• Title/Summary/Keyword: R-113

Search Result 729, Processing Time 0.031 seconds

Determination of Si/Al Ratio of Faujasite-type Zeolite by Single-crystal X-ray Diffraction Technique. Single-crystal Structures of Fully Tl+- and Partially K+-exchanged Zeolites Y (FAU), |Tl71|[Si121Al71O384]-FAU and |K53Na18|[Si121Al71O384]-FAU

  • Seo, Sung-Man;Lee, Oh-Seuk;Kim, Hu-Sik;Bae, Dong-Han;Chun, Ik-Jo;Lim, Woo-Taik
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1675-1682
    • /
    • 2007
  • Large colorless single crystals of faujasite-type zeolite with diameters up to 200 μm have been synthesized from gels with the composition of 3.58SiO2:2.08NaAlO2:7.59NaOH:455H2O:5.06TEA:1.23TCl. Two of these, colorless octahedron about 200 μm in cross-section have been treated with aqueous 0.1 M TlC2H3O2 and KNO3 in order to prepare Tl+- and K+-exchanged faujasite-type zeolites, respectively, and then determined the Si/Al ratio of the zeolite framework. The crystal structures of |Tl71|[Si121Al71O384]-FAU and |K53Na18|[Si121Al71O384]-FAU per unit cell, a = 24.9463(2) and 24.9211(16) A, respectively, dehydrated at 673 K and 1 × 10-6 Torr, have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd m at 294 K. The two single-crystal structures were refined using all intensities to the final error indices (using only the 905 and 429 reflections for which Fo > 4σ(Fo)) R1/R2 = 0.059/0.153 and 0.066/0.290, respectively. In the structure of fully Tl+-exchanged faujasite-type zeolite, 71 Tl+ ions per unit cell are located at four different crystallographic sites. Twenty-nine Tl+ ions fill site I' in the sodalite cavities on 3-fold axes opposite double 6-rings (Tl-O = 2.631(12) A and O-Tl-O = 93.8(4)o). Another 31 Tl+ ions fill site II opposite single 6-rings in the supercage (Tl-O = 2.782(12) A and O-Tl-O = 87.9(4)o). About 3 Tl+ ions are found at site III in the supercage (Tl-O = 2.91(6) and 3.44(3) A), and the remaining 8 occupy another site III (Tl-O = 2.49(5) and 3.06(3) A). In the structure of partially K+-exchanged faujasite-type zeolite, 53 K+ ions per unit cell are found at five different crystallographic sites and 18 Na+ ions per unit cell are found at two different crystallographic sites. The 4 K+ ions are located at site I, the center of the hexagonal prism (K-O = 2.796(8) A and O-K-O = 89.0(3)o). The 10 K+ ions are found at site I' in the sodalite cavity (K-O = 2.570(19) A and O-KO = 99.4(9)o). Twenty-two K+ ions are found at site II in the supercage (K-O = 2.711(9) A and O-K-O = 94.7(3)o). The 5 K+ ions are found at site III deep in the supercage (K-O = 2.90(5) and 3.36(3) A), and 12 K+ ions are found at another site III' (K-O = 2.55(3) and 2.968(18) A). Twelve Na+ ions also lie at site I' (Na-O = 2.292(10) and O-Na-O = 117.5(5)o). The 6 Na+ ions are found at site II in the supercage (Na-O = 2.390(17) A and O-Na-O = 113.1(11)o). The Si/Al ratio of synthetic faujasite-type zeolite is 1.70 determined by the occupations of cations, 71, in two single-crystal structures.

Optimization of Microwave-Assisted Process for Extraction of Effective Components from Mosla dinthera M. (마이크로파 추출공정에 의한 쥐깨풀 유용성분의 추출조건 최적화)

