• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.033 seconds

Collection of Adult and Larval Mosquitoes in U.S. Army Compounds in the Republic of Korea During 1979~1983 (한국에 주둔한 미군지역내에서의 모기 성충과 유충 채집(1979~1983))

  • ;R.K
    • Parasites, Hosts and Diseases
    • /
    • v.22 no.1
    • /
    • pp.102-108
    • /
    • 1984
  • This paper is the result of adult female mosquito and larval collection in U.S. Army Installations in Korea from 1979 to 1983. New Jersey light traps were operated for adult collection from May to October. The primary concern of this surveillance is to determine when to recommend insecticide spraying for mosquito control in the Army areas. The 5th Preventive Medicine Unit have developed an "index" level of female mosquitoes in a light trap similar to other U.S. Army Agencies in other parts of the world. When 10 female mosquitoes are reached on two consecutive trap-night, or 5 known vector females are collected, fogging is recommended in the trap areas. 1. Mosquito collections were conducted in 12 U.S. Army areas by operating 39 New Jersey light traps. Mosquitoes collected from the areas were identified to be 17 species comprising 3 genera. Anopheles sinensis (40%), Culex tritaeniorhynchus (31%), Aedes vexans nipponii (19 %) and Culex pipiens pallens (10%) appeared to be the most common species in the areas. 2. The species, population density and monthly appearance of adult mosquitoes were found to be almost the same in the all provinces involved. And Japanese Encephalitis vector mosquitoes, Culex tritaeniorhynchus, showed their seasonal fluctuation from July to September with a peak in August each year. 3. Larval habitats confirmed in the Army areas were categorized into 16 types as shown in Table 3. The mosquito larvae collected in those habitats were identified to be 15 species representing 4 genera. Most breeding sites in the Army areas were those which are activated during the wet season. 4. More mosquitoes were collected from the Kyungki Province than from the other Provinces. The reason for more collection of mosquitoes from military installations in the Kyungki Province appears to be the geographic characteristics surrounded by rice fields, marshes and other stagnant water areas.

  • PDF

The Agreements between FEV1 and PEFR in the Patients of Mild Bronchial Asthma (외래 진료가 가능한 경증 천식 환자에서 1초간 노력성 호기량(FEV1)과 최대 호기유속(PEFR)간의 연관성)

  • Chang, Won Chul;Kim, Byung Kook;Kim, Soon Jong;Yoo, Kwang Ha;Lee, Tae-Hun;Lee, Jung Yeon;Lee, Kye Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.638-643
    • /
    • 2005
  • Background : Several studies have shown considerable disagreement when using the $FEV_1$ and PEFR to assess the severity of an airflow obstruction. A differential classification of the severity of asthma would lead to serious differences in the evaluation and management of asthma. The aim of this study was to examine the relationship between the $FEV_1$ and PEFR in asthma patients with mild symptoms. Methods : In this study, the PEFR and $FEV_1$ were obtained from 92 adult asthma patients with mild symptoms attending an outpatient pulmonary clinic. The mean differences and the limits of agreement in the paired measurements of the $FEV_1$ and PEFR were calculated. Results : There was a considerable correlation between the $FEV_1$ and PEFR measurements when expressed as a % of the predicted values (r=0.686, p<0.01). The 95% limit of agreement (mean difference ${\pm}1.96SD$) between the $FEV_1$ % and PEFR % were acceptable(-27.4%~33.8%). In addition, the weighted ${\kappa}$(kappa) coefficient for the agreement between the $FEV_1$ % and PEFR % was 0.74 (95% CI, 0.63-0.81), indicating excellent agreement between the two measurements. Conclusion : The spirometer ($FEV_1$) and the Mini-Wright peak flow meter (PEFR) can be used interchangeably in adult asthma patients with mild symptom.

