• Title/Summary/Keyword: Quality testing

Search Result 1,876, Processing Time 0.025 seconds

Record keeping system of bugs for software quality assurance

  • Mateen, Ahmed;Zhu, Qingsheng;Afsar, Salman
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.207-213
    • /
    • 2019
  • Assistance for the quality assurance management and developers to provide high quality software products. Using a bug record keeping system is exceptionally important in software progress, and it is followed vastly by majority of software producing companies in modern era. Regular application of a bug record keeping system is very helpful in developing software systems. We developed this system which helps the software testing team to keep a complete record of their testing activities during the software testing, also increases your confidence in the software quality, class and worth. Our proposed system offers trouble-free and effortless approaches to acquire desired information about bug, also produces different kinds of reports like summary reports, detailed reports etc. It gives facility to create, delete and update any project. Our developed application system is designed by using visual c# at front end and sql server 2008 management studio express at back end.

Evaluation of Whole Effluent Toxicity (WET) Proficiency Testing for Water Quality Measurement Agencies in Korea (국내 수질측정대행업에 대한 생태독성 숙련도시험 평가)

  • Park, Woo Sang;Kim, Sang Hun
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.568-573
    • /
    • 2013
  • In this study, we conducted whole effluent toxicity (WET) proficiency testing based on the results which $EC_{50}$ value of 3 types (A, B, C) unknown samples calculated from 32 water quality measurement agencies in Korea. WET proficiency testing was expected to their improve of analysis skill and ensure reliability of analysis results. Ultimately, it is intended to promote the reliable enforcement of WET. WET proficiency testing was evaluated using the z-score, robust z-score and the results showed that 30 participating agencies were "compliance". In addition, $EC_{50}$ values of "unknown sample A" were the normal distribution. Therefore, "unknown sample A" was considered as the most suitable standard toxicity substance.

Guidelines for Manufacturing and Application of Organoids: Skin

  • Seunghee Lee;Yeri Alice Rim;Juryun Kim;Su Hyon Lee;Hye Jung Park;Hyounwoo Kim;Sun-Ju Ahn;Ji Hyeon Ju
    • International Journal of Stem Cells
    • /
    • v.17 no.2
    • /
    • pp.182-193
    • /
    • 2024
  • To address the limitations of animal testing, scientific research is increasingly focused on developing alternative testing methods. These alternative tests utilize cells or tissues derived from animals or humans for in vitro testing, as well as artificial tissues and organoids. In western countries, animal testing for cosmetics has been banned, leading to the adoption of artificial skin for toxicity evaluation, such as skin corrosion and irritation assessments. Standard guidelines for skin organoid technology becomes necessary to ensure consistent data and evaluation in replacing animal testing with in vitro methods. These guidelines encompass aspects such as cell sourcing, culture techniques, quality requirements and assessment, storage and preservation, and organoid-based assays.

Influences of Power Fluctuation on In-Situ Ground Thermal Response Testing (지중 열반응 현장시험에서 소비전력 변동의 영향)

  • Kim, Jin-Sang;Park, Keun-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.707-712
    • /
    • 2006
  • Knowing the ground thermal conductivity is very importnat in designing ground heat exchangers. Knowledge of the ground soil and rock composition information dose not guarantee the prediction of accurate thermal information. In Situ testing of ground heat exchangers is becoming popular. However, in situ testing are performed at construction sites in real life. Adequate data collection and analysis are not easy mainly due to poor power quality. Power fluctuation also causes the fluctuation of received data. The power quality must be maintained during the entire in situ testing processes. To accurately analyse the test data, the understanding of the response of the power fluctuation is essential. Testing under the power quality varied by tester is very difficult. Analyzing power variation by numerical simulation is a realistic option. By varying power in a sinosuidal manner, its effects on predicting thermal conductivity from thermal response plots made from the test data are examined.

  • PDF

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.

