• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.03 seconds

Measurement of deuterium concentration in heavy water utilizing prompt gamma neutron activation analysis (PGNAA) in comparison with MCNPX simulation results

  • Saeed Salahi;Mahdieh Mokhtari Dorostkar ;Akbar Abdi Saray
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4231-4235
    • /
    • 2022
  • Considering the importance of deuterium in nuclear science including medical and industrial researches such as (BNCT) and nuclear reactors respectively, it is important to study various possible ways in addition to common methods for measuring its concentration. This study is an effort to measure deuterium concentration using PGNAA. The main idea is to calculate the area under 2.23 MeV gamma-rays photo peak resulting from neutron collision with Hydrogen atoms which are in mix with deuterium in samples. The study carried out by both simulation and experiment. Monte Carlo MCNPX2.6 code has been used for simulation and based on its acceptable results an experimental setup has been arranged. The coordination of results was in the range of R = 0.99 and R = 0.98 in simulation and experiment respectively. The accuracy of the study has been investigated by measuring the concentration of an unknown sample by both PGNAA and Fourier transform infrared spectroscopy (FT-IR) methods in which there were acceptable correlation between these two methods.

The Effect of Stress Ratio on Fatigue Crack Propagation Rate and Arrest Behavior in 7075-T735 Al Alloy (7075-T735 Al 합금의 피로균열 진전속도와 정류거동에 미치는 응력비의 영향)

  • 오세욱;강상훈;허정원;김태형
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.131-139
    • /
    • 1992
  • The understanding and appllication of fatigue crack propagation mechanism in variable amplitude loading is very important for life prediction of the air travel structures. Particularly, the retardation and arrest behavior of fatigue crack propagation by single tension overloading is essential to the understanding and appllication of fatigue crack propagation mechanism in variable amplitude loading. Numerous studies of the retardation behavior have been performed, however investigations of the arrest behavior have not been enough yet. As for the arrest behavior, Willenborg had reported that the overload shut-off ratio $[R_{so}=(K_{OL})/K_{max})_{crack arrest}]$ had been the material constant, but recently several investigators have reported that the overload shut-off ratio depends upon the stress ratio. In this study, authors have investigated the effect of stress ratio on the threshold overload shut-off ratio to generate arrest of fatigue crack growth in high tensile aluminum alloy 7075-T735 which have used in material for air travel structures, It has been $-0.4\leqqR\leqq0.4$ till now, the region of stress ratio investigated. The threshold overload shut-off ratio has decreased as stress ratio has increased in overall region of -$-0.4\leqqR\leqq0.4$ and the linearity has been seen in this material. Moreover, the experimental equation between $R_{so}$ and R has been made; The relation has been $R_{so}=-R+2.6$.

  • PDF

Study of the longitudinal reinforcement in reinforced concrete-filled steel tube short column subjected to axial loading

  • Alifujiang Xiamuxi;Caijian Liu;Alipujiang Jierula
    • Steel and Composite Structures
    • /
    • v.47 no.6
    • /
    • pp.709-728
    • /
    • 2023
  • Experimental and analytical studies were conducted to clarify the influencing mechanisms of the longitudinal reinforcement on performance of axially loaded Reinforced Concrete-Filled Steel Tube (R-CFST) short columns. The longitudinal reinforcement ratio was set as parameter, and 10 R-CFST specimens with five different ratios and three Concrete-Filled Steel Tube (CFST) specimens for comparison were prepared and tested. Based on the test results, the failure modes, load transfer responses, peak load, stiffness, yield to strength ratio, ductility, fracture toughness, composite efficiency and stress state of steel tube were theoretically analyzed. To further examine, analytical investigations were then performed, material model for concrete core was proposed and verified against the test, and thereafter 36 model specimens with four different wall-thickness of steel tube, coupling with nine reinforcement ratios, were simulated. Finally, considering the experimental and analytical results, the prediction equations for ultimate load bearing capacity of R-CFSTs were modified from the equations of CFSTs given in codes, and a new equation which embeds the effect of reinforcement was proposed, and equations were validated against experimental data. The results indicate that longitudinal reinforcement significantly impacts the behavior of R-CFST as steel tube does; the proposed analytical model is effective and reasonable; proper ratios of longitudinal reinforcement enable the R-CFSTs obtain better balance between the performance and the construction cost, and the range for the proper ratios is recommended between 1.0% and 3.0%, regardless of wall-thickness of steel tube; the proposed equation is recommended for more accurate and stable prediction of the strength of R-CFSTs.

