• Title/Summary/Keyword: R-test

Search Result 10,557, Processing Time 0.062 seconds

Evaluation of Vi-Passive Hemagglutination, SD$^{(R)}$ Kit, and Widal Test for Serological Diagnosis of Typhoid Fever (장티푸스의 혈청학적 진단을 위한 Vi-수동혈구응집법, SD$^{(R)}$ Kit 및 Widal 시험에 대한 효용성 평가)

  • Kim, Sung-Hun;Kim, Shuk-Ho;Lee, Deog-Yong;Lee, Esther;Park, Mi-Sun;Lee, Bok-Kwon
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.219-222
    • /
    • 2010
  • In this study, we evaluated Vi-passive hemagglutination (Vi-PHA), SD Salmonella Typhi IgG/IgM ($SD^{(R)}$ kit) and Widal test for the rapid laboratory diagnosis of typhoid fever patients. A total of 36 serum samples from febrile patients in Korea from 2005 to 2006 were used. Among 36 patients, 27 were fever patients without typhoid, 9 were typhoid fever. Vi-PHA showed 8 positive results out of 9 typhoid fever patients (sensitivity 88.9%) and 1 positive and 26 negative results out of 27 febrile patients without typhoid (specificity 96.3%). The sensitivity and the specificity of $SD^{(R)}$ kit were 100% and 92.6%, respectively. However, the sensitivity and the specificity of Widal O & H tests were 88.9%, 100%, and 77.8%, 70.4%, respectively. Consequently, Widal H and $SD^{(R)}$ kit showed higher sensitivity and Vi-PHA showed higher specificity. To efficient diagnosis, Vi-PHA may be sufficient diagnosis method in acute cases and $SD^{(R)}$ kit and Widal test may be sufficient in sporadic area and high risk group.

Investigation About Quality Control of General X-ray System

  • Kang, Byung-Sam;Son, Jin-Hyun;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.157-164
    • /
    • 2011
  • This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

  • PDF

Comparative study in marginal adaptation of zirconia cores fabricated with 3 different CAD/CAM systems (3종의 CAD/CAM 시스템에서 지르코니아 코어의 변연 적합도에 관한 비교 연구)

  • Kwon, Yong-Joong;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.12-21
    • /
    • 2008
  • Statement of problem: There have been many studies about marginal adaptation of Zirconia core fabricated with various CAD/CAM systems. But, the comparative study has not been conducted much. Purpose: This study was to compare marginal adaptations of zirconia cores fabricated with 3 different CAD/CAM systems. Material and methods: The in vitro marginal adaptations of zirconia cores fabricated with 3 different CAD/CAM systems($Adens^{(R)}$ system, $Lava^{(R)}$ system, and $Cerasys^{(R)}$ system) were evaluated and compared. In this study 30 zirconia cores were fabricated(10 zirconia cores per each system). The measurements of the marginal adaptatioin were carried out using microscope $L-150A^{(R)}$(Nikon, Japan). Measurements were recorded at 50 points. The measurements were analyzed using Kruskal-Wallis test and Wilcoxon rank sum test. Results: Within the limits of this study, the results were as follows. 1. Mean marginal gap values obtained were $284.5{\pm}152.9{\mu}m$ in Adens system, $99.0{\pm}73.0{\mu}m$ in Lava system, and $153.5{\pm}85.7{\mu}m$ in Cerasys system. 2. Zirconia core made by Lava system showed the smallest marginal gap(P<0.05). Conclusion: In the limitation of this study, we concluded that $Lava^{(R)}$ System was superior than other systems($Adens^{(R)}$ system and $Cerasys^{(R)}$ system) in the marginal adaptation.

Condensing Heat Transfer Charactristics of R-22 Alternative Refrigerants on Water Sources Heat Pump (수열원 펌프에서의 R-22 대체냉매의 응축열전달특성에 관한 연구)

  • 김기수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.285-293
    • /
    • 1998
  • This paper presents an experimental study on condensing heat transfer characteristics of R-22 alternative refrigerants, R-290 and R-410a on water sources heat pump. The apparatus mainly consisted of vapor pump condenser used to the test section evaporator manual expansion valve and measuring device. Test section constructed a smoothed tube of 10.07 mm ID and 12.7mm OD with a total length 6,300 mm was horizontal double pipe counterflow condenser. The refrigerants R-22, R-290 and R-410a were cooled by a coolant circulated in a surrounding annulus. Experimental range of mass velocities was changed from about 100 to 300 kg/($m^2$.s) and inlet quality 1.0 The credibility of experimental apparatus was 6 percent between heating capacity and cooling capacity added to compressor shaft power. The condensing heat transfer coefficients were increased with increasing mass velocity. However in case of R-290 they were more increasing than those of R-410a and R-22 Comparing the heat transfer coefficient between the experimental data and other's data the Cavallini-Zecchin's data was revealed to more similar prediction of author's experimental results on the average heat transfer coefficients.

