• Title/Summary/Keyword: R-Peak

Search Result 1,514, Processing Time 0.03 seconds

Peak Expiratory Flow(PEF) Measured by Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters in Healthy Children (정상 소아에서 최고호기유량계(peak flow meter)로 측정한 최고호기유량(PEF)와 기타 환기기능검사와의 상관관계)

  • Oak, Chul-Ho;Sohn, Kai-Hag;Park, Ki-Ryong;Cho, Hyun-Myung;Jang, Tae-Won;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.3
    • /
    • pp.248-259
    • /
    • 2001
  • Background : In diagnosis or monitor of the airway obstruction in bronchial asthma, the measurement of $FEV_1$ in the standard method because of its reproducibility and accuracy. But the measurement of peak expiratory flow(PEF) by peak flow meter is much simpler and easier than that of $FEV_1$ especially in children. Yet there have been still no data of the predicted normal values of PEF measured by peak flow meter in Korean children. This study was conducted to provide equations to predict the normal value of PEF and correlation between PEF and $FEV_1$ in healthy children. Method : PEF was measured by MiniWright peak flow meter, and the forced expiratory volume and the maximum expiratory flow volume curves were measured by Microspiro HI 501(Chest Co.) in 346 healthy children(age:5-16 years, 194 boys and 152 girls) without any respiratory symptoms during 2 weeks before the study. The regression equations for various ventilatory parameters according to age and/or height, and the regression equations of $FEV_1$ by PEF were derived. Results : 1. The regression equation for PEF(L/min) was: $12.6{\times}$age(year)+$3.4{\times}$height(cm)-263($R^2=0.85$) in boys, and $6{\times}$age(year)+$3.9{\times}$height(cm)-293($R^2=0.82$) in girls. 2. The value of FEFmax(L/sec) derived from the maximum expiratory flow volume curves was multiplied by 60 to compare with PEF(L/min), and PEF was faster by 125 L/min in boys and 118 L/min in girls, respectively. 3. The regression equation for $FEV_1$(ml) by PEF(L/min) was:$7{\times}$PEF-550($R^2=0.82$) in boys, and $5.8{\times}$PEF-146 ($R^2=0.81$) in girls, respectively. Conclusion : This study provides regression equations predicting the normal values of PEF by age and/or height in children. And the equations for $FEV_1$, a gold standard of ventilatory function, was predicted by PEF. So, in taking care of children with airway obstruction, PEF measured by the peak flow meter can provide useful information.

  • PDF

Comparison of Different Mathematical Models for Describing the Complete Lactation of Akkaraman Ewes in Turkey

  • Keskin, Ismail;Dag, Birol
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.11
    • /
    • pp.1551-1555
    • /
    • 2006
  • This study was carried out to investigate the use of three different mathematical models (Wood, Quadratic and Cubic) for describing the lactation curve of Akkaraman ewes. Data were collected from 42 ewes that were three years of age and from the same flock raised in The State Farm of $G{\ddot{o}}zl{\ddot{u}}$ in Konya Province. All ewes lambed in March. They were hand milked twice daily and the first milk test was performed with in the first month after lambing (mean = 27.8 day, SD = 4.26) in an attempt to describe the peak yield. The differences between estimated total milk yields by the models were not significant. The models were adequate for describing total milk yield. The differences between peak yields were not significant. The Wood model estimated the time of peak yield earlier than the other models and observed values (p<0.01). Especially the Cubic model's peak time was very close to really peak time (34.30 vs. 35.33 days). $R^2$ values of the models ranged from 85.85% to 96.20%. The Cubic model gave the best $R^2$ value (p<0.01). Correlation coefficients between descriptive values of the models changed from 0.32 to 1.00. Total milk yields of the models were highly correlated (above 0.99) with the total milk yield calculated by the Fleischmann method (p<0.01). As a result the Cubic model showed the best fit to the data collected from Akkaraman ewes and allowed a suitable description of the shape of the lactation curve.

