• 제목/요약/키워드: Quality test

검색결과 11,115건 처리시간 0.04초

회전익 항공기 장축 조종로드 분할 형상의 품질 신뢰성에 관한 실증적 연구 (An Empirical Study on the Quality Reliability of the Split Shape of Long Control Rod for the Rotorcraft)

  • 임현규;김만태;최재형;김대한;장민욱;윤재휘
    • 품질경영학회지
    • /
    • 제45권3호
    • /
    • pp.365-377
    • /
    • 2017
  • Purpose: In the A rotorcraft, the division of a long yaw control rod was studied to improve the heat treatment capability. The purpose of this study was to analyze whether division of yaw control rod affects quality reliability in the A rotorcraft and analyze whether it secured flight safety. Methods: The structural static test and the vibration durability test on the split shape of yaw control rod were carried out in order to examine and verify the existing structural analysis results. Results: Structural static test results showed that there were no cracks and vibration durability test results showed that there was no damage or breakage on the split yaw control rod. Conclusion: This study showed that the quality reliability was confirmed and thus the flight safety of the A rotorcraft was secured. And it is expected that the split technique of the yaw control rod will contribute to the development of the rotorcraft industry in the future.

소프트웨어 품질 향상을 위한 테스트 자동화 도구에 관한 동향분석 (Review of S/W Test Automation Tools for the Improvement of the Software Quality)

  • 정승환;이금석;김종기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1477-1478
    • /
    • 2004
  • Science the change of development methods and environment of the software is rapidly kept going in industry, previous manual test methods will not be able to guarantee the quality of software. Therefore the software test automation tools is being developed actively. And many of the tools which is reliable is applied and used in domestic organizations. Indirect test techniques currently are used For the improvement of the software quality, such as formal specification and design, structural programming. And also the various do direct test techniques are used to the measurement of software quality through the fault detection and modification, such as black box, which box and test automation tools. In this survey, the software test automation tools which predicate and access the software quality at the software development phase for the improvement of the software quality should be introduced.

  • PDF

수질변화의 계량화를 위한 비모수적 통계 준거에 관한 연구 (A Study of Non-parametric Statistical Tests to Quantify the Change of Water Quality)

  • 이상훈
    • 환경영향평가
    • /
    • 제6권1호
    • /
    • pp.111-119
    • /
    • 1997
  • This study was carried out to suggest the best statistical test which may be used to quantify the change of water quality between two groups. Traditional t-test may not be used in cases where the normality of underlying population distribution is not assured. Three non-parametric tests which are based on the relative order of the measurements, were studied to find out the applicability in water quality data analysis. The sign test is based on the sign of the deviation of the measurement from the median value, and the binomial distribution table is used. The signed rank test utilizes not only the sign but also the magnitude of the deviation. The Wilcoxon rank-sum test which is basically same as Mann-Whitney test, tests the mean difference between two independent samples which may have missing data. Among the three non-parametric tests studied, the singed rank test was found out to be applicable in the quantification of the change of water quality between two samples.

  • PDF

Investigation About Quality Control of General X-ray System

  • Kang, Byung-Sam;Son, Jin-Hyun;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.157-164
    • /
    • 2011
  • This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

  • PDF

순열검정을 이용한 품질의 집의 일관성 검정 (Consistency Test in the House of Quality using Permutation Test)

  • 김경미
    • 대한산업공학회지
    • /
    • 제34권1호
    • /
    • pp.42-48
    • /
    • 2008
  • The house of quality (HOQ) involves subjective and ambiguous information typically through a likert scale, It isimportant to validate consistency of such input in the HOQ before rating the fmal importance of technicalrequirements, Previously, a methodology was developed to test the consistency of relationship strengths in theHOQ between roof matrix and relationship matrix. We described disadvantages of the previous method andpropose a new approach based on the permutation test. Advantages of the proposed method are illustrated withan example.

고기능성 투습방수 소재의 저온굴곡 시험방법 개선 연구 (A Study on Improvement of the low temperature flex resistance test method about high waterproof materials)

  • 이민희;문선정;고혜지;홍성돈
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.425-440
    • /
    • 2018
  • Purpose: This study is aimed at developing of the flex resistance testing process at low temperature with the waterproof fabric to suit the military environment, and is designed to fit for the purpose of the waterproof materials in order to optimize the test method by finding out matters to improve from existing the test method and through previous studies. Methods: The test method, which has been applied to flex resistance of existing water-repellent materials, was improved and consequently, differentiated test results could be obtained according to the test temperature, sample size, and flexing method. Results: The testing of the total of 8 samples revealed that performance of the military requirement could hardly be met just by presenting the materials or 2~3 layers when the quality criteria for high functional water repellent fabrics were applied. PTFE(Polytetrafluoroethylene) is preferred to PU(Polyurethane) to be used in the extremely low-temperature environment, but durability under the low-temperature environment may be varied depending on film thickness or laminating technique even if the materials of waterproof films are identical. Therefore, in addition to the material or texture, the test method capable of reflecting durability under the low-temperature environment shall be suggested, and the newly designed test method proposed in this study was shown to suggest differentiated quality criteria by the material. Conclusion: The water resistance measurement and the test method following flex resistance with expanded range of flex will enable the differentiable test of the samples according to the number of repetition. This study is meaningful in that it suggests a differentiable test method capable of establishing a basis of deciding suitable material when selecting military goods made of water repellent material by properly improving the test method.

