• 제목/요약/키워드: Quantitative ultrasound

검색결과 145건 처리시간 0.02초

초음파골밀도측정기 정도관리 방안제시를 위한 한국 초음파골밀도 사용현황 조사 (Survey on Usage of Korean Quantitative Ultrasound for Proposing Quantitative Ultrasound Quality Control Guideline)

  • 정윤지;김미정;이승열;이태희;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.329-337
    • /
    • 2018
  • This study was investigated quantitative ultrasound (QUS) usage in Korea for the QUS quality control guidelines. A total of 344 questionnaires collected from July 24th to August 25th 2017 were analyzed. Questionnaires were created through user interviews, expert group advice, literature review and field observation. As a result of the general characteristics of quantitative ultrasound holding amounted to 81.98% of clinic and 6.69% of hospitals. The main user was radio-logical technologists as 31.39%. The contact methods of the gel pad (balloon) were the most used at 56.68% and the scan region was 91.9% of calcaneus. The quantitative ultrasound quality control cycle was 67.37% when the abnormality was found in the equipment, and 63.66% when the accuracy control was implemented according to the manual. The phantoms of QUS were 34.30% of the manufacturer's own phantoms. User of QUS had never received education for quality control of quantitative ultrasound as 62.20%. This study was expected to be useful when creating detailed quality control guidelines in the future, as well as guidelines for the quality control of Korea's standard quantitative ultrasound.

Quantitative Evaluation of Hepatic Steatosis Using Advanced Imaging Techniques: Focusing on New Quantitative Ultrasound Techniques

  • Junghoan Park;Jeong Min Lee;Gunwoo Lee;Sun Kyung Jeon;Ijin Joo
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.13-29
    • /
    • 2022
  • Nonalcoholic fatty liver disease, characterized by excessive accumulation of fat in the liver, is the most common chronic liver disease worldwide. The current standard for the detection of hepatic steatosis is liver biopsy; however, it is limited by invasiveness and sampling errors. Accordingly, MR spectroscopy and proton density fat fraction obtained with MRI have been accepted as non-invasive modalities for quantifying hepatic steatosis. Recently, various quantitative ultrasonography techniques have been developed and validated for the quantification of hepatic steatosis. These techniques measure various acoustic parameters, including attenuation coefficient, backscatter coefficient and speckle statistics, speed of sound, and shear wave elastography metrics. In this article, we introduce several representative quantitative ultrasonography techniques and their diagnostic value for the detection of hepatic steatosis.

Comparative Study of Contrast-Enhanced Ultrasound Qualitative and Quantitative Analysis for Identifying Benign and Malignant Breast Tumor Lumps

  • Liu, Jian;Gao, Yun-Hua;Li, Ding-Dong;Gao, Yan-Chun;Hou, Ling-Mi;Xie, Ting
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권19호
    • /
    • pp.8149-8153
    • /
    • 2014
  • Background: To compare the value of contrast-enhanced ultrasound (CEUS) qualitative and quantitative analysis in the identification of breast tumor lumps. Materials and Methods: Qualitative and quantitative indicators of CEUS for 73 cases of breast tumor lumps were retrospectively analyzed by univariate and multivariate approaches. Logistic regression was applied and ROC curves were drawn for evaluation and comparison. Results: The CEUS qualitative indicator-generated regression equation contained three indicators, namely enhanced homogeneity, diameter line expansion and peak intensity grading, which demonstrated prediction accuracy for benign and malignant breast tumor lumps of 91.8%; the quantitative indicator-generated regression equation only contained one indicator, namely the relative peak intensity, and its prediction accuracy was 61.5%. The corresponding areas under the ROC curve for qualitative and quantitative analyses were 91.3% and 75.7%, respectively, which exhibited a statistically significant difference by the Z test (P<0.05). Conclusions: The ability of CEUS qualitative analysis to identify breast tumor lumps is better than with quantitative analysis.

인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구 (A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence)

  • 임연진;황호성;김동현;김호철
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

연령에 따른 정상 골격근의 초음파 영상 분석 (Age Related Analysis of Ultrasound Images of Normal Skeletal Muscle)

  • 정진규;김계엽;김종만;김태열
    • 한국전문물리치료학회지
    • /
    • 제13권1호
    • /
    • pp.47-53
    • /
    • 2006
  • Since ultrasound has different reflections depending on components of organization, analysis of ultrasound images of skeletal muscle can offer both quantitative and qualitative reports as concerns skeletal muscle structure. This study is focused on the ultrasound method for evaluating the structural characteristics of skeletal muscle and also conducted to examine its practicality. After obtaining images of the elbow flexors from an ultrasound image device with 88 normal subjects whose ages were between twenty and seventy years old (44 men and 44 women), muscular density and white area index (WAI) which indicated structural characteristics of skeletal muscle were analyzed with gray scale analysis. The study examined correlations between subject's age and items which obtained from measuring ultrasound images and the differences in relations to sex and age. Muscular density and WAI had a high correlation with age and were significantly increased in men and women with greater age. The quantitative evaluation method of skeletal muscle structure which analyzed the ultrasound images has high practicality because it is a non-invasive method which complements physical therapy diagnosis and research methods and promotes functionality evaluation.

