• 제목/요약/키워드: R/C shear wall

검색결과 38건 처리시간 0.023초

Effect of creep and shrinkage in a class of composite frame - shear wall systems

  • Sharma, R.K.;Maru, Savita;Nagpal, A.K.
    • Steel and Composite Structures
    • /
    • 제3권5호
    • /
    • pp.333-348
    • /
    • 2003
  • The behaviour of composite frame - shear wall systems with regard to creep and shrinkage with high beam stiffness has been largely unattended until recently since no procedure has been available. Recently an accurate procedure, termed the Consistent Procedure (CP), has been developed which is applicable for low as well as for high beam stiffness. In this paper, CP is adapted for a class of composite frame - shear wall systems comprising of steel columns and R.C. shear walls. Studies are reported for the composite systems with high as well as low beam stiffness. It is shown that considerable load redistribution occurs between the R.C. shear wall and the steel columns and additional moments occur in beams. The magnitude of the load redistribution and the additional moment in the beams depend on the stiffness of the beams. It is also shown that the effect of creep and shrinkage are greater for the composite frame - shear wall system than for the equivalent R.C. frame - shear wall system.

벽식 건물의 탄성해석에서 벽체의 모델화 방법 검토 (On Modeling of Shear Wall Element in Eastic Analysis of Building Structures with Shear Walls)

  • 전대한
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.180-187
    • /
    • 1998
  • In this paper the attention is focused on the modeling of reinforced concrete(R/C) wall structures to check effectiveness and reliability of elasto-plastic analysis. A relatively simple and reliable wall model is investigated, which is suitable to be efficiently incorporated in a practical pushover analysis of R/C wall structural systems. Two types of analogous frames have been examined to the stress analysis of shear walls. One analogous frame is similar to the widely used wide-column model, the second analogous frame also is called truss model which includes vertical edge column and braces. Further studies are needed to apply to nonlinear seismic analysis of building structure with R/C shear walls.

  • PDF

비선형 해석으로 평가한 전단벽의 이력거동 특성에 관한 연구 (Hysteretic Behavior Characteristics of R/C Shear Walls Evaluated by Nonlinear Analysis)

  • 김덕주;한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.85-92
    • /
    • 1998
  • Most of tall apartment buildings constructed in our county are wall-type R/C structures composed of hear walls and slabs. It is necessary to evaluate of hysteretic properties of shear walls in wall-type R/C structures which resist lateral loads as well as axial loads. In this study, first to evaluate the wall's hysteretic behavior nonlinear analyses with IDARC 4.0 are performed for eight specimens subjected to horizontal load reversals. As a result of nonlinear analyses of specimens we can obtain three parameters which determined the hysteretic parameters such as stiffness degrading, strength deterioration and inching behavior respectively. With this three parameters, strength and deformation capacity of 5, 10, 20-story shear wall of apartment building is estimated from the results of push-over analysis.

  • PDF

고강도 콘크리트를 사용한 R/C 전단벽의 강도와 변형능력 (Strength and Deformation Capacity of R/C Shear Walls Using High Strength Concrete under Cyclic loads)

  • 오영훈;윤형도;최창식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.72-77
    • /
    • 1990
  • Results are presented of the cyclic loading tests of there low-rise shear wall assembligies using high strength concrete. The possibilities of achieving an acceptable level of energy dissipation in one story shear walls, mainly by flexural yielding, are examined. Mechanisms of flexural and shear resistance are reviewed with emphasis on aspects of sliding shear. Detrimental effects of sliding shear are demonstrated together with improvement achieved by use of diagonal wall reinforcements. It is postulated that with suitably arranged diagonal wall reinforcements a predominantly flexural response mode with good energy dissipation characteristics can be achieved in low-rise shear walls.

  • PDF

한계상태방정식에 의한 R/C 전단벽의 유한요소 간편 해석과 설계 (Simplified Analysis and Design with Finite Element for Reinforced Concrete Shear Walls Using Limit State Equations)

  • 박문호;조창근;이승기
    • 한국전산구조공학회논문집
    • /
    • 제16권1호
    • /
    • pp.43-52
    • /
    • 2003
  • 본 논문은 콘크리트 균열방향의 회전 및 철근의 항복에 따른 2차원 R/C 구조물의 극한거동 덴 한계상태설계에 관한 연구를 다룬 것으로, 유한요소모델에 적용하여 비선형 해석 및 한계상태설계가 가능한 수치 해석 및 설계 알고리즘을 소개하였다. 철근의 설계를 위하여, 각 유한요소의 극한거동에 기초한 한계상태설계방정식이 유한요소 알고리즘에 도입되었다. 한편, 하중에 따른 콘크리트 균열방향의 회전 및 철근의 항복을 고려한 2차원 R/C 평면요소의 단순화된 실용적 비선형 응력-변형률 거동의 구성관계모델을 제시하여 비선형 유한요소해석 알고리즘을 구성하였다 제시된 해석 모델을 R/C 전단벽의 실험모델과 비교하여 검증하도록 하였으며, R/C 전단벽에 대한 설계 예를 통하여, 각각의 유한요소에서 얻어진 설계 철근비를 한계상태설계방정식으로부터 산정하였다.

