labview software was used to control the x-y scanner and to acquire data. Tests in the laboratory environment showed that the dark area can be as much as 43 %. One who wants to use RFID and smart sensors should carefully consider the extent of the dark area.

드론탐지용 RF스캐너의 성능에 송전탑이 미치는 영향 분석 (Analysis of the Impact of Transmission Towers on the Performance of RF Scanners for Drone Detection)

  • 이문희;방정주
    • 한국ITS학회 논문지
    • /
    • 제23권1호
    • /
    • pp.112-122
    • /
    • 2024
  • 최근 드론과 같은 무인비행장치 기술이 발전함에 따라 환경적, 사회적 및 경제적으로 많은 이점이 있지만, 공항, 공공기관, 발전소, 군 등 국가중요시설에 악의적인 의도를 가질 경우 국가 안전과 국민 생활에 심각한 피해를 줄 수 있다. 이러한 드론의 위협에 대응하기 위해 RF스캐너와 같은 탐지 장비 도입을 시도하고 있다. 특히 변전소, 발전소, 우리나라 전력 계통에 의해 설치된 전력 전송용 송전탑은 RF스캐너 탐지 경로에 송전탑이 위치하면 탐지 성능에 영향을 줄 수 있다. 실험은 상용 드론을 이용하여 드론에서 방사되는 신호 세기 측정하여 감쇠율을 확인하였다. 평균 감쇠율과 최대 감쇠율은 2.4 GHz와 5.8 GHz 대역에서 유사한 경향을 보였고, 구조물의 밀도에도 영향을 받는 것을 알 수 있다.

생약복합제제(生藥複合製劑)의 품질관리(品質管理)에 관(關)한 연구(硏究)(제1보)(第1報) -TLC Scanner에 의(依)한 삼요탕(三拗湯)의 품질관리(品質管理)- (Studies on the Quality Control Method of Crude Drug Preparations (I) -Studies on the Quality Control by the TLC Profiles Analysis of ‘Samyo-Tang’-)

  • 홍남두;김종우;김남재;손정곤
    • 생약학회지
    • /
    • 제12권3호
    • /
    • pp.119-124
    • /
    • 1981
  • In our country, in order to cure diseases, a large number of crude drug preparations has been available. Nevertheless, the development of crude drug preparations have been inhibited, because the quality control is not completed so far. Therefore, we have eontinued on studing the quality control method by Zig-zag TLC. profile analysis. The water extract of 'Samyo-Tang' and componental crude drug (Glycyrrhizae Radix, Ephedrae Herba, Armenicae Semen) were developed on Silica gel $60F_{254}\;plate\;(E.\;Merck)$ useing elution solvent. The developed plate were examined useing Dual Wavelength Zig-zag Scanner (Shimadzu). According to the results of the experiment, it could be summarized as follow: 1) Original patterns of TLC profiles of 'Samyo-Tang' componental crude drug and mixing two crude drugs of 'Samyo-Tang' were observed. 2) Original patterns TLC profile of each extract after spraying with 2% ninhydrine were observed. 3) In the extract of addition and subtraction of Ephedrae Herba, peak area of Rf 0.48 and Rf 0.60 were varied quantitatively.

  • PDF

Microwave and RF Heating for Medical Application under Noninvasive Temperature Measurement Using Magnetic Resonance

  • Nikawa, Yoshio;Ishikawa, Akira
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.244-249
    • /
    • 2010
  • Recent development of magnetic resonance imaging (MRI) equipment enables interventional radiology (IVR) as diagnosis and treatment under MRI usage. In this paper, a new methodology for magnetic resonance (MR) scanner to apply not only diagnostic equipment but for treatment one is discussed. The temperature measuring procedure under MR is to measure phase shift of $T_1$, which is the longitudinal relaxation time of proton, for the position inside a sample material with the application of pulsed RF for heating inside the sample as artificial dielectrics. The result shows the possibility to apply MR as temperature measuring equipment and as a heating equipment for applying such as hyperthermia heating modality.

