• 제목/요약/키워드: R-ratio

검색결과 6,127건 처리시간 0.033초

측정 ANOVA의 분산성분에 의한 게이지 R&R 추정 (Estimation of Gauge R&R by Variance Components of Measurement ANOVA)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제12권1호
    • /
    • pp.199-205
    • /
    • 2010
  • The research proposes the three-factor random measurement models for estimating the precision about operator, part, tool, and various measurement environments. The combined model with crossed and nested factors is developed to analyze the approximate F test by degrees of freedom given by Satterthwaite and point estimation of precisions from expected mean square. The model developed in this paper can be extended to the three useful models according to the type of nested designs. The study also provides the three-step procedures to evaluate the measurement precisions using three indexes such as SNR(Signal-To-Noise Ratio), R&R TR(Reproducibility&Repeatability-To-Total Precision Ratio), and PTR(Precision-To-Tolerance Ratio), The procedures include the identification of resolution, the improvement of R&R reduction, and the evaluation of precision effect.

회분식 혐기성 소화 반응기에서 음식물탈리액과 양돈폐수의 혼합비에 따른 수소 생산 및 유기물 제거 (Hydrogen Production and Organic Removal according to Mixture Ratio of Food Wastewater and Swine Wastewater using Anaerobic Batch Reactor)

  • 김충곤;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.641-647
    • /
    • 2007
  • This study aims to find out optimum condition for hydrogen production and organic removal when treating food and swine wastewater together. For this purpose, various batch tests were conducted by changing mixture ratio from 6:4 (food wastewater:swine wastewater) to 1:9 without pretreatment process. For hydrogen production through anaerobic fermentation, the mixture ratios of R-1 (6:4), R-2 (5:5) and R-6 (1:9) were out of pH range appropriate for hydrogen production and mixture ratios of R-3 (4:6), R-4 (3:7), and R-5(2:8) showed appropriate hydrogen production where their pH ranges were 5.1~5.5. Especially in case of R-3, it consistently maintained appropriate pH range for hydrogen production for 72hr and produced maximum hydrogen. The characteristics of hydrogen production and cumulative hydrogen production according to each mixture ratio showed that R-1, R-2 and R-6 did not produce any hydrogen, and maximum hydrogen productions of R-3, R-4 and R-5 were 593ml, 419ml and 90ml, respectively. Total cumulative hydrogen productions of R-3, R-4 and R-5 were 1690ml, 425ml and 96ml, respectively. Based on previous results, it was concluded that, the most appropriate mixture ratio of food wastewater and swine wastewate rwas 4:6 (R-3). The experiment for COD removal rate to evaluate organic removal efficiency revealed that R-3, R-4 and R-5 showed high removal efficiencies during the highest hydrogen production amount and the highest efficiency was 41% with R-3.

비대칭 압연과 열처리한 Cu 판의 집합조직과 소성변형비 변화 (I) (Changes of Texture and Plastic Strain Ratio of Asymmetrically Rolled and Annealed Cu Sheet (I))

  • 이철우;이동녕;김인수
    • 소성∙가공
    • /
    • 제28권6호
    • /
    • pp.354-360
    • /
    • 2019
  • The plastic strain ratio is one of the factors that affect the deep drawability of metal sheets. The plastic strain ratio of fully annealed Cu sheet is low because its texture has {001}<100>. In order to improve the deep drawability of Cu sheet, it is necessary to increase the plastic strain ratio of Cu sheet. This study investigate the increase of plastic strain ratio of a Cu sheet after the first asymmetry rolling and annealing, and the second asymmetry rolling and annealing in air and Ar gas conditions. The average plastic strain ratio (Rm) was 0.951 and |ΔR| value was 1.27 in the initial Cu sheet. After the second 30.1% asymmetric rolling and annealing of Cu sheet at 1000℃ in air condition, the average plastic strain ratio (Rm) was 1.03 times higher. However, |ΔR| was 0.12 times lower than that of the initial specimen. After the second 18.8% asymmetric rolling and annealing of Cu sheet at 630℃ in Ar gas condition, the average plastic strain ratio (Rm) was 1.68 times higher and |ΔR| was 0.82 times lower than that of the initial specimen. These results are attributed to the change of the texture of Cu sheet due to the different annealing conditions.