Seismic behavior of RC building by considering a model for shear wall-floor slab connections

  • Soleimani-Abiat, Mehdi;Banan, Mohammad-Reza
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.381-397
    • /
    • 2015
  • Connections are the most important regions in a structural system especially for buildings in seismic zones. In R.C. structures due to large dimensions of members and lack of cognition of the stress distribution in a connection, reaching a comprehensive understanding of the connection behaviors becomes more complicated. The shear wall-to-floor slab connections in lateral load resisting systems have a potential weakness in transferring loads from slabs to shear walls which might change the path of load transformation to shear walls. This paper tries to investigate the effects of seismic load combinations on the behavior of slabs at their connection zones with the shear walls. These connection zones naturally are the most critical regions of the slabs in RC buildings. The investigation carried on in a simulated environment by considering three different structures with different shear wall layout. The final results of our study reveal that layout of shear walls in a building significantly affects the magnification of forces developed at the shear wall-floor slab connections.

철근 콘크리트 내진벽의 강도와 변형에 대한 실험적 연구 (An Experimental Study on the Strength and Deformation of Reinforced Concrete Shear Wall)

  • 전영주;이동근;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.243-249
    • /
    • 1993
  • The porpose of this study is to suggest an experimental for shear wall of reinforced concrete wall structure. A series of experimental be performed for earned to strength and deformation property of reinforced concrete shear wall. These specimens are three R/C walls among five models which had boundary. As a result, it was found that cyclic experiment is very proper and cyclic time must be increased 3 or 5 times. Monotonic test results was indicated over 15% than other experiment for yielding strength and ultimate strength.

  • PDF

R/C 골조구조물 내진보강을 위한 슬라이딩 벽식감쇠기의 개발 및 비선형 동적해석모델 (Development and Nonlinear Dynamic Model of Sliding Wall Damper To Retrofit of R/C Frame Structures)

  • 조창근;박문호;장준호;김기욱;정인규
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.411-418
    • /
    • 2003
  • In order to retrofit R/C frame structures, a newly proposed Teflon sliding wall damper, consisted of Teflon slider and R/C shear wall, is evaluated by the dynamic analysis model of inelastic frame structures. From analysis results, it is shown that the damper reduces the time-history responses, the maximum story drifts, and the damage of R/C member. By control of damper pressures, especially, the damper can be easily applicable not only to capacity design according to required responses and member damages but also to active damper with actively controlling devices.

  • PDF

R/C 전단벽의 지진이력 거동에 관한 연구 (Identification of Seismic Hysteretic Behavior of R/C Shear Walls)

  • 오순택
    • 콘크리트학회지
    • /
    • 제5권2호
    • /
    • pp.162-170
    • /
    • 1993
  • 축력과 횡력을 받는 전단벽의 휨과 전단 거동을 분리산정하기 위하여 R/C 전단벽에 관한 실험 결과에 대해 System Identification을 행한다. 이를 토대로, 전단벽의 강도 저하 계수 'R'과 극한 회전능력을 구하는 실험식을 제안한다. R/C뼈대구조-전단벽에 대한 비탄성 해석 유한요소 컴퓨터 프로그램(IDARC)을 이용하여 전단벽의 지진 이력 거동을 재현한다. Identification 결과를 Digitize한 실험 결과와의 비교에 의해 검증하고, 총변형으로부터 휨과 전단에 의한 변형요소를 해석적으로 분리 함으로서 비탄성 전단 거동과 강도 저하 계수 'R'의 산정이 가능해진다. 또한 실험 결과에 대한 회귀 분석을 통하여 전단벽의 극한 회전 능력에 대한 실험식이 얻어진다.

벽식마찰감쇄기의 개발 및 R/C 골조구조물에의 해석적 적용 (Development of Frictional Wall Damper and Its Analytical Applications in R/C frame Structures)

  • 조창근;박문호;권민호;강구수;서상길
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.718-725
    • /
    • 2002
  • 본 연구에서는 R/C 골조구조물에 대한 내진성능개선 방법으로서, 벽식 마찰 감쇄기 모델을 새롭게 제안하였다. 기존의 감쇄 장치가 일반적으로 브레이스 부재 형태를 취하고 있으나, 브레이스형 감쇄장치는 시공상 강골조구조물에는 적용하기 용이한 반면 R/C 골조구조물에 적용 시에는 R/C 구조부재와 감쇄기간의 연결 문제, 감쇄기와 R/C 부재 연결부에서의 응력집중으로 인한 R/C 구조부재의 파손 우려 등의 단점이 있다. 제안된 감쇄기는 감쇄기 연결부의 R/C 구조부재 파손 및 구조물의 P-Δ효과를 줄이는데 장점을 가지면서 감쇄기로서의 역할을 발휘하도록 한 테프론 슬라이더와 R/C 전단벽 조합형 감쇄기이다. 제안된 감쇄기의 내진성능개선 능력을 평가하기 위하여, 감쇄기의 수치모델을 고려한 R/C 골조구조물의 비선형 동적해석 알고리즘을 제시하였다. 지진하중이 작용하는 기존의 10층 3경간 R/C 골조구조물에 본 감쇄기를 적용한 수치해석 결과, 시간이력거동 및 층간변위의 억제에서 탁월한 제어효과를 나타내었으며, 저층 기둥 부재의 소성힌지 발생 및 구조부재의 손상을 감쇄기의 소산에너지로 억제하여 줌으로서 구조물 내진성능개선에 효과가 우수한 것으로 평가되었다.