• Title/Summary/Keyword: Quality monitoring

Search Result 3,357, Processing Time 0.035 seconds

MEMS/Nano-technologies for Smart Air Environmental Monitoring Sensors

  • Park, Inkyu;Yang, Daejong;Kang, Kyungnam
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.281-286
    • /
    • 2015
  • The importance of air quality monitoring is rapidly increasing. Even though state-of-the-art air quality monitoring technologies such as mass spectrometry, gas chromatography, and optical measurement enable high-fidelity measurement of air pollutants, they cannot be widely used for portable or personalized platforms because of their high cost and complexity. Recently, personalized and localized environmental monitoring, rather than global and averaged environmental monitoring, has drawn greater attention with the advancement of mobile telecommunication technologies. Here, micro- and nano-technologies enable highly integrated and ultra-compact sensors to meet the needs of personalized environmental monitoring. In this paper, several examples of MEMS-based gas sensors for compact and personalized air quality monitoring are explained. Additionally, the principles and usage of functional nanomaterials are discussed for highly sensitive and selective gas sensors.

Assessment of Groundwater Quality on a Watershed Scale by Using Groundwater Quality Monitoring Data (지하수수질측정망 자료를 이용한 유역단위 지하수 수질등급 평가)

  • Kim, Jeong Jik;Hyun, Yunjung
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.186-195
    • /
    • 2021
  • In Korea, groundwater quality is monitored through National Groundwater Quality Monitoring Network (NGQMN) administered by Ministry of Environment. For a given contaminant, compliance to groundwater quality standards is assessed on a annual basis by monitoring the number of incidents that concentration exceeds the regulatory limit. However, this approach provides only a fractional information about groundwater quality degradation, and more crucial information such as location and severity of the contamination cannot be obtained. For better groundwater quality management on a watershed, a more spatially informative and intuitive method is required. This study presents two statistical methods to convert point-wise monitoring data into information on groundwater quality status of a watershed by using a proposed grading scale. The proposed grading system is based on readily available reference standards that classify the water quality into 4 grades. The methods were evaluated with NO3-, Cl-, and total coliform data in Geum River basin. The analyses revealed that groundwater in most watersheds of Geum River basin is good for domestic or/and drinking with no treatment. But, there was notable quality degradation in Bunam seawall and So-oak downstream standard watersheds contaminated by NO3- and Cl-, respectively.

A Real Time Monitoring for Water Quality of River (수질자동모니터링시스템의 설치 현황과 전망)

  • Ryu, Jae-Kuen
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Water quality is monitored at 1,837 points which are streams and sources for water supply in Karea. The monitoring carry out the measurement of 16 parameters of pH, BOD, SS, DO and so on with once a month, and of other parameters such like heavy metal with once a quarter. But most of the monitoring is carried out uncontinuously, so it is very difficult to understand exactly the changes of water quality compared with continuous monitoring. Therefore, real time monitoring system was equipped with basic parameters such as pH, temperature, DO, turbidity and electric conductivity at 25 major sources of water supply after installation of Noryangjin and Dukdo in 1974. But the systems have some problems which cannot be considered the sampling sites to represent for water quality of stream of lake, and can be caused a change of water quality by long distance from analyzer to intake pipe. Therefore, it has carefully to evaluate selection of sample sites for real time monitoring system. Also, problems on the area has been to identify which parameters are best suited to monitoring stream of lake water and the differences, of analyzing results compared with manual analyzing. This paper presents some approaches to handle such problems, namely selection of sampling site and measurable parameters, to connect with bio-monitoring system solving a Limitation of measurable parameters, The bio-monitoring system of an early alarm that is desirable to perceive a toxic material inflow into stream can be applied to continuos water quality monitoring system effectively. Also, this paper presents to build a on line system transmitting immediately from a mobile analyzer house or container to main monitoring center the results of analyzer by a telemeter.