  • Lee Eun-Jin;Kwon Young-Ju;Noh Jung-Eun;Lee Jeong-Eun;Lee Sung-Ho;Kim Jae-Keun;Kim Kwang-Soo;Choi Yong-Hee;Kwon Joong-Ho
    • Food Science and Preservation
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2005
  • Response surface methodology (RSM) was applied to microwave-assisted process (MAP) extraction for effective components from Mosla dianthera M. Microwave power (2,450 MHz, 0-160 W) and extraction time (1-5 min) were used as independent variables ($X_i$) for central composite design to yield 10 different extraction conditions. Optimum conditions were predicted for dependent variables of $75\%$ ethanol extracts, such as total yield($Y_1$), total phenolics($Y_2$), total flavonoids($Y_3$), and electron donation ability($Y_4$, EDA). Determination coefficients ($R^2$) of regression equations for dependent variables ranged from 0.8397 to 0.9801, and microwave power was observed to be more influential than extraction time in MAP. The maximal values of each dependent variable predicted at different extraction conditions of microwave power (W) and extraction time (min) were as follows; $6.76\%$ of total yield at 142.00 W and 4.36 min, 78.68 mg/g of total phenolics at 136.78 W and 4.40 min, 6.75 mg/g of total flavonoids at 159,69 W and 3.17 min, and $49.81\%$ of EDA at 133.87 W and 4.47 min, respectively. The superimposed contour maps for maximizing dependent variables illustrated the MAP conditions of 79 to 113 W in power and of 2.73 to 3.84 min in extraction time.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

The Clinical Experiences of "New Duromedics Valve" Replacement (새로운 Duromedics 인공판막 치환의 임상고찰)

  • Gang, Myeon-Sik;Yu, Gyeong-Jong;Yun, Chi-Sun;Park, Han-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.979-985
    • /
    • 1997
  • Between October 1991 and May 1995, 256 "New Duromedics Valve"(Edward TEKNA Bileaflet Valve) were implanted in 208 adult patients(171 mitral, 82 aortic and 3 tricuspid) with age ranging from 18 years to 70 years(mean 48.2$\pm$ 11.6 years). Postoperative complication rates were 12.2%, but there was none valve related one. Overall early mortality rate were 1.4%(1.6% for MVR, 2.1% for DVR, and none for AVR or TVR) respectively. Follow-up was 99% completed ranging in duration from 2 months to 46 months. There were 6 valve-related late complications(2.9%) with 2 patients with upper gastrointestinal bleeding, 2 with cerebral thxomtioembolism, 1 with valve thrombosis and 1 with valve endocarditis. Freedom from these valve-related major complications were 89.9% at 40 months. There were 5 late deaths(2.4%). one of these late deaths was considered valve-related. Overall actuarial survival rates at 40 months were 95.5%, 96.8% for mitral, 97.1% for aortic, 100% for tricuspid, and 92.0% for double valve replacement respectively. Preoperative New York Heart Association functional class were 2.9, and 1.3 in post-operative state. We have been trying to keep the international normalized ratio(INR) with range of 2.5 to 3.0. The INR of 4 patients of 5 with anticoagulant ralated complications was beyond the range. To reduce the rate of anticoagulant related complications, we felt very strongly that the INR should be kept between 2.5 and 3.0. In our cases, there was no structural failure or significant hemolysis in the absence of periprosthetic leak. This experience encourages us to continue using the "New Duromedics Valve".omedics Valve".uot;.

  • PDF

Discrimination of Geographical Origin for Astragalus Root (Astragalus membranaceus) by Capillary Electrophoresis and Near-Infrared Spectroscopy (Capillary electrophoresis 및 근적외선분광분석기를 이용한 황기의 원산지 판별)

  • Kim, Eun-Young;Kim, Jung-Hyun;Lee, Nam-Yun;Kim, Soo-Jeong;Rhyu, Mee-Ra
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.818-824
    • /
    • 2003
  • Capillary electrophoresis (CE) and near-infrared spectroscopy (NIRS) were performed to discriminate astragalus roots (Astragalus membranaceus) according to geographical origin (domestic or foreign). Two-hundred-and-four astragalus roots were extracted with 30% methanol in 0.1 M phosphate buffer (pH 2.5) and separated in a uncoated fused-silica $(50\;{\mu}m{\times}27\;cm)$ capillary. Conditions for optimal analysis included: temperature $-45^{\circ}C$, voltage -14 kV, and pressure injection time -8 sec. The optimal separation buffer was 0.1 M phosphate buffer (pH 2.5) containing 40 mM hexane sulfonic acid with 20% 2-methoxy ethanol. Raw NIR spectra were obtained using NIRS, and modified partial least square regression was used to develop the prediction model. The correlation coefficient and standard error of prediction were 0.915 and 14.3%, respectively. Under the optimal conditions established for CE and NIRS, the geographical origins of the astragalus roots were correctly identified in 80 and 97%, respectively. Astragalus roots that were not discriminated by NIRS were correctly discriminated by CE. Hence, CE and NIRS are potential methods for discriminating the geographical origins of astragalus roots that complement one another.

