DOI QR코드

DOI QR Code

Seismic Performance Evaluation of Unreinforced Masonry Walls with Additional Boundary RC Frames

RC 경계골조를 설치한 신축 비보강 조적벽체의 내진성능 평가

  • 유영찬 (한국건설기술연구원 건축안전연구센터) ;
  • 김민선 (한국건설기술연구원 건축안전연구센터) ;
  • 이현지 (한국건설기술연구원 건축안전연구센터)
  • Received : 2018.08.08
  • Accepted : 2018.11.15
  • Published : 2018.11.30

Abstract

The purpose of this study is to examine the effects of boundary RC frame(composed of one tie-beam and two tie-columns) on seismic performance of unreinforced masonry walls to suggest alternative way for seismic design of unreinforced masonry wall structures. Two test specimens are prepared, one is a typical unreinforced masonry wall and another is alternative unreinforced masonry wall with additional boundary RC frame. The structural experiments were carried out to evaluate the difference of seismic resistance performance between two test specimens with or without the boundary RC frames. From the test results, it was found that the failure mode of unreinforced masonry wall fundamentally changed from 'brittle' to 'ductile' by the installing of boundary RC frames. And, the maximum load and energy dissipation capacity of the test specimen with boundary RC frame was increased about 1.6~1.7 and 2~3 times respectively compared with a typical unreinforced masonry wall specimen.

Keywords

References

  1. ASTM (2002). Standard test method for diagonal tension(shear) in masonry assemblages, ASTM, E519-02
  2. ASTM (2004). Standard test method for compressive strength of masonry prisms, ASTM, 2014, C1314-03b, West Conshohocken, PA.
  3. BSI (2002). Methods of test for masonry, Part 3: Determination of initial shear strength. BSI, London, EN 1052-3.
  4. FEMA 306, Evaluation of earthquake damaged concrete and masonry wall buildings, Federal Emergency Management Agency, Washington, D.C., 1999
  5. Korea Standards Association (2010). Standard test method for compressive strength of concrete. KS F 2405.
  6. Korea Standards Association (2016). Steel bars for concrete reinforcement. KS D 3504
  7. Korea Standards Association (2007). The pieces for tension test for metallic materials. KS B 0801.
  8. Korea Standards Association (2003). Method of tensile test for metallic materials. KS B 0802
  9. Korea Industrial Standard (2012). Tensile testing machines. KS B 5521
  10. Luce, R. D. (1959). Individual Choice Behavior a Theoretical Analysis. John Wiley and sons.
  11. Lee, J. H. (2005). Seismic capacity and seismic retrofitting of low rise buildings- unreinforced masonry, brick-infilled RC frame, and steel slit damper retrofitted RC Frame, Ph.D Thesis, KwangWon Univ., Seoul
  12. Lee, J. H., Kim, H. W., Kim, J. S., & Park, B. C. (2011). Evaluation of seismic vulnerable part in URM buildings, Proceedings of the Korea Concrete Institute, v.23 n.1, 113-114
  13. Ministry of Education (2018). Seismic performance evaluation of school facilities and retrofit manual
  14. National Disaster Management Research Institute (2001). A Report for India Kachi Earthquake Damage, NDMRI Press, 30-40.
  15. Yang, K. H., Joo, D. B., Sim, J. I., & Kang, J. H. (2012). In-plane Seismic Performance of Unreinforced Masonry walls strengthened with unbonded prestressed wire rope units. Engineering structures, 45, 449-459. https://doi.org/10.1016/j.engstruct.2012.06.017
  16. You, Y. C., Choi, K. S., & Shin, J. U. (2014). A 1st Year-Report on Evaluation of Structural Performance of Small-Size Masonry/Steel Building, Goyang, Korea Institute of Civil Engineering and Building Technology Press, 216.