팽창밸브 개폐용 감온통 혼합가스의 첨가제 연구 (A Study on the Additives of mixed Gas charged in Thermostatic Bulb for Expansion Valve)

  • 김시영;주창식;구수진
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.126-132
    • /
    • 2014
  • The P-T characteristics of mixed refrigerant in thermostatic expansion valve sensing bulb were studied using R-134a and R-410A refrigerant. The characteristics of mixed refrigerant were investigated according to pressure variation and the variation of composition ratio of R-134A and R-410A in the temperature range of $-15^{\circ}C{\sim}15^{\circ}C$. The Thermodynamic characteristic values of the mixed refrigerants were identified using the characteristic value analysis program of mixed refrigerant(Refrop v9.0, NIST). The P-T characteristics in the case of the mixing ratio of 90:10 for R-410A and R-134A were the same result as R-22. And the physical properties showed similar results with R-22. The Maximum operating pressure(MOP) of mixed refrigerant showed a tendency to decrease with decreasing the mixing ratio of additive gases($N_2$ or He) gases. The characteristics in the case of the mixing ratio of 80:1 for mixed refrigerant and additive gases were the similar result as Reference refrigerant.(R-22 MOP, Sporlan company) In addition $N_2$ and He, both showed the same results. It was able to confirm that a MOP on the thermostatic expansion valve sensing bulb can be maintained by adjusting the mixing ratio of mixed refrigerant gases and additive gases.

한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계 (Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$)

  • 정관옥;남기용
    • The Korean Journal of Physiology
    • /
    • 제3권1호
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

가스 교환비(R)를 구하는 노모그람 (Gas Exchange Ratio (R) Nomogram)

  • 황기준
    • The Korean Journal of Physiology
    • /
    • 제1권1호
    • /
    • pp.73-76
    • /
    • 1967
  • A nomogram of gas exchange ratio (R) in air breathing subjects ,was porposed which enables a simple and rapid determination of R value using the fractional concentrations of nitrogen and carbon dioxide in the expired or alveolar gas. The readable limit of R value seems less than 1/100 of R unit and the average difference between the values from the nomogram and the actually calculated values is less than 0.005 of R unit. The usefulness of this nomogram for rapid and frequent determinations of the oxygen uptake is also suggested.

  • PDF

초음파 시험에 의한 콘크리트의 조기 강도 판정에 관한 연구 (The Study on Earlier Evaluation of Concrete Strength Using Ultra Sonic Velosity Method)

  • 김화중;이도헌;윤상천;박정민;최신호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.136-141
    • /
    • 1995
  • The early evaluation on strength of concrete is useful to achieve on quality control and improvement of properties of concrete. Especially, we could say that the confidence of construction is increased by the increase durability and safety building, due to early evaluation. In this study, was proposed to ultra-sonic pulse method as a early evaluation method for strength of concrete with main parameter, sush as W/C ratio and S/A ratio. The experiment results are summarized to follow as : $\circled1$ The ultra-sonic pulse was decreased as the increase of W/C ratio. $\circled2$ The maximum value for the ultra-sonic pulse velocity and compressive strength was presented in the case of 40% S/A ratio and these value was decreased as the change of S/A ratio over 40% $\circled1$ The relationship of the ultra-sonic pulse velocity and compressive strength on 28days according to the change of W/C and S/A ratio is to be: $F_{28} = -209193R^2 + 384417R - 1763441$(W/C Ratio) $F_{28} = 1726R^2 - 774R - 502 (S/A Ratio)

  • PDF

위험측정치와 VaR헤지의 유효성 (Risk Measures and the Effectiveness of Value-at-Risk Hedging)