Prognostic Factors of Malignant Pleural Effusion in Non-small Cell Lung Cancer (비소세포폐암에 발생한 악성 흉수의 예후 인자)

  • Lim, Chang-Young;Lee, Gun;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.109-113
    • /
    • 2007
  • Background: In non-small cell lung cancer (NSCLC), malignant pleural effusion is a frequently observed com-plication, and is an important negative prognostic factor. Although many studies concerned to diagnosis and treatment of malignant pleural effusion have been performed, prognostic factors of malignant pleural effusion have rarely been investigated. This study was performed to determine the prognostic factors of malignant pleural effusion n non-small cell lung cancer. Material and Method: We evaluated 33 NSCLC patients with malignant effusion treated between January 2002 and December 2003. We analyzed possible factors: gender, age, TNM Stage, fluid analysis (pH, CEA, LDH, glucose, albumin) and treatment modality. Median survival time of each factor was calculated by Kaplan-Meier method and difference of median survival time between groups of factor compared by log-rank test. The Cox proportional hazards regression model was used to confirm the significance of prognostic factor. Results: Of the 33 patients, 23 (69.7%) patients were adenocarcinoma. The median interval of the diagnosis of lung cancer and malignant effusion was 7.3 months ($25^{th}{\sim}75^{th}:\;3.9{\sim}11.8$), and the median survival time was 3.6 months (95% Confidence Interval: $1.14{\sim}5.99$). In the univariate analysis, using the log-rank test, those with an adenocarcinoma showed a relatively longer median survival time than those of a non-adenocarcinoma (4.067 vs. 1.867 months, p=0.067) without statistical significance. In the multivariate analysis, using the Cox regression, those with a non-adenocarcinoma showed a trend of high risk of cancer death than those with an adenocarcinoma without statistical significance (Relative risk; 2.754, 95% Cl: $0.988{\sim}7.672$, p=0.053). Conclusion: We could not find an independent prognostic factor of malignant pleural effusion in NSCLC. As there was a trend of high risk of cancer death according to histology, further study will be needed.

Development of Analytical Method for Ergot Alkaloids in Foods Using Liquid Chromatoraphy-Tandem Mass Spectrometry (LC-MS/MS를 이용한 식품 중 맥각 알칼로이드 시험법 개발)

  • Chun, So Young;Chong, Euna;Lee, Bomnae;Kwon, Jin-Wook;Park, Hye Young;Kim, Sheenhee;Gang, Giljin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.158-169
    • /
    • 2019
  • Ergot alkaloids are mycotoxin produced by fungi of the Claviceps genus, mainly by Claviceps purpurea in EU. Recently obtained informations indicates necessity for control the ergot in imported grains. Recent occurrence data of ergot alkaloids from EU countries indicate the necessities of management and control these toxins from the imported grains like rye, wheat, oat etc. The aim of this study is to optimize the liquid chromatography-tandem mass spectrometry method for determination of ergot alkaloids (ergometrine, ergosine, ergotamine, ergocornine, ergocryptine, ergocristine and their epimers (-inines) from grain and grain-based food. The test method was optimized by extracting the sample with acetonitrile containing 2 mM ammonium carbonate, purification with Mycosep cartridge, and instrumental analysis by LC-MS/MS using Syncronis C18 column. The standard calibration curves showed linearity with correlation coefficents; $R^2$ >0.99. Mean recoveries ranged from 72.0 to 111.3% at three different fortified levels (20, 50, and $100{\mu}g/kg$). The correlation coefficient expressed as precision was within the range of 1.9-12.9%. The limit or quantifications (LOQ) ranged from 0.012 to $0.058{\mu}g/kg$. The developed analytical method met the criteria of AOAC Int. and CAC validation parameters like accuracy and sensitivity. As a result, it was confirmed that the test method developed in this study is suitable for the simultaneous analysis of six species of ergot alkaloid from grains and grain products.

Development and Validation of a Simultaneous Analytical Method for 5 Residual Pesticides in Agricultural Products using GC-MS/MS (GC-MS/MS를 이용한 농산물 중 잔류농약 5종 동시시험법 개발 및 검증)

  • Park, Eun-Ji;Kim, Nam Young;Shim, Jae-Han;Lee, Jung Mi;Jung, Yong Hyun;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.228-238
    • /
    • 2021
  • The aim of this research was to develop a rapid and easy multi-residue method for determining dimethipin, omethoate, dimethipin, chlorfenvinphos and azinphos-methyl in agricultural products (hulled rice, potato, soybean, mandarin and green pepper). Samples were prepared using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) and analyzed using gas chromatography-tandem mass spectrometry (GC-MS/MS). Residual pesticides were extracted with 1% acetic acid in acetonitrile followed by addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. The extracts were cleaned up using MgSO4, primary secondary amine (PSA) and octadecyl (C18). The linearity of the calibration curves, which waas excellent by matrix-matched standards, ranged from 0.005 mg/kg to 0.3 mg/kg and yielded the coefficients of determination (R2) ≥ 0.9934 for all analytes. Average recoveries spiked at three levels (0.01, 0.1, 0.5 mg/kg) and were in the range of 74.2-119.3%, while standard deviation values were less than 14.6%, which is below the Codex guideline (CODEX CAC/GL 40).

