• 제목/요약/키워드: R170

검색결과 530건 처리시간 0.028초

산업용 자동 재봉기 제어장치 개발에 관한 연구 (A study on the development of automatic sewing machine)

  • 김종찬;라승호;이응혁;허경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.281-285
    • /
    • 1990
  • Our N.C. sewing machine is a device that acts sewing automatically in reference to N.C. data made by data input device. Our N.C. sewing mechine is composed of induction motor that has electric clutch and brake, step motor that drives x-y table. Sewing area of our machine is 170 mm * 100 mm, maximum sewing speed is about 2000 spm, maximum stitch length 6.2 mm. In actual sewing, synchronization between motion of needle up-down and motion of x-y table is a critical factor. In this paper, technology about synchronization will be profoundly discussed.

  • PDF

강굴, Crassostrea rivularis 의 난발생 및 유생사육에 미치는 수온과 염분의 영향 (Influence of Water Temperature and Salinity on Egg Development and Larvae Rearing of Oyster, Crassostrea rivularis)

  • 유성규;강경호
    • 한국패류학회지
    • /
    • 제11권2호
    • /
    • pp.165-170
    • /
    • 1995
  • 강굴의 효율적인 종묘생산을 위한 생물학적 기초자료를 얻고자 난발생 및 유생사육에 미치는 환경요인으로서 수온과 염분의 영향에 대하여 실험한 결과는 다음과 같다. 1. 유생사육의 각 단계에 이르기까지의 수온(T, $^{\circ}C$)에 따른 발생속도(h, 시간)는 수온이 높을수록 빨랐으며 그 관계식은 다음과 같다. D형 유생: 1/h= 0.0017T-0.0033(r=0.9882)초기 각정기 유생:1/h= 0.0003T-0.0044(r=0.9496)후기 각정기 유생:1/h= 0.0002T-0.0028(r=0.9918)성숙유생:1/h= 0.0001T-0.0011(r=0.9997)2. 유생사육시 수온과 난발생속도와의 관계에서 추정된 난발생의 생물학적 영도는 평균 10.4$^{\circ}C$였다.3. 강굴의 난발생이 가능한 하한 및 상한 염분농도는 10$\textperthousand$와 37$\textperthousand$였다.

  • PDF

A Novel Lens Design for Slim, Large Size, Direct Type LED Backlight Module

  • Li, Tzung-Yang;Lin, Tzu-Pin;Chou, Ming-Der;Tsou, Chien-Lung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.72-75
    • /
    • 2009
  • In this paper, we have designed a novel lens for LED's package that can expend the radiation angle of LED from $120^{\circ}$ to $170^{\circ}$ successfully. At the same brightness and uniformity condition of 37" LED BLU system, using novel lens LED package can be reduced amounts of LED 40% or thickness of BLU 30% respectively. Besides, the power consumption of BLU also can be reduced 25%.

  • PDF

동기발전기의 자동전압조정장치 제어기 설계 (AVR controller design of synchronous generator)

  • 이종무;김문환;이주훈;박용희;임익헌;구기민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.167-170
    • /
    • 1993
  • This paper deals with AVR(Automatic Voltage Regulator) control1or design of synchronous generator adapting AC indirect excitation system. The simulation results are presented in frequency and tine domain for two plants(A and B). Try and error method for compensator design is used.

  • PDF

디지털 포렌식 관점에서 CD-R 미디어의 해쉬 값 생성에 관한 연구 (Study on Hashing of CD-R Media from the Viewpoint of Digital Forensics)

  • 박정흠;김권엽;이상진;임종인
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2008년도 동계학술대회
    • /
    • pp.167-170
    • /
    • 2008
  • 해쉬 알고리즘은 디지털 포렌식 수사에서 디지털 증거의 무결성을 증명하기 위해 널리 사용되고 있다. 디지털 증거의 무결성은 동일한 데이터에서만 같은 해쉬 값이 계산된다는 성질에 의하여 증명된다. 일반적으로 동일한 데이터에 대한 해쉬 값은 서로 다른 포렌식 툴을 이용해서 계산을 해도 항상 같은 값이 출력될 것이라고 인식하고 있다. 하지만, CD-R 미디어의 경우에는 해쉬를 계산하는 포렌식 툴에 따라 값이 다르다는 특성이 있다. 이것은 해쉬 값이 CD 제작 도구에서 CD-R 미디어에 데이터를 기록하는 방식과 각 포렌식 툴 별로 CD-R 미디어를 인식하는 방식에 의해 영향을 받기 때문이다. 이러한 특성은 CD-R 미디어의 무결성 증명 시에 문제가 될 여지가 있기 때문에 디지털 포렌식 수사 절차에서 반드시 고려되어야 한다. 본 논문에서는 CD-R 미디어의 해쉬 값에 영향을 주는 요소에 대해 기술하고, 실험용 CD-R 미디어를 제작하여 대표적인 디지털 포렌식 도구들을 이용해서 확인한다. 이를 통해, 디지털 포렌식 수사 절차에서 CD-R 미디어에 대한 해쉬 값을 계산할 때 고려해야 할 사항을 제안한다.

