• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.028 seconds

Seismic performance of R/C structures under vertical ground motion

  • Bas, Selcuk;Lee, Jong-Han;Sevinc, Mukadder;Kalkan, Ilker
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.369-380
    • /
    • 2017
  • The effects of the vertical component of a ground motion on the earthquake performances of semi-ductile high-rise R/C structures were investigated in the present study. Linear and non-linear time-history analyses were conducted on an existing in-service R/C building for the loading scenarios including and excluding the vertical component of the ground motion. The ratio of the vertical peak acceleration to the horizontal peak acceleration (V/H) of the ground motion was adopted as the main parameter of the study. Three different near-source earthquake records with varying V/H ratio were used in the analyses. The linear time-history analyses indicated that the incorporation of the vertical component of a ground motion into analyses greatly influences the vertical deflections of a structure and the overturning moments at its base. The lateral deflections, the angles of rotation and the base shear forces were influenced to a lesser extent. Considering the key indicators of vertical deflection and overturning moments determined from the linear time-history analysis, the non-linear analyses revealed that the changes in the forces and deformations of the structure with the inclusion of the vertical ground motion are resisted by the shear-walls. The performances and damage states of the beams were not affected by the vertical ground motion. The vertical ground motion component of earthquakes is markedly concluded to be considered for design and damage estimation of the vertical load-bearing elements of the shear-walls and columns.

A study on the SEI film formation as organic solvent decomposition of lithium ion batteries and its electrochemical behavior (리튬이온전지의 유기용매분해에 따른 SEI film형성과 전기화학적 거동에 관한 연구)

  • 김민성;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.545-549
    • /
    • 2001
  • We have produced electrolyte solution out of 1.15M LiPF$\sub$6/ EC/EMC/DEC/PC(30/55/10/5 by vol%) as a reference, and at the same time, performed basic physical property test using a single solvent of 1.15M LiPF$\sub$6/DEC, DMC, EMC and a 2 component electrolyte solution of 1.15M LiPF$\sub$6/ EC/DEC(1/2 by vo%%) and PC/DEC(1/2 by vol%). Cyclic Voltammetry Analysis showed that, compared to existing carbonate organic solvent, the addition of DEC, DMC and EMC brought the de-decomposition peak of salt anion of PF$\sub$6/$\^$-/ and the solvent at lower oxidization potential of 2.3V, 0.7V and 2.1V(vs. Li/Li$\^$+/\`). In addition, a kinetics current peak, in which intercalation of Li$\^$+/ is proceeded at 750mv, 450mv(vs. Li/Li$\^$+/), was confirmed. These findings suggest that the DEC solvent decomposition occurred at an electric potential lower than that of oxidization of existing carbonate organic solvent. Through the impedance analysis, we checked electric charge transfer resistance(R$\sub$ct/) according to the electric potential of Li$\^$+/ intercalation at 750mv(vs. Li/Li$\^$+/), which was the same as the resistance (R$\sub$f/) and cyclic voltammetry of SEI film that was formed at Reference. By doing so, we found that the significant decrease of polarization resistance(R$\sub$p/) when Reference was played a part in the formation of compact SEI layer at the initial decomposition reaction.

  • PDF

Impact of Activation Functions on Flood Forecasting Model Based on Artificial Neural Networks (홍수량 예측 인공신경망 모형의 활성화 함수에 따른 영향 분석)

  • Kim, Jihye;Jun, Sang-Min;Hwang, Soonho;Kim, Hak-Kwan;Heo, Jaemin;Kang, Moon-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.11-25
    • /
    • 2021
  • The objective of this study was to analyze the impact of activation functions on flood forecasting model based on Artificial neural networks (ANNs). The traditional activation functions, the sigmoid and tanh functions, were compared with the functions which have been recently recommended for deep neural networks; the ReLU, leaky ReLU, and ELU functions. The flood forecasting model based on ANNs was designed to predict real-time runoff for 1 to 6-h lead time using the rainfall and runoff data of the past nine hours. The statistical measures such as R2, Nash-Sutcliffe Efficiency (NSE), Root Mean Squared Error (RMSE), the error of peak time (ETp), and the error of peak discharge (EQp) were used to evaluate the model accuracy. The tanh and ELU functions were most accurate with R2=0.97 and RMSE=30.1 (㎥/s) for 1-h lead time and R2=0.56 and RMSE=124.6~124.8 (㎥/s) for 6-h lead time. We also evaluated the learning speed by using the number of epochs that minimizes errors. The sigmoid function had the slowest learning speed due to the 'vanishing gradient problem' and the limited direction of weight update. The learning speed of the ELU function was 1.2 times faster than the tanh function. As a result, the ELU function most effectively improved the accuracy and speed of the ANNs model, so it was determined to be the best activation function for ANNs-based flood forecasting.