Analysis of Spatial Correlation between Surface Temperature and Absorbed Solar Radiation Using Drone - Focusing on Cool Roof Performance - (드론을 활용한 지표온도와 흡수일사 간 공간적 상관관계 분석 - 쿨루프 효과 분석을 중심으로 -)

  • Cho, Young-Il;Yoon, Donghyeon;Lee, Moung-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_2
    • /
    • pp.1607-1622
    • /
    • 2022
  • The purpose of this study is to determine the actual performance of cool roof in preventing absorbed solar radiation. The spatial correlation between surface temperature and absorbed solar radiation is the method by which the performance of a cool roof can be understood and evaluated. The research area of this study is the vicinity of Jangyu Mugye-dong, Gimhae-si, Gyeongsangnam-do, where an actual cool roof is applied. FLIR Vue Pro R thermal infrared sensor, Micasense Red-Edge multi-spectral sensor and DJI H20T visible spectral sensor was used for aerial photography, with attached to the drone DJI Matrice 300 RTK. To perform the spatial correlation analysis, thermal infrared orthomosaics, absorbed solar radiation distribution maps were constructed, and land cover features of roof were extracted based on the drone aerial photographs. The temporal scope of this research ranged over 9 points of time at intervals of about 1 hour and 30 minutes from 7:15 to 19:15 on July 27, 2021. The correlation coefficient values of 0.550 for the normal roof and 0.387 for the cool roof were obtained on a daily average basis. However, at 11:30 and 13:00, when the Solar altitude was high on the date of analysis, the difference in correlation coefficient values between the normal roof and the cool roof was 0.022, 0.024, showing similar correlations. In other time series, the values of the correlation coefficient of the normal roof are about 0.1 higher than that of the cool roof. This study assessed and evaluated the potential of an actual cool roof to prevent solar radiation heating a rooftop through correlation comparison with a normal roof, which serves as a control group, by using high-resolution drone images. The results of this research can be used as reference data when local governments or communities seek to adopt strategies to eliminate the phenomenon of urban heat islands.

Spatial Autocorrelation and the Turnout of the Early Voting and Regular Voting: Analysis of the 21st General Election at Dong in Seoul (공간적 자기상관성과 관내사전투표와 본투표의 투표율: 제21대 총선 서울시 동별 분석)

  • Lim, Sunghack
    • Korean Journal of Legislative Studies
    • /
    • v.26 no.2
    • /
    • pp.113-140
    • /
    • 2020
  • This study is meaningful in that it is the first analysis of Korean elections using the concept of spatial autocorrelation. Spatial autocorrelation means that an event occurring in one location in space has a high correlation with an event occurring in the surrounding area. The voter turnout rate in the 21st general election of Seoul area was divided into the early-voting turnout and voting-day turnout, and the spatial pattern of the turnout was examined. Most of the previous studies were based on the unit of the precinct and personal data, but this study analyzed on the basis of the lower unit, Eup-myeon-dong, and analyzed using spatial data and aggregate data. Moran I index showed a fairly high spatial autocorrelation of 0.261 in the voting-day turnout, while the index of the early-voting turnout was low at 0.095, indicating that there was little spatial autocorrelation despite statistical significance. The voting-day turnout, which showed strong spatial autocorrelation, was compared and analyzed using the OLS regression model and the spatial statistics model. In the general regression model, the coefficient of determination R2 rose from 0.585261 to 0.656631 in the spatial error model, showing an increase in explanatory power of about 7 percentage points. This means that the spatial statistical model has high explanatory power. The most interesting result is the relationship between the early-voting turnout and the voting-day turnout. The higher the early-voting turnout is, the lower the voting-day turnout is. When the early-voing turnout increases by about 2%, the voting-day turnout drops by about 1%. In this study, the variables affecting the early-voting turnout and the voting-day turnout are very different. This finding is different from the previous researches.