임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발 (Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner)

  • 김은주;김대홍;이상우;허단;이영한;서진석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.52-58
    • /
    • 2014
  • 목적: 임상용 MRI에서 마우스 종양의 pH 측정을 위한 $^1H-^{31}P$ RF 코일 시스템을 개발하고 팬텀을 이용하여 pH 값의 정확도를 시험하고자 한다. 대상과 방법: 마우스 종양 연구를 위한 표면형 $^1H$$^{31}P$ radio frequency (RF) 코일을 개발하였다. 두 코일을 서로 수직이 되도록 설치하여 두 코일간의 상호인덕턴스를 0으로 하였다. 다양한 pH 값을 가진 팬텀으로부터 $^{31}P$ MR 스펙트럼을 얻어 Henderson-Hasselbalch equation을 이용하여 pH를 구하였다. $^{31}P$ 스펙트럼으로부터 얻은 pH값은 pH meter를 사용하여 직접 구한 pH값과 비교한다. 결과: $^1H-^{31}P$ RF 코일 상호간 coil coupling (S12)은 각각 -73.0, -62.3 dB로 충분히 분리 되었다. 균일한 팬텀으로부터 얻은 $^1H$ 영상의 signal-to-noise ratio (SNR)는 약 300 이상이며, in vivo 고해상도 마우스 영상을 얻을 수 있었다. $^1H$ 신호가 분리된 $^{31}P$ MR 스펙트럼으로부터 얻은 pH값은 pH meter로 직접 측정하여 얻은 값과 약 97% 상관관계를 가졌다. 결론: 본 연구에서 개발한 임상 MRI 장비용 $^1H-^{31}P$ RF 코일 시스템으로부터 정확한 pH를 구할 수 있었다. 본 코일 시스템은 31P 이외의 다른 핵 MRS 혹은 MRI에 적용 가능할 것으로 기대된다.

Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays

  • Huang, Shaoying;Ren, Zhi Hua;Obruchkov, Sergei;Gong, JIa;Dykstra, Robin;Yu, Wenwei
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.179-201
    • /
    • 2019
  • Portable low-cost magnetic resonance imaging (MRI) systems have the potential to enable "point-of-care" and timely MRI diagnosis, and to make this imaging modality available to routine scans and to people in underdeveloped countries and areas. With simplicity, no maintenance, no power consumption, and low cost, permanent magnets/magnet arrays/magnet assemblies are attractive to be used as a source of static magnetic field to realize the portability and to lower the cost for an MRI scanner. However, when taking the canonical Fourier imaging approach and using linear gradient fields, homogeneous fields are required in a scanner, resulting in the facts that either a bulky magnet/magnet array is needed, or the imaging volume is too small to image an organ if the magnet/magnet array is scaled down to a portable size. Recently, with the progress on image reconstruction based on non-linear gradient field, static field patterns without spatial linearity can be used as spatial encoding magnetic fields (SEMs) to encode MRI signals for imaging. As a result, the requirements for the homogeneity of the static field can be relaxed, which allows permanent magnets/magnet arrays with reduced sizes, reduced weight to image a bigger volume covering organs such as a head. It offers opportunities of constructing a truly portable low-cost MRI scanner. For this exciting potential application, permanent magnets/magnet arrays have attracted increased attention recently. A magnet/magnet array is strongly associated with the imaging volume of an MRI scanner, image reconstruction methods, and RF excitation and RF coils, etc. through field patterns and field homogeneity. This paper offers a review of permanent magnets and magnet arrays of different kinds, especially those that can be used for spatial encoding towards the development of a portable and low-cost MRI system. It is aimed to familiarize the readers with relevant knowledge, literature, and the latest updates of the development on permanent magnets and magnet arrays for MRI. Perspectives on and challenges of using a permanent magnet/magnet array to supply a patterned static magnetic field, which does not have spatial linearity nor high field homogeneity, for image reconstruction in a portable setup are discussed.

Emittance Measurements of the Ion Sources for Induction Linac Driven Heavy Ion Fusion

  • Lee, Heon-Ju
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.181-185
    • /
    • 1997
  • The ion sources for induction linac driven heavy ion fusion were fabricated and their omittance characteristics were investigated. For to kinds of ion sources, i. e. a carbon vacuum arc ion source and a cusp field rf ion source, the emittance was measured with a double slit beam scanner. The required normalized omittance of an ion source for heavy ion fusion is 10$^{-7}$ - 5$\times$10$^{-7}$ $\pi$ m-rod, and the measured emittances of the ion beams from carbon vacuum arc ion source and cusp field rf ion source (Ne$^{+}$) were 2$\times$10$^{-6}$ $\pi$ m-rad and 4$\times$10$^{-7}$ $\pi$ m-rad, respectively.y.

