• Title/Summary/Keyword: Quality engineering

Search Result 20,572, Processing Time 0.05 seconds

A Study on the Static Behaviors of Steel Deck Plates of Skew Bridges (사교(斜橋)의 강상판(鋼床板)의 정적거동(靜的擧動)에 대한 연구(研究))

  • Yang, Chang Hyun;Oh, Gi Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.815-826
    • /
    • 1994
  • Skew bridges are found frequently in new bridge construction due to geographical conditions when new constructing bridges are put across the existing highways, railroads or rivers. This study is to investigate the static behaviors of the steel deck plates of skew bridges which are increasingly used in bridges due to outstanding quality of structural steels, development of welding techniques, in order to reduce dead loads and period of constructions. The static behaviours of steel deck plates are analyzed using general purpose FE code SAP90 by modeling the skewed deck plates with rigorous finite elements, as the skew angles vary. The results of finite element analysis for the behaviors of steel deck plates and concrete slabs in acute, obtuse corners and center of decks are compared and discussed as the skew angles vary from $90^{\circ}$ to $30^{\circ}$. Two types of decks are treated, as isotropic plates and orthotropic plates, respectively. From the results of finite element analysis, it is found that more moments, reactions, and deflections occur at the obtuse corners than at the center of skewed decks regardless of isotropy or orthotropy. Especially, in case of the skewed deck plates with skew angles less than 45 degrees, significantly large discrepancies for the values of those internal forces are shown between the skewed and right deck plates. This study estimates the characteristics of deck behaviors according to skew angles, and proposes limitations of skew angles and the ciritical regions of decks.

  • PDF

Changgyeongwon Ya-Aeng as Modern Urban Culture - An Interpretation based on Benjamin's Phantasmagoria - (근대 도시 문화로서 창경원 야앵 - 벤야민의 '판타스마고리아'를 중심으로 -)

  • Kwon, Young-Ran;Pae, Jeong-Hann
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.1
    • /
    • pp.61-71
    • /
    • 2018
  • This study sought to interpret the Ya-Aeng (夜櫻) from the viewpoint of urban society, focusing on the occurrence of the Ya-Aeng at Changgyeongwon (昌慶苑) in the modern city of Kyungsung. When the Ya-Aeng started in the 1920s, the social aspects of Kyungsung were in a transitional period from the traditional to the modern. The social modernization of Kyungsung has had a dramatic impact on the Ya-Aeng as a part of the city culture. Using the concept of 'phantasmagoria', which was widespread in Kyungsung society and the Ya-Aeng, this study has established three implications of the Ya-Aeng. First, Kyungsung's phantasmagoria appeared in the form of crowds, spectacles, and experiences. This study suggests that such interpretation also applies to the Ya-Aeng. This means that the capitalism-controlled modern society on one hand and the Ya-Aeng on the other had the same mechanism. Therefore, the Ya-Aeng, as modern city culture, becomes a miniature version of Kyungsung and a modern commodity world in itself. Second, the fact that phantasmagoria is a major element of the landscape of the Ya-Aeng means that there is a special way of seeing. For modern subjects, the phantasmagoria of the Ya-Aeng has acted as a learning mechanism for a modern way of seeing. Third and finally, the phantasmagoria of the Ya-Aeng was an illusion to encourage the continued consumption of this culture and at the same time, forget about the capitalism-controlled urban culture. At this time, capitalism was dominated by the influence of Japanese imperialism. The significance of this study lies in that it expands the idea of the Ya-Aeng from the events inside Changgyeongwon into the urban culture, which is a projection of modern urban society. In addition, where the Ya-Aeng in the past had been regarded as a decadent and poor-quality spring celebration in comparison to the traditional spring celebration, this study proposes a new point of view for the Ya-Aeng in an urban social context.

Study on Radioactive Material Management Plan and Environmental Analysis of Water (II) Study of Management System in Water Environment of Japan (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (II) 일본의 물 환경 방사성물질 관리 체계에 대한 고찰)

  • Han, Seong-Gyu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.305-313
    • /
    • 2015
  • After Fukushima Daiichi nuclear disaster in 2011, study and maintenance of monitoring systems have been made at home and abroad. As concerns about radioactive contamination of water have increased in Korea, update of maintenance of managing radioactive materials in water is being made mainly by Ministry of Environment. In this study, we analysed current state of monitoring system modification in Japan, the country directly involved and neighboring country. According to the result, Japan modified the legislations first. Then Ministry of Education, Culture, Sports, Science and Technology (MEXT) provides theoretical background of radiological monitoring. And Ministry of the Environment actually watches state of water pollution in public waters and underground water. Finally related agencies like local government are monitoring current state of radioactive contamination in water environment. By region, local monitoring stations share the investigation of the whole country. Also, additional monitoring is running around nuclear facilities. After Fukushima disaster, monitoring for area near Fukushima is added. Among the reference levels, management target value of drinking water and tap water is 10 Bq/kg, and those of public water and underground water are 1 Bq/L. Measuring intervals varied from every hour to once a year, regularly or irregularly depending on the investigation. The main measuring items are air dose rate, gross ${\alpha}$, gross ${\beta}$, ${\gamma}$ radionuclide, Cs-134, Cs-137, Sr-89, Sr-90, I-131, and so on. In comparison, regulations about general public water in Korea need to be modified, while those about area near nuclear facility and drinking water are organized well. In future, therefore, domestic system would be expected to be modified with making reference to the guidelines like WHO's one. As good case of applying international guideline to domestic environment, Japanese system could be a reference when general standard of radioactivity in public water is made in Korea.