  • PDF

Development of High Efficiency PDP Driven by RF Pulses

  • Choi, J.P.;Jeon, W.G.;Kang, J.;Lim, G.S.;Kim, O.D.;Kim, H.Y.;Song, J.W.;Yoo, E.H.;Park, M.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.169-170
    • /
    • 2000
  • The conventional AC PDP has a relatively low efficiency which is close to 1.5 lm/W. If the AC sustain period is replaced by the RF sustain period, due to oscillating and low electric field, almost 60% of the supplied energy is spent by Xe excitation [1]. The efficiency of RF PDP can be $4{\sim}5$ times higher than that of AC PDP. In this paper, we will present the RF PDP that is a new type of PDP. A new display method in PDP using RF pulses is suggested and applied on a 4-inch-diagonal Panel (hereinafter 4" panel). Even though there were many researches in RF discharge, there was not enough research for display application. Now we propose the RF PDP that is a new display field and we will expect to do more research in this field.

  • PDF

궤도 및 교량 안전성을 고려한 열차 증속가능 속도대역 평가 (Evaluation on Allowable Vehicle Speed Based on Safety of Track and Railway Bridge)

  • 방은영
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.145-151
    • /
    • 2018
  • In this study, the track-bridge interaction analysis was performed using an analytical model considering the track structure, thereby taking into account the linear conditions (R=650 m, cant variation $160{\pm}60mm$) and the dynamic characteristics of the bridge. As a result of the study, the allowable speed on the example bridge considered was calculated at 200 km/h based on vertical deflection, vertical acceleration, and irregularity in longitudinal level, but was also evaluated at 170km/h based on the coefficient of derailment, wheel load reduction, and lateral displacement of the rail head. It is considered desirable to set the speed 170km/h to the speed limit in order to secure the safety of both the bridge and the track. It is judged that there will be no problems with ensuring rail protection and train stability in the speed band.

Reperfusion Hyperemia Demonstrated on Perfusion MRI: It′s Relationship with Programmed Cell Death

  • 이승구;김동익;김상흠;김시연;인연권
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.170-170
    • /
    • 2001
  • Purpose: To evaluate the relationship between reperfusion hyperemia in reversible cerebral ischem and the degree of programmed cell death. Method: We produced the animal models of reversible cerebral ischemia in 10 cats by mean of middle cerebral artery (MCA) occlusion with transorbital approach. MCA was occluded b microvascular clamp for an hour. MR imaging was performed at 0, 1, 2 days after ischemi and reperfusion. Perfusion (PWI) [Contrast enhanced GRE EPI, TR/TE= 1500/40, 40 Phases, 128 matrix, 12 cm FOV] and diffusion (DWI) (SE EPI, b=0, 500, 1000) weighted images were obtained using Philips Intera 1.57 system. rCBV and ADC maps were calculated wi IDL based postprocessing program. Tissue slices were obtained after the last MR imagin TUNEL, Calbin and Acid-Fuscin staining were done for corresponding slices as MR imagin We investigated the differences of degree of apoptosis in the area of reperfusion hyperemia.

  • PDF

Surface Alloy Formation of Nb on Cu(100)

  • 이준희;윤홍식;양경득;여인환
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.170-170
    • /
    • 1999
  • We studied Nb growth mode on Cu(100) surface by scanning tunneling microscopy (STM) at room temperature. Nb/Cu is immiscible at room temperature and thus is an ideal system for studying surface alloy formation. Initially deposited Nb atoms are incorporated subsurface on Cu(100). After annealing, they are preferentially found at step edges and appear as bright dots surrounded by dark rings. Ordering emerges from step edges as annealed. Ordered ({{{{ SQRT { 5} }$\times${{{{ SQRT { 5} }}}})R 26.6$^{\circ}$phase Nb structure is formed at $\theta$<0.2ML after annealing to 50$0^{\circ}C$. At higher coverage, $\theta$>0.25, annealing leads to p(2$\times$2) phase. due to large mismatch in lattice parameters, the domain is limited to a few tens of nm2. Growth kinetics of the system will be discussed.

  • PDF

저온용 대체냉매의 성능 특성 연구 (Performance Characteristics Study on an Alternative Refrigerant in Low Temperature Applications)

  • 신정섭;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.462-469
    • /
    • 2016
  • This paper presents the results of thermodynamic cycle analysis and performance tests of alternative mixtures in low temperature applications. Two near-azeotropic binary mixtures R-152a/R-1270 (35:65 by wt.%) and R-290/E170 (35:65 by wt.%) are considered in this study. They have zero ODP (Ozone Depletion Potential) and much lower GWP (Global Warming Potential) than R-404A which is an alternative of R-502. Refrigeration cycle characteristics such as cooling capacity, coefficient of performance, suction and discharge pressures and temperatures are compared to those for the baseline refrigerants (R-502 and R-404A) cycles. The performance tests are conducted at the evaporation and condensation temperatures of $5^{\circ}C$ and $45^{\circ}C$, subcooling and superheating temperatures of $5^{\circ}C$, respectively. Performance comparisons between baseline and alternative refrigerants are conducted on the same cooling capacity. The system performance of newly proposed refrigerant mixtures show promising results.