Effect of bone-implant contact pattern on bone strain distribution: finite element method study (골-임플란트 접촉 양상에 따른 골 변형 연구: 유한요소법적 연구)

  • Yoo, Dong-Ki;Kim, Seong-Kyun;Koak, Jai-Young;Kim, Jin-Heum;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.214-221
    • /
    • 2011
  • Purpose: To date most of finite element analysis assumed the presence of 100% contact between bone and implant, which is inconsistent with clinical reality. In human retrieval study bone-implant contact (BIC) ratio ranged from 20 to 80%. The objective of this study was to explore the influence of bone-implant contact pattern on bone of the interface using nonlinear 3-dimensional finite element analysis. Materials and methods: A computer tomography-based finite element models with two types of implant (Mark III Br${\aa}$nemark$^{(R)}$, Inplant$^{(R)}$) which placed in the maxillary 2nd premolar area were constructed. Two different degrees of bone-implant contact ratio (40, 70%) each implant design were simulated. 5 finite element models were constructed each bone-implant contact ratio and implant design, and sum of models was 40. The position of bone-implant contact was determined according to random shuffle method. Elements of bone-implant contact in group W (wholly randomized osseointegration) was randomly selected in terms of total implant length including cortical and cancellous bone, while ones in group S (segmentally randomized osseointegration) was randomly selected each 0.75 mm vertically and horizontally. Results: Maximum von Mises strain between group W and group S was not significantly different regardless of bone-implant contact ratio and implant design (P=.939). Peak von Mises strain of 40% BIC was significantly lower than one of 70% BIC (P=.007). There was no significant difference between Mark III Br${\aa}$nemark$^{(R)}$ and Inplant$^{(R)}$ in 40% BIC, while average of peak von Mises strain for Inplant$^{(R)}$ was significantly lower ($4886{\pm}1034\;{\mu}m/m$) compared with MK III Br${\aa}$nemark$^{(R)}$ ($7134{\pm}1232\;{\mu}m/m$) in BIC 70% (P<.0001). Conclusion: Assuming bone-implant contact in finite element method, whether the contact elements in bone were wholly randomly or segmentally randomly selected using random shuffle method, both methods could be effective to be no significant difference regardless of sample size.

Synthesis and Properties of High Impact Polystyrene Nanocomposites Based upon Organoclay Having Reactive Group (반응성 유기화 점토를 이용한 내충격성 폴리스티렌 나노복합재료의 합성 및 물성)

  • Hwang, Sung-Jung;Chung, Dae-Won;Lee, Seong-Jae
    • Polymer(Korea)
    • /
    • v.32 no.4
    • /
    • pp.347-352
    • /
    • 2008
  • High impact polystyrene (HIPS) nanocomposites with organically modified montmorillonite (organoclay) via in situ polymerization were synthesized, and the effects of organoclay incorporation on material properties were investigated. Organoclays having a reactive group, vinylbenzyltrimethyl clay (VBC) and octadecylvinylbenzyldimethyl clay (ODVC), were prepared by the ion-exchange reactions of sodium montmorillonite with vinylbenzyltrimethyl ammonium chloride (VBTMAC) and octadecylvinylbenzyldimethyl ammonium bromide (ODVBDAB), respectively, and a commercial organoclay, $Cloisite^{(R)}$ 10A(C10A), was used for comparison. It was confirmed that the X-ray diffraction (XRD) peak of the nanocomposites prepared by ODVC disappeared, which indicates the exfoliation of silicate layers. On the contrary, the XRD peak of the nanocomposites prepared by C10A shifted to lower angle, indicative of the intercalation of polymer chains into silicate layers. Rheological properties such as storage modulus and complex viscosity increased with increasing organoclay.

Comparison of Mathematical Models Applied to F1 Dairy Sheep Lactations in Organic Farm and Environmental Factors Affecting Lactation Curve Parameter

  • Angeles-Hernandez, J.C.;Albarran-Portillo, B.;Gomez Gonzalez, A.V.;Pescador Salas, N.;Gonzalez-Ronquillo, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.8
    • /
    • pp.1119-1126
    • /
    • 2013
  • The objective of this study was to compare the goodness of fit of four lactation curve models: Wood's Gamma model (WD), Wilmink (WL), and Pollott's multiplicative two (POL2) and three parameters (POL3) and to determine the environmental factors affecting the complete lactation curve of F1 dairy sheep under organic management. A total of 5,382 weekly milk yields records from 150 ewes, under organic management were used. Residual mean square (RMS), determination coefficients ($R^2$), and correlation (r) analysis were used as an indicator of goodness of fit for each model. WL model best fitted the lactation curves as indicated by the lower RMS values (0.019), followed by WD (0.023), POL2 (0.025) and POL3 (0.029). The four models provided total milk yield (TMY) estimations that were highly correlated (0.93 to 0.97) with observed TMY (89.9 kg). The four models under estimated peak yield (PY), whereas POL2 and POL3 gave nearer peak time lactation estimations. Ewes lambing in autumn had higher TMY and showed a typical curve shape. Higher TMY were recorded in second and third lambing. Season of lambing, number of lambing and type of lambing had a great influenced over TMY shaping the complete lactation curve of F1 dairy sheep. In general terms WL model showed the best fit to the F1 dairy sheep lactation curve under organic management.