  • 문창권;임춘호
    • 통상정보연구
    • /
    • 제9권2호
    • /
    • pp.65-86
    • /
    • 2007
  • This paper reviews the properties and application methods of widely used types of risk measures, identifies the rationale and business-side effects of hedging, derives the theoretical formula of optimal hedging ratio, and analyzes the various functional aspects of VaR(Value-at-risk) as a risk measure and a hedging tool. Especially this paper focuses on the characteristics of VaR compared with other risk measures in terms of their own principal determinants and identifies its stronger aspects in the dimension of hedging strategy tools. As well, this paper provides the detailed processes deriving the optimal hedge ratios based on the distributional parameters and risk factors. In addition, this paper presents the detailed and substantial processes of estimating the minimum variance hedge ratio and minimum-VaR hedge ratio using the actual data and shows that the minimum variance hedge ratio proves helpful for many cases although it is not appropriate for the non-linear portfolio including the option contracts. We demonstrate the trade-off relationship between the minimum variance hedge strategy and the minimum-VaR hedge strategy in their hedging costs and performances through calculation of the respective VaRs and variances of unhedged and hedged portfolios and the optimal hedge ratio and hedging effectiveness values for the given long position in US Dollar with the short position in Euro.

  • PDF

PSN-PMN-PZT 세라믹스의 유전 및 압전 특성과 공진 주파수의 온도안정성 (Dielectric, Piezoelectric Properties and Temperature Stability of Resonant Frequency in PSN-PMN-PZT Ceramics)

  • 윤광희;류주현;민석규;이명수;서성재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.391-395
    • /
    • 2000
  • In this study, the temperature coefficient of resonant frequency(TC $F_{r}$), dielectric and piezoelectric properties of Pb[(S $b_{1}$2/N $b_{1}$2/)$_{0.0035}$-(M $n_{1}$3/N $b_{2}$3/)$_{0.0065}$-(Z $r_{x}$ $Ti_{1-x}$ )$_{0.90}$] $O_3$ceramics is investigated with Zr/Ti ratio. The dielectric constant and electromechanical coupling factor( $k_{p}$) showed the highest values of 1257, 0.562 respectively when the Zr/Ti ratio is 49.5/50.5. The mechanical quality factor( $Q_{m}$) is the lowest value of 713 when the Zr/Ti ratio is 49.5/50.5, and increased with the decrease of the Zr/Ti ratio. The temperature coefficient of resonant frequency(TC $F_{r}$) change abruptly at the morphotropic phase boundary(MPB), which is between the rhombohedral phase with highly negative TC $F_{r}$ of -106ppm/$^{\circ}C$ and the tetragonal phase with highly positive TC $F_{r}$ of +64pp $m^{\circ}C$ as Zr/Ti ratio changes from 50/50 to 49.5/50.5.50.5..5.50.5.5.

  • PDF

가시광선 및 근적외선 스펙트럼을 이용한 도정비율 측정 (Measurement of Milling Ratio using the Visible and the Near-Infrared Rays Spectrum)

  • 이용국;이재현
    • Journal of Biosystems Engineering
    • /
    • 제24권3호
    • /
    • pp.259-266
    • /
    • 1999
  • This research was carried out to investigate the possibility of real time rice milling ratio measurement using the spectral reflection characteristics. In this study, various methods were compared such as \circled1 using the whiteness meter, \circled2 using the colorimeter, \circled3 using the Visible and the NIR reflection spectrum. The samples were milled in the domain of 84~96% by 0.5% interval classified by milling ratio. The NMG treatment method required about 20 minutes to determine the milled ratio and r2 was 0.0028 to 0.7959 that was very low. In case of whiteness meter, r2 was high but speed of measurement was 5 minutes that was very low. Measurement with the colorimeter required about 5 minutes and r2 was 0.60 to 0.85 that was low. The reflection spectrum were measured in the range of 400~2,500nm with 2nm interval and the MLR model with six-wavelength obtained from first derivative of spectra gave the best results(r2 = 0.967, SEP = 0.729%)

  • PDF