The Clinical Study of the Lower Respiratory Tract Infection by Respiratory Syncytial Virus on Children under 2 Year of Age (2세 이하 어린이에서 Respiratory Syncytial Virus에 의한 하기도 감염에 관한 연구)

  • Cho, Jung Ik;Choi, Hyung Chul;Kim, Jong Duck;Cho, Ji Hyun
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.2
    • /
    • pp.193-200
    • /
    • 2000
  • Purpose : This study was designed and performed for evaluations of clinical manifestation and course of the children under 2 year of age with respiratory tract infection and positive respiratory syncytial virus(RSV) antigen. Methods : The selection criteria of the patients were children under 24 month-of-age, Clinical manifestation of respiratory tract infection, and positive RSV antigen that was detected by Vitek ImmunoDiagnostic Assay System(VIDAS) from nasal cavity. The additional laboratory and simple chest X-ray findings were reviewed from the chart of children who were admitted Wonkwang university hospital from October 1999 to March 2000. Results : Total number of patients enrolled on this study was 102. The 48(47%) children were RSV antigen positive by VIDAS method. Abnormal chest X-ray findings were noticed in 38 cases. The male to female sex ratio of 48 RSV antigen positive cases was 1.2 : 1. The mean and range of age was $10.2{\pm}5.9$ and 1.0~24 months. The peak outbreak of cases was noticed on November, 1999. All of the cases shows coughing but rale was audible in 30 cases(60%). Dyspnea, wheezing, and intercostal retraction were noticed 11(23%), 15(31%), and 10(21%) cases respectively. The most common chest X-ray finding was scattered patch infiltration that was noticed in 30 cases(63%). The mean total white blood cell counts in peripheral blood was $12,608{\pm}4,686/mm^3$. The mean blood level of IgA and IgE were $50.8{\pm}20.9$ and $72.1{\pm}98.3mg/dL$ respectively. The C-reactive protein was $16.0{\pm}18.5mg/L$. Total 5 cases need a mechanical respiraton. The duration of admission was under 7 days in 36 cases(75%). Conclusion : The RSV antigen was detected commonly in late fall and winter season. The severity of children under 2 years old with RSV respiratory tract infection take in some degree a gave courses.

  • PDF

Correlation between Glycemic Index and in vitro Starch Hydrolysis of Cereals (곡류의 혈당지수와 전분 가수분해율과의 상관관계)

  • Lee, Jung-Sun;Shin, Hyun-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.1229-1235
    • /
    • 1998
  • To see the correlation between the rate of in vitro starch hydrolysis and the glycemic index, an in vitro digestion was carried out by incubating the cereal samples for 2 hours with ${\alpha}-amylase$ in dialysis tubing. Also the levels of blood glucose were measured over 2 hours after feeding healthy volunteers with 50 g carbohydrate portions. Hydrolysis area, hydrolysis index (HI) and the dialysate content of carbohydrate throughout the digestion time for barley was significantly below those for other cereals (p<0.05), and unpolished glutinous rice was significantly above (p<0.05). The GI-glucose of barley $(57%{\pm}7)$ to glucose as standard was significantly (p<0.05) lower than those of other cereals whereas the GI-glucose of glutinous rice $(110%{\pm}8)$ was significantly higher (p<0.05) than other cereals. The GI-rice values to rice as standard were $122%{\pm}4$ for glutinous sorghum, $116%{\pm}13$ for job's tear, $115%{\pm}13$ for glutinous millet, $106%{\pm}6$ for unpolished glutinous rice, $102%{\pm}7$ for glutinous rice, $100%{\pm}0$ for rice, $90%{\pm}12$ for unpolished rice, $85%{\pm}6$ for foxtail millet, $79%{\pm}5$ for buckwheat and $63%{\pm}6$ for barley. The GI-rice was significantly correlated to hydrolysis area and HI (r=0.75, p<0.01). It suggests that the in vitro starch hydrolysis offers good potential to predict the in vivo glycemic response of starch foods.