  • PDF

Mutagenicity Test on CJ-50001 (rG-CSF) (CJ-50001 (rG-CSF)에 대한 변이원성시험)

  • 강재구;백남진;김달현;하석훈;김제학;김현수
    • Toxicological Research
    • /
    • v.13 no.3
    • /
    • pp.297-301
    • /
    • 1997
  • In order to evaluate the mutagenic potential of CJ-50001 (recombinant human granulocytecolony stimulating factor), 3 sets of mutagenicity tests were performed. In the reverse mutation test using Salmonella typhimurium TA1535, TA1537, TA98 and TA100, CJ-50001 did not increase the number of revertant at any of the concentration tested in this study (500, 250, 125, 62.5 and 31.3 $\mu\textrm{g}$ plate). CJ-50001, at the doses of 200, 100 and 50 $\mu\textrm{g}$ /ml, did not increase the number of cells having structural or numerical chromosome aberration in cytogenetic test using Chinese Hamster Lung cells. In mouse micronucleus test, no significant increase in the occurrence of micronucleated polychromatic erythrocytes was observed in ICR male mice intraperitoneally administered with CJ-50001 at the doses of 5, 2.5 and 1.25 mg/kg. These results indicate that CJ-50001 has no mutagenic potential in these in vitro and in vivo systems.

  • PDF

Prediction of Particulate Matter Being Accumulated in a Diesel Particulate Filter (디젤 매연 필터에서 퇴적되는 입자상 물질의 퇴적량 예측)

  • Yu, Jun;Chun, Je-Rok;Hong, Hyun-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.3
    • /
    • pp.29-34
    • /
    • 2009
  • Diesel particulate filter (DPF) has been developed to optimize engine out emission, especially particulate matter (PM). One of the main important factors for developing the DPF is estimation of soot mass being accumulated inside the DPF. Evaluation of pressure drop over the DPF is a simple way to estimate the accumulated soot mass but its accuracy is known to be limited to certain vehicle operating conditions. The method to compensate drawback is adoption of integrating time history of the engine out PM and burning soot. Present study demonstrates current status of the soot estimation methods including the results from the engine test benches and vehicles.

Full Scale Load Tests on Reinforced Slope Structure (사면보강구조물에 대한 실물재하시험과 평가)

  • Kwon, Young-Ho;Park, Shin-Young;Lee, Seung-Hyun;Kang, In-Kyu;Ki, Min-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.241-255
    • /
    • 2006
  • Owing to a landslide or embankment damage be caused by a localized torrential downpour and heavy snowfall resulted from recent abnormal climate, a slope stability is very important. This study is investigate a general slope reinforcement method and applicability improvement of soil nailing method utilized prototype loading test for the facing stiffness effect confirmation. A prototype loading test supplements general slope stability study by numerical analysis or laboratory test with a resonable analysis of slope structure.

  • PDF

[ $SRV^{(R)}$ ]-Testing of the Tribosystem Piston Ring and Cylinder Liner Outside the Engine

  • Woydt Mathias;Ebrecht Johannes
    • KSTLE International Journal
    • /
    • v.6 no.2
    • /
    • pp.58-64
    • /
    • 2005
  • An OEM driven working group started in January 2004 to elaborate the philosophies, concepts and test procedures for testing piston ring and cylinder liner materials as well as engine oils outside the engine using the $SRV^{(R)}$ test equipment. The different $SRV^{(R)}$ test philosophies in use by OEMs are compiled. The working group focuses on a.) ASTM sequence VIB (Fuel economy by aging oils), b.) friction and wear in the top dead region under mixed/boundary lubrication, c.) extreme pressure load under mixed/boundary lubrication and d.) hydrodynamic friction. Tribological test result and precision data are presented.

Accelerated Life Analysis and Endurance Verification of Electro-Mechanical Actuator (항공기용 전기식 날개 구동장치의 가속 수명 분석 및 시험을 통한 내구성 검증)

  • Huh, Seok Haeng;Lee, Byung Ho;Seol, Jin Woon;Baek, Joo Hyun;Yang, Myung Seok;Kwon, Jun Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.10
    • /
    • pp.829-835
    • /
    • 2016
  • Electro-Mechanical Actuator installed on the aircraft plays a key role in an aircraft's flight control through flight control computer. Reliable prediction of the actuator is important for the aircraft. To estimate the lifetime of a product, it is necessary to test full target life. However, it is very difficult to perform it due to the long life time of actuator but short period of development time with increasing cost. Therefore, accelerated life test has been used to reduce the test time for various reasons such as reducing product's development cycle and cost. In this paper, to predict the lifetime of the actuator, we analyzed the flight profile of aircraft and adapted the method of accelerated life test in order to accelerate failure modes that might occur under user conditions. We also set up an endurance test equipment for validating the demanded lifetime of an actuator and performed accelerated life test.

Application of Fault Current Limiter in 22.9kV KEPCO power distribution line (22.9kV 지중선로용 한류기 한전 실계통 시범적용)

  • Kim, Min Jee;Park, Kyungwon;Ahn, Kil-Young;Kim, Young-keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF