• Title/Summary/Keyword: Quality Study

Search Result 53,936, Processing Time 0.077 seconds

Gene Expression Profiling by RNA Sequencing in Mature/Immature Oocytes of Chicken (닭의 성숙/미성숙란에서 RNA Sequencing을 이용한 유전자 발현 양상 고찰)

  • Kang, Kyung-Soo;Jang, Hyun-Jun;Park, Mi Na;Choi, Jung-Woo;Chung, Won-Hyong;Heo, Kang-Nyeong;Choe, Chang-Yong;Kim, Young-Joo;Lee, Si-Woo;Cho, Eun-Seok;Kim, Namshin;Kim, Tae-Hun;Han, Jae-Yong;Lee, Kyung-Tai
    • Korean Journal of Poultry Science
    • /
    • v.41 no.4
    • /
    • pp.287-296
    • /
    • 2014
  • Chicken eggs undergo various physiological changes during egg maturation. To study genes associated with the egg maturation in pre-ovulation (immature) and post-ovulation (mature), we compared gene expression patterns between in the immature egg and mature egg using RNA sequencing data. Mature and immature eggs were obtained from a Heuksaek Jaerae-jong of Korean native chicken. Total RNAs obtained from the eggs were sequenced by Illumina HiSeq 2000 platform, and the generated sequence reads were mapped to Galgal4 reference sequence assembly using Tuxedo Protocol. From the comparison of the RNA sequencing data, 315 genes were differentially expressed between mature and immature eggs, and 46 genes were only detected in immature egg. Further gene ontology (GO) analysis was performed for the differentially expressed genes using DAVID, showing that 29 and 28 GO terms were independently clustered from mature and immature, respectively. From those clustered GO terms, genes related to germ cell development, sex differentiation and defense response to bacterium were mainly expressed in the immature egg, while genes related to regulation of apoptosis, steroid metabolic process and lipid homeostasis were mainly detected in the mature egg. Our results could contribute to understand egg maturation before and after ovulation, and develop genetic markers for improving egg quality and productivity.

Comparison of Production Performances between Early- and Late-feathering Chickens in Parent Stocks of Korean Native Chicken (토종종계에 있어 조우성 개체와 만우성 개체간 생산능력 비교 고찰)

  • Kim, Ki Gon;Cho, Eun Jung;Choi, Eun Sik;Kwon, Jae Hyun;Jung, Hyun Chul;Sohn, Sea Hwan
    • Korean Journal of Poultry Science
    • /
    • v.46 no.4
    • /
    • pp.279-286
    • /
    • 2019
  • Currently, feather-sexing, which is based on differences in feather development at hatching, is a widely used chick sexing method in the poultry industry. For effective chicken feather-sexing, paternal early-feathering (EF) chickens and maternal late-feathering (LF) chickens must be bred. Therefore, it is critical to identify the effect of EF and LF patterns on production traits in chickens. Thus, the purpose of this study is to analyze and compare the production performances between 522 EF and 232 LF chickens in order to establish the Korean native chicken feather-sexing lines. The results showed that the survival rate of the LF group was significantly higher than that of the EF group from hatching to 52 weeks of age (P<0.05). Body weight, however, was not significantly different between the two groups at all ages. LF and EF groups did not significantly differ in age at first egg laying. However, the hen-day and hen-housed egg production of the LF group were significantly higher than those of EF group (P<0.01). No significant differences were found between the EF and LF groups in all egg quality indicators such as egg weight, eggshell color, albumin height and Haugh unit. Because the breeding target of Korean native commercial chicken is meat-type chicken, feather-sexing strains of Korean native chicken should be established using weighing-based paternal EF lines and laying-based maternal LF lines. Therefore, these results are critical for establishing desirable and effective feather-sexing strains.

Development of Smart Packaging for Cream Type Cosmetic (크림 제형 화장품용 스마트 패키징 기술 개발)

  • Jeon, Sooyeon;Moon, Byounggeoun;Oh, Jaeyoung;Kang, Hosang;Jang, Geun;Lee, Kisung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.79-87
    • /
    • 2019
  • The degree of cosmetic's oxidation depends on the storage conditions and external conditions when using the product. The microbial contamination and oxygen exposure often results in the quality deterioration of cosmetics. In addition, the problem is that consumers often use cream-type cosmetics, which have short expiration period (6-12 months), even after the product is expired. When using the deteriorated cosmetics, it can be fatal to consumers' safety including some symptoms such as folliculitis, rashes, edema, and dermatitis. Therefore, it is necessary to develop sealed smart packaging for cosmetics to prevent the deterioration of cosmetics and improve consumer safety. In this study, we have developed smart packaging design for cosmetics that can measure the surrounding environment and expiration date for the cosmetics in the real time. In addition, the smart packaging includes sensor, which are linked to the mobile application. Users can find out the measurement results through the application. Also, the packaging design and functions were set up based on the survey results by the user and feasible model can be produced based on user choice. The measurement in the three environment has been done after manufactured the sensor, PCB, and mobile application. As a result, it works normally within a certain range under all three environmental conditions. It is believed that the information on expiration dates and storage environment can be efficiently delivered to the consumers through developed cosmetics smart packaging and applications. The development of UI/UX design for consumer is further studied. The UX/UI design of the application plays an essential role in achieving this goal through the commercialization the cosmetic products in the wide range.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Usefulness of applying Macro for Brain SPECT Processing (Brain SPECT Processing에 있어서 Macro Program 사용의 유용성)

