• Title/Summary/Keyword: Quality Output

Search Result 1,503, Processing Time 0.033 seconds

Power Balancing Control Method of A Residential Distributed Generation System using Photovoltaic Power Generation and Polymer Electrolyte Fuel Cells (PV와 PEFC를 병용한 가정용 분산 전원 시스템의 전력평준화 제어법)

  • Yoon, Young-Byun;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.335-339
    • /
    • 2016
  • Output power in photovoltaic systems changes steeply with the change of the sun intensity. The change of output power has influence on the electric power quality of the system. This paper proposes a residential distributed generation system using photovoltaic power generation and polymer electrolyte fuel cells(hybrid systems). In order to level the output power which changes steeply the polymer electrolyte fuel cells are connected to the photovoltaic power generation system in parallel. Thus the generated power of all the system can be leveled. However, the steep generated power in the photovoltaic power generation system can not be leveled. Therefore, the electric double layer capacitor(EDLC) is connected in parallel with the hybrid systems. It is confirmed by the simulation that the proposed distributed generation system is available for a residential supply.

The Performance Evaluation of Universities using DEA and AHP Model (DEA와 AHP를 이용한 대학의 성과 평가)

  • Han, Yu-Jung;Han, Chang-Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.3
    • /
    • pp.51-63
    • /
    • 2014
  • Because of the changing educational environments, Korean universities have to stand up to the challenge of enhancing their performances in educational activities. Therefore, Korean universities should seek ways to improve its competitiveness. The evaluation of Korean universities has been conducted by the Government and other media agencies like JoongAng's Daily to promote the development of universities. The purpose of this study is to evaluate and compare the relative efficiency of Korean universities using DEA (Data Envelopment Analysis) and AHP (Analytic Hierarchy Process) models. To produce reasonable results, major input and output variables have been determined in a step using a Profiling method, Spearman correlation analysis and AHP model. Also, this study shows that the relative efficiency for Korean universities is obtained not only based on quantity of output, but also on the basis of the quality of the output. Drawing upon the results of the analysis, this study provides a comprehensive and practical method for evaluating the performance of universities in terms of efficiency.

Output characteristics of intracavity frequency doubling of laser-diode end-pumped Nd:S-VAP laser (반도체레이저 단면여기 Nd:S-VAP 레이저의 내부공진기 제2고조파 출력 특성)

  • 박준학
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.294-298
    • /
    • 2000
  • The output characteristics of intracavity frequency doubling of laser-diode end-pumped Nd:S-VAP laser were investigated. Nd:S-VAP is suitable for a microchip laser medium, which has a low threshold property because of a very high value of the stimulated emission cross-section and lifetime product. The threshold energy measured was 81 J.ll. The second harmonic output energy measured was $126\mu\textrm{J}$at a pump energy of $2\mu\textrm{J}$. We described for intracavity frequency doubling by using theoretical calculations. Q-switched second harmonic energy measured was $15\mu\textrm{J}$per pulse with a pulse-width of 26 ns. at a pump energy of 2 mJ and an $M^2$ of 1.47 represented a good beam quality. ality.

  • PDF

Power Smoothing of a Variable-Speed Wind Turbine Generator Based on the Rotor Speed-Dependent Gain (회전자 속도에 따라 변하는 게인에 기반한 가변속 풍력발전기 출력 평활화)

  • Kim, Yeonhee;Kang, Yong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.533-538
    • /
    • 2016
  • In a power grid that has a high penetration of wind power, the highly-fluctuating output power of wind turbine generators (WTGs) adversely impacts the power quality in terms of the system frequency. This paper proposes a power smoothing scheme of a variable-speed WTG that can smooth its fluctuating output power caused by varying wind speeds, thereby improving system frequency regulation. To achieve this, an additional loop relying on the frequency deviation that operates in association with the maximum power point tracking control loop, is proposed; its control gain is modified with the rotor speed. For a low rotor speed, to ensure the stable operation of a WTG, the gain is set to be proportional to the square of the rotor speed. For a high rotor speed, to improve the power smoothing capability, the control gain is set to be proportional to the cube of the rotor speed. The performance of the proposed scheme is investigated under varying wind speeds for the IEEE 14-bus system using an EMTP-RV simulator. The simulation results indicate that the proposed scheme can mitigate the output power fluctuation of WTGs caused by varying wind speeds by adjusting the control gain depending on the rotor speed, thereby supporting system frequency regulation.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Analysis for the Operating Characteristics when the Induction Motor is Used as a Generator (유도전동기를 발전기로 사용시 동작 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.2
    • /
    • pp.5-11
    • /
    • 2014
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. The structure and operating characteristics of induction generator is almost identical to induction motor, but the induction generator part is used restrictively from hydropower power and wind power development etc. Recently induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than synchronous speed of induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load such as increaser, total efficiency is decreased. Consequently the quality in compliance with an induction motor parameter applying like that in the generator is a possibility of having the error of some. In this paper, we analyzed that input, output, torque and efficiency of induction machine is different from each other above and below synchronous speed.

