The design considerations of steel braced frame for seismic retrofit through increasing the lateral strength of existing RC buildings (철골브레이스에 의한 기존 RC건축물의 강도상승형 내진보강을 위한 설계고려사항)

  • Ahn, Choong Weon;Yoon, Jeong Hwan;Song, Dong Yub;Chang, Buhm Soo;Min, Chan Gi
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.293-303
    • /
    • 2013
  • This paper deals with steel braced frame as increasing the lateral strength and ductility in order to seismic retrofit of existing buildings and discusses the designing criteria and calculation method of retrofitted buildings. The addition of steel braced frame can be effective for increasing the lateral strength and ductility of existing buildings. However, There is a problem in utilizing this method. It is the approach to provide an adequate connection between the existing RC frame and the installed steel braced frame, because global strength by failure mode(three type) depends on detail of connection and strength of existing RC frame. So, the designer must be confirmed if it satisfies the required performance or not. Failure mode of type I is the most appropriate for increasing the lateral strength and ductility. Seismic performance evaluation and strength calculation of seismic retrofit are performed by guideline by KISTEC(Korea Infrastructure Safety & Technology)'s "seismic performance evaluation and rehabilitation of existing buildings" and Japan Building Disaster Prevention Association. Buildings are modeled and non-linear pushover analysis are performed using MIDAS program.

Seismic response of current RC buildings in Kathmandu Valley

  • Chaulagain, Hemchandra;Rodrigues, Hugo;Spacone, Enrico;Varum, Humberto
    • Structural Engineering and Mechanics
    • /
    • v.53 no.4
    • /
    • pp.791-818
    • /
    • 2015
  • RC buildings constitute the prevailing type of construction in earthquake-prone region like Kathmandu Valley. Most of these building constructions were based on conventional methods. In this context, the present paper studied the seismic behaviour of existing RC buildings in Kathmandu Valley. For this, four representative building structures with different design and construction, namely a building: (a) representing the non-engineered construction (RC1 and RC2) and (b) engineered construction (RC3 and RC4) has been selected for analysis. The dynamic properties of the case study building models are analyzed and the corresponding interaction with seismic action is studied by means of non-linear analyses. The structural response measures such as capacity curve, inter-storey drift and the effect of geometric non-linearities are evaluated for the two orthogonal directions. The effect of plan and vertical irregularity on the performance of the structures was studied by comparing the results of two engineered buildings. This was achieved through non-linear dynamic analysis with a synthetic earthquake subjected to X, Y and $45^{\circ}$ loading directions. The nature of the capacity curve represents the strong impact of the P-delta effect, leading to a reduction of the global lateral stiffness and reducing the strength of the structure. The non-engineered structures experience inter-storey drift demands higher than the engineered building models. Moreover, these buildings have very low lateral resistant, lesser the stiffness and limited ductility. Finally, a seismic safety assessment is performed based on the proposed drift limits. Result indicates that most of the existing buildings in Nepal exhibit inadequate seismic performance.

Evaluation of Seismic Design Force by Earthquake Response Analysis of Water Tanks Installed in RC Buildings (건축물에 설치된 물탱크의 지진응답해석을 통한 설계하중 평가)

  • Baek, Eun Rim;Oh, Ji Hyeon;Choi, Hyoung Suk;Lee, Sang Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.221-229
    • /
    • 2019
  • Several water tanks installed in the building were damaged during the Gyeongju earthquake (2016) and the Pohang earthquake (2017). Since a water tank for fire protection is very important component, seismic safety should be ensured. In this study, an interaction between a water tank and a building was studied by the dynamic analysis of the RC building with the water tank. In case the water tank was installed on the roof of the RC building, it was confirmed that it did not significantly affect the response of the building. Based on the result, dynamic response characteristics of the water tank in the building were studied using two SDOF models represented dynamic behavior of the water tanks under earthquake. An earthquake time-history analysis was carried out with variables of aspect ratio of the tank, story of the building, and installed location in the building using three kinds of earthquakes.

Design of High Performance Reinforced Concrete Pile for Improvement of Seismic Performance (내진성능 향상을 위한 고성능 철근콘크리트 말뚝 설계에 관한 연구)

  • Park, Chan Sik;Cho, Jeong-Rae;Kim, Young Jin;Chin, Won Jong;Yoon, Hyejin;Choi, Myung Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.183-190
    • /
    • 2019
  • Recent changes in the construction method of piles to minimize noise, along with the development of high-strength reinforcement, have provided an economical high performance RC pile development to compensate for the disadvantages of existing PHC piles. In this study, a methodology for the development of cross - section details of high performance RC piles of various performances is presented by freely applying high strength steel and concrete. This study suggested a technique for calculating bending moments for a given axial force corresponding to the allowable crack widths and this can be used for serviceablity check. In calculating the design shear force, the existing design equation applicable to the rectangular or the I section was modified to be applicable to the hollow circular section. In particular, in the limit state design method, the shear force is calculated in proportion to the axial force, and the procedure for calculating PV diagram is established. Last, the section details are determined through PM diagrams that they have the similar flexural and axial-flexural performances of the PHC pile A, B and C types with a diameter of 500 mm. To facilitate the application of the selected standard sections to the practical tasks, the design PM diagram and design shear forces are proposed in accordance with the strength design method and limit state design method.

Seismic Performance Evaluation of Unreinforced Masonry Walls with Additional Boundary RC Frames (RC 경계골조를 설치한 신축 비보강 조적벽체의 내진성능 평가)

  • You, Young-Chan;Kim, Min-Sun;Lee, Hyun-Jee
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.27-35
    • /
    • 2018
  • The purpose of this study is to examine the effects of boundary RC frame(composed of one tie-beam and two tie-columns) on seismic performance of unreinforced masonry walls to suggest alternative way for seismic design of unreinforced masonry wall structures. Two test specimens are prepared, one is a typical unreinforced masonry wall and another is alternative unreinforced masonry wall with additional boundary RC frame. The structural experiments were carried out to evaluate the difference of seismic resistance performance between two test specimens with or without the boundary RC frames. From the test results, it was found that the failure mode of unreinforced masonry wall fundamentally changed from 'brittle' to 'ductile' by the installing of boundary RC frames. And, the maximum load and energy dissipation capacity of the test specimen with boundary RC frame was increased about 1.6~1.7 and 2~3 times respectively compared with a typical unreinforced masonry wall specimen.

Seismic performance evaluation of a three-dimensional unsymmetrical reinforced concrete building

  • Lim, Hyun-Kyu;Kang, Jun Won;Lee, Young-Geun;Chi, Ho-Seok
    • Multiscale and Multiphysics Mechanics
    • /
    • v.1 no.2
    • /
    • pp.143-156
    • /
    • 2016
  • Reinforced concrete (RC) structures require advanced analysis techniques for better estimation of their seismic responses, especially in the case of exhibiting complex three-dimensional coupling of torsional and flexural behaviors. This study focuses on validating a numerical approach for evaluating the seismic response of a three-dimensional unsymmetrical RC structure through the participation in the SMART 2013 international benchmark program. The benchmark program provides material properties, detailed drawings of the RC structure, and input ground motions for the seismic response evaluation. In this study, nonlinear constitutive models of concrete and rebar were formed and local tests were conducted to verify the constitutive models in finite element analysis. Elastic calibration of the finite element model of the SMART 2013 RC structure was performed by comparing numerical and experimental results in modal and linear time history analyses. Using the calibrated model, nonlinear earthquake analysis and seismic fragility analysis were performed to estimate the behavior and vulnerability of the RC structure with various ground motions.

Evaluation of Post-earthquake Seismic Capacity of Reinforced Concrete Buildings suffering from earthquakes (지진피해를 받은 철근콘크리트 건물의 잔존내진성능평가)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.105-108
    • /
    • 2005
  • In damage investigation of building structures suffering from earthquake, estimation of residual seismic capacity is essential in order to access the safety of the building against aftershocks and to judge the necessity of repair and restoration. It has been proposed that an evaluation method for post-earthquake seismic capacity of reinforced concrete buildings based. on the residual energy dissipation capacity (the residual seismic capacity ratio )in lateral force-displacement curve of structural members. The proposed method was adopted in the Japanese 'Damage Level Classification Standard' revised in 200l. To evaluate the residual seismic capacity of RC column, experimental tests with positive and negative cyclic loading was carried out using RC building column specimen. Parameters used by the experiment are deformability and member proportion. From the test results, it is appropriated that the residual seismic capacity of RC buildings damaged by earthquakes is evaluated using the method in the Guideline.

  • PDF

Reasonable Demolition Method Combination of RC Structures (RC구조물의 해체공법 조합방안)

  • Kim, Se-Bum;Yang, Jin-Kook;Lee, Sang-Beom
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.177-178
    • /
    • 2016
  • The main structure of the building has been used reinforced concrete construction method in Korea. In recent years, it is necessary to demolition of buildings into urban redevelopment. But yet the demolition method is not being developed perfect. It is necessary to develop future deconstruction for safety and environment method. In this study, we surveyed the demolition method has been used in domestic construction. How the combination of these demolition method should be needed. Demolition method combinations were classified as low-rise, high-rise, middle. It suggested method to combine the demolition process of reinforced concrete structure with seven.

  • PDF

The effect of finite element modeling assumptions on collapse capacity of an RC frame building

  • Ghaemian, Saeed;Muderrisoglu, Ziya;Yazgan, Ufuk
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.555-565
    • /
    • 2020
  • The main objective of seismic codes is to prevent structural collapse and ensure life safety. Collapse probability of a structure is usually assessed by making a series of analytical model assumptions. This paper investigates the effect of finite element modeling (FEM) assumptions on the estimated collapse capacity of a reinforced concrete (RC) frame building and points out the modeling limitations. Widely used element formulations and hysteresis models are considered in the analysis. A full-scale, three-story RC frame building was utilized as the experimental model. Alternative finite element models are established by adopting a range of different modeling strategies. Using each model, the collapse capacity of the structure is evaluated via Incremental Dynamic Analysis (IDA). Results indicate that the analytically estimated collapse capacities are significantly sensitive to the utilized modeling approaches. Furthermore, results also show that models that represent stiffness degradation lead to a better correlation between the actual and analytical responses. Results of this study are expected to be useful for in developing proper models for assessing the collapse probability of RC frame structures.

A Study on the Structural Fire Resistance Performance Design of RC Structural according to the Explosive Spalling - The Investigate Study on the PBD for Fire Resistance - (폭렬현상을 고려한 RC구조물의 PBD기반 구조내화설계 기술개발에 관한 연구(II) - PBD기반 구축을 위한 조사연구 -)

  • Lee, Jae-Young;Kim, Se-Jong;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.202-209
    • /
    • 2008
  • Performance based fire engineering design is being adopted around the world as a rationed means of providing efficient and effective fire safety in Building. This development is being supported by the adoption of performance based codes which specify the objective and minimum performance requirements for fire safety traditional design for fire safety which is still practiced in many countries, relies on "prescriptive" codes which specify how a building is to be built, which no statement of objective and little or no opportunity to offer more rational alterative design. It is the aim of this study to investigate and analyze the research direction of structural fire resistance design of RC structures for recommendation of PBD in Korea.