• 제목/요약/키워드: RASS

검색결과 18건 처리시간 0.021초

Design of Closed Seawater Recirculating Aquaculture System for Korean Rockfish Sebastes schlegeli Culture

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • 제26권1호
    • /
    • pp.102-111
    • /
    • 2004
  • Recirculating aquaculture system (RAS) consists of different treatment compartments that maintain water quality within the ranges commonly recommended for fish cultures. However, common RASs still exert considerable environmental impact since concentrations of organic matter and nutrients in their effluents are high. Compared with the traditional RAS, the model RAS developed here use a sedimentation basin for digestion purposes and then use the released volatile organic matter to stimulate a denitrification process. Different treatment compartments for solids, total ammonia nitrogen, and nitrate removal have been reviewed. This paper provides the basic information on designing different treatment compartments as well as the engineering criteria in closed seawater RAS, consisting of circular tanks for fish cultures; dual drain systems, sedimentation basins and foam fractionators for removal of solids; nitrification biofilters for TAN removal; denitrification biofilters for nitrate removal; and aerators for aeration. The main purpose is to outline a common procedure in designing of closed RAS for marine fish culture with an emphasis on easy management and low expense, as well as reduction of the environmental impact.

해삼사료원료로서 육상순환여과양식장 고형오물의 이화학적 특징과 해삼(Apostichopus japonicus)의 소화흡수율 (Fecal Solid Feed from the Recirculating Aquaculture System of the Renewable Sea Cucumber Apostichopus japonicus)

  • 정우철;;최종국;;최병대;강석중
    • 한국수산과학회지
    • /
    • 제49권3호
    • /
    • pp.330-336
    • /
    • 2016
  • Pollution caused by fecal solids released from recirculating aquaculture systems (RAS) is a growing global concern requiring immediate attention. Thus, this study investigated the physicochemical characteristics of fecal solid feed from RASs used for eel and rainbow trout farming. The concentrations of proteins, lipids, crude ash, and moisture in eel fecal solids were 10.9%, 1.2%, 85.8%, and 72.2%, respectively, while those in rainbow trout fecal solid feed were 20.5%, 3.2%, 70.9%, and 87.0%, respectively. The control group was fed a mixture of sea cucumber and dried sea mud. The protein digestibilities of eel and rainbow trout fecal solids were 25.43% and 23.96%, respectively, while the respective lipid digestibilities were 35.62% and 36.80%, respectively.

Change of transmission characteristics of FSSs in hybrid composites due to residual stresses

  • Hwang, In-Han;Chun, Heoung-Jae;Hong, Ik-Pyo;Park, Yong-Bae;Kim, Yoon-Jae
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1501-1510
    • /
    • 2015
  • The frequency selective surface (FSS) embedded hybrid composite materials have been developed to provide excellent mechanical and specific electromagnetic properties. Radar absorbing structures (RASs) are an example material that provides both radar absorbing properties and structural characteristics. The absorbing efficiency of an RAS can be improved using selected materials having special absorptive properties and structural characteristics and can be in the form of multi-layers or have a certain stacking sequence. However, residual stresses occur in FSS embedded composite structures after co-curing due to a mismatch between the coefficients of thermal expansion of the FSS and the composite material. In this study, to develop an RAS, the thermal residual stresses of FSS embedded composite structures were analyzed using finite element analysis, considering the effect of stacking sequence of composite laminates with square loop (SL) and double square loop (DSL) FSS patterns. The FSS radar absorbing efficiency was measured in the K-band frequency range of 21.6 GHz. Residual stress leads to a change in the deformation of the FSS pattern. Using these results, the effect of transmission characteristics with respect to the deformation on FSS pattern was analyzed using an FSS Simulator.

대기안정도 분류방법의 평가 및 실용화에 관한 연구 (Evaluation of Atmospheric Stability Classification Methods for Practical Use)

  • 김정수;최덕일;최기덕;박일수
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.369-376
    • /
    • 1996
  • Major atmospheric stability classification methods were evaluated with meteorological data obtained by scoustic sounding profiler (SODAR/RASS) in Seoul. The Psequill classificatio method, the method most widely used because of its good agreement in respect of synoptic scope under the steady state, fails to describe the time lag, the response time on stability by heating or cooling caused by daily insolation or noctrunal surface radiation. Horizontal and vertical standard deviation of wind fluctuation $(\sigma_A and \sigma_E)$ method tend to classify night-time stable condition (E, F class) into unstable condition (A, B class). The classification matrix tables for Vogt's vertical temperature difference and wind speed using method ($\Delta$T $\cdot$ U) and bulk Richardson number (Rb) were amended for practical use over Seoul. The modified tables for $\Delta$T $\cdot$ U and Rb method were made by using comprehensive frequency distribution from Pasquill's method and other existing results, and the correlation coefficient(r) was equal to 0.829. It was confirmed that atmospheric stability could be changed with monitoring site characteristics, height and vertical difference between sensors of monitoring station, and classification method itself.

  • PDF

Management of the energy harvesting for MEMS/NEMS via newmark current method

  • Shang, Kun;Shan, Huafeng;Alkhalaf, Salem;Marzouki, Riadh;Khadimallah, Mohamed Amine
    • Advances in nano research
    • /
    • 제12권6호
    • /
    • pp.567-581
    • /
    • 2022
  • The free and forced vibration in addition to electric energy harvesting of a piezoelectric disk resting on two-parameter foundation modeled by modified couple stress as well as Kirchhoff plate theory is probed. The governing equations and boundary conditions are obtained using Hamilton's principle. Then, the free and forced vibration are solved using numerical solutions, generalized differential quadrature method (GDQM) and Newmark-beta method. The forced vibration is resulted from a base excitation load. Also, the possible voltage which can be harvested from this system is obtained using generalized integral quadrature method. The validity of the formulation and solution procedure is confirmed using a compassion study. The impact of parameters such as length effect, inner to outer radius ratio, and foundations parameters on the free and forced vibration as well as energy harvesting is investigated in detail. This paper can be a basis for future studies in the area of piezoelectric harvesters in small scales.

Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters

  • Hussein, Mostafa Omran;Hussein, Lamis Ahmed
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권3호
    • /
    • pp.150-161
    • /
    • 2022
  • PURPOSE. The purpose of the study was to assess the influence of build orientations and density of support structures on the trueness of the 3D printed removable partial denture (RPD) frameworks. MATERIALS AND METHODS. A maxillary Kennedy class III and mandibular class I casts were 3D scanned and used to design and produce two 3D virtual models of RPD frameworks. Using digital light processing (DLP) 3D printing, 47 RPD frameworks were fabricated at 3 different build orientations (100, 135 and 150-degree angles) and 2 support structure densities. All frameworks were scanned and 3D compared to the original virtual RPD models by metrology software to check 3D deviations quantitatively and qualitatively. The accuracy data were statistically analyzed using one-way ANOVA for build orientation comparison and independent sample t-test for structure density comparison at (α = .05). Points study analysis targeting RPD components and representative color maps were also studied. RESULTS. The build orientation of 135-degree angle of the maxillary frameworks showed the lowest deviation at the clasp arms of tooth 26 of the 135-degree angle group. The mandibular frameworks with 150-degree angle build orientation showed the least deviation at the rest on tooth 44 and the arm of the I-bar clasp of tooth 45. No significant difference was seen between different support structure densities. CONCLUSION. Build orientation had an influence on the accuracy of the frameworks, especially at a 135-degree angle of maxillary design and 150-degree of mandibular design. The difference in the support's density structure revealed no considerable effect on the accuracy.

잔디류식물에 있어 생장억제제시용효과에 관한 연구 (Growth Regulation of Korean Lawngrass and Manilagrass with Several Growth Retardants)

  • 심재성
    • 아시안잔디학회지
    • /
    • 제3권1호
    • /
    • pp.39-52
    • /
    • 1989
  • Native Kerean lawngrass (Zeysia japonica steud.) and Manilagrass ( Zeysia matrella Merr.) are frequently used as sport turf and lawn in Kerea and ether Asian countries because of its excellent summer qualities and superior winter-hardiness compared to ether warm-season turfgrass . The objective of this study was to investigate the effect of the plant growth retardants ( PGR ) en the inhibition (d the growth of the two Kerean native turfgrasses. Kerean lawngrass and Manilagrass were treated with [2 RS , 3 RS] -1- [4- chlorophenyl ] -4, 4-dimethyl -2- [1 H -1, 2, 4- tiazol -1- y] pentan -3- ol ( PP -333) at 93 and 930 gha -j ; 5-[4- chlorphenyl ]-3, 4, 5, 9, 10- peiitaaza - tetracyclo [5, 4, 1, 0 2 6 . o ~'~I -3, 9- diene ( BAS -106) at 16 and 160 gha ; [ E I-] - cyclohexyl -4, 4- dimethyl -2- [1, 2, 4- triazol -1- yl ]-1-pentene - 3- ol ( NTN -821) at 56 and 560 gha ', and 4- chloro -2- [$\alpha$- hydrozybenzy I isonicotin anilide ( CGR -811) at 92 gha in pot study . All PGR treatments were effective in reducing the plant height, with the exception of BAS -106 at 16 gha for Korean lawngrass ; however , all increased quality to some degree , with the exception of PP -333 at 93 gha . The low PGR rates significantly increased Korean lawngrass height during late jtily aitd mid-August . On the other hand , BAS -106 significantly increased Manilagrass height {rom 24 Septeml)er onwards . All PGR treatments haol higher turfgrass quality than untreatments , and also the high rates of PGIt treatments were more effective in increasing quality than the low rates observed on 8 October . Meanwhile , Manilagrass quality was increased to some extent than Korean lawegrass . PP - 333 was significantly effective in reducing clipping yield and the same results were found with the application of NTN -821 at 560 gha -l for both Korean lawngrass and Manilagrass , BAS -106 at 160 gha for Korean lawegrass , and CGR -811 at 92 gha for Manilagrass . The high PGR rates had higher turfgrass shoot weight observed on 8 October than the low rates , and there were little increases obtained with the low rates of PP -333 for Korean lawngrass and BAS - 1 06 for Manilagrass . Effeets on stolon growth varied between growth retardants , and between retardant treatments ; the high rates of PGR as well as the low rate of NTN -821 elongated stolon of Korean lawngrass and manoilagrass . However , PP -333 at 93 gha and BAS -106 at 16 gha - shortened stolons of Korean lawugrass , resulting in inhibition or little difference of stolon dry weight . NTN -821 at 560 gha and CGR -811 had no positive effect on the stolon length of Manilagrass . 101) -333 and the low rate of BAS -106 and NTN -821 decreased root weight of Korean lawng - rass All PGR rates had negative effect on the root weight of Manilagrass with the exception of BAS -106 CR -811 and the high rate of NTN -821 which made no difference in root weight between retarolant treatments and the control .

  • PDF

A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve

  • Bu Kwang Oh;Dong Wuk Son;Jun Seok Lee;Su Hun Lee;Young Ha Kim;Soon Ki Sung;Sang Weon Lee;Geun Sung Song;Seong Yi
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권1호
    • /
    • pp.60-72
    • /
    • 2024
  • Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.