• Title/Summary/Keyword: Quality Output

Search Result 1,503, Processing Time 0.031 seconds

System of stable action waveform by pulse special quality of obstetrics and gynecology pulse style $CO_2$ laser (산부인과 펄스형 $CO_2$ 레이저의 펄스 특성에 의한 안정된 동작파형의 시스템)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.55-57
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular, tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

The Impact of Input and Output Tariffs on Domestic Employment across Industries: Evidence from Korea

  • Jang, Yong Joon
    • Journal of Korea Trade
    • /
    • v.24 no.8
    • /
    • pp.1-18
    • /
    • 2020
  • Purpose - This paper examines how differently output and input tariffs affect domestic employment across industrial characteristics of comparative advantage such as labor quality and capital intensity. Design/methodology - The paper focuses on 453 Korean industries from 2007 to 2014 because Korea is a typical example of a natural resource-scarce open economy and experienced the transition of the export pattern from labor intensity to technology intensity during this period. Findings - The results show that input tariff reduction stimulated total employment, focusing on the early 2010s, while the effects of output tariff reduction were statistically insignificant in general. However, the stimulation effects of output tariff reduction on employment were found in comparative advantage industries with greater labor quality and capital intensity. As for input tariff reduction, its stimulation effects on employment were more prominent in comparative disadvantage industries with lower labor quality and capital intensity. Originality/value - These results provide significant implications for natural resource-scarce open economies which are experiencing the transition of the export pattern from labor intensity to technology intensity and the unequal distribution of income after trade liberalization: imported intermediate inputs has become increasing important, leading to trade effects on employment and alleviation of income inequality.

Research on Improving Output Quality through Design and Manufacturing of Food 3D Printer Parts (식품 3D 프린터 부품 설계 및 제조를 통한 출력 품질 향상 연구)

  • Jung-Sub Kim;Tae-Sung Kim;Gyu-Seok Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.133-140
    • /
    • 2024
  • In this paper, we aim to improve the output quality of a food 3D printer through optimized component design and implementation. Existing 3D printers produce customized outputs according to consumer needs, but have problems with output speed and poor quality. In this paper, we aim to solve this problem through optimized design of unit parts such as the extruder, nozzle, guide, and external case. Fusion 360 was used for element design, and in the performance evaluation of the implemented system, the average precision was 0.06mm, which is higher than the non-repeatable precision of ±0.1mm of other products, and the feed speed of the existing system was evaluated to be more than twice as fast, from 70mm/s to 140mm/s. In the future, we plan to continuously research output elements that can produce texture and color and device control methods for convenience.

Understanding Service Quality in Health/Fitness Clubs from A Systems Perspective

  • Kyungro Chang
    • Asia Marketing Journal
    • /
    • v.1 no.3
    • /
    • pp.53-78
    • /
    • 1999
  • Despite of the vibrant nature of the fitness industry, there has not been a sustained effort to understand the dynamics of the industry, particularly with reference to the quality of services offered in that industry. The purpose of this paper is to present a system based process model of quality in health/fitness services. The characteristics of the organization, the service employees and the client are the inputs into the service encounter where the service is produced (i.e., the throughput). The output is the quality of the service. The extent of quality perceived by both the service provider and the client is said to influence the satisfaction of the respective parties, and subsequent motivation to participate in the production of quality in the service. The model also suggests that physical environment as well as other customers and their behaviors influence customer perception of service quality. The quality of service is enhanced through the quality assurance practices of the organization and the feedback from client. Further, the input, throughput, and output in our model reflect (a) quality of the design of the service delivery system, (b) objective quality of the product, and (c) quality as perceived by client. The specific attributes of the design element (i.e., organization, service employee, and the client) are elaborated upon. It is suggested that the organization can assure quality by seeking feedback from clients and service employees, monitoring the service production phases, and managing inter-customer interactions.

  • PDF

Evaluation of Clinical Application Model of Optimized Parameter through Analysis of Stability of Radiation Output and Image Quality when Exposure Time Change of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 조사시간 변화 시 방사선 출력과 영상 화질의 안정성 분석을 통한 최적화된 파라미터의 임상 적용 모델 평가)

  • Hwang, Jun-Ho;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.139-148
    • /
    • 2020
  • The purpose of this study is to propose a method to optimize the performance of Digital Radiography (DR) by analyzing the effect of exposure time change on the stability of radiation output and image quality. The experimental method was used to change the exposure time to 50 msec, 100 msec, 200 msec, and 400 msec so that the Percentage Average Error (PAE), Time-to-Radiation Dose Curve, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and theses analysis were performed to evaluate the normal operation of parameters, radiation output and image quality. As a result, all the parameters used in the experiment showed the Percentage Average Error in the normal range, and the shorter the exposure time, the stability of radiation output and image quality decrease. In conclusion, it was found that the performance of Digital Radiography can be optimized when stable radiation output and image quality are applied by applying 100 msec ~ 200 msec exposure time.

