• Title/Summary/Keyword: Quality control device

Search Result 434, Processing Time 0.025 seconds

Design of Amplify-and-Forward Helper Stations for Cellular Networks with Device-to-Device Links (단말 간 직접 통신을 포함하는 셀룰러 망을 위한 증폭 후 전달 방식 조력국의 설계 방법)

  • Chung, Jihoon;Kim, Donggun;Sung, Youngchul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.5
    • /
    • pp.539-545
    • /
    • 2016
  • In this paper, the use of an amplify-and-forward (AF) helper station in a cellular network with device-to-device (D2D) communication links is considered to enhance D2D rates and control the interference caused by D2D users to the cellular network. Two design criteria for the AF helper station are considered to improve the overall system quality-of-service (QoS). One is maximization of the worst D2D user rate under a constraint on interference caused by D2D users to the cellular network and the other is its dual, i.e., minimization of interference caused by D2D users to the cellular network with minimum rate guarantee for each D2D user. It is shown that the considered problems reduce to semi-definite programming (SDP) problems. Numerical results show that the proposed AF helper station significantly improves the system performance.

Identification of operating parameters in auto-discharging filter system for treatment of urban storm water (자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출)

  • Kim, Sun-Hee;Gwon, Eun-Mi;Pak, Sung-Soon;Joh, Seong-Ju;Lim, Chea-Hoan;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.

A Status Report on Dual Energy X-ray Absorptiometry Quality Control in Korea (이중에너지 방사선흡수 골밀도 장치의 품질관리 현황)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Sung-Su;Kim, Kyoung-Ah;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.527-534
    • /
    • 2016
  • Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

Development of the Spent Fuel Rod Cutting Device by Cutter Blade Method (Cutter blade 방식에 의한 사용후핵연료봉 절단 장치 개발)

  • 정재후;윤지섭;홍동회;김영환;김도우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.393-396
    • /
    • 2000
  • Spent fuel rod cutting device should cut a spent fuel rod to an optimal size in order to fast decladding operation. In this paper, for developing spent fuel rod cutting device with cutter blade, rod properties such as dimension and material of zircaloy tube and fuel pellet are investigated at first and then, various methods of existing cutting devices used commercially are investigated and their performance are analyzed and compared. This device is designed to be operated automatically via remote control system considering later use in Hot-Cell (radioactive area) and the mdularization in the structure of this device makes maintenance easy. SUS and Zircaloy-4 are selected as cut material used in the test of spent fuel rod cutting device by cutter blade. In order for constructing the high durable cutter blade, various materials are analyzed in terms of quality, shape, characteristic, and heat treatment, etc. and from these results, spent fuel rod cutting device is designed and manufactured based on the considerations of durability, round shape sustainability of rod cross-section, debris generation, and fire risk, etc.

  • PDF

Realization of Virtual Device Network(VDN) for Predictive Maintenance

  • Choi, Gi-Heung;Song, Ki-Won
    • Bulletin of the Korean Institute for Industrial Safety
    • /
    • v.2 no.1
    • /
    • pp.6-10
    • /
    • 2002
  • Requirements for Distributed Monitoring and Control Networks(DMCN) differ greatly from those of typical data networks. Specifically, my DMCN technology which employs a filedbus protocol is different from IP network protocol TCP/IP. In general, one needs to integrate fieldbus protocol and TCP/IP to realize DMCN over IP network or internet, which can be viewed as Virtual Device Network(VDN). Interoperability between devices and equipments is essential to enhance the quality and the performance of predictive maintenance(PM). This paper suggests a basic framework for VDN using DMCN over IP network and a method to guarantee interoperability between devices and equipments.

