• Title/Summary/Keyword: Quality Output

Search Result 1,503, Processing Time 0.029 seconds

Optimal Design of VCO Using Spiral Inductor (나선형 인덕터를 이용한 VCO 최적설계)

  • Kim, Yeong-Seok;Park, Jong-Uk;Kim, Chi-Won;Bae, Gi-Seong;Kim, Nam-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.8-15
    • /
    • 2002
  • We optimally designed the VCO(voltage-controlled oscillator) with spiral inductor using the MOSIS HP 0.5${\mu}{\textrm}{m}$ CMOS process. With the developed SPICE model of spiral inductor, the quality factor of spiral inductor was maximized at the operating frequency by varying the layout parameters, e.g., metal width, number of turns, radius, space of the metal lines. For the operation frequency of 2㎓, the inductance of about 3nH, and the MOSIS HP 0.5 CMOS process with the metal thickness of 0.8${\mu}{\textrm}{m}$, oxide thickness of 3${\mu}{\textrm}{m}$, the optimal width of metal lines is about 20${\mu}{\textrm}{m}$ for the maximum Quality factor. With the optimized spiral inductor, the VCO with LC tuning tank was designed, fabricated and measured. The measurements were peformed on-wafer using the HP8593E spectrum analyzer. The oscillation frequency was about 1.610Hz, the frequency variation of 250MHz(15%) with control voltage of 0V - 2V, and the phase noise of -108.4㏈c(@600KHz) from output spectrum.

Hydrogeochemical Environmental Research in Nitrate Contamination in Alluvial Fan Area Groundwater in Tsukui, Central Japan (일본 츠꾸이 선상지 지하수의 질산성 질소 오염에 대한 수문지구화학적 연구)

  • Okazaki, Masanori;Ham, Young-Sik
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.4 s.109
    • /
    • pp.431-435
    • /
    • 2004
  • A nitrate-contaminated groundwater was hydrogeochemically investigated to estimate the factors controlling groundwater quality in an alluvial fan area. Even though monthly groundwater levels increased with monthly rainfalls, the monthly $NO_3^--N$ concentrations in groundwater showed a small variation, mostly exceeding a maximum contaminant level of 10 mg $L^{-1}$ in environmental quality standards for groundwater during 2003. The 2003 annual groundwater recharge was 1,730 mm =20,056 mm-18,326 mm. Where 20,056 mm and 18,326 mm are annual sum of daily increase and decrease in ground water level. However, the annual sum of increase in ground water level (20,056 mm) was approximately 10 times higher than annual rainfall. Moreover, the annual sum of daily ground water level decrease (-18,326mm) showed that a large amount of groundwater was discharged with $NO_3^-$-contamination. Hydrogeochemically, a large amount of groundwater input and output through the alluvial fan area were observed after rainfall with a considerably high concentration of $NO_3^-$. Consequently, this alluvial fan area including forest area reflects on the evidence under the condition of 'nitrogen excess' or 'nitrogen saturation'. In addition, such a large amount of groundwater outflow can cause environmental damage in surface water, associated with $NO_3^-$- contamination. This study also expects that this hydrogeochemical data will be useful for water management.

Study for Multi Channel Radiation Detector Using of Microfilm and Carbon Electrode (탄소막 마이크로필름을 이용한 다채널 전리함 개발에 관한 연구)

  • Shin Kyo Chul;Yun Hyong Geun;Jeong Dong Hyeok;Oh Yong Kee;Kim Jhin Kee;Kim Ki Hwan;Kim Jeung Kee
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.111-115
    • /
    • 2005
  • We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5$\%$, linearity was less than 0.5$\%$, and dose rate effect was less than 0.7$\%$. In addition the effect of dose variation from other chambers was estimated to maximum 0.8$\%$ approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.

