• Title/Summary/Keyword: R/C beam

Search Result 349, Processing Time 0.027 seconds

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • Song In Ho;Shin H. S.;Choi C. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.707-710
    • /
    • 2002
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute in Taejon to supply power with Korea Superconducting Tokamak Advanced Research (KSTAR) Neutral Beam Injection (NBI) system. NBI system requires fast cutoff of the power supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply and there are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply, Various results taken during the commissioning phase with a 100kW resistive load and NBI source are shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver and solutions are also presented.

  • PDF

Seismic Performance Evaluation of R/C Different Floor Type Interior Beam-Column Joints in the Middle and High-rise Mixed-use Residential Building (중.고층 주상복합 R/C 건축물의 단차형 내부 보-기둥 접합부 내진성능평가)

  • Ha, Gee-Joo;Shin, Jong-Hak;Huh, Mean-Haeng;Hong, Kun-Ho;Ha, Jae-Hoon;Nam, Young-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.453-454
    • /
    • 2009
  • In this dissertation, experimental program was carried out to study the hysteretic behavior of the reinforced different floor type interior beam-column joint repeated cyclic loads under seismic actions. The test results was as follow. The reinforced interior beam-column joint, designed by the different floor type, was increased energy dissipation capacity and maximum load carrying capacity according to the increase of different floor in comparison to standard specimen. And it was also dissimilar to failure mode adjacent to joint region. energy dissipation capacity of each specimen, designed by the different floor type, was increased 1.1${\sim}$1.35 times in comparison to standard specimen.

  • PDF

Demonstration of the Effectiveness of Monte Carlo-Based Data Sets with the Simplified Approach for Shielding Design of a Laboratory with the Therapeutic Level Proton Beam

  • Lai, Bo-Lun;Chang, Szu-Li;Sheu, Rong-Jiun
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • Background: There are several proton therapy facilities in operation or planned in Taiwan, and these facilities are anticipated to not only treat cancer but also provide beam services to the industry or academia. The simplified approach based on the Monte Carlo-based data sets (source terms and attenuation lengths) with the point-source line-of-sight approximation is friendly in the design stage of the proton therapy facilities because it is intuitive and easy to use. The purpose of this study is to expand the Monte Carlo-based data sets to allow the simplified approach to cover the application of proton beams more widely. Materials and Methods: In this work, the MCNP6 Monte Carlo code was used in three simulations to achieve the purpose, including the neutron yield calculation, Monte Carlo-based data sets generation, and dose assessment in simple cases to demonstrate the effectiveness of the generated data sets. Results and Discussion: The consistent comparison of the simplified approach and Monte Carlo simulation results show the effectiveness and advantage of applying the data set to a quick shielding design and conservative dose assessment for proton therapy facilities. Conclusion: This study has expanded the existing Monte Carlo-based data set to allow the simplified approach method to be used for dose assessment or shielding design for beam services in proton therapy facilities. It should be noted that the default model of the MCNP6 is no longer the Bertini model but the CEM (cascade-exciton model), therefore, the results of the simplified approach will be more conservative when it was used to do the double confirmation of the final shielding design.

Structural member stiffness influence on vertical earthquake behaviour of mid-rise R/C frame buildings in Turkey

  • Selcuk Bas
    • Computers and Concrete
    • /
    • v.33 no.6
    • /
    • pp.689-706
    • /
    • 2024
  • This study is aimed at identifying structural element stiffness influence on vertical earthquake response of mid-rise R/C frame buildings. To this aim, a mid-rise RC building structure is designed as per the new Turkish Seismic Code for Buildings-2018, and 3D FE model of the building is established. Based on the established FE model, a total number of six buildings are considered depending on certain percentage increase in beam, slab, and column. The time-history response analyses (THA) are performed separately for only horizontal (H) and horizontal +vertical (H+V) earthquake motions to make a comparison between the load cases. The analysis results are presented comparatively in terms of the monitoring parameters of the base overturning moment (Mo), the top-story lateral displacement (dL) and the top-story vertical displacement (dV). The obtained results reveal that the base overturning moment and the top-story vertical displacement are affected by vertical earthquake motion regardless of the increase in the dimension of beam, slab, and column. However, vertical earthquake motion is not effective on the top-story lateral displacement due to no change between H and H+V load. The dimensional increase in either slab or beam leads to a considerable increase in the base overturning moment and the top-story vertical displacement while causing decrease in the top-story lateral displacement. In addition, the dimensional increase in column has a positive effect on the decrease in the monitoring parameters of the base overturning moment (Mo), the top-story lateral displacement (dL) and the top-story vertical displacement (dV).

Etching of the PDP barrier rib material using laser beam (레이저빔에 의한 PDP 격벽 재료의 식각)

  • Ahn, Min-Young;Lee, Kyoung-Cheol;Lee, Hong-Kyu;Lee, Sang-Don;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.6
    • /
    • pp.526-532
    • /
    • 2000
  • The paste on the glass or fabrication of the PDP(Plasma Display Panel) barrier rib was selectively etched using focused A $r_{+}$ laser(λ=514 nm) and Nd:YAG(λ=532, 266 nm) laser irradiation. The depth of the etched grooves increase with increasing a laser fluence and decreasing a laser beam scan speed. Using second harmonic of Nd:YAG laser(532 nm) the etching threshold laser fluence was 6.5 mJ/c $m^2$ for the sample of PDP barrier rib. The thickness of 180 ${\mu}{\textrm}{m}$ of the sample on the glass was clearly removed without any damage on the glass substrate by fluence of 19.5J/c $m^2$beam scan speed of 20${\mu}{\textrm}{m}$ /s. In order to increase the etch rate of the barrier rib material barrier rib samples heated by a resistive heater during laser irradiation. The heated sample has many defects and becomes to be fragile. This imperfection of the structure compared to the sample without heat treatment allows the effective etching by the focused laser beam. The etch rates were 65${\mu}{\textrm}{m}$/s and 270 ${\mu}{\textrm}{m}$/s at room temperature and 20$0^{\circ}C$, respectively.y.

  • PDF

Automotive Adaptive Front Lighting Requiring Only On/Off Modulation of Multi-array LEDs

  • Lee, Jun Ho;Byeon, Jina;Go, Dong Jin;Park, Jong Ryul
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.207-213
    • /
    • 2017
  • The Adaptive Front-lighting System (AFS) is a part of the active safety system, providing optimized vision to the driver during night time and other poor-sight conditions of the road by automatic adaptation of lighting to environmental and traffic conditions. Basically, an AFS provides four different modes of the passing beam as designated in an United Nations Economic Commission for Europe regulation (ECE324-R123): neutral state or country light (Class C), urban light (Class V), highway light (Class E), and adverse weather light (Class W). In this paper, we first present an optics design for an AFS system capable of producing the Class C/V/E/W patterns requiring only on/off modulation of multi-array LEDs with no need for any additional mechanical components. The AFS optics consists of two separated modules, cutoff and spread; the cutoff module lights a narrow central area with high luminous intensity, satisfying the cutoff regulation, and the spread module forms a wide spread beam of low luminous intensity. Each module consists of two major parts; the first converts a discretely positioned LED array into a full-filled area emitting light source plane, and the second projects the light source plane to a 25 m away target plane. With the combination of these two optics modules, the four beam patterns are formed by simple on/off modulation of multi-array LEDs. Then we report the development of a prototype that was demonstrated to provide the four beam patterns.

Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections With Intermediate Moment Frame Details (중간모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가)

  • Kim, Seon Hoon;Cho, Jong;Oh, Hyo Keun;Choi, Seok Dong;Yeo, Un Yong;Lee, Deuck Hang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.129-137
    • /
    • 2023
  • This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.

Improvement and Evaluation of Seismic Performance of Reinforced Concrete Exterior Beam-Column Joints Retrofitting with Fiber Reinforced Polymer Sheets and Embedded CFRP Rods (섬유시트와 매입형 CFRP Rod를 보강한 R/C 외부 보-기둥 접합부의 내진성능 평가 및 개선)

  • Ha, Gee-Joo;Ha, Young-Joo;Kang, Hyun-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.151-159
    • /
    • 2015
  • In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (CFRP sheet, AFRP sheet, embedded CFRP rod) in existing reinforced concrete structure. Therefore it was constructed and tested seven specimens retrofitting the beam-column joint regions using such retrofitting materials. Specimens, designed by retrofitting the beam-column joint regions of existing reinforced concrete structure, were showed the stable failure mode and increase of load-carrying capacity due to the effect of crack control at the times of initial loading and confinement of retrofitting materials during testing. Specimens LBCJ-CRUS, designed by the retrofitting of CFRP Rod and CFRP Sheet in reinforecd beam-column joint regions were increased its maximum load carrying capacity by 1.54 times and its energy dissipation capacity by 2.36 times in comparison with standard specimen LBCJ for a displacement ductility of 4 and 7. And Specimens LBCJ-CS, LBCJ-AF series were increased its energy dissipation capacity each by 2.04~2.34, 1.63~3.02 times in comparison with standard specimen LBCJ for a displacement ductility of 7.

Optimization of Reinforced Concrete Frames Subjected to Dynamic Loads (동적 거동을 받는 철근 콘크리트 뼈대 구조의 최적화)

  • Park, Moon Ho;Kim, Sang Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.439-452
    • /
    • 1994
  • A method to optimize the cost of R/C frames and an algorithm of the optimal limit state design for R/C frames subjected to dynamic loads are presented. The modal superposition method was used to find the dynamic responses of the frames. Each member of R/C frame is made up of more than two elements and the stiffness matrix and consistent mass matrix of three d.o.f in the node of each element was used to include axial, shear and flexural effects. The objective function to be minimized formulated the cost of materials, steel and concrete, and optimised to satisfy the behaviors of R/C frame and each constraint imposed by the limit state requirements. Both objective function and each constraint are derived in terms of design variables which include the effective depth, beam width, compression and tension steel area, and column shear steel area. A few applications are presented which demonstrate the feasibility, the validity and efficiency of the algorithm for automated optimum design of R/C frames where dynamic behavior is to be considered.

  • PDF

Three dimensional analysis of reinforced concrete frames considering the cracking effect and geometric nonlinearity

  • Kara, Ilker Fatih;Dundar, Cengiz
    • Structural Engineering and Mechanics
    • /
    • v.31 no.2
    • /
    • pp.163-180
    • /
    • 2009
  • In the design of tall reinforced concrete (R/C) buildings, the serviceability stiffness criteria in terms of maximum lateral displacement and inter-story drift must be satisfied to prevent large second-order P-delta effects. To accurately assess the lateral deflection and stiffness of tall R/C structures, cracked members in these structures need to be identified and their effective member flexural stiffness determined. In addition, the implementation of the geometric nonlinearity in the analysis can be significant for an accurate prediction of lateral deflection of the structure, particularly in the case of tall R/C building under lateral loading. It can therefore be important to consider the cracking effect together with the geometric nonlinearity in the analysis in order to obtain more accurate results. In the present study, a computer program based on the iterative procedure has been developed for the three dimensional analysis of reinforced concrete frames with cracked beam and column elements. Probability-based effective stiffness model is used for the effective flexural stiffness of a cracked member. In the analysis, the geometric nonlinearity due to the interaction of axial force and bending moment and the displacements of joints are also taken into account. The analytical procedure has been demonstrated through the application of R/C frame examples in which its accuracy and efficiency in comparison with experimental and other analytical results are verified. The effectiveness of the analytical procedure is also illustrated through a practical four story R/C frame example. The iterative procedure provides equally good and consistent prediction of lateral deflection and effective flexural member stiffness. The proposed analytical procedure is efficient from the viewpoints of computational effort and convergence rate.