본 논문에서는 Risk-based design개념을 반영하여 체계적인 설계방향을 제시하고 현존하는 법에 더욱 안전한 방향으로 법안이나 규격을 수정할 수 있는 방안을 제시하려고 한다. 안전설계 부분의 초기설계 집중도 및 수준을 향상시키기 위하여 설계 초기단계에서부터 체계화된 안전설계 요소의 정보를 제공할 수 있는 새로운 Advanced Safety Analysis Table(ASAT)을 개발하였다. 또한 ASAT를 토대로 공정 트러블에 따른 안전장치를 선택하는 방법에 대한 가이드라인을 개발하였다. 개발된 ASAT, 공정 트러블에 따른 안전장치를 선택방법의 사례 연구로 NCC(Naphtha Cracking Center) 공정의 PGC(Process Gas Compressor)에 대한 ASAT를 구축하고 공정 트러블에 따른 안전장치를 선택한 결과를 분석하였다.
The acquisition cost of defense weapon system has been continuously increasing because of art-of-technology of it. This phenomenon requires efficiency and transparency in the weapon system acquisition process through cost estimation. Therefore cost estimation is very important to the government acquisition programs to support decisions about funding and to evaluate resource requirement as a key decision point. The Commercial parametric cost estimating models have been using extensively to obtain appropriate cost estimates in early acquisition phase. These models have many restrictions to ensure the cost estimating result in Korean defense environment because they are developed based on foreign R&D data. Also estimation results are different from Korean defense industry accounting system. So, some studies have been tried to develop a CER (Cost Estimation Relationship) based on the Korean historical data. However, there are some restrictions to improve the predictability and ensure the stability of the developed singular CERs which consider the following data characteristics individually. The the abnormal conditions of data that is multicollinearity, outlier and heteroscedasticity under rack of the number of observations. In this paper, a CER's Linear Combining Model is proposed to overcome those limitations which guarantee more accurate estimation (25.42% higher precision) than other singular CERs. At least, this study is meaningful as a first attempt to improve the predictability of CER with insufficient data. The methodology suggested in this study will be useful to develop a complex Korean version cost estimating model development in future.
Generally, ceramic material is very difficult to machine due to high strength and hardness. However, ceramic material can be machined at high temperature by plastic flow as metallic material due to the deterioration of the grain boundary glassy phase. Recently, a new method was developed to execute cutting process with CBN cutting tool by local heating of surface with laser. There are various parameters in LAM because it is a complex process with laser treatment and machining. During laser assisted machining, high power results in reducing of cutting force and increasing tool life, but excessive power brings oxidation of the surface. The effect of laser power, feed rate, cutting depth and etc. were investigated on the life of cutting tool. Chips were observed to find out suitable machining conditions. Chips of SSN had more flow-types than HIPSN. It means SSN is easier to machining. The life of cutting tool was increased with increasing laser power and decreasing feed rate and cutting depth.
Fluoroquinolones in muscle and egg were separated by liquid extraction and determined. The analysis was carried out using following conditions; C18 column ($150{\times}4.6mm$, $5{\mu}m$), mobile phase composed of D.W. (containing 0.4% triethylamine and phosphoric acid) : methanol : acetonitrile (780:100:120, v/v/v), quarternary pump at a flow rate of 0.9ml/min and $20{\mu}l$ of injection volume, fluorescence detector with EX 278nm/Em 456nm. The calibration range of seven fluoroquinolones showed linearity ($r^2{\geq}0.999$) at concentration range of $0.025{\sim}0.8{\mu}g/ml$. The recoveries in fortified muscle and egg represented more than 81.3%. The detection limits for ofloxacin, norfloxacin, ciprofloxacin, enrofloxacin, danofloxacin, saraloxacin and orbifloxacin were 3.1, 2.5, 3.6, 1.7, 0.9, 2.5 and $2.1{\mu}g/kg$, respectively. We also monitored fluoroquinolones residue in the sample (chicken muscle 182, cattle muscle 140, pig muscle 139, egg 212) using EEC-plate (E. coli ATCC 11303) screening and HPLC confirmation methods. The screening test results, fluoroquinolones, antibacterial substances were all negative.