The Incidence, Associated Factors and Clinical Impact of Hyperamylasemia in Self-poisoning Patients (중독 환자에서 고아밀라아제혈증의 발생률, 관련 요인 및 임상적 영향)

  • Seo, Min Gu;Oh, Sang Hoon;Lim, Jee Yong;Kim, Han Joon;Choi, Se Min
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.14 no.2
    • /
    • pp.83-91
    • /
    • 2016
  • Purpose: This study was conducted to investigate the incidence, associated factors and clinical impact of hyperamylasemia in self-poisoning patients. Methods: This study was based on a toxicology case registry of patients treated from 2009 to 2013 at a tertiary care university hospital. We retrospectively investigated the demographics, clinical variables, laboratory variables and intoxicants. Hyperamylasemia was defined as an elevation in serum amylase level to above the upper normal limit within 24 hours after admission. We analyzed the predisposing factors and clinical outcomes of patients in the hyperamylasemia group. Results: Hyperamylasemia was identified in 49 (13.3%) of the 369 patients. Using multivariate logistic regression, the odds ratios for HA were 3.384 (95% confidence interval, 1.142-8.013, p=0.014), 3.261 (95% confidence interval, 1.163-9.143, p=0.025) and 0.351 (95% confidence interval, 0.154-0.802, p=0.013) for pesticides, multi-drug use and sedatives, respectively. In the hyperamylasemia group, the peak amylase levels during 72 hours were correlated with the peak lipase levels (r=0.469, p=0.002) and peak aspartate aminotransferase levels (r=0.352, p=0.013). Finally, none of these patients had confirmed acute pancreatitis. Conclusion: Hyperamylasemia occurred rarely in these self-poisoning patients, and pesticide and multi-drug use were independent predictors of hyperamylasemia. Peak amylase levels were correlated with the peak lipase and aspartate aminotransferase levels.

Different Biomechanical Characteristics in Proprioception, Muscle Strength, and Time to Peak Torque at Velocity of 300°/sec of the Ankle Joint in People With or Without Functional Ankle Instability (각속도 300°/sec에서 기능적 발목불안 유무에 따른 고유수용성감각, 발목 근력, 그리고 최고 회전력까지 걸리는 시간의 생체역학적 특성 차이)

  • Park, Eun-Young;Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.45-53
    • /
    • 2013
  • The purpose of this study was to examine the differentiation of proprioception, invertor and evertor muscle strength, and time to peak torque at a velocity of $300^{\circ}/sec$ of the ankle joint in people with or without functional ankle instability (FAI). Nineteen subjects with a history of ankle sprain participated. All subjects were divided into FAI group ($n_1=9$, Cumberland ankle instability tool (CAIT)${\leq}24$) and a control group ($n_2=10$) based on their CAIT scores. Isokinetic dynamometer was used to measure the sense of active joint position of the ankle at mid-range and end-range of an inversion motion and invertor as well as the evertor muscle strength and time to peak torque at $300^{\circ}/s$. The FAI group showed a statistically reduction in invertor and evertor muscle strength and time to peak torque when compared to the control group (p<.05). Muscle strength and time to peak torque of the invertor and evertor, as well as the sense of active joint position at end-range were also lower in the FAI group than in the control (p<.05). Correlations between CAIT score and position sense at end-range (r=-.577) and invertor muscle strength (r=.554) were statistically significant (p<.05). Individuals with FAI showed reduction in invertor and evertor muscle strength and recruitment time as well as in proprioception of the ankle joint. Thus, proprioception and invertor and evertor muscle strength of the ankle joint at fast angular velocity may be investigated when examining and planning care for individuals with FAI.

The Evaluation of Degradation Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring (누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가)

  • Kim, Jeong-Ho;Song, Woo-Chang;Cho, Han-Goo;Park, Yong-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.60-64
    • /
    • 2001
  • The degradation process of silicone rubber was investigated by leakage current monitoring in Inclined-Plane method. DAS (Data Acquisition System) with 12-bit, 8-channel A/D converter was prepared. Average current, cumulative charge, current waveform and the number of peak pulses were measured on-line. And, FFT (Fast Fourier Transform) analysis was performed with stored current waveform. Besides, maximum erosion depth was measured in order to use as the indicator of the degradation process. So, the results of leakage current components and maximum erosion depth measurements were compared to find one or more components which have trends of changing similarly to that of erosion process. The result suggests that the ratio of peak current to r.m.s. current, harmonic contents and the number of peak pulses are well corresponding with the degradation process.

