• Title/Summary/Keyword: Quality monitoring

Search Result 3,343, Processing Time 0.028 seconds

The Systematic Management for Trace Hazard Compounds in Drinking Water (수돗물에서 미량유해물질의 체계적 관리방안 연구)

  • Park, Sun-Ku;Rim, Yeon-Taek
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.431-441
    • /
    • 2005
  • The study was carried out to improve and regulate the drinking water quality standard and drinking water quality monitoring substances. For the reliability and safety of finished water, It has been monitored for trace organic and inorganic compounds of 333 in finished water of water treatment plants during 1989 to 2003. As a result of monitoring, 51 compounds were detected from 333 compounds, and it has been regulated the drinking water quality standard of 26 substances and 20 mitoring substance. Improvement and regulation method of the drinking water quality standard was performed by comparing and analyzing with detection concentration, detection frequency, risk assessment and foreign drinking water quality standard.

Evaluation of Quality Management of Domestic Asbestos Survey and Monitoring Service Providers (국내 석면조사기관의 품질관리 수준에 대한 평가)

  • Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • Objectives: The aim of this study is to evaluate the quality management systems of domestic asbestos survey and monitoring service providers and the relationships with the number of licenses or designations and sales performances. Methods: Data on quality management systems were collected by assessors who were assigned by the Korea Occupational Safety and Health Agency(KOSHA) during a pilot evaluation program for designated asbestos survey and monitoring service providers in 2016 using evaluation criteria developed by KOSHA. Basic characteristics, evaluated scores, and sales performance were gathered and statistically analyzed. Results: The median and arithmetic mean of the total scores were 0.64 and 0.66. Evaluation fields that scored highly with the highest percentages were sales performance, installation and availability of equipment, compliance with the mandatory minimum number of airborne samples, laboratory independence, and results of proficiency analytical testing, in that order. Evaluation fields that received low marks with the highest percentages were the training of personnel, blank field samples, calibration of flow rates, preliminary check and visual inspection of the work area prior to the clearance test, and review and approval of final reports, in that order. Comparison of normalized scores between service providers registered for asbestos and other tasks and those designated for only asbestos showed significant differences in their evaluated scores. Sales performance did not show a positive correlation with evaluated scores. Conclusions: The quality management systems of domestic asbestos survey and monitoring service providers were poor. High scores were recorded mostly in evaluation fields related to regulatory requirements. Low scores were recorded mostly in evaluation fields related to documentation and recordkeeping. Considering the low influence of quality on sales performance, the government needs to evaluate the quality management of asbestos survey and monitoring service providers and provide the results to public in order to address their low levels of quality management.

Low-Cost Remote Power-Quality-Failure Monitoring System using Android APP and MCU (안드로이드 앱과 MCU를 이용한 저가형 원격 전원품질이상 감시 시스템)

  • Lim, Ho-Kyoun;Kim, Seo-Hwi;Lee, Seung-Hyeon;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.144-155
    • /
    • 2013
  • This paper presents a low-cost remote power-quality-failure monitoring system (RPMS) using Android App and TI MCU (micro-controller unit), which is appliable to a micro-grid. The designed RPMS testbed consists of smart nodes, a server, and Android APPs. Especially, the C2000-series MCU-based RPMS smart node that is low-cost compared to existing monitoring systems has both a signal processing function for power signal processing and a data transmission function for power-quality monitoring data transmission. The signal processing function implements both a wavelet-based power failure detection algorithm including sag, swell, and interruption, and a FFT-based power failure detection algorithm including harmonics such that reliable and real-time power quality monitoring is guaranteed. The data transmission function implements a low-complexity RPMS transmission protocol and defines a simple data format (msg_Diag) for power monitoring message transmission. We may watch the monitoring data in real time both at a server and Android phone Apps connected to the WiFi network (or WAN). We use RS-232 (or Bluetooth) as the wired (or wireless) communication media between a server and nodes. We program the RPMS power-quality-failure monitoring algorithm using C language in the CCS (Code Composer Studio) 3.3 environment.

Using Protective Relaying for Power Quality Monitoring (보호계전기를 이용한 전기품질 감시 기법 연구)

  • Bea, Y.J.;Lim, S.I.;Choi, I.S.;Lee, S.J.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.62-64
    • /
    • 2002
  • Power quality monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. Therefore, this paper is proposed to use digital protective relays for power quality monitoring. In addition, taking power quality events, Electrical magnetic phenomenon of IEEE std 1159, proposing that adaptive power quality event list consider limitation memory capacity and signal processing ability of protective relay. The prototype S/W of power quality analysis is also developed. Especially this prototype S/W analysis scheme is verified through many kinds of power quality events (gathering protective relay data) in EMTP simulation.

