• Title/Summary/Keyword: R/C beam

Search Result 349, Processing Time 0.048 seconds

Using Nanosecond Electron Beam to Produce Silver Nanopowder

  • Balezin, M.E.;Timoshenkova, O.R.;Sokovnin, S.Yu.;Lee, Hi-Min;Rhee, C.K.
    • Journal of Powder Materials
    • /
    • v.15 no.6
    • /
    • pp.466-470
    • /
    • 2008
  • Experiments with a URT-0.5 accelerator (0.5 MeV, 50 ns, 1 kW) generating a nanosecond electron beam for irradiation of silver nitrate in various liquid solutions (water and toluene) were performed with the aim of producing silver nanopowders. A radiochemical reaction allows making weakly agglomerated pure Ag powders with particles of 10-15 nm and 30-50 nm in size by irradiation in toluene and water respectively. The injection of the nanosecond electron beam energy to the solution is optimal. As the absorbed dose increases, the output of the radiochemical reaction does not grow, but more agglomerated powders are synthesized.

A Position control of Ball-Beam using CDM (CDM을 이용한 Ball-Beam 위치제어)

  • 정지연;추연규;임영도
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.139-142
    • /
    • 2002
  • 제어 시스템에서 제어기를 설계하는 방법에는 기존 PID 설계 기법인 Ziegler-Nichols와 Jung, R. C. Dorf 방법들이 있다. 본 논문은 Shunji Manabe의 계수도법(CDM Coefficient Diagram Method)을 이용하여 Ball-Beam 시스템을 제어하기 위한 PID 제어기를 설계한다. PID 제어기의 각 파라메터인 P, I, D 계수는 시스템의 속도와 안정성에 기인하는 표준 안정도 지수$(\gamma)$와 등가시정수$(\tau)$ 로부터 얻 어진다. 등가시정수$(\tau)$와 안정도 지수$(\gamma)$는 제어기 파라메터의 대수적 형태와 절대적인 관계가 있다. 그러므로 설계된 제어기로부터 빠른 상승시간과 안정된 정상상태 응답을 얻을 수 있다. Ball-Beam 시스템에 CDM 제어기를 적용한 결과 시스템의 안정도, 정확성 그리고 강인성에 있어서 퍼지 제어기나 PID 제어기에 비해 뛰어난 응답 특성을 확인하였다

Experimental Efects of Acanthopanax sessiliflorus $S_{EEM}$ Extracts Following Gamma-ray Irradiation on the Body Weight and Serum Lipid Level in Obesity-induced Mice, Regional Cerebral Blood Flow and Blood Pressure in Normal Rats (방사선이 조사된 오갈피 나무의 추출물이 비만 생쥐의 체중 및 혈청내 지질 함량, 정상 흰쥐의 국소 뇌혈류량과 혈압에 미치는 실험적 효과)

  • Cho, Su-In;Kim, Hyung-Woo;Jeong, Sun;Jeon, Byung-Gwan;Kim, Gye-Yeop;Jeong, Hyun-Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.6
    • /
    • pp.1477-1484
    • /
    • 2006
  • This experimental study was designed to investigate the effects of Acanthopanax sessiliflorus $S_{EEM}$ extracts following gamma-ray irradiation on the change of weight, the serum total cholesterol, HDL-cholesterol, LDL-cholesterol, triglyceride, free fatty acid, total lipid, phospholipid level in obese mice induced by high fat diet, and the change of regional cerebral blood flow (rCBF) and blood pressure (BP) in normal rats. Experimental materials were as follows ; 10AS was the bark powder of Acanthopanax sessiliflorus $S_{EEM}$ stems which was exposed in 10 kGy electron beam, 10AS was the bark powder of Acanthopanax sessiliflorus $S_{EEM}$ roots which was exposed in 10 kGy electron beam, 100S was the bark powder of Acanthopanax sessiliflorus $S_{EEM}$ stems which was exposed in 100 kGy electron beam, Experimental groups were as follows ; Normal group was fed with normal diet and administered with distilled water during 5 weeks, Control group was fed with high fat diet and administered with distilled water during 5 weeks, Sample A group was fed with high fat diet and administered with 10AS of 300 mg/kg/mouse/day during 5 weeks, Sample B group was fed with high fat diet and administered with 10AR of 300 mg/kg/mouse/day during 5 weeks, Sample C group was fed with high fat diet and administered with 100AS of 300 mg/kg/mouse/day during 5 weeks. The results were as follows ; Sample A group, Sample B group and Sample C group were significantly decreased body weight and the serum LDL-cholesterol, triglyceride, total lipid level in comparison with Control group. Sample A group, Sample B group and Sample C group were significantly increased the serum HDL-cholesterol level in comparison with Control group. Sample B group and Sample C group were significantly decreased the serum total cholesterol, free fatty acid and phospholipid level in comparison with Control group. This results were suggested that all experimental materials were able to be used for the obesity. 10AS did not changed rCBF and MABP in a dose-dependent manner. 10AR significantly increased rCBR in a dose-dependent manner, and BP did not change in a dose-dependent manner. 100AS decreased rCBF and BP in a dose-dependent manner. This results were suggested that 10 AR significantly increased rCBF by dilating pial arterial diameter. According to above results, the authors suggested that 10AR was able to be used for the obesity and ischemic disease.