한국형 기동헬기 꼬리 날개 디페인팅 현상을 통한 도장 품질 향상에 관한 연구 (A study on improvement of painting quality through a de-painting phenomenon of KUH-1 tail blade)

  • 장인기;김영진;서현수;전부일
    • 품질경영학회지
    • /
    • 제42권3호
    • /
    • pp.325-338
    • /
    • 2014
  • Purpose: The purpose of this study was to explain de-painting phenomenon of KUH-1 tail blade and to propose useful solution of it by test. The proposed solution was evaluated by real flight, and then it applied to mass product to improve the paint qual ity of KUH-1 tail blade. Methods: This study investigated an adhesive ability of primer following surface sanding condition. The cross cut and scratch test were conducted to evaluate the adhesive strength. And the water flow test was designed to simulate a real flight condition under rain. Through water flow test, an optimal condition of tail blade to prevent a de-painting phenomenon was deduced. Finally, the improvement method was evaluated by real flight under rain. Results: The results of this study are as follows; The sequential polishing was most excellent method in primer painting quality. The results of test including cross cut, scratch and water flow showed that MIL-DTL-53039 paint with epoxy primer has excellent adhesive ability. To proof the effect of improvement, a real flight during a rain condition was conducted. Finally, the comparison between original and improved configuration was conducted. Conclusion: The painting quality of KUH-1 tail blade was improved through deriving an optimal painting condition. In detail, a condition of optimal sanding and a sort of primer and paint was showed. Finally, the reliability of tail blade was guaranteed through improving the quality of painting.

자동차용 유해가스 검출기의 신뢰성 평가기준 (Reliability Assessment Criteria of Air Quality System)

  • 최만엽;박동규;오근태;정해성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제10권4호
    • /
    • pp.279-297
    • /
    • 2010
  • AQS(Air Quality Control System) is the important part of a car air conditioning system. This device intercepts automatically the influx of harmful waste gas. In this paper reliability assessment criteria for AQS are established in terms of quality certification test and lifetime test. The former quality certification test comprises general performance test and environmental test. Items which pass the test undergo lifetime test which guarantees the extent of mean lifetime with certain confidence.

차량 드로틀 보디 전장부품의 품질관리 성능시험 알고리즘 개발 (Development of Algorithm of Surge Test for Quality Control on Electrical Parts of Throttle Body in Automobiles)

  • 손재환;김태한
    • 한국산업융합학회 논문집
    • /
    • 제9권1호
    • /
    • pp.67-72
    • /
    • 2006
  • This study is on the development of algorithm of surge test for quality control on electrical parts of throttle body in automobiles with internal combustion engine, not only to know its condition to be good or not, but also jugding its condition to be classified into six types. To know whether its condition to be good or not, comparing and analyzing between two waveforms generated from master and test coil of throttle body. If test net area is below 20% of master area, the condition of test coil is good. By analyzing test coil waveform to master coil waveform, the condition of test coil into winding badness, insulation badness, layer and corona discharge, short badness should known. Therefore quality control system on electrical parts of throttle body should be developed.

  • PDF

Evaluation Criteria of Reliability on Transmission Control Unit for Passenger Car

  • Choi, M.;Ryu, S.;Lim, J.H.;Jeong, H.S.
    • International Journal of Reliability and Applications
    • /
    • 제11권1호
    • /
    • pp.55-67
    • /
    • 2010
  • There has been a recent upsurge in demand for the improvement of car reliability in the Northern American which is the primary market of South Korea automobile industry. It has been required that the warranty for transmission control unit for passenger cars directly related to passenger safety or security should be extended for 10 years and 160,000 km. In this paper, the test method for reliability and evaluation criteria is presented to evaluate the reliability on the automatic transmission controller. Reliability certification test can be roughly divided into two types: a quality test and life assessment test and a quality test can be subdivided into a basic performance test and environmental resistance test. There are 3 types of tests on the performance test for automatic transmission controller and environmental resistance test is composed of 14 items. Life test is performed with only the product passed this quality test. In this study, operation limit test at the high-temperatures, accelerated life test under specific temperature and accelerated life test for 2 or 3 stress levels are shown as a way for life test.

  • PDF