• Title/Summary/Keyword: Quartz tube

Search Result 104, Processing Time 0.026 seconds

Direct Observation of Premixed Flame Propagation Characteristics in an Annular Coaxial 5-Tubes Burner (환형 5중 동축관 연소기 내부에서의 예혼합 화염의 전파 특성 직접 관찰)

  • Cho, Moon Soo;Baek, Da Bin;Kim, Nam Il
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.3
    • /
    • pp.24-30
    • /
    • 2013
  • Flame stabilization characteristics of premixed flames in an annular coaxial 5-tubes burner (AC5TB) were investigated experimentally. The AC5TB was made of five quartz tubes, and the flame stabilization conditions in that burner were investigated with the variation of equivalence ratio and the flow velocities. Flame behaviors inside of narrow annular tubes could be observed directly. Overall flame stabilization conditions were similar to that of the previous study, while the flame behaviors and structures were different mainly due to the controlled uniform distribution of the velocities in channels. Flame flashback conditions were thought to be governed by the competition between heat release rate, heat loss and heat recirculation in each channel. Stationary flames at a fixed location were compared in its velocity distribution and burned gas temperature across the channel. This AC5TB can be a basic configuration for the development of flame stabilization model of porous media combustors, and it will help understand about the real behavior of flames in meso-scale combustion spaces.

AN EXPERIMENTAL STUDY ON HARDNESS IN COMPOSITE RESINS (수종복합레진의 경도측정에 관한 실험적 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.4 no.1
    • /
    • pp.35-38
    • /
    • 1978
  • The purpose of this study was to measure micro-knoop hardness and coefficient of thermal expansion on composite resins (Epolite, Adaptic, Hipol and Compo T.) Four different type of composite resins were measured at the varying depth of 30, 60, 90, 150, 200, 400, 700 and 1000 micron from the surface to deep portion. The specimens were stored both in the air room temperature for 2 days, 30 days and in water at $37^{\circ}C$ for 30 days. Thermal expansions of specimens(4mm in diameter and 50mm in height) were measured in quartz tube dilatometer from $20^{\circ}$ to $70^{\circ}C$ The following results were obtained. 1. The hardness of superficial portion were lower than inner portion of resin. 2. The value of hardness obtained from the specimen stored in room temperature in the water at $37^{\circ}C$ for 30 days were lower than above described Cases. 3. The coefficient of thermal expansion of Adaptic had $29.75{\times}10^{-6}/^{\circ}C$, Hipol had $30{\times}10^{-6}/^{\circ}C$, Epolite had $39.85{\times}10^{-6}/^{\circ}C$ and Compo T had $36.95{\times}10^{-6}/^{\circ}C$.

  • PDF

Influence of the Density Gradient on the Current of the Electrode Immersed in the Non-uniform Plasma (플라즈마 삽입전극의 전류에 미치는 밀도 구배의 영향)

  • Hwang, Hui-Dong;Gu, Chi-Wuk;Chung, Kyung-Jae;Choe, Jae-Myung;Kim, Gon-Ho;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.6
    • /
    • pp.504-509
    • /
    • 2011
  • The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV~6 kV to measure the conduction current for the analysis of ion current.

Reflood Experiments with Horizontal and Vertical Flow Channels

  • Chung, Moon-Ki;Lee, Seung-Hyuck;Park, Choon-Kyung;Lee, Young-Whan
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.153-162
    • /
    • 1980
  • The investigation of the fuel cladding temperature behavior and heat transfer mechanism during the reflooding phase of a LOCA plays an important role in performance evaluation of ECCS and safety analysis of water reactors. Reflooding experiments were performed with horizontal and vertical flow channels to investigate the effect of coolant flow channel orientation on rewetting process. Emphasis was mainly placed on the CANDU reactor which has horizontal pressure tubes in core, and the results were compared with those of vertical channel. Also to investigate the rewetting process visually, the experiments by using a rod in annulus and a quartz tube heated outside were performed. It can be concluded that the rewetting velocity in horizontal flow channel is clearly affected by flow stratification, however, the average rewetting velocity is similar to those in vertical flow channel for same conditions.

  • PDF

Changes of Free Radical Concentrations with Irradiation Dose and Storage Time in Gamma-Irradiated Sesame and Perilla Seeds (감마선 조사된 참깨, 들깨의 조사선량과 저장기간에 따른 free radical 농도의 변화)

  • Lee, Eun-Jeong;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.396-399
    • /
    • 2002
  • Electron spin resonance (ESR) spectroscopy was used to investigate the effect of irradiation dose and storage time on the free radical concentrations in gamma-irradiated sesame (Korean and Sudan) and perilla seeds (Korea). The samples were sealed with packed pyrex tube (50 g respectively) and then irradiated with doses of 0, 1, 5 and 10 kGy at room temperature using a Co-60 irradiator. Each sample in ESR quartz tube were calculated with ESR signals by Bruker-EPR spectrometer for 4 weeks. Free radicals detected for irradiated and unirradiated samples were higher than those of unirradiated ones. Since the free radical concentrations linearly incresed with the applied doses $(1{\sim}10\;kGy)$, highly positive correlation coefficients $(R^2=0.9926{\sim}0.9994)$ were obtained between irradiation doses and free radical concentrations right after irradiation. Although the free radical concentrations decreased with storage time, the signals of free radical in irradiated samples were observed even after 4 weeks of storage at room temperature.

Inactivation of Ralstonia Solanacearum Using Aquatic Plasma Process (수중 Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.797-804
    • /
    • 2012
  • A dielectric barrier discharge (DBD) plasma reactor was investigated for the inactivation of Ralstonia Solanacearum which causes bacterial wilt in aquiculture. The DBD plasma reactor of this study was divided into power supply unit, gas supply unit and plasma reactor. The plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the optimum 1st voltage, 2nd voltage, air flow rate and pH were for 100 V (1st voltage), 15 kV (2nd voltage), 4 L/min, and pH 3, respectively. At a low 1st voltage, shoulder and tailing off phenomena was observed. The shoulder phenomenon was decreased as the increase of 1st voltage. R. Solanacearum disinfection in the lower air flow rate was showed shoulder and tailing off phenomenon because the active species generated less. Under optimum condition, shoulder and tailing off phenomenon was reduced. When the 2nd voltage was less than 7.5 kV, tailing off phenomenon was observed and this was not vanishes even though the increase of the disinfection time. The inactivation efficiency increased as the increase of air flow rate, however, the efficiency decreased when the air flow rate was above 4 L/min. R. Solanacearum disinfection at pH 3 showed somewhat higher than in pH 11. The pH effect of R. Solanacearum deactivation is less than the impact on other factor.

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

Photo-decomposition Characteristics of 2,4,6-Trinitrotoluene in a UV/$H_2O_2$ Process (2,4,6-Trinitrotoluene (TNT)의 광분해 특성)

  • Kwon, Bum-Gun;Choi, Won-Yong;Yoon, Je-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.775-788
    • /
    • 2010
  • The decomposition of 2,4,6-trinitrotoluene (TNT) and the mass balance of nitrogen (N) species as products were investigated in a UV/H2O2system by varying pH, concentrations of $H_2O_2$, and $O_2$. All experiments were conducted in a semi-batch system employing a 50 mL reaction vessel and a coil-type quartz-tube reactor. In contrast with previous studies employing batch mode, TNT decomposition in the semi-batch mode was proportionally enhanced by increasing $H_2O_2$ concentration to 10 mM (0.034%), indicatingthat an inhibitory effect of excess $H_2O_2$on hydroxyl radical (${\cdot}OH$) can be negligible. N compounds are released as $NO_2^-$ in the early stages of the reaction, but $NO_2^-$ is rapidly oxidized to $NO_3^-$ by means of ${\cdot}OH$. $NH_4^+$ was also detected in this study and showed gradually the increase with increasing reaction time. In this study, $NH_4^+$ production can involve the reduction of nitro group of TNT concurrent with the production of $NO_3^-$. Of the N species originating from TNT decomposition, 12 ~ 72% were inorganic forms (i.e. [$NO_3^-$] + [$NO_2^-$] + [$NH_4^+$]). This result suggests that the large remaining N portions indicate that unidentified N compounds can exist.

Polymerization and Application of Contact Lens Materials (콘택트렌즈 재료의 합성과 응용에 관한 연구)

  • Song, Kyung-Sek;Lee, Jong-Heon;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.129-134
    • /
    • 2003
  • A wide variety of unsaturated vinyl derivatives can be induced to undergo free-radical chain polymerization. The capability to carry out a thermodynamically feasible polymerization relies on its kinetic feasibility on whether the proceeds at a reasonable rate under a given set of reaction conditions. Initiator or promoter is often required to achieve the kinetic feasibility. Only a few unsaturated monomers including methyl methacrylate(MMA) are known to absorb light between 250 and 500 nm which is the most convenient wavelength range. Also, the polysilanes with unusual optical and electronic properties have been used as ceramic precursors, deep UV photoresists, photoconductors. The hydrosilation has been used to make many interesting types of silicon containing polymers such as copolymer, dendrimers. Bulk polymerization of monomers with different molar radio of hydrosilanes(9:1 through 1:9) were performed. A quartz test tube charged with monomer and hydrosilane was degassed and irradiated with 250 nm UV for 6 hours. The polymer was taken in toluene, precipitated in hexane, filtered off, and dried. It was found that the initiators appeared to competitively and concurrently function as both chain initiation and transfer agents in the polymerization of vinyl monomers.

  • PDF

Studies on Simultaneous Analysis of Organophosphorus Pesticide Residues in Crops by Gas-Liquid Chromatography (II). Separation of Pesticides by Capillary Column (기체-액체 크로마토그래피에 의한 농작물 중 유기인제 잔류농약의 동시 분석에 관한 연구 (제 2 보). 모세관 컬럼에 의한 분리)

  • Kim, Taek-Jae;Eo, Yun-Woo;Kim, Young-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.236-243
    • /
    • 1987
  • The optimum resolution condition of 11 organophosphorus pesticides by gas-liquid chromatography was studied using a capillary column. The injection modes and types of vaporization tubes were evaluated in relation to pesticide analysis. The best reproducibility of peak heights of pesticides was obtained by the split mode with the vaporization tube packed with quartz wool. A 25m SE-30 capillary column provided better resolution than SE-54 column for their optimum resolution. The column at $200^{\circ}C$ initially was heated by $5^{\circ}C/min\;to\;230^{\circ}C$ followed by $10^{\circ}C/min\;to\;270^{\circ}C$ and the temperatures were held constant for 5 minutes at $230^{\circ}C\;and\;270^{\circ}C$, respectively. The relative standard deviations of their retention times were less than 0.19%.

  • PDF