  • PDF

NOVEL CNC GRINDING PROCESS CONTROL FOR NANOMETRIC SURFACE ROUGHNESS FOR ASPHERIC SPACE OPTICAL SURFACES (우주망원경용 비구면 반사경 표면조도 향상을 위한 진화형 수치제어 연삭공정 모델)

  • 한정열;김석환;김건희;김대욱;김주환
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.141-152
    • /
    • 2004
  • Optics fabrication process for precision space optical parts includes bound abrasive grinding, loose abrasive lapping and polishing. The traditional bound abrasive grinding with bronze bond cupped diamond wheel leaves the machine marks of about $20{mu}m$ rms in height and the subsurface damage of about 1 ${mu}m$ rms in height to be removed by subsequent loose abrasive lapping. We explored an efficient quantitative control of precision CNC grinding. The machining parameters such as grain size, work-piece rotation speed and feed rate were altered while grinding the work-piece surfaces of 20-100 mm in diameter. The input grinding variables and the resulting surface quality data were used to build grinding prediction models using empirical and multi-variable regression analysis. The effectiveness of such grinding prediction models was then examined by running a series of precision CNC grinding operation with a set of controlled input variables and predicted output surface quality indicators. The experiment achieved the predictability down to ${pm}20$ nm in height and the surface roughness down to 36 nm in height. This study contributed to improvement of the process efficiency reaching directly the polishing and figuring process without the need for the loose abrasive lapping stage.

Analytical Study of Delay Model of Traffic Signal Progression Evaluation on Arterial (간선도로 신호연동화 효율의 평가를 위한 지체도 모형의 해석적 연구)

  • 김영찬;황연하
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.1
    • /
    • pp.131-139
    • /
    • 1999
  • The quality of progression at signalized intersection has the largest potential effect. TRANSYT-7F is widely used to estimate the signal progression delay, but the progress of collecting and executing the compute program appears to be rather cumbersome. The research is to develop the analytical and progressing platoon delay model that is as simple as the methodology of HCM and familiar with the output of simulation model. The general approach to this research was conducted to examine the Rouphail and NCHRP 339 methodology together with the existing progression delay model (TRANSYT-7F. HCM). The scope is contained to be applicable only to cycles with no overflow queue and to obtain a comprehensive evaluation of the effects of changes in the quality of traffic signal progression on stopped delay and to be analyzed a simple mathematical method. The principle assumption for this model is that secondary flows is dispersed and partly mixed with average flow of the primary progressed flow. A second assumption is that through flow is consisted with the part of saturation flow at the front of it and the part of average flow at the rear of it. The delay equations vary for two arrival. The conclusion of this study could be summarized as 1)The evaluation of this model was consistently similar to that of TRANSYT-7F, 2) Platoon pattern has the real traffic flow characteristics. 3) The computing process of progression delay is made to have simple logic and easy calculation by integration, 4) This model could be estimated to be applied in almost all case.

  • PDF

Nutrient Digestibility, Palatability and Stool Quality of Canine Food Including Brown Rice (현미 함유 반려견 사료의 영양소 소화율, 분 특성 및 기호성)

  • Kim, Kyoung-Hoon;Chang, Ju-Song;Oh, Young-Kyoon;Ji, Sang-Yun;Moon, Sang-Ho;Kim, Myeong-Hwa
    • Journal of Animal Science and Technology
    • /
    • v.53 no.5
    • /
    • pp.435-440
    • /
    • 2011
  • In this experiment, two inclusion levels (15 and 30% of diets, as-fed basis) of brown rice (BR) were tested against a control diet with 0% BR (51% wheat flour of diet). Six female Maltese (8~9 months age, initial mean body weight of $2.8{\pm}0.3$ kg) were assigned to treatments in replicated $3{\times}3$ Latin square design. Total tract digestibilities of DM, OM, acid hydrolyzed fat, CP and gross energy by dogs fed experimental diets responded quadratically (P<0.01 or <0.05) to BR inclusion levels. Similarly, quadratic responses (P<0.001, P=0.015) were observed for digestible energy and metabolizable energy values, respectively. Wet and dry fecal output also exhibited quadratic responses (P=0.006, P=0.014, respectively) but no differences were observed between control and BR 30% diets. Linear (P=0.008) effect was observed for fecal score in dogs fed BR, and fecal ammonia concentration increased linearly (P=0.001) in response to increasing BR inclusion levels. It seems that the increase in fecal ammonia concentration may be partially related to the decrease tendency (P=0.07) in short-chain fatty acid concentration. In this experiment, inclusion of BR in dog diet did not result in pronounced changes in the digestibility but in fecal score. Although inclusion of BR in diets showed profound positive effect on fecal score, it is confounded by the high inclusion level of poultry offal meal.