본 연구에서는 고출력 자동차 헤드램프용 LD 에 적용 가능한 garnet 구조의 YAG : Ce 형광체 세라믹 플레이트를 제작하고 광학 특성을 분석하였다. 액상법을 이용하여 단분산된 구형 나노 YAG : Ce 입자를 합성하고 이를 $Al_2O_3$와 혼합하여 형광체 세라믹 플레이트를 제작하였다. 형광체 세라믹 플레이트의 두께를 $75{\mu}m$, $100{\mu}m$로 조절하여 두께에 따른 광 변환 효율, 열 소광(Thermal quenching), 휘도 및 색온도의 광학 특성을 비교하였다. 실험 결과, 광 변환 효율의 감소 폭은 모두 25 % 감소하였고, 열 소광, 최대 광 변환 효율 값, 최대 휘도 값은 $100{\mu}m$ 일 때 더 높게 나타났다.
본 논문에는 30 cm 해상도를 갖는 소형 SAR(Synthetic Aperture Radar) 시스템 개발 결과를 소개하고, RAW 데이터 기반의 도플러 파라미터 추정 및 요동 보상 신호처리 알고리즘을 제시한다. 송수신 채널이 각각 2개이기 때문에 다중 편파 및 간섭계 영상 확보가 가능하며, 차량 탑재 시험을 통하여 다중 편파 SAR 데이터 획득 및 신호 처리 결과를 제시하였다. 플랫폼의 요동에 의한 잔여 위상 오차를 보상하는 알고리즘을 적용하였으며, 실제 차량 탑재 시험을 통하여 요동 보상에 따른 개선된 성능 결과를 제시하였다.
탄성파 전파 과정의 정량적인 이해와 그 가시화는 결함 탐지는 물론이고, 재료의 물성 평가에 매우 중요하다. 대상 재료가 이방성을 지닐 경우에 탄성파 전파 과정은 복잡해져서 전파 과정의 해석 및 가시화 작업은 탄성파를 이용하는 결함 탐지 및 재질 평가에서는 필수적이다. 이방성 재료에서는 탄성파의 속도가 방향에 따라서 달라짐은 물론이고, 위상 속도와 군 속도의 방향이 어긋나서 파면이 진행하는 방향과 에너지가 진행하는 방향이 달라진다(beam skewing 효과). 특히 복합재료와 같이 이방성이 큰 재료에서는 이 효과가 매우 크게 나타나므로 탄성파를 이용한 시험 결과를 해석하고자 할 때에는 반드시 전파 과정을 이해해야 한다. 이방성 재료에 대해 해석적인 접근에는 한계가 있어서 유한차분법(finite difference method: FDM)과 같은 수치 해석 방법이 유용하게 사용되고 있다. 본 연구에서는 탄성파 전파 과정을 해석할 수 있는 2차원 FDM 프로그램을 개발하고, 이를 이용하여 이방성 재료에서의 탄성파 전파에 대한 전산 시뮬레이션 결과를 비교 분석한다.
Goat milk is highly nutritious and is consumed in many countries, but the development of functional foods from goat milk has been slow compared to that for other types of milk. The aim of this study was to develop a goat milk protein hydrolysate (GMPH) with enhanced digestibility and better hypoallergenic properties in comparison with other protein sources such as ovalbumin and soy protein. Goat milk protein was digested with four commercial food-grade proteases (separately) under various conditions to achieve the best hydrolysis of αs -casein and β-lactoglobulin. It was shown that treatment with alcalase (0.4%, 60℃ for 30 min) effectively degraded these two proteins, as determined by SDS-PAGE, measurement of nonprotein nitrogen content, and reverse-phase high-performance liquid chromatography. Hydrolysis with alcalase resulted in a significant decrease in β-lactoglobulin concentration (almost to nil) and a ~40% reduction in the level of αs-casein. Quantification of histamine and TNF-α released from HMC-1 cells (human mast cell line) showed that the GMPH did not induce an allergic response when compared to the control. Hence, the GMPH may be useful for development of novel foods for infants, the elderly, and convalescent patients, to replace cow milk.