The Study on the Integrated Monitoring of Water Quantity and Quality Data (수량 및 수질관측 통합연계 운영 연구)

  • Yi, Jae-Eung;Kim, Mun-Mo;Park, Sung-Je
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.115-123
    • /
    • 2009
  • Integrated information to water quantity and quality is essential for planning water resources management as well as operating water-related infrastructures. Because data collection process including monitoring and maintenance is separated in different governmental agencies in Korea, integrating quantity and quality may provide effective and better management implementation. In this study, a number of suggestions regarding integration of water monitoring were concluded in terms of technological, legal and institutional implications. First, it is necessary to discuss national water monitoring plan, national water information management plan, agreement of standard terms of monitoring between ministries, and to revise the law(river law and water quality management law). Present stations for water monitoring should be used for both of quantity and quality monitoring. If station is newly installed or relocated, it is better that one single agency maintain monitoring frequency and data management as well. In addition, a monitoring protocol need to be agreed by each of parties. In order to develop integrated monitoring system, quality assurance of the collected data should be properly maintained. Since many purposes haven been concerned using of data analysis and assessment so far, it may not be easy to integrate water quantity and quality monitoring in a short period. However, the alternatives including enhancing institutional regulations and programs, advanced technology may promote an efficient integrated water monitoring.

수질 장기관측자료를 활용한 우리나라의 지하수 수질변동 특성

  • 김규범;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.94-96
    • /
    • 2003
  • Since 1995, MOCT(Ministry of Construction and Transportation) and KOWACO(Korea Water Resources Corporation) have established the National Groundwater Monitoring Network in South Korea and also MOE(Ministry of Environment) has operated Groundwater Quality Monitoring network. Until 2001, 202 monitoring stations by MOCT and 780 monitoring wells by MOE have been constructed, measured groundwater level and analyzed water samples. Groundwater quality analysis has been conducted two times a year during last 6 years for all monitoring wells. The quality data has about 15 components including pH, COD, Count of Coliform group, and etc.. Trend analysis has been peformed for 6 components(Coliform, pH, COD, NO$_3$-N, Cl and EC) of water quality which are analyzed more than 7 times for total monitoring wells. Two test methods have been used ; Sen's test and Mann-Kendall test. These trend tests have been done at the 0.05 significance level. By the result of Sen's test, Count of Coliform group has either upward or downward trends at 4.3 percent of the monitoring points. pH does at 5.6 percent, COD does at 8.6 percent, Nitrate-Nitrogen does at 13.2 percent, Chloride does at 13.4 percent, and. EC does at 11.6 percent of the monitoring points. The exact causes of the groundwater quality trends are difficult to specify. Notable downward trends in nitrate at many monitoring points may be the result of reduction on some contamination sources. Potential causes include diminished agricultural areas, improvements in sewage treatment and a decrease in atmospheric deposition. Increase in chloride at many monitoring points may be the result of increased non-point source pollution such as road salting and runoff from sprawling paved developments and suburbs.

  • PDF

Monitoring and Analysis of Nutrients in Sediments in the Riverbed (하천 퇴적물의 영양염류 모니터링)

  • Kim, Geonha;Jung, Woohyeok;Lee, Junbae
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.838-845
    • /
    • 2006
  • Characterization of sediment in the riverbed is of importance for effective water quality management, yet have not been monitored sufficiently. This paper reports monitoring results of nutrient concentrations of sediments. Surface waters and sediments were sampled four times during rainy season at five monitoring points. Organics of overlying water were increased after high flow condition followed by decreasing tendencies. Soluble phosphorus fraction among total phosphorus was increased after high flow condition while total phosphorus was in decreasing tendencies. Monitoring result suggested that more extended monitoring scheme for flow rate, scouring velocity, and suspended material is required for analyzing relationship between water quality and sediment.