A Study on the Current Situation and Problems of Agricultural Products e-Commerce in Korea (B2B 농산물 전자상거래 활성화 방안과 과제에 관한 연구)

  • Kim, Kyu-Hyong;Lee, Moon-Seok
    • International Commerce and Information Review
    • /
    • v.13 no.1
    • /
    • pp.29-52
    • /
    • 2011
  • A predictable and manageable output is desirable for most businesses. However, it is very difficult to control the quality and quantity of products in the food and agriculture business. Predictable outputs help managers plan their marketing, sales, and inbound and outbound logistics, but these are not easy to achieve in the food and agriculture business. Various industries have adopted different levels of automation and utilization of information systems for quality/quantity control; however e-Commerce of the food and agriculture industry is far behind those of other industries. Today, the food and agriculture industry is supposed to be more integrated than ever in order to reduce risks and improve processing costs, from farm to table. Since its operations including production, processing, storage, distribution, and management are dispersed all over the world, the food and agricultural industries now depend more on IT than other industries. This study attempts to develop a framework to analyze the current situation of agricultural product e-Commerce in Korea, and finds out the actual situation of the farmers operating on-line shopping systems through the developed framework and suggests some improvements.

  • PDF

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

Improvement of Endoscopic Image using De-Interlacing Technique (De-Interlace 기법을 이용한 내시경 영상의 화질 개선)

  • 신동익;조민수;허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.469-476
    • /
    • 1998
  • In the case of acquisition and displaying medical Images such as ultrasonography and endoscopy on VGA monitor of PC system, image degradation of tear-drop appears through scan conversion. In this study, we compare several methods which can solve this degradation and implement the hardware system that resolves this problem in real-time with PC. It is possible to represent high quality image display and real-time processing and acquisition with specific de-interlacing device and PCI bridge on our hardware system. Image quality is improved remarkably on our hardware system. It is implemented as PC-based system, so acquiring, saving images and describing text comment on those images and PACS networking can be easily implemented.metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF

The Development and Application of Multi-metric Water Quality Assessment Model for Reservoir Managements in Korea. (우리나라 인공호 관리를 위한 다변수 수질평가 모델의 개발 및 적용)

  • Lee, Hyun-Joon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.242-252
    • /
    • 2009
  • The purpose of this study was to develop a Multi-metric Water Quality Assessment (MWQA) model and apply it to dataset sampled from Paldang and Daechung reservoir in 2008. The various water dataset used to this study included 5 year data sets (2003${\sim}$2007) in Korean reservoirs which were obtained from the Ministry of Environment, Korea. In this study, suggested MWQA model has 4 metrics that were composed of 4 parameters such as chemical, physical, biological, and hydrological variables. And, each of the variables attributed total phosphorus (TP) concentration in water, secchi depth (SD) measure in water, chlorophyll-${\alpha}$(Chl-${\alpha}$) concentration in water and the ratio of inflow of water into lakes and efflux of water from lakes, input/output (I/O). First, we established the criteria for trophic boundaries. The boundary between oligotrophic and mesotrophic categories was defined by the lower third of the cumulative distribution of the values. The mesotrophic-eutrophic boundary was defined by the upper third of the distribution. Second, each metric was given by a point-oligo=1, meso=3, eu=5. And then, obtained total score from each metric was divided 5 grade-Excellent, Good, Fair, Poor, and Very poor. As the results of applying the proposed MWQA model, the Paldang reservoir obtained "Fair" or "Poor" grade and Daechung reservoir obtained "Excellent" or "Good" grade. The suggested MWQA model through these procedures will enable to manage efficiently the reservoir. And, more studies such as metric numbers and attributes should be done for the accurate application of the new model.