Expression of Codon Optimized β2-Adrenergic Receptor in Sf9 Insect Cells for Multianalyte Detection of β-Agonist Residues in Pork

  • Liu, Yuan;Wang, Jian;Liu, Yang;Yang, Liting;Zhu, Xuran;Wang, Wei;Zhang, Jiaxiao;Wei, Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.9
    • /
    • pp.1470-1477
    • /
    • 2019
  • ${\beta}_2$-adrenergic receptor (${\beta}_2-AR$) was expressed efficiently using Bac-to-Bac Baculovirus Expression System in Sf9 cells as a bio-recognition element for multianalyte screening of ${\beta}$-agonist residues in pork. Sf9 cells were selected as the expression system, and codon optimization of wild-type nucleic acid sequence and time-dependent screening of expression conditions were then carried out for enhancing expression level and biological activity. Under optimum conditions of multiplicity of infection (MOI) = 5 and 48 h post transfection, the protein yield was up to 1.23 mg/ml. After purification by chromatographic techniques, the purified recombinant protein was applied to develop a direct competitive enzyme-linked receptor assay (ELRA) and the efficiency and reliability of the assay was determined. The IC50 values of clenbuterol, salbutamol, and ractopamine were 28.36, 50.70, and $59.57{\mu}g/l$, and clenbuterol showed 47.61% and 55.94% cross-reactivities with ractopamine and salbutamol, respectively. The limit of detection (LOD) was $3.2{\mu}g/l$ and the relevant recoveries in pork samples were in the range of 73.0-91.2%, 69.4-84.6%, and 63.7-80.2%, respectively. The results showed that it had better performance compared with other present nonradioactive receptorbased assays, indicating that the genetically modified ${\beta}_2-AR$ would have great application potential in detection of ${\beta}$-agonist residues.

A Learning Experience from ISTO Examination

  • Croft, Nigel;Park, Young-Hyun
    • International Journal of Quality Innovation
    • /
    • v.2 no.2
    • /
    • pp.145-150
    • /
    • 2001
  • The revised ISO9000 family of standards represents a significant improvement on the 1994 version and, if implemented well within organizations, should facilitate the development of effective, process-oriented Quality Management Systems. This paper describes how the International Standardized Testing Organization (ISTO) tests the understanding of ISO9000 : 2000, and presents an analysis of the results of the first examinations held in the UK, USA, Mexico and Hong Kong, in February and March 2001.

  • PDF

Quality Assurance Experience in Korea

  • Lee, Jone-Chan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.1
    • /
    • pp.23-29
    • /
    • 1984
  • This paper describes the evolution of quality assurance in Korea from it's total reliance on foreign contractors to the present status of conducting all QA functions independently. A brief status of the Republic of Korea Regulatory Bodies, licensing precess, codes and standards, and the quality organization of the Korea Electric Power Corporation are also included.

  • PDF

A Case on TMS(Threat Management System) BMT Software Separated Acquisition (위협관리시스템(TMS) 소프트웨어 분리발주 BMT 사례)

  • Sang-Bok Lee;Hang-Sin Kwak;Seok-Kyoo Shin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.11a
    • /
    • pp.496-499
    • /
    • 2008
  • 공공부분 S/W사업은 분리발주가 원칙이고 일괄발주가 예외지만 현재 많은 공공부분 S/W사업은 일괄 발주 사업으로 진행되고 있다. 일괄발주는 SI업체가 S/W업체도 선택하여 입찰 및 개발하기 때문에 발주자가 원하는 품질 좋은 S/W를 선택할 수 없고, 발주자가 S/W를 업그레이드 및 확장할 때 SI업체에 의존하게 되는 단점이 있다. 이런 단점을 보완하고, S/W분리발주를 활성화시키기 위해 지식경제부(구 정보통신부)에서는 S/W분리발주 매뉴얼을 작성하여 보급 및 교육을 하고 있으며, 발주처에서는 품질이 우수한 S/W를 선택하기 위한 S/W분리발주 BMT를 공인된 시험기관인 한국정보통신기술협회(TTA) SW 시험인증센터에서 BMT를 실시하고 있다. 본 논문은 위협관리시스템(TMS) S/W분리발주 BMT를 공인된 국가 시험인증기관인 한국정보통신기술협회(TTA) SW시험인증센터에서 수행한 사례를 기술하였다

Measurement and Testing System (측정 및 시험시스템(M&TS))

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.11a
    • /
    • pp.382-388
    • /
    • 2005
  • This paper has briefly explained the various measurement and testing system which is an Important component of modern quality and process improvement activities. This paper deals with precision and force measurement , NDT, and MSA.

  • PDF