  • PDF

Parametric Images of Standardized Uptake Values using P-18-FDG Attenuation Corrected Whole Body PET (F-18-FDG감쇠보정 전신 PET을 이용한 표준섭취계수 추정과 매개변수 영상의 구성)

  • Kim, Kyeong-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Yong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.560-569
    • /
    • 1996
  • Background and Purpose : Standardized uptake value(SUV) has been used as a quantitative index for differentiating benign and malignant tumors with F-18-FDG PET In this study, we produced whole body parametric images of SUV(WBPIS) by body weight normalization, and validated the values by comparison with SUV's calculated with regional scans. Subjects and Methods : Whole body scans were followed by regional scans sequentially on 23 patients. In whole body study, transmission and emission scans were acquired for 2 minutes and 6 minutes for each bed position, respectively. In regional study, transmission and emission scans were acquired for 20 minutes. Measured and segmented/ smoothed attenuation correction were applied using these 2 min transmission scans in whole body studies. The effects of attenuation correction on SUVs were evaluated quantitatively using F-18 filled cylindrical phantom. The mean and peak SUVs obtained from WBPIS were compared with SUVs of the regional scans. Results : In phantom studies, with any method of attenuation correction using regional or whole body studies of phantom, SUVs were nearly consistent. In whole body scan, SUV obtained using measured attenuation correction method was a little higher than SUV of regional scan. SUV obtained using segmented/smoothed attenuation correction method was a little lower. In patient studies, WBPIS using segmented/smoothed attenuation correction method was much smoother and more readable. SUVs of WBPIS obtained with both methods of attenuation correction were well correlated with SUVs of regional scans(r=0.9). SUVs of WBPIS with measured attenuation correction method were 5% lower than SUVs of regional scans. SUVs of WBPIS with segmented/smoothed attenuation correction method were 10% lower than SUVs of regional scans. The differences of SUVs of WBPIS by the two attenuation correction methods were relatively small compared with the possible differences derived from biological characteristics of tumors. Conclusion : We concluded that WBPIS could be useful in the quantification of tumor as well as in localization of whole body lesions, which were often outside the field of view in regional scan. WBPIS made using segmented/smoothed attenuation correction method could be used in clinical routines and SUVs from attenuation corrected F-18-FDG PET could be used interchangeably with SUVs of regional studies.

  • PDF

Impact of IODM and ENSO on the East Asian Monsoon: Simulations through NCAR Community Atmospheric Model (동아시아 몬순 지역에서 IODM과 ENSO의 영향 : NCAR Community Atmospheric Model을 이용한 모의 실험)

  • Oh J.-H.;Chaudhari H. S.;Kripalani R. H.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.4
    • /
    • pp.240-249
    • /
    • 2005
  • The normal Indian Ocean is characterized by warmer waters over the eastern region and cooler waters over the western region. Changes in sea surface temperature (SST) over the western and eastern Indian Ocean give birth to a phenomenon now referred to as the Indian Ocean Dipole Mode (IODM). The positive phase of this mode is characterized by positive SST anomalies over the western Indian Ocean and negative anomalies over the southeastern Indian Ocean, while the negative phase is characterized by a reversed SST anomaly pattern. On the other hand, the normal Pacific Ocean has warm (cool) waters over the western (eastern) parts. Positive (negative) SST anomalies over the central/eastern (western) Pacific Ocean characterize the E1 Nino phenomenon. The reverse situation leads to the La Nina phenomenon. The coupled ocean-atmosphere phenomenon over the Pacific is referred to as the E1 Nino Southern Oscillation (ENSO) phenomenon. In this study the impact of IODM and ENSO on the East Asian monsoon variability has been studied using observational data and using the Community Atmospheric Model (CAM) of the National Center for Atmospheric Research (NCAR). Five sets of model experiments were performed with anomalous SST patterns associated with IODM/ENSO superimposed on the climatological SSTs. The empirical and dynamic approaches reveal that it takes about 3-4 seasons fur the peak IODM mode to influence the summer monsoon activity over East Asia. On the other hand, the impact of ENSO on the East Asian monsoon could occur simultaneously. Further, the negative (positive) phase of IODM and E1 Nino (La Nina) over the Pacific enhances (suppresses) monsoon activity over the Korea-Japan Sector. Alternatively, IODM appears to have no significant impact on monsoon variability over China. However, El Nino (La Nina) suppresses (enhances) monsoon activity over China. While the IODM appears to influence the North Pacific subtropical high, ENSO appears to influence the Aleutian low over the northwest Pacific. Thus, the moisture supply towards East Asia from the Pacific is determined by the strengthening/weakening of the subtropical high and the Aleutian low.