Estimation of Nuclear Interaction for $^{11}C$ Cancer Therapy

  • Maruyama, Koichi;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Mizuno, Hideyuki;Iseki, Yasushi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.199-201
    • /
    • 2002
  • Cancer therapy using high-energy $^{12}$ C ions is successfully under way at HIMAC, Japan. An alternative beam to $^{12}$ C is $^{11}$ C ions. The merit of $^{11}$ C over $^{12}$ C is its capability for monitoring spatial distribution of the irradiated $^{11}$ C by observing the $\beta$$^{+}$ decay with a good position resolution. One of the several problems to be solved before its use for therapy is the amount of nuclear interaction that deteriorates the dose concentration owing to the Bragg curve. Utilizing the dedicated secondary beam course for R&D studies at HIMAC, we measured the total energy loss of $^{11}$ C ions in a scintillator block that simulates the soft tissue in human bodies. In addition to the total absorption $^{11}$ C peak, non-negligible bump-shaped contribution is observed in the energy spectrum. The origin of the bump contribution can be nuclear interaction of the incident $^{11}$ C ions with hydrogen and carbon atoms. Further studies to reduce the ambiguity in dose distribution are mentioned.

  • PDF

Measurements of Vibration Intensity of a Coupled Beam (연성보의 진동 인텐시티 측정)

  • Lee, H.H.;Kim, C.R.;Kil, H.G.;Lee, Y.H.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.728-731
    • /
    • 2005
  • The objective of this paper is to perform measurements of vibration intensity of a coupled beam. The propagation of flexural waves generates the out of plane vibration of the coupled beam. The longitudinal waves are generated due to the mode conversion at the structural joint of the coupled beam. The propagation of longitudinal waves generates the in plane vibration of the coupled beam. In order to identify the direction of vibrational power on the coupled beam, the in plane vibration intensity as well as the out of plane vibration intensity needs to be measured. The cross spectral method has been implemented to measure the in-plane vibration intensity as well as out of plane vibration intensity. The results shelved that the experimental method can be effectively used to measure the in-plane vibration intensity as well as the out of plane vibration intensity of coupled beams.

  • PDF

Thermal Hydraulic Power Analysis of the HYPER Target Beam Window (미임계로 표적빔창의 열수력 해석)

  • Song Min-Geun;Ju Eun-Sun;Choi Jin-Ho;Song Tae-Young;Tak Nam-Il;Park Won-Sok
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.39-42
    • /
    • 2002
  • The nuclear transmutation technology to Incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(${\underline{HY}}brid {\underline{P}}ower {\underline{E}}xtraction {\underline{R}}$eactor)is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Lead-bismuth(Pb-Bi) is adopted as a coolant and spallation target material. In this paper, we performed the thermal-hydraulic analysis of HYPER target using the commercial code FLUENT, and also calculated thermal and mechanical stress of the beam window using the commercial code ANSYS. It is found that there is an optimum value for the window diameter and the maximum allowable beam current can be increased to 17.3 mA for the inner diameter of windows, 40 cm. Finally, the other shapes such as uniform or scanned beam were considered. The results of FLUENT calculations show that the uniform type is preferable to the other shapes of the beam in terms of the window and target cooling and the maximum window temperature is lower than that of the parabolic beam by $58 ^{\circ}C$ for the beam current, 13 mA.

  • PDF

Load Transfer Mechanism of a Hybrid Beam-Column Connection System with Structural Tees

  • Kim, Sang-Sik;Choi, Kwang-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.199-205
    • /
    • 2006
  • The composite frame system with reinforced concrete column and steel beam can be improved in its structural efficiency by complementing the shortcomings of the two systems. The system, however, has many inherent problems in practical design and construction process due to the dissimilarities of the materials. Considering these circumstance, this research aims for the development of a composite structural system which connects the steel beams to the R/C columns with higher structural safety and economy. Basically, the proposed connection system is composed of four split tees, structural angles reinforced by a stiffener, high strength steel rods, connecting plates and shear plates. Structural tests have been carried out to investigate the moment transfer mechanism 1Tom the beam flange to steel rods or connecting plates through the structural angle reinforced by a stiffener. The four prototype specimens have been tested until the flange of the beam reached a plastic state. The test results indicated that no distinct material dissimilarities between concrete and steel have been detected for the proposed hybrid beam-column connection system and that the stress transfer through the structural angle between the beam flange and steel rods or connecting plates was very encouraging.

Measurement of Electron Beam Output for the Prototype Compact Linac (콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구)

  • Kim, Sung-Woo;Kang, Sang Koo;Rhee, Dong Joo;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Lee, Mujin;Yang, Kwangmo;Ro, Tae Ik;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • The C-band compact linear accelerator (linac) is being developed at Dongnam Institute of radiological & Medical Sciences (DIRAMS) for medical and industrial applications. This paper was focused on the output measurement of the electron beam generated from the prototype electron linac. The dose rate was measured in unit of cGy/min per unit pulse frequency according to the IAEA TRS-398 protocol. Exradin-A10 Markus type plane parallel chamber used for the measurement was calibrated in terms of dose to water at the reference depth in water. The beam quality index ($R_{50}$) was determined by the radiochromic film with a solid water phantom approximately due to low energy electrons. As a result, the determined electron beam output was $17.0cGy/(min{\cdot}Hz$. The results were used to monitor the accelerator performance during the development procedure.

Development of Planar Active Phased Array Antenna for Detecting and Tracking Radar (화포탐지 레이다용 C-대역 평면형 능동위상배열 안테나 개발)

  • Kim, Ki-Ho;Kim, Hyun;Kim, Dong-Yoon;Jin, Hyung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.924-934
    • /
    • 2018
  • This paper describes the development and measurement results of C-band planar active phase array antenna for detecting and tracking radar(weapon-locating radar). The antenna is designed with 14 sub-arrays(12 main channels and 2 sidelobe blanking channels and approximately 3,000 elements of transmit-receive channel) to generate transmit and digital receive patterns. Using a near-field measurements facility, G/N, transmit patterns, and received patterns are measured. Receive patterns are implemented with digital beamforming by signal processing. The measurement results demonstrate that antenna design specifications were fulfilled.

Field Test of Optical Voltage and Current Meter (광 응용 전류 전압계의 현장실험)

  • Kim, K.C.;Song, J.T.;Song, W.S.;Kim, C.S.;Lee, K.C.;Lee, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.794-798
    • /
    • 1992
  • We present an optical Voltage and current sensor using $BSO(Bi_{12}SiO_{20})$ monocrystal. The voltage and current sensor consist of PBS(Polarizing Beam Splitter), 1/4 wavelength plate, ZnSe, Selfoc lens, LED, and PIN-PD etc. Magnetic core was made using permalloy for applying magnetic field to current sensor effectively. Current was measured from 100 to 1,600 ampere and accuracy was about ${\pm}$5%. The accuracy could be improved to ${\pm}$l% after reducing the nonlinear property of BSO crystal using our own program in PC (IBM286). We noticed that these data were not influenced by 154,000 voltage at all. Applied voltage was reduced to 1/20 using capacitors. And experiment was carried out up to 450V of the reduced voltage. The data fran optical voltage sensor was similar to that from conventional voltage sensor. The accuracy of the data was within about ${\pm}$1%.

  • PDF