  • PDF

Studies on Starting Transient in Solid Rockets

  • V.R. Sanal Kumar;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.6-10
    • /
    • 2003
  • Accurate description of starting transient history allows and justifies the use of small margin of safety for the engine parts, resulting in high motor mass ratio in addition to satisfying the control and guidance requirements of the vehicle. Studies have been carried out for the prediction and reduction of ignition peak and pressure-rise rate during the starting transient of solid rocket motors. Numerical studies have been carried out using a two dimensional Navier-Stokes solver. It has been inferred through the parametric studies that, in the case of solid rocket motors with uniform port, high ignition peak is observed at high spread rate and low pressure-rise rate. In the case of the port with sudden expansion configuration, high ignition peak is observed at relatively high average spread rate and high-pressure rise rate. These studies are expected to aid the designer in reducing the ignition peak by altering the propellant properties or igniter characteristics without sacrificing the motor performance.

  • PDF

Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method (전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선)

  • Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

Effects of Rain Garden on Reduction of Subsurface Runoff and Peak Flow (레인가든이 지하유출 및 첨두유량 감소에 미치는 효과)

  • Kim, Changsoo;Sung, Kijune
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.5
    • /
    • pp.69-79
    • /
    • 2011
  • This study assessed the subsurface runoff and peak flow reduction in rain gardens. The results showed that the highest water retention was found in rain garden mesocosms in which Rhododendron lateritium and Zoysia japonica were planted, followed by mesocosms in which either R. lateritium or Z. japonica was planted, and the lowest water retention rate was found in non-vegetated control treatment mesocosms(${\alpha}$ < 0.05). Although higher rainfall intensity caused a decrease of peak flow reduction in both vegetated and non-vegetated treatments, peak flow reduction was the greatest in mesocosms with mixed plants. A rain garden can be an effective tool for environment-friendly stormwater management and improving ecological functions in urban areas. Depending on the purpose such as delaying runoff or increasing infiltration, various plant types should be considered for rain garden designing.

Large Solvent and Noise Peak Suppression by Combined SVD-Harr Wavelet Transform

  • Kim, Dae-Sung;Kim, Dai-Gyoung;Lee, Yong-Woo;Won, Ho-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.971-974
    • /
    • 2003
  • By utilizing singular value decomposition (SVD) and shift averaged Harr wavelet transform (WT) with a set of Daubechies wavelet coefficients (1/2, -1/2), a method that can simultaneously eliminate an unwanted large solvent peak and noise peaks from NMR data has been developed. Noise elimination was accomplished by shift-averaging the time domain NMR data after a large solvent peak was suppressed by SVD. The algorithms took advantage of the WT, giving excellent results for the noise elimination in the Gaussian type NMR spectral lines of NMR data pretreated with SVD, providing superb results in the adjustment of phase and magnitude of the spectrum. SVD and shift averaged Haar wavelet methods were quantitatively evaluated in terms of threshold values and signal to noise (S/N) ratio values.

Implementation for Gated Peak Detector of CSAM based on One Chip Processor (원 칩 프로세서 기반의 CSAM 의 게이트 피크 검출 구현)

  • Lar, Ki Kong;Ryu, Conan K.R.;Hur, Chang-Wu;Sun, Mingui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.776-779
    • /
    • 2010
  • Implementation for Gated Peak Detector CSAM (C Scanning Acoustic Microscope) based on One Chip processor is proposed in this paper. GDP (Gated Peak Detector) is implemented with VHDL tool. The proposed method leads to be available for its application and integration in all systems as well as acoustic microscope and the method is compared with the conventional methods. The technique results in efficiency in size and application.

  • PDF