Transcriptional profiles of rock bream iridovirus (RBIV) using microarray approaches

  • Myung-Hwa, Jung;Jun-Young, Song;Sung-Ju, Jung
    • Journal of fish pathology
    • /
    • v.35 no.2
    • /
    • pp.141-155
    • /
    • 2022
  • Rock bream iridovirus (RBIV) causes high mortality and economic losses in the rock bream (Oplegnathus fasciatus) aquaculture industry in Korea. Viral open reading frames (ORFs) expression profiling at different RBIV infection stages was investigated using microarray approaches. Rock bream were exposed to the virus and held for 7 days at 23 ℃ before the water temperature was reduced to 17 ℃. Herein, 28% mortality was observed from 24 to 35 days post infection (dpi), after which no mortality was observed until 70 dpi (end of the experiment). A total of 27 ORFs were significantly up- or down-regulated after RBIV infection. In RBIV-infected rock bream, four viral genes were expressed after 2 dpi. Most RBIV ORFs (26 genes, 96.2%) were significantly elevated between 7 and 20 dpi. Among them, 12 ORF (44.4%) transcripts reached their peak expression intensity at 15 dpi, and 14 ORFs (51.8%) were at peak expression intensity at 20 dpi. Expression levels began to decrease after 25 dpi, and 92.6% of ORFs (25 genes) were expressed below 1-fold at 70 dpi. From the microarray data, in addition to the viral infection, viral gene expression profiles were categorized into three infection stages, namely, early (2 dpi), middle (7 to 20 dpi), and recovery (25 and 70 dpi). RBIV ORFs 009R, 023R, 032L, 049L, and 056L were remarkably expressed during RBIV infection. Furthermore, six ORFs (001L, 013R, 052L, 053L, 058L, and 061L) were significantly expressed only at 20 dpi. To verify the cDNA microarray data, we performed quantitative real-time PCR, and the results were similar to that of the microarray. Our results provide novel observations on broader RBIV gene expression at different stages of infection and the development of control strategies against RBIV infection.

Correlation Between Knee Muscle Strength and Maximal Cycling Speed Measured Using 3D Depth Camera in Virtual Reality Environment

  • Kim, Ye Jin;Jeon, Hye-seon;Park, Joo-hee;Moon, Gyeong-Ah;Wang, Yixin
    • Physical Therapy Korea
    • /
    • v.29 no.4
    • /
    • pp.262-268
    • /
    • 2022
  • Background: Virtual reality (VR) programs based on motion capture camera are the most convenient and cost-effective approaches for remote rehabilitation. Assessment of physical function is critical for providing optimal VR rehabilitation training; however, direct muscle strength measurement using camera-based kinematic data is impracticable. Therefore, it is necessary to develop a method to indirectly estimate the muscle strength of users from the value obtained using a motion capture camera. Objects: The purpose of this study was to determine whether the pedaling speed converted using the VR engine from the captured foot position data in the VR environment can be used as an indirect way to evaluate knee muscle strength, and to investigate the validity and reliability of a camera-based VR program. Methods: Thirty healthy adults were included in this study. Each subject performed a 15-second maximum pedaling test in the VR and built-in speedometer modes. In the VR speedometer mode, a motion capture camera was used to detect the position of the ankle joints and automatically calculate the pedaling speed. An isokinetic dynamometer was used to assess the isometric and isokinetic peak torques of knee flexion and extension. Results: The pedaling speeds in VR and built-in speedometer modes revealed a significantly high positive correlation (r = 0.922). In addition, the intra-rater reliability of the pedaling speed in the VR speedometer mode was good (ICC [intraclass correlation coefficient] = 0.685). The results of the Pearson correlation analysis revealed a significant moderate positive correlation between the pedaling speed of the VR speedometer and the peak torque of knee isokinetic flexion (r = 0.639) and extension (r = 0.598). Conclusion: This study suggests the potential benefits of measuring the maximum pedaling speed using 3D depth camera in a VR environment as an indirect assessment of muscle strength. However, technological improvements must be followed to obtain more accurate estimation of muscle strength from the VR cycling test.

