• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.029 seconds

Utilization of the Unlinked Case Proportion to Control COVID-19: A Focus on the Non-pharmaceutical Interventional Policies of the Korea and Japan

  • Yeri Jeong;Sanggu Kang;Boeun Kim;Yong Jin Gil;Seung-sik Hwang;Sung-il Cho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.56 no.4
    • /
    • pp.377-383
    • /
    • 2023
  • Objectives: Korea and Japan have managed the spread of coronavirus disease 2019 (COVID-19) using markedly different policies, referred to as the "3T" and "3C" strategies, respectively. This study examined these differences to assess the roles of active testing and contact tracing as non-pharmaceutical interventions (NPIs). We compared the proportion of unlinked cases (UCs) and test positivity rate (TPR) as indicators of tracing and testing capacities. Methods: We outlined the evolution of NPI policies and investigated temporal trends in their correlations with UCs, confirmed cases, and TPR prior to the Omicron peak. Spearman correlation coefficients were reported between the proportion of UCs, confirmed cases, and TPR. The Fisher r-to-z transformation was employed to examine the significance of differences between correlation coefficients. Results: The proportion of UCs was significantly correlated with confirmed cases (r=0.995, p<0.001) and TPR (r=0.659, p<0.001) in Korea and with confirmed cases (r=0.437, p<0.001) and TPR (r=0.429, p<0.001) in Japan. The Fisher r-to-z test revealed significant differences in correlation coefficients between the proportion of UCs and confirmed cases (z=16.07, p<0.001) and between the proportion of UCs and TPR (z=2.12, p=0.034) in Korea and Japan. Conclusions: Higher UCs were associated with increases in confirmed cases and TPR, indicating the importance of combining testing and contact tracing in controlling COVID-19. The implementation of stricter policies led to stronger correlations between these indicators. The proportion of UCs and TPR effectively indicated the effectiveness of NPIs. If the proportion of UCs shows an upward trend, more testing and contact tracing may be required.

Pasting Properties and Gel Strength of Non-Waxy Rice Flours Prepared by Heat-Moisture Treatment (수분-열처리로 제조한 멥쌀가루의 호화 특성과 겔 강도)

  • Seo, Hye-In;Kim, Chang-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.2
    • /
    • pp.196-204
    • /
    • 2011
  • Heat-moisture treatment (HMT) was applied to 4 samples of rice flours, Goami (GM), Taeguk (TG), Choochung (CC) and Koshihikari (KSHK), of which amylose contents were 31.5, 32.3, 24.3, and 23.3%, respectively. Wet-milled rice flours were dried, moisture content adjusted to 21, 24, 27 and 30%, respectively, and autoclaved at 100 and $105^{\circ}C$ for 30~90 min. The changes on swelling, solubility, RVA (rapid visco analyser) paste viscosities and gel strength were observed. In GM and TG, peak viscosity (PV) and breakdown (BD) decreased and no peak appeared as moisture and treatment time increased by HMT. In CC, FV increased notably with big increase of PV and setback (SB) by HMT compared to the other rice flours. BD in all the samples decreased as moisture, temperature, and time increased by HMT. RVA pasting properties of HMT GM and HMT TG were changed remarkably under conditions of moisture 21%, $100^{\circ}C$ and 30 min whereas for HMT CC and HMT KSHK, higher temperature or more time was required at the same mois ture levels. The swelling power, solubility and gel strength increased by HMT. Gel strength correlated positively with SB (r=0.78, p<0.01) and negatively with BD (r=-0.71, p<0.01) and PV (r=-0.36, p<0.05) resulting from strengthening the structure of starch granules in rice flours by HMT.

Effect of Ethane 1,2-Dimethane Sulfonate(EDS) on the Expression of Pituitary Gonadotropin in Male Rats (수컷 흰쥐 뇌하수체의 생식소자극호르몬 발현에 미치는 Ethane 1,2-Dimethane Sulfonate(EDS)의 효과)

  • Son, Hyeok-Joon;Kim, Soo-Woong;Paick, Jae-Seung;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2007
  • Ethane 1,2-dimethane sulfonate(EDS), a toxin which specifically kills Leydig cells(LC), has been widely used to prepare the reversible testosterone(T) depletion rat model. In the present study, we monitored the gene expression profiles of pituitary gonadotropins, LH and FSH, up to 7 weeks after EDS injection. Adult male Sprague-Dawley rats($300{\sim}350\;g$ B.W.) were injected with a single dose of EDS(75 mg/kg i.p.) and sacrificed on weeks 0, 1, 2, 3, 4, 5, 6 and 7. Total RNAs were purified from each pituitary, and the message levels of common alpha subunit($C{\alpha}$) of pituitary glycoprotein hormones, LH beta subunit($LH{\beta}$), FSH beta subunit($FSH{\beta}$) and GnRH receptor(GnRH-R) were evaluated by semi-quantitative RT-PCRs. The message levels of $C{\alpha}$ increased sharply during weeks 1-4, then return to the control level on week 5. The mRNA levels of $LH{\beta}$ were elevated after week 2, reached the peak at week 4, then declined to the control level after week 5. The message levels of $FSH{\beta}$ were elevated after week 2, reached the peak at week 3, then declined to the nadir at week 5. Similarly, the mRNA levels of GnRH-R were elevated after week 2, reached the peak at week 3, then gradually declined to the control level after week 5. The present study indicated that EDS treatment could induce reversible alterations in the transcriptional activities of gonadotropin subunits and GnRH-R in the anterior pituitary from male rats. EDS injection model might be useful to understand the mechanism of hormonal regulation of hypothalamus- pituitary neuroendocrine axis in male rats.

  • PDF

The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation (Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향)

  • Choi, Won-Jun;Jung, Sung-Han;Lee, Jeong-A;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1022-1030
    • /
    • 1998
  • Background : In volume-controlled ventilation, the use of inspiratory pause increases the inspiratory time and thus increases mean airway pressure and improves ventilation. But under the same I : E ratio, the effects of inspiratory pause on mean airway pressure and gas exchange are not certain. Moreover, the effects may be different according to the resistance of respiratory system. So we studied the effects of inspiratory pause on airway pressure and gas exchange under the same I : E ratio in volume-controlled ventilation. Methods: Airway pressure and arterial blood gases were evaluated in 12 patients under volume-controlled mechanical ventilation with and without inspiratory pause time 5%. The I : E ratio of 1 : 3, $FiO_2$, tidal volume, respiratory rate, and PEEP were kept constant. Results: $PaCO_2$ with inspiratory pause was lower than without inspiratory pause ($38.6{\pm}7.4$ mmHg vs. $41.0{\pm}7.7$ mmHg. p<0.01). P(A-a)$O_2$ was not different between ventilation with and without inspiratory pause $185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, p=0.766). Mean airway pressure with inspiratory pause was higher than without inspiratory pause ($9.7{\pm}4.0\;cmH_2O$ vs. $8.8{\pm}4.0\;cmH_2O$, p<0.01). The resistance of respiratory system inversely correlated with the pressure difference between plateau pressure with pause and peak inspiratory pressure without pause (r=-0.777, p<0.l), but positively correlated with the pressure difference between peak inspiratory pressure with pause and peak inspiratory pressure without pause (r=0.811, p<0.01). Thus the amount of increase in mean airway pressure with pause positively correlated with the resistance of respiratory system (r=0.681, p<0.05). However, the change of mean airway pressure did not correlated with the change of $PaCO_2$. Conclusion: In volume-controlled ventilation under the same I : E ratio of 1 : 3, inspiratory pause time of 5% increases mean airway pressure and improves ventilation. Although the higher resistance of respiratory system, the more increased mean airway pressure, the increase in mean airway pressure did not correlated with the change in $PaCO_2$.

  • PDF

Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model (골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구)

  • Kwon, Taek-Ka;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.128-137
    • /
    • 2011
  • Purpose: Resonance frequency analysis, Periotest, and removal torque (RT) test were known as the methods to assess implant stability. The results of these methods are affected by the bone condition, implant diameter and shape. The purpose of this study is to access the meaning and the correlationship of the resonance frequency analysis, Periotest and RT test in osseointegration simulated acrylic resin when the engaged bone thickness and peri-implant bone defect are changed. Materials and methods: To simulate osseointegration, the fixture was fixed to an aluminum mold with a screw. Acrylic resin powder and liquid were poured into the mold for polymerization. The engaged resin thickness with implant was controlled. Simulated cortical bone thicknesses were 1, 3, 5 and 10 mm. Additional 1, 3 and 5 mm peri-implant bone defects were simulated. Three types of implants were used; 4 mm diameter implants of straight shape, 4 mm diameter implants of tapered shape and 5 mm diameter implants of tapered shape. Five fixtures per each type were tested in respective bone condition. Resonance frequency analysis and Periotest were evaluated in all bone conditions. Peak removal torque was measured at simulated cortical bone thicknesses of 1 and 3 mm. The statistical analysis was performed with the Kruskal-Wallis test, Mann-Whitney U test, and Spearman test using a 95% level of confidence. Results: With increasing engaged bone depth, the Implant Stability Quotient (ISQ) values increased and the Periotest values (PTVs) decreased (P<.001, P<.001). With increasing peri-implant bone defect, ISQ values decreased and PTVs increased (P<.001). When the diameter of implant increased, ISQ values increased and Periotest values (PTV) decreased (P<.001). There was a strong correlation between ISQ values and PTVs (r = -0.99, P<.001). Furthermore, the peak removal torque values had weak correlations with both ISQ values and PTVs (r = 0.52, P<.001 ; r = -0.52, P<.001). Conclusion: This study confirmed favorable implant stability with increasing engaged bone depth and implant diameter and decreasing peri-implant bone defect. ISQ values and PTVs showed strong correlation with each other and not with the peak removal torque values.

Characterization of few-layered reduced graphene oxide (rGO) for standardization (소수의 층을 갖는 환원 graphene oxide(rGO) 표준화를 위한 물성분석)

  • Ahn, Hae Jun;Huh, Seung Hun;Jee, Youngho;Lee, Byeong Woo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.6
    • /
    • pp.239-245
    • /
    • 2022
  • Reduced graphene oxide (rGO) has attracted many attention and applications due to its excellent electrochemical ability. Therefore, standardization of rGO through structural and thermal analysis facilitates quality improvement and management, enabling users to increase efficiency and reduce relevant costs. For rGO and graphene-related materials, it is very important to determine the number of layers and define the resulting difference in physical properties. In this study, 3~4 layers of rGO-1 and 9~10 layers of rGO-2 were obtained from graphene oxide (GO) through a hydrazine reduction process. For the prepared rGOs, X-ray diffraction (XRD) pattern obtained a diffraction peak at 2θ≈25° related to (002) reflection was used to calculate the layer numbers by determining interlayer distance and FWHM value. To reduce the angular uncertainty, XRD data analysis was performed with angle correction using standard reference materials for X-ray powder diffraction analysis. Precise interlayer distance and number of layers were determined using OriginLab and open-source XRD diffraction analysis programs using the angle-corrected diffraction data. TG-DSC thermal analysis was performed to further standardize the physical properties of rGO samples.

Blood Urea Nitrogen as an Index of Feed Efficiency and Lean Growth Potential in Growing-Finishing Swine

  • Whang, K.Y.;Easter, R.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.6
    • /
    • pp.811-816
    • /
    • 2000
  • Five experiments were conducted to evaluate blood urea nitrogen (BUN) as a potential index of feed efficiency (G/F) and lean growth in growing-finishing pigs. Exp. 1 was conducted to examine the relationship between feeding protocol and BUN values. Fasted-refed pigs exhibited BUN peaks 3 h post-prandially while those given ad libitum access to diet had inconsistent BUN patterns in 10 h blood sampling with an 1 h interval. In Exp. 2 and 3, it was revealed that the peak BUN values were negatively correlated (p<0.01) with G/F in both barrows and gilts at 20 kg body weight (BW) and 50 kg to 90 kg BW. In Exp. 4, it was found that BUN values between 55 kg and 70 kg BW, when lean gain is maximized, were best correlated with average daily lean gain (ADLG). In Exp. 5, 18 barrows and 21 gilts were used to examine the relationship between BUN values at 65 kg BW and ADLG from birth to market weight. The BUN values at 65 kg BW and ADLG were negatively correlated (p<0.01) in both genders. These experiments demonstrated that there was a correlation between peak BUN values, and G/F and ADLG under specific circumstances.

A Study on Correlationship between the Induced Plasma and Emission Signals for In-process Monitoring in Stainless Steel Welding of Fiber Laser (II) - Properties Changes of the Measured Signals in a Thick Plate Welding - (파이버 레이저의 스테인리스강 용접시 인프로세스 모니터링을 위한 유기 플라즈마와 방사신호간의 상관성 연구(II) - 후판 용접시 측정신호의 특성 변화 -)

  • Lee, Chang-Je;Kim, Jong-Do
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.70-74
    • /
    • 2014
  • On this study, we researched the in-process monitoring during fiber laser welding as well as on the first paper. On the previous/formal study, we analyzed the change of emission signal on thin plate welding. On this study, however, we analyzed RMS and FFT with emission signals in laser welding on lap joint and butt joint of 8mm-thick 316L stainless steel. As the result, the movement of specific frequency peak was observed according to welding speed changes. Furthermore, frequency peak as a result of FFT on the thick plate welding are much clearer than on the thin plate welding. Therefore, it is expected that the welding parameter changes can be predicted in case of applying FFT to in-process monitoring.

Production of Novel Cell-Associated Tannase from Newly Isolated Serratia ficaria DTC

  • Belur, Prasanna D.;Gopal, Mugeraya;Nirmala, K.R.;Basavaraj, N.
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.4
    • /
    • pp.732-736
    • /
    • 2010
  • Five strains of tannic acid degrading bacteria were isolated and identified by phenotypic characterization. All the five isolates showed cell-associated activity, whereas only three showed extracellular activity. Serratia ficaria DTC, showing the highest cell-associated activity (0.29 U/l), was selected for further shake-flask studies. Tannase synthesis was growth associated and reached the peak in the late stationary phase of growth. Organic nitrogen sources enhanced the tannase production. Peak tannase production of 0.56 U/l was recorded in the medium having the initial pH of 6. The pH and temperature optima of the enzyme were found to be 8.9 and $35^{\circ}C$, respectively. This is the first report of cell-associated activity in the case of bacterial tannase. Cell-associated tannase of Serratia ficaria DTC could be industrially important from the perspective of its activity at broad temperature and pH ranges, and its unusually high activity at pH 8.9.

Femtosecond Pulsed Laser Ablation of OLED Shadow Mask Invar Alloy (펨토초 레이저를 이용한 OLED 용 Shadow Mask Invar 합금의 어블레이션)

  • Chung, Il-Young;Kang, Kyung-Ho;Kim, Jae-Do;Sohn, Ik-Bu;Noh, Young-Chul;Lee, Jong-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.12
    • /
    • pp.50-56
    • /
    • 2007
  • Femtosecond laser ablation of the Invar alloy and hole drilling for a shadow mask are studied. We used a regenerative amplified Ti-sapphire laser with a 1kHz repetition rate, 184fs pulse duration and 785nm wavelength. Femtosecond laser pulse was irradiated on the Invar alloy with air blowing at the condition of various laser peak power. An ablation characteristic of the Invar alloy was appeared non-linear at $125J/cm^2$ of energy fluence. For the application to a shadow mask, the hole drilling of the Invar alloy with the cross section of a trapezoidal shape was investigated. The ablated micro-holes were characterized using an atomic force microscopy(AFM). The optimal condition of hole pattern f3r a shadow mask was $4\;{\mu}m$ z-axis feed rate, 0.2mm/s circular velocity, $26.4{\mu}J$ laser peak power. With the optimal processing condition, the fine circular hole shape without burr and thermal damage was achieved. Using the femtoseocond laser system, it demonstrates excellent tool for the Invar alloy micro-hole drilling without heat effects and poor edge.