  • PDF

Evaluation of Status of Groundwater Quality Monitoring Network of Korea : Implications for Improvement (우리나라 지하수수질측정망 현황 평가 및 개선을 위한 고찰)

  • Park, Joung-Ku;Kim, Rak-Hyeon;Lee, Jin-Yong;Choi, Dong-Hyuk;Kim, Tae-Dong
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.92-99
    • /
    • 2007
  • As of 2007, there are 2,499 groundwater quality monitoring stations in total in Korea. Among them,478 are operated by the MOCT (Ministry of Construction and Transportation) for the National Groundwater Network Program, 781 wells by the ME (Ministry of Environment) for monitoring of the area where imminent contamination is expected, and 1240 wells by the local governments for monitoring of other areas. Even though, water quality data obtained from those wells are being provided to the public since 1999, the information for the wells has not been appropriately informed. In this study, we assessed the wells that are being used for the national groundwater quality monitoring from the points of operation, location, and well configuration to provide suggestions for the improvement of the national groundwater quality monitoring.

Development of Power Quality Monitoring System(PQMS) : Database Design for PQMS (전력품질 감시 시스템 개발(1): 전력품질 데이터베이스 설계)

  • Kim, Young-Il;Bahng, Soon-Jung;Han, Jin-Hee;Yun, Tae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.128-130
    • /
    • 2003
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and power market being formed according to the reorganization of the power market, power providers and consumers show much interest in the power quality problem. This situation makes the demand creation of integrated system for power quality analysis and monitoring based on speedy and powerful functions by the growth of computer hardware and information technology, and besides advanced corporation already have created and employed power quality analysis and monitoring system. In this papers, it will be introduced that power quality database design-database is essential to integrated system-for managing effectively and confidently data from the power quality meters(PQM).

  • PDF

A web-based power quality monitoring system in the Substation Automation System (변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템)

  • Park D. H.;Lim S. J.;Shin J. H.;Lim S. I.;Lee S. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF

A Scalable Wireless Body Area Network for Bio-Telemetry

  • Saeed, Adnan;Faezipour, Miad;Nourani, Mehrdad;Banerjee, Subhash;Lee, Gil;Gupta, Gopal;Tamil, Lakshman
    • Journal of Information Processing Systems
    • /
    • v.5 no.2
    • /
    • pp.77-86
    • /
    • 2009
  • In this paper, we propose a framework for the real-time monitoring of wireless biosensors. This is a scalable platform that requires minimum human interaction during set-up and monitoring. Its main components include a biosensor, a smart gateway to automatically set up the body area network, a mechanism for delivering data to an Internet monitoring server, and automatic data collection, profiling and feature extraction from bio-potentials. Such a system could increase the quality of life and significantly lower healthcare costs for everyone in general, and for the elderly and those with disabilities in particular.

Factors Affecting Quality of Internal Control: A Case Study of Listed Banks in Vietnam

  • TRAN, Quoc Thinh;NGUYEN, Khanh Tuan;LE, Xuan Thuy
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.5
    • /
    • pp.375-380
    • /
    • 2021
  • Internal control is important for monitoring operations of organizations. In order to achieve the quality of internal control, organizations need to recognize different perspectives in which the components of internal control play a decisive role. Internal control is a process designed by the manager and it is applied within the organization to provide reasonable assurance of the reliability of financial information and to comply with policies, procedures, rules, regulations and laws. The article uses the ordinary least squares method and the seven-point Likert scale to test the variables affecting the quality of internal control in 18 Vietnamese listed banks. The article surveyed 179 leaders of listed banks. The results show that there are three variables out of a total of five variables that positively affect the quality of internal control, including the control environment, control activities, and monitoring. Accordingly, the managers of Vietnamese listed banks need to pay attention to building a corporate culture environment, improve the quality of control activities, and periodically and regularly conduct the monitoring. It contributes to improving the quality of internal control and is also an opportunity to increase economic benefits for Vietnamese listed banks in the context of international economic integration.

Query-based Indoor air Quality monitoring system Using wireless sensor network inside the Building (빌딩내에서 무선센서네트워크를 이용하는 쿼리기반의 실내공기 질 모니터링시스템)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.627-628
    • /
    • 2008
  • This paper proposes an indoor air Quality monitoring system for measuring various indoor air qualities using IEEE 802.15.4 based wireless sensor network. For indoor air quality monitoring, sensor nodes include carbon monoxide sensor and dust sensor were used. The wireless network by deployed sensor nodes has limited energy, computing, communication capabilities and memory sizes. In this paper, the query process in indoor air quality monitoring was designed to improve the limited sensor node resources such as battery consumption and networking.

  • PDF