Effect of Various Mixing Ratio of Non-glutinous and Glutinous Rice on Physical and Rheological Properties of Extrudate (멥쌀과 찹쌀의 혼합비율별 압출성형물의 물리적 성질 및 유동특성)

  • Kum, Jun-Seok;Kwon, Sang-Oh;Lee, Hyun-Yu;Lee, Sang-Hyo;Jung, Jin-Hyub;Kim, Jun-Pyong
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.442-447
    • /
    • 1994
  • Effect of different mixing ratio of non-glutinous and glutinous rice on physical and rheological properties of extrudate prepared in a single screw extruder were examined. The extrusion conditions in term of screw speeds, moisture content and die temperature were 258 rpm, 18% and $120^{\circ}C$, respectively. The resisdence time distribution of the most of materials were within 30 second and small portion of them went up to 80 second. The expansion ratio was the highest value (2.93) for 70% of glutinous rice in the mixture, while the lowest value for 100% of non-glutinous rice. Breaking strength was in the range between 1,051g and 1,117g for $10{\sim}20%$ of glutinous rice in the mixture, while the lowest value (737g) for 80%r of glutinous rice. As the amount of glutinous rice increased, L and a values were increased and b value was decreased. The uncooked cold paste viscosity had 400 B.U. for 100% non-glutinous rice , while no peak for the 100% glutinous rice. As the amount of glutinous rice increased up to 100%, the water absorption index (WAI) was decreased, while water solubility index (WSI) was increased. The rheological properties of extrudate were accounted by the law of Oswald. The flow behavior index of extrudate was less than 1.0, which showed pseudoplastic behavior. Yield stress was the highest value for 20% of glutinous rice in the mixture and the lowest value for $80{\sim}100%$ of glutinous; rice. Number of air cell was between 128 and 159 for $80{\sim}100%$ of glutinous rice in the mixture, while $81{\sim}84%$ for $0{\sim}20%$ of glutinous rice. The degree of shapefact was increased more when the mixtures of glutinous and non-glutinous rice was used than when glutinous or non-glutinous rice was only used.

  • PDF

Effects of 1 keV $Ar^+$ ion irradiation on Au films on glass (1 keV $Ar^+$ 이온의 조사가 유리기판위의 금 박막의 미치는 영향)

  • Jang, H. G.;Kim, H. S.;Han, S.;Choi, W. K.;Koh, S. K.;Jung, H. J.
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.371-376
    • /
    • 1996
  • Au films with a thickness around 1600 $\AA$ were deposited onto glass at room temperature by ion beam sputtering with a 5 cm cold-hollow ion gun at pressure $1\times 10^{-6}-1\times 10^{-5}$ Torr. Irradiation of the Au deposited samples was carried out at pressure of $7\times 10^{-6}$ Torr. For the sputter depositions, $Ar^+$ ion energy was 1 keV, and the current density at the substrate surface was 15 $\mu$A/$\textrm{cm}^2$. Effects of 1 keV $Ar^+$ ion dose($I_d$) between $1\times 10^{16}\; and\;2\times 10^{17}\;Ar^+\textrm{cm}^{-2}$on properties such as crystallinity, surface roughness and adhesion, etc. of the films have been investigated. The Au films sputtered by $Ar^+$ ion beam had only (111) plane and the X-ray intensity of the films decreased with increase of $I_d$. The thickness of Au films reduced with Id. $R_{ms}$ surface roughness of the films increased from 16 $\AA$ at as-deposited to 1118 $\AA$ at ion dose= $2\times 10^{17}\;Ar^+\textrm{cm}^{-2}$. Adhesion of Au film on sputtered at $I_d$= $2\times 10^{17}\;Ar^+\textrm{cm}^{-2}$ was 9 times greater than that of Au film with untreated, as determined by a scratch test.

