• Title/Summary/Keyword: RAE

Search Result 8,922, Processing Time 0.029 seconds

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Seasonal Variations of Water Quality in the Lower Part of the Nagdong River (낙동강 하류수질의 계절적 변화)

  • KIM Yong-Gwan;SHIM Hye-Kung;CHO Hak-Rae;YOU Sun-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.6
    • /
    • pp.511-522
    • /
    • 1984
  • The Nagdong is one of the biggest rivers in Korea, which is very important water source not only for tap water of Pusan city but also for the industrial water. Therefore, authors tried to check the water quality year by year. In this experiment one hundred and twenty water samples collected from August 1983 to July 1984 were analyzed bacteriologically and physiologically. Fifteen sampling stations were established between near Samrangjin and estuary of the river. To evaluate the water quality, temperature, pH, chloride ion, salinity, chemical oxygen demand (COD), electrical conductivity, nutrients, total coliform, fecal coliform, fecal streptococcus, viable cell count and bacterial flora were observed. The variation of water temperature was ranged $-1.5{\sim}29.0^{\circ}C$ (Mean value $13.9{\sim}16.5^{\circ}C$), it in spring was higher as $10{\sim}15^{\circ}C$ about $10^{\circ}C$ than in winter and it in autumm was very stabilized as about $20^{\circ}C$ at each station. The pH variation of the samples was ranged $6.68{\sim}9.15$. The range of concentration of chloride ion and salinity varied $7.4{\sim}l,020.5$ mg/l and $1.05{\sim}33.0\%0$, respectively. Especially, salinity of the 3rd water war was the higher than others as $25.76{\sim}31.58\%0$. COD was ranged $1.45{\sim}14.94$ mg/l and the lower part of the Nagdong River was heavily contaminated by domesitc sewage and waste water from the adjacent factor area. The range of electrical conductivity was $1.360{\times}10^2{\sim}5.650{\times}10^4{\mu}{\mho}/cm$ and that was by far higher the estuary than the upper. Concentration of nutrients were $0.008{\sim}0.040$ mg/l (Mean value $0.019{\sim}0.068$ mg/l) for $NO_2-N,\;0.038{\sim}5.253$ mg/l ($0.351{\sim}2.347$ mg/l) for $NO_3-N,\;0.100{\sim}2.685$ mg/l($0.117{\sim}1.380$ mg/l) for $NH_4-N,\;0.003{\sim}0.084$ mg/l($0.014{\sim}0.065$ mg/l) for $PO_4-P$ and $0.154{\sim}6.123$ mg/l ($1.165{\sim}3.972$ mg/l) for $SiO_2-Si$, respectively. Usually nutrients contents of the water in the upper part(included station 1 to 5) were higher than those of the estuarine area. The bacterial density of the samples ranged 7.3 to 460,000/100 ml for total coliforms, 3.6 to 460,000/100 ml for fecal coliform, $0{\sim}46,000/100ml$ for fecal streptococcus and $<30{\sim}1.2{\times}10^5/ml$ for viable cell count. Composition of coliform was $28\%$ Escherichia coli group, $18\%$ Citrobacter freundii group, $31\%$ Enterobacter aerogenes group and $22\%$ others. Predominant species among the 659 strains isolated from the samples were Pseudomonas spp. ($42\%$), Flavobacterium spp. ($20\%$) and Moraxella spp. ($12\%$).

  • PDF