Utility Analysis for Pegfilgrastim in DLBCL Patients on R-CHOP Regimen (항암치료를 받는 미만성거대비세포 림프종 환자에서 페그필그라스팀에 대한 효용성 평가)

  • Jung, Hee Won;Kim, Jeong Mee;Min, Myung Sook;Lee, Young Mee;Bang, Joon Seok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.25 no.3
    • /
    • pp.151-158
    • /
    • 2015
  • Objective: This study was designed to compare pegfilgrastim and filgrastim in diffuse large B-cell lymphoma (DLBCL) patients treated with a rituximab with cyclophosphamide, hydroxydaunorubicin, oncovin, and prednisone (R-CHOP) regimen in terms of clinical efficacy and cost-effectiveness. Method: Clinical efficacy was measured by trough level of absolute neutrophil count (ANC), days of ANC under 50% of baseline value, days of ANC under 90% of baseline value, duration of ANC recovery to baseline value, days of ANC less than $0.5{\times}10^9cells/L$, and difference of peak and trough level of ANC during 1 cycle of R-CHOP regimen. To evaluate cost-effectiveness, total prices of used filgrastim and pegfilgrastim within 1 cycle of R-CHOP were analyzed. Results: In terms of clinical efficacy, trough level of ANC and days to ANC recovery showed statistical significance. The median trough levels of ANC with administration of filgrastim and pegfilgrastim were 0.18 and 1.94 (p = 0.021), respectively, and the median durations of ANC recovery to baseline value were 5.5 days and 2 days (p = 0.023), respectively. For the median days of ANC under 50% of baseline value, days of ANC under 90% of baseline value, days of ANC less than $0.5{\times}10^9cells/L$, and difference of peak and trough level of ANC during 1 cycle of R-CHOP, the pegfilgrastim group performed better than the filgrastim group. However the difference was not statistically significant. In terms of overall expense during 1 cycle of R-CHOP, pegfilgrastim is about 3.43 times more expensive than filgrastim. Conclusion: Pegfilgrastim is more efficient than filgrastim in terms of clinical efficacy. In terms of prices, pegfilgrastim is more expensive than filgrastim for patients, but it is more convenient in clinical use. Therefore, pegfilgrastim should be the preferred choice of G-CSF for neutropenic patients. Further comparative study of pegfilgrastim and filgrastim is needed.

Ca-release Channel of the Sarcoplasmic Reticulum of the Snake (Reptile) Skeletal Muscle (뱀 (파충류) 골격근 소포체 칼슘유리 채널)

  • Nam, Jang-Hyeon;Seok, Jeong-Ho
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.1
    • /
    • pp.57-66
    • /
    • 1996
  • To investigate properties of Ca-release channel in the reptile skeletal muscle, electrophoretical analysis, purification of RyR, $[^3H]ryanodine$binding study, and $^{45}Ca-release$ were carried out in the SR vesicles prepared from the snake skeletal muscle. The snake SR vesicle has the single high molecular weight protein band on SDS-PAGE, and its mobility was similar with that of rat skeletal SR vesicles. The high molecular weight band on SDS-PACE was found in the $[^3H]ryanodine$ peak fractions $(Fr_{5-7})$ obtained from the purification step of the RyR. Maximal binding site and Kd of the snake SR RyR were 6.36 pmole/mg protein and 17.62 nM, respectively. Specific binding of $[^3H]ryanodine$ was significantly increased by calcium and AMP (P<0.05), but not or slightly inhibited by tetracaine, ruthenium red (5.4%), or $MgCl_2$ (21%). $^{45}Ca-release$ from the SR vesicles loaded passively was significantly increased by the low concentration of calcium $(1{\sim}10{\mu}M)$ and AMP (5 mM)(P<0.05), but significantly decreased by the high concentration $(300{\mu}M)$ of calcium, tetracaine (1 mM), ruthenium red $(10{\mu}M)$, and $MgCl_2$ (2 mM)(P <0.05). From the above results, it is suggested that snake SR vesicles also have the RyR showing the similar properties to those of mammalian skeletal RyR with the exceptions of no or slight inhibition of $[^3H]ryanodine-binding$ by tetracaine, ruthenium red, or $MgCl_2$.