  • Kim, Gye-Hwan;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyeon-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Diagnostic and functional imaging softwares in Nuclear Medicine have been developed significantly. But, there are some limitations which like take a lot of time. In this article, we introduced that the basic concept of macro to help understanding macro and its application to Brain SPECT processing. We adopted macro software to SPM processing and PACS verify processing of Brain SPECT processing. Materials and Methods: In Brain SPECT, we choose SPM processing and two PACS works which have large portion of a work. SPM is the software package to analyze neuroimaging data. And purpose of SPM is quantitative analysis between groups. Results are made by complicated process such as realignment, normalization, smoothing and mapping. We made this process to be more simple by using macro program. After sending image to PACS, we directly input coordinates of mouse using simple macro program for processes of color mapping, adjustment of gray scale, copy, cut and match. So we compared time for making result by hand with making result by macro program. Finally, we got results by applying times to number of studies in 2007. Results: In 2007, the number of SPM studies were 115 and the number of PACS studies were 834 according to Diamox study. It was taken 10 to 15 minutes for SPM work by hand according to expertness and 5 minutes and a half was uniformly needed using Macro. After applying needed time to the number of studies, we calculated an average time per a year. When using SPM work by hand according to expertness, 1150 to 1725 minutes (19 to 29 hours) were needed and 632 seconds (11 hours) were needed for using Macro. When using PACS work by hand, 2 to 3 minutes were needed and for using Macro, 45 seconds were needed. After applying theses time to the number of studies, when working by hand, 1668 to 2502 minutes (28 to 42 hours) were needed and for using Macro, 625 minutes (10 hours) were needed. Following by these results, it was shown that 1043 to 1877 (17 to 31 hours were saved. Therefore, we could save 45 to 63% for SPM, 62 to 75% for PACS work and 55 to 70% for total brain SPECT processing in 2007. Conclusions: On the basis of the number of studies, there was significant time saved when we applied Macro to brain SPECT processing and also it was shown that even though work is taken a little time, there is a possibility to save lots of time according to the number of studies. It gives time on technologist's side which makes radiological technologist more concentrate for patients and reduce probability of mistake. Appling Macro to brain SPECT processing helps for both of radiological technologists and patients and contribute to improve quality of hospital service.

  • PDF

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination (CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상)

  • Beom, Hyinam;Han, Jaebok;Song, Jongnam;Kim, Wook;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • This study aims to improve the satisfaction level of the patient who undergoes CT contrast examination by developing and applying pretreatment process system, which not only can reduce the side effects caused by the test but also can help carry out the test smoothly. The subjects were 214 patients who booked CT contrast examination from January 2014 to February 2014 but could not carry out their test on schedule. We analyzed the reasons for the delay and conducted follow-up survey on them. We analyzed the usefulness of pretreatment process system by contemplating and developing pretreatment process system and applying it to the patients for whom follow-up survey was conducted from January 2015 to February 2015. The number of outpatients who came to the hospital form January to February 2014 was 2,846 and the number of patients who could not undergo the test was 214, accounting for 7.52% of the total. The specific reason for the delay includes 214 cases of unknown creatinine 98 with 120 minutes of average delay time, 40 cases of creatinine over 1.3(19%) with 30minutes of average delay time, 34 cases of past contrast media side effect 6% with 40 minutes of average delay time and 25 cases of lack of pretreatment such as fasting, etc. 11% with 120minutes of average delay time. The number of CT scan has been increasing ever since the development of CT and the frequency of using the contrast media is expected to increase. If we can employ pretreatment process system in order to effectively control the side effect of contrast media and help the CT contrast examination to be smoothly conducted on schedule, I'm sure we could improve the quality of our medical service and increase our patients' satisfaction who come to our CT scan room.

A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning (경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구)

  • Kim, Hyeon-Ju;Chung, Woo-Jun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • There is a difficulty because of classifying the anatomical structure in the neck CT scan by the beam hardening artifact no more than disease and it including the 6, 7 number cervical spine and intervertebral disk. In case of enforcing the neck CT scan cause of the inner diameter of beam artifact tried to be inquired by the image evaluation according to the change of the image evaluation according to the direction of the shoulder joint applying the variation method of a posture and location and Kernel value and it was most appropriate, the lion tax and Kernel value try to be searched for through an experiment. Somatom Sensation 16 (Siemens, Enlarge, Germany) equipment was used in a patient 30 people coming to the hospital for the neck CT scan. A workstation used the AW 4.4 version (GE, USA). According to a direction and location of the shoulder joint, the patient posture gave a change to the direction of the shoulder joint as the group S it gave a change as three postures and placed the both arms comfortably and helps a group N and augmented unipolar left in the wealthy merchant and group P it memorized the both hands and ordered the eversion and drops below to the utmost and enforced a scan. By using a reconstructing method as the second opinion, it gave and reconstructed the Kernel value a change based on scan data with B 10 (very smooth), B 20 (smooth), B 30 (medium smooth), B 40 (medium), B 50 (medium sharp), B 60 (sharp), and B 70 (very sharp). By using image data which gave the change of the examination posture and change of the Kernel value and are obtained, we analyzed through the noise value measurement and image evaluation of. The outside wire eversion orders the both hands and the examination posture is cost in the neck CT scan with the group P it drops below to the utmost. And in case of when reconstructing with B 40 (medium) or B 50 (medium sharp) being most analyzed into the inappropriate posture and Kernel value and applying the Kernel value to a clinical, it is considered to be very useful.