Investigation About Quality Control of General X-ray System

  • Kang, Byung-Sam;Son, Jin-Hyun;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.157-164
    • /
    • 2011
  • This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

  • PDF

Study on Productivity Enhancement and the Present Status of Korean Manufacturing Industrial Productivity & Qualify (우리 제조공업의 생산성 및 품질수준 현황과 그 향상책)

  • 신용백
    • Journal of the Korean Professional Engineers Association
    • /
    • v.27 no.6
    • /
    • pp.85-93
    • /
    • 1994
  • For the continuous development of the manufacturing company, selp-helpㆍdiligence of the individual members of the organization and cooperation system of the sub-department process of the manufacture must operate under rationality. Moreover, perpetual and reasonable improvement on productivity should be focused on. Improvement on productivity implies raising $\ulcorner$output / input$\lrcorner$ ratio, and this does not only implies simple increase of the level of output. Therefore under the theoretical principle, Which is designed to increase the ratio of $\ulcorner$output / input$\lrcorner$ -economically select the relevant $\ulcorner$methodology$\lrcorner$. When rational improvement on productivity $\ulcorner$techniques$\lrcorner$ are properly applied with this methodology, calculated result will come out. The ultimate aim of improving quality does not mean simply reducing the percentage of the defects, but means improving the quality of products, for customer satisfaction. Thus recognize this, we have to contribute to the national economy growth through the enhancement of added value of individual company by $\ulcorner$improvement on quality and productivity, and reduction of the cost$\lrcorner$, $\ulcorner$improvement program on quality and productivity$\lrcorner$ shouldn't be just the parading formality. We can expect the economy result, these are applied to the learning essence and the principle of the improvement.

  • PDF

A study on the accuracy of multi-task learning structure artificial neural network applicable to multi-quality prediction in injection molding process (사출성형공정에서 다수 품질 예측에 적용가능한 다중 작업 학습 구조 인공신경망의 정확성에 대한 연구)

  • Lee, Jun-Han;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.16 no.3
    • /
    • pp.1-8
    • /
    • 2022
  • In this study, an artificial neural network(ANN) was constructed to establish the relationship between process condition prameters and the qualities of the injection-molded product in the injection molding process. Six process parmeters were set as input parameter for ANN: melt temperature, mold temperature, injection speed, packing pressure, packing time, and cooling time. As output parameters, the mass, nominal diameter, and height of the injection-molded product were set. Two learning structures were applied to the ANN. The single-task learning, in which all output parameters are learned in correlation with each other, and the multi-task learning structure in which each output parameters is individually learned according to the characteristics, were constructed. As a result of constructing an artificial neural network with two learning structures and evaluating the prediction performance, it was confirmed that the predicted value of the ANN to which the multi-task learning structure was applied had a low RMSE compared with the single-task learning structure. In addition, when comparing the quality specifications of injection molded products with the prediction values of the ANN, it was confirmed that the ANN of the multi-task learning structure satisfies the quality specifications for all of the mass, diameter, and height.

A Novel Harmonic Compensation Method for the Single Phase Grid Connected Inverters (단상 계통연계 인버터를 위한 새로운 고조파 보상법)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.144-146
    • /
    • 2018
  • In order to meet the harmonics standards such as IEEE 519 and P1547 the output quality of a grid connected inverter should satisfy a certain level of Total Harmonic Distortion (THD) value. However, the output quality of an inverter gets degraded due to the grid voltage harmonics, the dead time effects and the nonlinearity of the switches, which all contributes to a higher THD value of the output. In order to meet the required THD value for the inverter output under the distorted grid condition the use of harmonic controller is essential. In this paper a novel feedforward harmonic compensation method is proposed in order to effectively eliminate the low order harmonics in the inverter current to the grid. In the proposed method, unlike the conventional harmonic control methods, the hamonic components are directly compensated by the feedforward terms generated by the PR controller with the grid current in the stationary frame. The proposed method is simple in implementation but powerful in eliminating the harmonics from the output. The effectiveness of proposed method is verified through the PSIM simulation and the experiments with a 5kW single phase grid connected inverter.

  • PDF

A Comparative Study on Output of Four Type Diagnostic X-ray Equipments (정류방식에 따른 진단용 X-선 장치의 출력비교)

  • Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF