This paper presents the results of thermodynamic cycle analysis and performance tests of alternative mixtures in low temperature applications. Two near-azeotropic binary mixtures R-152a/R-1270 (35:65 by wt.%) and R-290/E170 (35:65 by wt.%) are considered in this study. They have zero ODP (Ozone Depletion Potential) and much lower GWP (Global Warming Potential) than R-404A which is an alternative of R-502. Refrigeration cycle characteristics such as cooling capacity, coefficient of performance, suction and discharge pressures and temperatures are compared to those for the baseline refrigerants (R-502 and R-404A) cycles. The performance tests are conducted at the evaporation and condensation temperatures of $5^{\circ}C$ and $45^{\circ}C$, subcooling and superheating temperatures of $5^{\circ}C$, respectively. Performance comparisons between baseline and alternative refrigerants are conducted on the same cooling capacity. The system performance of newly proposed refrigerant mixtures show promising results.

Keywords

References

  1. M.-H. Kim, Global warming and alternative refrigerants technology, Magazine of SAREK, Vol. 36, No. 7, pp. 7-19, 2007.
  2. A. Stegou-Sagia, N. Paignigiannis, Evaluation of mixtures efficiency in refrigerating systems, Energy Conversion and Management, Vol. 46, pp. 2787-2802, 2005. https://doi.org/10.1016/j.enconman.2005.01.007
  3. R. Camporese, G. Bigolaro, S. Bobbo, Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502, International Journal of Refrigeration, Vol. 20, No. 1, pp. 22-31, 1997. https://doi.org/10.1016/S0140-7007(96)00062-X
  4. P.A. Domanski, D.A. Didion, Theoretical evaluation of R22 and R502 alternatives, NIST Report Prepared for ARTI. MCLR Project 650-50900, 1993.
  5. Y. Xuan, G. Chen, Experimental study on HFC-161 mixture as an alternative refrigerant to R502, International Journal of Refrigeration, Vol. 28, No. 3, pp. 436-441, 2005. https://doi.org/10.1016/j.ijrefrig.2004.04.003
  6. European Parliament, "Regulation (EU) No 517/2014 of the European Parliament and of the Council on flourinated greenhouse gases," Off. J. Eur. Union, No. L150, pp. 195-230, 2014.
  7. M. Huber, J. Gallagher, M. McLinden, G. Morrison, REFPROP 9.1, NIST Thermo- dynamic Properties of Refrigerants and Refrigerant Mixtures Database, 2009.
  8. J.-S. Shin, M.-H. Kim, Performance evaluation of near-azeotropic R502 alternative refrigerants, The 7 th IIR Gustav Lorentzen Conference on Natural Working Fluids, Trondheim, Norway, 2006.
  9. ASHRAE, Fundamentals, ASHRAE Handbook, Ch. 19-20, 2013.
  10. S. Devotta, A.B. Waghmare, N.N. Sawant, B.M. Domkundwar, Alternatives to HCFC-22 for air conditioners, Applied Thermal Engineering, Vol. 21, pp. 703-715, 2001. https://doi.org/10.1016/S1359-4311(00)00079-X