  • PDF

Change of Serum Levels of C-Reactive Protein After Coronary Angioplasty and Its Effects on Clinical Restenosis (협심증 환자에서 관동맥중재술에 따른 C-reactive Protein의 변화 및 임상경과)

  • Park, Jong-Seon;Hong, Gu-Ru;Lee, Chae-Hoon;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.215-225
    • /
    • 2001
  • Background: There are many evidences that inflammation is an important determinant of the development of atherosclerosis and one of the systemic markers of inflammation, C-reactive protein(CRP), is associated with extent of coronary artery disease and risk of coronary events. We assessed the time response of CRP response after coronary angioplasty and it's influence on the clinical restenosis in angina patients. Materials and Methods: Patients included 36 angina patients undergoing single vessel angioplasty. Levels of CRP were measured before and 12, 24, 48, and 72 hours after angioplasty. Clinical restenosis was assessed at 6 months after procedure. Results: Baseline CRP level was $0.30{\pm}0.01$ mg/dL in stable and $0.46{\pm}0.28$ mg/dL in unstable angina patients(p<0.05). After angioplasty, CRP level was increased with peak at 24 hour and persisted to 72 hours after angioplasty. At 24 hour after angioplasty, the magnitude of CRP change was $0.32{\pm}0.31$ mg/dL in stable and $0.79{\pm}0.73$ mg/dL in unstable angina patient(p<0.05). The change of CRP level was not associated with troponin-T after angioplasty. In unstable angina patients, clinical restenosis was developed in 8% of patients with low baseline CRP levels and in 50% of those with high baseline CRP levels more than 0.6 mg/dL(p<0.05). Conclusion: In unstable angina patients, inflammatory response is more increased than stable angina patients, and increased inflammatory response effects on the restenosis after coronary angioplasty.

  • PDF

Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams (에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.65-71
    • /
    • 1998
  • The aims are to evaluate the effects of an 1.0 cm acrylic plate and SSD on the dose profile and depth dose distribution of 9 MeV electron beam and to analyse adequacy for using an acrylic plate to reduce energy of electron beams. An acrylic plate of 1.0 cm thickness was used to reduce energy of 9 MeV electron beam to 7 MeV. The plate was put on an electron applicator at 65.4 cm distance from x-ray target. The size of the applicator was 10${\times}$l0cm at 100 cm SSD. For 100cm, l05cm and 110cm SSD, depth dose on beam axis and dose profiles at d$\_$max/ on two principal axes were measured using a 3D water phantom. From depth dose distributions, d$\_$max/, d$\_$85/, d$\_$50/ and R$\_$p/, surface dose, and mean energy and peak energy at surface were compared. From dose profiles flatness, penumbra width and actual field size were compared. For comparison, 9 MeV electron beams were measured. Surface dose of 7 MeV electron beams was changed from 85.5% to 82.2% increasing SSD from 100 cm to 110 cm, and except for dose buildup region, depth dose distributions were independent of SSD. Flatness of 7 MeV ranged from 4.7% to 10.4% increasing SSD, comparing 1.4% to 3.5% for 9 MeV. Penumbra width of 7 MeV ranged from 1.52 cm to 3.03 cm, comparing 1.14 cm to 1.63 cm for 9 MeV. Actual field size increased from 10.75 cm to 12.85 cm with SSD, comparing 10.32 cm to 11.46 cm for 9 MeV. Virtual SSD's of 7 and 9 MeV were respectively 49.8 cm and 88.5cm. In using energy reducer in electron therapy, depth dose distribution were independent of SSD except for buildup region as well as open field. In case of using energy reducer, increasing SSD made flatness to deteriorate more severely, penumbra width more wide, field size to increase more rapidly and virtual SSD more short comparing with original electron beam. In conclusion, it is desirable to use no energy reducer for electron beam, especially for long SSD.

  • PDF