  • PDF

The Effects of Tidal Volume on Minimal Occlusion Pressure of Endotracheal Tube Cuff in Patients with Same Peak Inspiratory pressure (동일한 최고 흡기압(Peak inspiratory pressure)에서 기관 내관 풍선(Endotracheal tube cuff)의 최소 밀폐압(Minimal occlusion pressure)에 대한 상시량의 영향)

  • Sohn, Jang Won;Kim, Tae Hyung;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.5
    • /
    • pp.434-438
    • /
    • 2004
  • Background : An excessive endotracheal cuff pressure can cause tracheal injury, and insufficient cuff pressure may not generate an effective cuff seal. The peak inspiratory pressure influences the minimal occlusion pressure of the endotracheal tube cuff. However, the relationship between the minimal occlusion pressure and the tidal volume has not been investigated. This study was conducted to estimate the relationship between the tidal volume and the minimal occlusion pressure of the cuff. Methods : Ten mechanically ventilated patients were included. The minimal occlusion pressure of the cuff was measured using a pressure gauge. The basal tidal volume was increased and decreased as much as 10% whilst maintaining the same peak inspiratory pressure. The, minimal occlusion pressures were then measured in the high and low tidal volume state, respectively. Results : The peak inspiratory pressure was $32.6{\pm}4.72cmH_2O$ and the minimal occlusion pressure was $19.0{\pm}2.26$ mmHg in the basal ventilator setting. There was a significant relationship between the peak inspiratory pressure and the minimal occlusion pressure(r=0.77, p<0.01). The minimal occlusion pressure of the cuff was increased to $20.3{\pm}2.4$ mmHg in the high tidal volume state(p<0.05), and decreased to $16.8{\pm}3.01$ mmHg in the low tidal volume state (p<0.001). Conclusion : The minimal occlusion pressure of the cuff can be influenced by changes in the tidal volume as well as by the peak inspiratory pressure.

Novel Rate Control Scheme for Low Delay Video Coding of HEVC

  • Wu, Wei;Liu, Jiong;Feng, Lei
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.185-194
    • /
    • 2016
  • In this paper, a novel rate control scheme for low delay video coding of High Efficiency Video Coding (HEVC) is proposed. The proposed scheme is developed by considering a new temporal prediction structure of HEVC. In the proposed scheme, the relationship between bit rate and quantization step is exploited firstly to formulate an accurate quadratic rate-quantization (R-Q) model. Secondly, a method of determining the quantization parameters (QPs) for the first frames within a group of pictures is proposed. Thirdly, an accurate frame-level bit allocation method is proposed for HEVC. Finally, based on the proposed R-Q model and the target bit allocated for the frame, the QPs are predicted for coding tree units by using rate-distortion (R-D) optimization. We compare our scheme against that of three other state-of-the-art rate control schemes. Experimental results show that the proposed rate control scheme can increase the Bjøntegaard delta peak signal-to-noise ratio by 0.65 dB and 0.09 dB on average compared with the JCTVC-I0094 and JCTVC-M0036 schemes, respectively, both of which have been implemented in an HEVC test model encoder; furthermore, the proposed scheme achieves a similar R-D performance to Wang's scheme, as well as obtaining the smallest bit rate mismatch error of all the schemes.

A Mixture of Curcumin, Vitamin C, and E Prolongs the Antioxidant Effect to Beyond That of Each Component Alone in Vivo

  • Jeon, Hee-Young;Kim, Jeong-Kee;Lee, Ji-Eun;Shin, Hyun-Jung;Lee, Sang-Jun
    • Food Science and Biotechnology
    • /
    • v.17 no.6
    • /
    • pp.1151-1155
    • /
    • 2008
  • This study aimed to investigate the alterations in plasma antioxidant activity after the consumption of a single oral dose of curcumin, vitamin C, and E administered individually or in combination to (i) assess possible synergies or antagonism between the antioxidants and (ii) determine the optimal composition of the antioxidant mixture such that the duration of action is prolonged to beyond that of individual antioxidants. Each antioxidant was administered to male Sprague-Dawley rats, and blood samples were drawn at different time points up to 180 min to measure the plasma total antioxidant capacity (TAC). Five antioxidant compositions (M1-M5) were evaluated to assess the possible synergies or antagonisms among them and to determine the optimal composition of the antioxidant mixture. Blood samples were collected up to 360 min post-consumption. A single oral dose of individual antioxidants significantly increased the TAC values; however, the time to reach the peak TAC value varied. Among the 5 antioxidant compositions, M2 exhibited the highest and most prolonged antioxidant effect in plasma; this was greater than the proportional sum of the effects of the individual antioxidants in the composition. This result indicates a synergistic interaction among antioxidants in the optimal composition M2.