  • PDF

Development of Simple Evaluation Method for Determining the Priority of Medical Device Replacement in Hospitals (병원내 의료기기 교체의 우선순위 결정을 위한 단순평가법 개발)

  • Seo, Gihong;Park, Eunkyoung;Choi, Dongil
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.256-263
    • /
    • 2020
  • The importance of quality control has been emphasized to maintain safety of patients and satisfaction of medical service with medical devices used in clinic. Accordingly, objective evaluation method and standards consistently has been brought up for demand to replace outdated medical devices in appropriate time and to maintain the quality of medical service. Though many studies made suggestions methods to determine what medical devices to be replaced first, these methods were difficult in practice for its complex evaluation criteria and long time to evaluate. Therefore, in this study, a simple evaluation method is developed to identify and prioritize medical devices that are ought to be replaced. For the development of this simple evaluation method, four major characteristics of technology, safety, finance, and user satisfaction, which are considered in clinics to evaluate medical device replacement, and 14 minor attributes are distinctively selected. Each characteristic is assessed in binary form of "YES" or "NO" to minimize its subjective nature. Using this method to evaluate sampled medical devices belonging to four different characteristics, devices are suggested to be replaced in the current financial year or in the following financial year, or re-evaluated by the end of this financial year. Such results of evaluation can amend the subjective nature of existing evaluation method and give objective standards more promptly.

Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System (인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

An Efficient Game Theory-Based Power Control Algorithm for D2D Communication in 5G Networks

  • Saif, Abdu;Noordin, Kamarul Ariffin bin;Dimyati, Kaharudin;Shah, Nor Shahida Mohd;Al-Gumaei, Yousef Ali;Abdullah, Qazwan;Alezabi, Kamal Ali
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.7
    • /
    • pp.2631-2649
    • /
    • 2021
  • Device-to-Device (D2D) communication is one of the enabling technologies for 5G networks that support proximity-based service (ProSe) for wireless network communications. This paper proposes a power control algorithm based on the Nash equilibrium and game theory to eliminate the interference between the cellular user device and D2D links. This leadsto reliable connectivity with minimal power consumption in wireless communication. The power control in D2D is modeled as a non-cooperative game. Each device is allowed to independently select and transmit its power to maximize (or minimize) user utility. The aim is to guide user devices to converge with the Nash equilibrium by establishing connectivity with network resources. The proposed algorithm with pricing factors is used for power consumption and reduces overall interference of D2Ds communication. The proposed algorithm is evaluated in terms of the energy efficiency of the average power consumption, the number of D2D communication, and the number of iterations. Besides, the algorithm has a relatively fast convergence with the Nash Equilibrium rate. It guarantees that the user devices can achieve their required Quality of Service (QoS) by adjusting the residual cost coefficient and residual energy factor. Simulation results show that the power control shows a significant reduction in power consumption that has been achieved by approximately 20% compared with algorithms in [11].

IEC61850 Process Bus Based Distributed Power Quality Monitoring (IEC61850 프로세서 버스 기반 분산형 전력품질감시)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.13-18
    • /
    • 2007
  • In this paper, authors deal with an application of power quality monitoring using the Sampled Value which is described in the IEC61850 International Standard for substation communication. Firstly, while Merging Unit is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are issued. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests non time critical service comparing to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. At last, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit. With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

High Quality Vertical Silicon Channel by Laser-Induced Epitaxial Growth for Nanoscale Memory Integration

  • Son, Yong-Hoon;Baik, Seung Jae;Kang, Myounggon;Hwang, Kihyun;Yoon, Euijoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.169-174
    • /
    • 2014
  • As a versatile processing method for nanoscale memory integration, laser-induced epitaxial growth is proposed for the fabrication of vertical Si channel (VSC) transistor. The fabricated VSC transistor with 80 nm gate length and 130 nm pillar diameter exhibited field effect mobility of $300cm^2/Vs$, which guarantees "device quality". In addition, we have shown that this VSC transistor provides memory operations with a memory window of 700 mV, and moreover, the memory window further increases by employing charge trap dielectrics in our VSC transistor. Our proposed processing method and device structure would provide a promising route for the further scaling of state-of-the-art memory technology.