Distribution of Pollutant Content within Surface Sediment and Evaluation of Its Removal Efficiency in the Sihwa Constructed Wetland (시화호 인공습지에서 표층퇴적토의 오염물질 함량 분포와 제거효율 평가)

  • Choi, Don-Hyeok;Choi, Kwang-Soon;Kim, Dong-Sup;Kim, Sea-Won;Hwang, In-Seo;Lee, Mi-Kyung;Kang, Ho;Kim, Eun-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.755-764
    • /
    • 2009
  • To estimate the pollutant removal efficiency by surface sediment, matter content within surface sediment and its release from the sediment were investigated at 12 sites in the Sihwa constructed wetland. The content of COD, TOC, IL, TN, and TP within sediment varied temporally and spacially, showing ranges of 4.1~7.7 mg/g, 0.29~2.81%, 1.88~8.15%, 0.03~0.35%, 362~1,150 ${\mu}g$/g, respectively. The contents of organic matter and TN were significantly highest in March and decreased towards fall (March${\geq}$May${\geq}$July${\geq}$September, p=0.003 for COD, p=0.001 for TOC, p=0.017 for IL, p=0.015 for TN), whereas TP content was not significant statistically in difference between sampling times. The contents of heavy metals also varied largely with sampling sites and times (As:3.5~3.9 ${\mu}g$/g, Cd:0.08~0.38 ${\mu}g$/g, Cr:51.8~107.0 ${\mu}g$/g, Cu:16.4~81.8 ${\mu}g$/g, Pb:26.~81.8 ${\mu}g$/g, Zn:85~559 ${\mu}g$/g). As compared with sediment quality guideline, the content of organic matter within surface sediment of the Sihwa constructed wetland was classified as unpolluted level. In contrast, the contents of TN, TP and heavy metals were classified as medium or severe pollution state, except some heavy metals (Cu and Pb). From the results of release experiment, TN, Pb, and Zn tend to be removed by surface sediment, but TP, Cd, and Cu have a tendency to released from sediment. Therefore, a relevant plan to improve the removal efficiency of pollutant (especially phosphorus) by surface sediment in the Sihwa constructed wetland is needed.

New Fast Block-Matching Motion Estimation using Temporal and Spatial Correlation of Motion Vectors (움직임 벡터의 시공간 상관성을 이용한 새로운 고속 블럭 정합 움직임 추정 방식)

  • 남재열;서재수;곽진석;이명호;송근원
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.247-259
    • /
    • 2000
  • This paper introduces a new technique that reduces the search times and Improves the accuracy of motion estimation using high temporal and spatial correlation of motion vector. Instead of using the fixed first search Point of previously proposed search algorithms, the proposed method finds more accurate first search point as to compensating searching area using high temporal and spatial correlation of motion vector. Therefore, the main idea of proposed method is to find first search point to improve the performance of motion estimation and reduce the search times. The proposed method utilizes the direction of the same coordinate block of the previous frame compared with a block of the current frame to use temporal correlation and the direction of the adjacent blocks of the current frame to use spatial correlation. Based on these directions, we compute the first search point. We search the motion vector in the middle of computed first search point with two fixed search patterns. Using that idea, an efficient adaptive predicted direction search algorithm (APDSA) for block matching motion estimation is proposed. In the experimental results show that the PSNR values are improved up to the 3.6dB as depend on the Image sequences and advanced about 1.7dB on an average. The results of the comparison show that the performance of the proposed APDSA algorithm is better than those of other fast search algorithms whether the image sequence contains fast or slow motion, and is similar to the performance of the FS (Full Search) algorithm. Simulation results also show that the performance of the APDSA scheme gives better subjective picture quality than the other fast search algorithms and is closer to that of the FS algorithm.