  • PDF

초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석 (Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images)

  • 천혜리;장현철
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.927-934
    • /
    • 2022
  • 본 연구는 간 초음파 영상을 활용하여 정량적인 측정 분석을 통해 조직 내 감쇠 지수, 조직 내 산란 분포지수 값 분석과 함께 초음파 영상 소견 간 일치도를 알아보고자 하였다. 2022년 8월부터 2022년 10월까지 지방간이 의심되어 간 초음파 검사 처방을 받은 45명의 환자를 대상으로 간 초음파 검사를 시행하였다. 연구결과, 초음파 영상 소견과 조직 내 감쇠 지수 간 일치도 분석 결과 Kappa 값이 0.82(p<0.05)로 두 검사 방법 간 매우 높은 일치도를 보였다. 또한, 초음파 영상 소견과 조직 내 산란 분포 지수 간 일치도 분석 결과에서도 Kappa 값이 0.642(p<0.05)로 두 검사 방법 간 높은 일치도를 보였다. 지방간 예측 시 간 초음파 소견 및 정량적인 초음파 검사 기법인 조직 내 감쇠 지수, 조직 내 산란 분포 지수를 활용한다면 지방간 환자의 진행 정도를 판단할 때 도움이 될 수 있을 것으로 생각된다.

정상 골격근의 근전도 중앙주파수 및 초음파 영상 밀도 분석 (Analysis of sEMG Median frequency and Ultrasound Image Echodensity of Normal Skeletal Muscle)

  • 정진규;김용남;황태연;이정우;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제18권1호
    • /
    • pp.83-94
    • /
    • 2006
  • Purpose: This study conducts quantitative evaluation or structural and functional characteristics or normal skeletal muscle with ultrasound image and surface electromyography, and is to provide basic materials for utilizing ultrasound image analysis in physical therapy diagnosis and assessment of skeletal muscle. Methods: Measurement of three stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age and gender were compared and correlations among measured items were analyzed and then the following conclusions were obtained. Results: Analysis of ultrasound image of normal skeletal muscle showed that density, median frequency had the closest relations with age. In addition, it was found that there were high correlations between density explaining structural characteristics of skeletal muscle and median frequency explaining functional characteristics. Conclusion: Analysis of ultrasound image makes complex evaluation of structure and function of skeletal muscle possible when it is connected with functional evaluation method using physical measurement surface electromyography as well as quantitative evaluation of structural changes of skeletal muscle and is effective in complementing physical therapy diagnosis centering around functionality evaluation.

  • PDF

위상 보상과 가중치 평균을 이용한 의료 초음파 신호의 주파수 특성 추출 방법 (Extraction Method of Ultrasound Spectral Information using Phase-Compensation and Weighted Averaging Techniques)

  • 김형석;이준환
    • 한국정보통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.959-966
    • /
    • 2010
  • 정량적 초음파 분석(Quantitative Ultrasound Analysis)은 반향된 초음파 신호의 짧은 시간 간격의 주파수 성분을 추출하여 개별 초음파 지수의 값을 예측한다. 따라서 반향 신호의 정확한 주파수 특성 추출은 분석의 정확도와 정밀도 향상에 기본이 된다. 본 논문에서는 초음파 지수의 정량적인 예측 및 분석에 이용할 수 있는, 짧은 시간 간격의 반향 신호의 주파수 특성 추출 방법을 제안한다. 제안된 알고리듬은 인접한 반향 초음파 신호간의 위상 차이를 보상하고, 동일 반향 깊이를 가지는 작은 영역의 신호를 가중치 평균함으로써 보다 정확한 주파수 특성을 추출한다. 컴퓨터 모의 실험을 통한 수치 분석 결과, 제안된 알고리듬은 일반적인 주파수 추출 알고리듬보다 정확한 예측 결과를 보였으며, 예측 결과의 정밀도도 10% 이상 향상되었다.

신체활동과 골초음파지표와의 연관성 (Association Between Physical Activity and Quantitative Ultrasound in a Rural Population)

  • 김승준;신민호;권순석
    • 한국전문물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.20-27
    • /
    • 2005
  • Osteoporosis is characterized by low bone mass and the microarchitectural deterioration of bone tissue with a consequent increase in bone fragility and susceptibility to fracture. It has been suggested that speed of sound (SOS) and broadband ultrasound attenuation (BUA) of quantitative ultrasound sonography (QUS) may provide information about not only bone density but also the microarchitecture and elastic properties of bone. Physical inactivity reduced mechanical usage and it made process to the bone changes. This study aimed to association between the physical activity and the QUS parameters in 1305 (593 men, 712 women) aged 20 years over in a rural population. Two QUS parameters, BUA (p=.23) and SOS(p=.73) were measured at the right calcaneus of postmenopausal women, no significant associations were observed between sports index and SOS and BUA. These results suggest that work, non-sports leisure physical activity (p<.01) have a significant influence on QUS parameters in a rural population. Physical activity are meaningful predictor of QUS parameters of the calcaneus in a rural population.

  • PDF

초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging)

  • 민정환;정회원;강혜경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.