Kim, Sang Hoon;Lee, Ji Yoon;Balolong, Marilen P.;Kim, Jin-Eung;Paik, Hyun-Dong;Kang, Dae-Kyung
한국축산식품학회지
/
제37권3호
/
pp.402-409
/
2017
A novel peptide having free radical scavenging activity was separated, using an on-line high-performance liquid chromatography (HPLC) - ABTS screening method, from bovine skim milk fermented by Lactococcus lactis SL6 (KCTC 11865BP). It was further purified using reverse phase-HPLC (RP-HPLC) and sequenced by RP-HPLC-tandem mass spectrometry. The amino acid sequence of the identified peptide was determined to be Phe-Ser-Asp-Ile-Pro-Asn-Pro-Ile-Gly-Ser-Glu-Asn-Ser-Glu-Lys-Thr-Thr-Met-Pro-Leu-Trp (2,362 Da), which is corresponding to the C-terminal fragment of bovine ${\alpha}_{s1}$-casein (f179-199). The hydroxyl radicals scavenging activity ($IC_{50}$$28.25{\pm}0.96{\mu}M$) of the peptide chemically synthesized based on the MS/MS data showed a slightly lower than that of the natural antioxidant Trolox ($IC_{50}$$15.37{\pm}0.52{\mu}M$). Furthermore, derivatives of the antioxidant peptide were synthesized. The antioxidative activity of the derivatives whose all three proline residues replaced by alanine significantly decreased, whereas replacement of two proline residues in N-terminal region did not affect its antioxidative activity, indicating that $3^{rd}$ proline in C-terminal region is critical for the antioxidative activity of the peptide identified in this study. In addition, N-terminal region of the antioxidant peptide did not show its activity, whereas C-terminal region maintained antioxidative activity, suggesting that C-terminal region of the peptide is important for antioxidative activity.
Maskani, Reza;Tahmasebibirgani, Mohammad Javad;Hoseini-Ghahfarokhi, Mojtaba;Fatahiasl, Jafar
Asian Pacific Journal of Cancer Prevention
/
제16권17호
/
pp.7795-7801
/
2015
The aim of the present research was to establish primary characteristics of electron beams for a Varian 2100C/D linear accelerator with recently developed PRIMO Monte Carlo software and to verify relations between electron energy and dose distribution. To maintain conformity of simulated and measured dose curves within 1%/1mm, mean energy, Full Width at Half Maximum (FWHM) of energy and focal spot FWHM of initial beam were changed iteratively. Mean and most probable energies were extracted from validated phase spaces and compared with related empirical equation results. To explain the importance of correct estimation of primary energy on a clinical case, computed tomography images of a thorax phantom were imported in PRIMO. Dose distributions and dose volume histogram (DVH) curves were compared between validated and artificial cases with overestimated energy. Initial mean energies were obtained of 6.68, 9.73, 13.2 and 16.4 MeV for 6, 9, 12 and 15 nominal energies, respectively. Energy FWHM reduced with increase in energy. Three mm focal spot FWHM for 9 MeV and 4 mm for other energies made proper matches of simulated and measured profiles. In addition, the maximum difference of calculated mean electrons energy at the phantom surface with empirical equation was 2.2 percent. Finally, clear differences in DVH curves of validated and artificial energy were observed as heterogeneity indexes were 0.15 for 7.21 MeV and 0.25 for 6.68 MeV. The Monte Carlo model presented in PRIMO for Varian 2100 CD was precisely validated. IAEA polynomial equations estimated mean energy more accurately than a known linear one. Small displacement of R50 changed DVH curves and homogeneity indexes. PRIMO is a user-friendly software which has suitable capabilities to calculate dose distribution in water phantoms or computerized tomographic volumes accurately.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.