  • PDF

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Geographic Distribution of Periphyton Diatom Species: A Case Study of Achnanthes convergens in Nakdong River Basin (낙동강 수계 청수성 부착조류의 공간분포 특성에 관한 연구: Achnanthes convergens 를 사례로)

  • Jo, Myung-Hee;Byun, Myeung-Sub;Sim, Jun-Seok;Jang, Sung-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.175-194
    • /
    • 2014
  • This study attempts to identify the spatial distributions of Achnanthes convergens, and elucidate the environmental factors that affect the Periphyton diatom habitat. Data in 250 points of Nakdong river basin are collected between April(primary) and September(secondary) 2012, with the National Institute of Environmental Research's support. We define "clean area" over 10% of Achnanthes convergens appearance, and the others as "non-clean areas". Spatial statistics of Kriging, Hotspot, LISA are used in this study. Results show that 1) 56 points are identified as clean areas in the primary survey, while 41 points are discovered in the following survey; 2) using water quality variables, density of turbidity(clean $101.83{\mu}s/cm$; non-clean $598.48{\mu}s/cm$) and conductivity(clean 1.95 NTU; nonclear 5.58 NTU) are five-fold lower in clean-areas; 3) Habitat and Riparian Factors in Nakdong basin illustrate that natural sand bar, diversity of velocity, sediment condition, levee material, riverside land affect Achnanthes convergens; 4) Hotspots of Achnanthes convergens are located in watersheds, including upper Andong Dam, upper Imha dam, Wi-cheon, Miryang river, Nam river and Hwang river whereas mainstream/downstream of Nakdong river and Keumho river watershed are shown as coldspots.

Determination of β-Carotene and Retinol in Korean Noodles and Bread Products (가공 및 외식식품 중 면류 및 제빵류의 레티놀 및 베타카로틴 함량 조사)

  • Shin, Jung-Ah;Chun, Ji Yeon;Lee, Junsoo;Shin, Ki Yong;Lee, Soon Kyu;Lee, Ki-Teak
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.12
    • /
    • pp.1949-1957
    • /
    • 2013
  • The contents of ${\beta}$-carotene and retinol in processed and restaurant foods, such as Korean noodles, mandus, rice cakes and bread products, were quantified by high-performance liquid chromatography (HPLC) with UV/visible and fluorescence detector, respectively. Samples were collected from different local areas (i.e. Gangwon-do, Gyeonggi-do, Gyeongsang-do, Seoul, Jeolla-do, and Chungcheong-do). After homogenization, samples were hydrolyzed by direct alkali saponification; thereafter, fat-soluble components were extracted by a mixture of n-hexane/ethylacetate (85:15, v/v), containing 0.01% butylated hydroxytoluene (BHT). ${\beta}$-carotene and retinol contents in infant formula used as an in-house material for the analytical quality control. Among 14 Korean noodles, high contents of ${\beta}$-carotene were found in Bibim-Guksu (average 442.43 ${\mu}g/100g$) and Jjolmyeon (average 301.39 ${\mu}g/100g$). In 4 Korean mandus, the highest contents of ${\beta}$-carotene was determined in Kimchi-mandu (average 197.64 ${\mu}g/100g$), resulting in 33.3 RE of the converted vitamin A. Among 12 Korean rice cakes, Maeun-Tteokbokki and Modm-Chaltteok contained relatively high content of ${\beta}$-carotene with 205.11 and 41.33 ${\mu}g/100g$, respectively, while retinol was detected only in Maeun- Tteokbokki (1.65~10.45 ${\mu}g/100g$). In addition, among 8 bread products, 77.3 RE of pastry, 51.2 RE of buttercream- bread, and 41.4 RE of morning roll were found as the contents of the converted vitamin A.

Determination of Types and Element on Parking Ramp (주차장 램프 형식 결정 및 제원 산정에 관한 연구)

  • Kwon, Sung-Dae;Kim, Yoon-Mi;Nam, Chang-Kyu;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.2021-2031
    • /
    • 2013
  • Due to the rapid economic growth within the nation, the quality of life of individuals have improved dramatically. The scope of living activities of individuals have also extended, resulting in a rapidly increasing demand for automobiles. The number of vehicles registered in Korea is rapidly increasing and will reach 188.71 million as of December 2012. Compared to the registered residents of 50.94 million provided by the Ministry of Public Administration and Security, the registered population reflects about 4 people per every automobile. Due to the high demands for vehicles, the demands for parking lots in collective housing and businesses are also increasing. In reality, the current state of expansion of parking lots are underground, due to the limited available space on ground level. Specifically, the slope of a parking lot cannot exceed 17% linear slope and 14% curved slope according to the 'parking lot laws', however studies show that the driver feels at risk for safety when stopped on the parking ramp while driving in the parking lot. This study seeks to examine the suitability of parking lot ramps, concerning the safety aspects of the driver. First, the ramp type was categorized as linear or curved, then test drives were performed based on variations of slopes, slant distances, directions and points. A survey was administered to the driver after the completion of the test drive, in order to element design for an ideal ramp. In the case of curved ramp, the results of the estimate suggests a counterclockwise, slope at a maximum of 12% incline. The maximum slope for a linear ramp was analyzed to be between 13~14%, suggesting that slope greater than 15% need to be eliminated. In conclusion, it is anticipated that the element design parking ramp reported in this study will help to serve as a reference for future parking lot related guidelines, and provide cost effective traffic safety mechanisms in future parking lot businesses to follow.

Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System (피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가)

  • Hwang, Tae-Jin;Kang, Sei-Kwon;Cheong, Kwang-Ho;Park, So-Ah;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2009
  • Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.

  • PDF