  • PDF

PRAM을 위한 Si-doped Ge2Sb2Te5 박막의 상변화 특성 연구 (A Study on the Phase Change Characteristics of Si-doped Ge2Sb2Te5 Thin Films for PRAM)

  • 백승철;송기호;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.261-266
    • /
    • 2010
  • In this paper, we report the changes of electrical, structural and optical characteristics in $Ge_2Sb_2Te_5$ thin films according to an increase of Si content. The Si-doped $Ge_2Sb_2Te_5$ thin films were prepared by rf-magnetron co-sputtering method. Isothermal annealing was carried out at $N_2$ atmosphere. The crystallization speed (v) of amorphous thin films was evaluated by detecting the reflection response signals using a nano-pulse scanner (wavelength = 658 nm) with illumination power of 1~17 mW and pulse duration of 10~460 ns. Structural phase changes were evaluated by XRD, and the optical transmittance was measured in the wavelength range of 300~3000 nm using UV-vis-NIR spectrophotometer. The sheet resistance (RS) of the thin films was measured using 4 point probe. Conclusivlely, the v-value decreased with an increase of Si content, while the RS-values of both crystalline and amorphous phases were increased. In particular, fcc-to-hexagonal transition was suppressed by the added Si atoms.

적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법 (Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter)

  • 박호동;장봉렬;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T (Effective of Body Temperature Increasing during Brain MRI scan)

  • 김명성;이종웅;정재은
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.49-54
    • /
    • 2017
  • MRI장비에서 자장의 세기가 증가 하게 되면 사용하는 RF(Radiofrequency) pulse 또한 증가 하게 되고 이는 MRI 장비 안에 놓인 인체의 체온 상승을 증가 시키게 하는 역할을 하게 된다. 이에 국소부위에서의 열 발생을 알아보고자 젤라틴과 pork sample 이용하여 측정하였다. 본 연구는 2014년 12월 21일부터 2015년 8월 14일까지 153명의 환자를 대상으로 실시하였다. 3대의 MRI(1.5T- 1대, 3.0T- 2대)장비를 사용하여 뇌 또는 간 부위에서 일상적으로 쓰이는 sequence 프로토콜을 동일하게 적용하여 검사하였다. 검사 전 후 체온 측정은 적외선 타입의 귀 체온계(Braun社)를 사용하였으며 대상자의 심리적 상태는 직접 설문을 통하여 파악했다. 임상 환자를 대상으로 한 체온 상승 결과를 보면 3.0T가 1.5T에서보다 평균 $0.15^{\circ}C$정도 높았고(p<0.012) 3.0T내 에서도 Philips제조회사에서 보다 GE社 MRI장비에서 $0.14^{\circ}C$정도 더 높았다. 심인성 상태에 따른 결과를 살펴보면 MRI검사 진행 중 나는 소리에 대한 민감성 정도와 체온상승과의 관계는 무관하였고, 폐쇄성에 대한 응답이 긴장감으로 느꼈다고 대답하는 사람일수록 체온이 더 상승하는 경향을 보였다. 자장의 세기가 높은 MRI장비일수록 RF 반응물질(물, 금속물질)에 의한 화상이나 체온상승으로 인한 위험한 상황발생(체온조절 장해 환자의 경우 고온 손상, 과다 땀 발생으로 인한 탈진)이 나타나지 않도록 환자의 상태를 좀 더 예의 주시하며 MRI검사를 진행할 필요가 있겠다. 높은 자기장을 기반으로 한 MRI장비는 인체에 흡수되는 전자파 흡수율인 SAR를 비례적으로 증가시키므로 앞으로는 RF 코일 성능을 향상하거나 영상의 질을 향상시키기 위한 이미지 프로그램을 개발하는 등 자기장 이외의 방법을 강구하는 것이 필요하다.