13.56 MHz High Efficiency Class E Power Amplifier with Low Drain Voltage (낮은 드레인 전압을 가지는 13.56 MHz 고효율 Class E 전력증폭기)

  • Yi, Yearin;Jeong, Jinho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.6
    • /
    • pp.593-596
    • /
    • 2015
  • In this paper, we design a high efficiency class E power amplifier operating at low drain bias voltage for wireless power transfers. A 13.56 MHz power amplifier is designed at drain bias voltage of 12.5 V using Si MOSFET with the breakdown voltage of 40 V. High quality-factor solenoidal inductor is designed and fabricated for use in output matching circuit to improve output power and efficiency. Input matching circuit simply consists of resistor and inductor to reduce the circuit area and improve the stability. The fabricated power amplifier shows the measured output power of 38.6 dBm with the gain of 16.6 dB and power added efficiency of 89.3 % at 13.56 MHz.

Improving the Output Current of Matrix Converter under Abnormal Input Voltage Conditions using a Neural Network Compensator (입력 전원 외란 상황에서의 신경회로망 기반 전류 보상기를 이용한 매트릭스 컨버터의 출력 전류 개선)

  • Lee, Eun-Sil;Park, Ki-Woo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.199-206
    • /
    • 2010
  • Matrix converter is an energy conversion device of controlled power semiconductor switches that directly connects the three-phase source to the three-phase load. With no dc-link components for energy storage in the matrix converter the input current depends directly upon the load currents and the switch state of the converter. Therefore the unbalanced and distorted input voltages can result in unwanted output harmonic currents. This paper presents a current compensator based on neural network to improving output current quality for matrix converter under abnormal input voltage conditions. The effectiveness and feasibility of the proposed technique has been proven through numerical simulations and experimental tests.

Improvement of Output Waveforms in UPS Using the Discrete Control Technique (이산제어기법을 이용한 UPS의 출력파형 개선)

  • 김대곤;박해암;오금곤;조금배;백형래;김영동
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.57-63
    • /
    • 1997
  • Uninterruptible power supply(UPS) system should provide a good quality and stable power supply no matter what the condition of the raw mains. And when the mains fails, it must provide uninterrupted power to the load for a specified time. In this paper. discrete control system is introduced to improve output waveforms of UPS. This technique can be obtained output voltage by discrete data of synchronous control and voltage control to various loac. And then, the compact and light UPS can be realized by remove of the analog circuit and simulation and ezperinentation were performed with this control algofihtm. The experiment result show the effectiveness of proposed UPS system uwing the discrete control techjique.

  • PDF

Transient State Improvement of Three-Phase ZSI with the Input Feedforward and Fuzzy PI Controller (입력 피드포워드와 퍼지 PI제어기를 갖는 3상 ZSI의 과도상태 개선)

  • WU, Yan-Jun;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.359-360
    • /
    • 2012
  • This paper proposes a scheme of auto-tuning fuzzy PI controller and input voltage feed forward to control the output voltage of a three-phase Z-source inverter (ZSI). The proposed scheme adjusts the ts (Kp and Ki) in real time in order to find the most suitable Kp and Ki for PI controller and to simplify the controller design. The proposed scheme is verified the validity by experiment and co-simulation in PSIM and MATLAB/SIMULINK both load step change and input DC voltage variation in Z-source inverter, and has compared with the conventional PID control scheme. The experiment results involve of three-phase output voltage, Z-network capacitor voltage and dc-link peak voltage value. By those analysis and comparison, the availability of the proposed method in output voltage transient response quality improving has been verified. Compared with conventional PID method, the proposed method showed a more effective and robust control performance for coping with the severe disturbance conditions.

  • PDF