Characteristics of Redox Flow Battery Using the Soluble Lead Electrolyte (납이 용해된 전해액을 사용하는 레독스 플로우 전지의 특성)

  • An, Sang-Yong;Kim, Eung-Jin
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.214-218
    • /
    • 2011
  • The electrochemical characteristics and performance of redox flow battery using the soluble lead has been evaluated. Cyclic voltammetry was performed on the materials to evaluate deposition and dissolution of lead and lead dioxide. In the negative region, a reduction peak is not observed, and on the reverse scan, on-set voltage is observed at -0.47 V(vs SCE). In the positive region, the distinct peak is observed on the forward and reverse scan. The charge/discharge experiments were carried out graphite electrode in the beaker cell. The charging(deposition) of lead occurs at around 0.5 V(vs SCE) and discharging(dissolution) of lead occur at around 0.25 V(vs SCE). The potential difference is about 0.25 V. The charging(deposition) of dioxide lead is at 1.77 V(vs SCE) and discharging(dissolution) is at around 0.95 V(vs SCE) during first cycle. On subsequent cycles, the charging of dioxide lead starts at below 1.5 V(vs SCE), after a period the voltage increase to 1.7 V(vs SCE). The voltage of discharging is stable at around 1.0 V(vs SCE).

Basic Physiological Research on the Wing Flapping of the Sweet Potato Hawkmoth Using Multimedia

  • Nakajima, Isao;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.189-196
    • /
    • 2020
  • We have developed a device for recording biological data by inserting three electrodes and a needle with an angular velocity sensor into the moth for the purpose of measuring the electromyogram of the flapping and the corresponding lift force. With this measurement, it is possible to evaluate the moth-physiological function of moths, and the amount of pesticides that insects are exposed to (currently LD50-based standards), especially the amount of chronic low-concentration exposure, can be reduced the dose. We measured and recorded 2-channel electromyography (EMG) and angular velocity corresponding to pitch angle (pitch-like angle) associated with wing flapping for 100 sweet potato hawkmoths (50 females and 50 males) with the animals suspended and constrained in air. Overall, the angular velocity and amplitude of EMG signals demonstrated high correlation, with a correlation coefficient of R = 0.792. In contrast, the results of analysis performed on the peak-to-peak (PP) EMG intervals, which correspond to the RR intervals of ECG signals, indicated a correlation between ΔF fluctuation and angular velocity of R = 0.379. Thus, the accuracy of the regression curve was relatively poor. Using a DC amplification circuit without capacitive coupling as the EMG amplification circuit, we confirmed that the baseline changes at the gear change point of wing flapping. The following formula gives the lift provided by the wing: angular velocity × thoracic weight - air resistance - (eddy resistance due to turbulence). In future studies, we plan to attach a micro radio transmitter to the moths to gather data on potential energy, kinetic energy, and displacement during free flight for analysis. Such physiological functional evaluations of moths may alleviate damage to insect health due to repeated exposure to multiple agrochemicals and may lead to significant changes in the toxicity standards, which are currently based on LD50 values.

Cardiac Response to Head-Out Water Immersion in Man

  • Choi, Jang-Kyu;Park, Won-Kun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.3
    • /
    • pp.253-261
    • /
    • 2000
  • Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time intervals. Ten men rested on a siting position in the air and in the water at $34.5^{circ}C$ for 30 min each. Their stroke volume, heart rate, ventricular systolic time intervals, and aortic blood flow indices were assessed by impedance cardiography. During immersion, the stroke volume increased 56%, with a slight (4%) decrease in heart rate, thus cardiac output increased ${\sim}50%.$ The slight increase in R-R interval was due to an equivalent increase in the systolic and diastolic time intervals. The ventricular ejection time was 20% increased, and this was mainly due to a decrease in pre-ejection period (28%). The mean arterial pressure increased 5 mmHg, indicating that the cardiac afterload was slightly elevated by immersion. The left ventricular end-diastolic volume index increased 24%, indicating that the cardiac preload was markedly elevated during immersion. The mean velocity and the indices of peak velocity and peak acceleration of aortic blood flow were all increased by ${\sim}30%,$ indicating that the left ventricular contractile force was enhanced by immersion. These results suggest that the increase in stroke volume during immersion is characterized by an increase in ventricular ejection time and aortic blood flow velocity, which may be primarily attributed to the increased cardiac preload and the muscle length-dependent increase in myocardial contractile force.

  • PDF

Fabrication and structural observation of amorphous V-Co alloy by mechanical alloying (MA법에 의한 V-Co계 비정질합금의 제조 및 구조분석)

  • Lee, Chung-Hyo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • In the present study, we investigated the effect of mechanical alloying (MA) on the formation of amorphous VCo system through solid state reaction during ball milling. Two types of powder samples, ${\sigma}$-VCo intermetallic compound and $V_{50}Co_{50}$ powder mixture, were applied as a starting materials. With increasing milling time, a structural characteristics into the amorphous state is distinctly observed from the structural factor and radial distribution by X-ray diffraction. Amorphization has been observed in all two types of samples after the milling for 120 hrs. DSC spectrum of $V_{50}Co_{50}$ powder sample milled for 60 hrs indicates a sharp exothermic peak from the crystallization at $600^{\circ}C$. The structure factor, S(Q) and radial distribution function, RDF(r), observed by X-ray diffraction gradually change into a structure characteristic of an amorphous state with increasing MA time.