Applications of Drones for Environmental Monitoring of Pollutant-Emitting Facilities

  • Son, Seung Woo;Yu, Jae Jin;Kim, Dong Woo;Park, Hyun Su;Yoon, Jeong Ho
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.2 no.4
    • /
    • pp.298-304
    • /
    • 2021
  • This study aimed to determine the applicability of drones and air quality sensors in environmental monitoring of air pollutant emissions by developing and testing two new methods. The first method used orthoimagery for precise monitoring of pollutant-emitting facilities. The second method used atmospheric sensors for monitoring air pollutants in emissions. Results showed that ground sample distance could be established within 5 cm during the creation of orthoimagery for monitoring emissions, which allowed for detailed examination of facilities with naked eyes. For air quality monitoring, drones were flown on a fixed course and measured the air quality in point units, thus enabling mapping of air quality through spatial analysis. Sensors that could measure various substances were used during this process. Data on particulate matter were compared with data from the National Air Pollution Measurement Network to determine its future potential to leverage. However, technical development and applications for environmental monitoring of pollution-emitting facilities are still in their early stages. They could be limited by meteorological conditions and sensitivity of the sensor technology. This research is expected to provide guidelines for environmental monitoring of pollutant-emitting facilities using drones.

Problems and Improvements in the Quality Control of the Air Monitoring Network (대기오염측정망 정도관리의 문제점과 개선방향)

  • Kim, Duck-Sung;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

The Effect of Self-Monitoring, Pioneer Brand Awareness, Types of Endorsers on Quality Perception of Me-Too Brands - Focused on Outdoor Brand - (자기감시성, 선발브랜드의 인지도, 광고모델 유형이 미투 브랜드의 품질지각에 미치는 영향 -아웃도어 브랜드를 중심으로-)

  • Jung, Seung Yeon;Hwang, Sun Jin
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.8
    • /
    • pp.22-34
    • /
    • 2015
  • This study was intended to investigate the influences of consumer's self-monitoring, pioneer brand awareness, types of endorsers on quality perception of "me-too" brands with a focus on outdoor brands. The design of this research was comprised of 2 types of self-monitoring(high vs. low), 2 types of pioneer brand awareness(high vs. low), 2 types of endorsers(professional expert vs. typical consumer). The study was carried out by using samples from residents of Seoul and Gyeonggi area. The number of subjects used in the final analysis totaled 243, with age of the consumers ranging grom 20's to 50's. The results of this study were as follows. Self-monitoring, pioneer brand awareness and types of endorsers had shown a statistically significant correlation effect on the quality perception of me-too brands. Especially, in the high-level self-monitoring group, the effect of pioneer brand awareness on quality perception of me-too brand was significant when typical consumer model was given. The result presents that using a professional expert model in the market rather than a typical consumer model can offset the quality perception of pioneer brand with low awareness.

Object-oriented Design for Water Quality Monitoring Networks in the Han River System (한강수계 수질측정망 개선을 위한 목적 지향 설계 방안에 관한 연구)

  • Wang, Soo-Kyun;Na, Eun-Hye;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.453-460
    • /
    • 2005
  • Since late 1970s, water quality monitoring had been performed in Korea by various agencies according to their own needs and objectives. Lacking of consistency in principles, such diverse operation has been producing difficulties in management of information on water quality parameters. These difficulties resulted from the fact that the expansion of monitoring networks had been based not on systematic methodology with considerations on scientifically established planning objectives but on personal experiences and subjective judgments in locating monitoring stations. This study aimed, therefore, to develop a selection methodology for locating monitoring stations to provide various informations on water quality to satisfy various monitoring objectives such as understanding short and long term trends of water quality, monitoring violations to water quality standards, identifying external causes and sources affecting water quality changes, supporting utilization of water resources, examining short-term variations in water quality through a concentrated investigation, estimating pollution loads from each unit watershed, supporting water quality modeling, and establishing informative systems for water resources management. Also, we applied the proposed methodology and presented an improved expansion plan for water quality monitoring networks in the Han River.