• Title/Summary/Keyword: Quality Output

Search Result 1,503, Processing Time 0.028 seconds

Stationary Reference Frame Voltage Controller for Single Phase Grid Connected Inverter for Stand Alone Mode (계통 연계형 단상 인버터의 단독 운전 모드를 위한 정지좌표계 전압 제어기)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.517-525
    • /
    • 2015
  • A grid connected inverter must be operated as the main electricity source under an isolated condition caused by the grid problem. Conventionally, the dual loop controller is used for the grid inverter, and the controller is used for control under the stand-alone mode. Generally, the PI(Proportional - Integral) controller is highly efficient under a synchronous reference frame, and stable control can be available. However, in this synchronous frame-based control, high-quality DSP is required because many sinusoidal calculations are necessary. When the PI control is conducted under a stationary frame, the controller constructions are made simple so that they work even with a low-price micro controller. However, given the characteristics of the PI controller, it should be designed with the phase of reference voltage considered. Otherwise, the phase delay of the output voltage can occur. Although the current controller also has a higher bandwidth than the voltage controller, distortion of the voltage is difficult to avoid only by the rapid response of the PI controller, as a sudden load change can occur in the nonlinear load. In this study, a new control method that solves the voltage controller bandwidth problem and rapidly copes with it even in the nonlinear load situation is proposed. The validity of the proposed method is proved by simulation and experimental results.

Dead Time Compensation of Grid-connected Inverter Using Resonant Controller (공진 제어기를 이용한 계통 연계형 인버터의 데드타임 보상)

  • Han, Sang-Hyup;Park, Jong-Hyoung;Kim, Heung-Geun;Cha, Honn-Yong;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.569-576
    • /
    • 2011
  • This paper proposes a new dead time compensation method for a PWM inverter. Recently, PWM inverters are extensively used for industry applications, such as ac motor drives, distributed grid-connected systems and a static synchronous compensator (STATCOM). Nonlinear characteristics of the switch and the inverter dead time cause a current distortion and deterioration of power quality. The dominant harmonics in the output current are the $5^{th}$ and $7^{th}$ harmonics in the stationary frame, and the $6^{th}$ harmonics in the synchronous rotating frame. In this paper, a resonant controller which compensates the $6^{th}$ harmonics in the synchronous rotating frame is proposed. This method does not require any off-line experimental measurements, additional hardware and complicated mathematical computations. Furthermore, the proposed method is easy to implement and does not cause any stability problem.

A Gain Control Algorithm of Low Computational Complexity based on Voice Activity Detection (음성 검출 기반의 저연산 이득 제어 알고리즘)

  • Kim, Sang-Kuyn;Cho, Woo-Hyeong;Jeong, Min-A;Kwon, Jang-Woo;Lee, Sangmin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.924-930
    • /
    • 2015
  • In this paper, we propose a novel approach of low computational complexity to improve the speech quality of the small acoustic equipment in noisy environment. The conventional gain control algorithm suppresses the noise of input signal, and then the part of wide dynamic range compression (WDRC) amplifies the undesired signal. The proposed algorithm controls the gain of hearing aids according to speech present probability by using the output of a voice activity detection (VAD). The performance of the proposed scheme is evaluated under various noise conditions by using objective measurement and yields superior results compared with the conventional algorithm.

An Efficient UEP Transmission Scheme for MIMO-OFDM Systems (MIMO-OFDM 시스템을 위한 효율적인 UEP 전송기법 제안)

  • Lee, Heun-Chul;Lee, Byeong-Si;Sundberg, Carl-Erik W.;Lee, In-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5C
    • /
    • pp.469-477
    • /
    • 2007
  • Most multimedia source coders exhibit unequal bit error sensitivity. Efficient transmission system design should therefore incorporate the use of matching unequal error protection (UEP). In this paper, we present and evaluate a flexible space-time coding system with unequal error protection. Multiple transmit and receive antennas and bit-interleaved coded modulation techniques are used combined with rate compatible punctured convolutional codes. A near optimum iterative receiver is employed with a multiple-in multiple-out inverse mapper and a MAP decoder as component decoders. We illustrate how the UEP system gain can be achieved either as a power or bandwidth gain compared to the equal error protection system (EEP) for the identical source and equal overall quality for both the UEP and EEP systems. An example with two/three transmit and two receive antennas using BPSK modulation is given for the block fading channel.

Dynamic Magnetostriction Characteristics of an Fe-Based Nanocrystalline FeCuNbSiB Alloy

  • Chen, Lei;Li, Ping;Wen, Yumei
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.211-215
    • /
    • 2011
  • The dynamic magnetostriction characteristics of an Fe-based nanocrystalline FeCuNbSiB alloy are investigated as a function of the dc bias magnetic field. The experimental results show that the piezomagnetic coefficient of FeCuNbSiB is about 2.1 times higher than that of Terfenol-D at the low dc magnetic bias $H_{dc}$ = 46 Oe. Moreover, FeCuNbSiB has a large resonant dynamic strain coefficient at quite low Hdc due to a high mechanical quality factor, which is 3-5 times greater than that of Terfenol-D at the same low $H_{dc}$. Based on such magnetostriction characteristics, we fabricate a new type of transducer with FeCuNbSiB/PZT-8/FeCuNbSiB. Its maximum resonant magnetoelectric voltage coefficient achieves ~10 V/Oe. The ME output power reaches 331.8 ${\mu}W$ at an optimum load resistance of 7 $k{\Omega}$ under 0.4 Oe ac magnetic field, which is 50 times higher than that of the previous ultrasonic-horn-substrate composite transducer and it decreases the size by nearly 86%. The performance indicate that the FeCuNbSiB/PZT-8/FeCuNbSiB transducer is promising for application in highly efficient magnetoelectric energy conversion.

A Study on Robustness Improvement of the Semiconductor Transmitter and Receiver Module By the Bias Sequencing and Tuning the Switching Time (바이어스 시퀀스와 스위칭 타임 튜닝을 통한 반도체 송수신 모듈의 강건성 향상에 대한 연구)

  • Yoo, Woo-Sung;Keum, Jong-Ju;Kim, Do-Yeol;Han, Sung
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.251-259
    • /
    • 2016
  • This paper describes that how to enhance the robustness of semiconductor TRM(Transmitter and Receiver Module) through the bias sequencing and tuning the switching time. Previous circuit designs focused on improving the MDS(Minimum Detection Signal) performance. Because TRM has critical problem which transmission output signal leak into receiver by it's compact design. Under this condition, TRM was frequently broken down within the MTBF(Mean Time Between Failure). This study proposes the bias sequencing and tuning the switching time to improve above problem. At first, we collected major failure symptom and infer it's cause. Second, we demonstrated it's effect by derive the improvement method and apply it to our system. And finally we can convinced that the proposed method clear the frequent failure problem with its lack of isolation.

Influence on Platycodon grandiflorum Absorption of Nitrogen and Phosphorous Acid and Growth during Seedling Stage by Liquid Fertilizers Treatment (도라지 유묘기 액비처리가 질소와 인산의 식물체 흡수 및 생육에 미치는 영향)

  • Lee, Cheol-Ho;Lee, Shin-Woo;Ahn, Mi-Jeong;Cho, Kwang-Bok;Lee, Hyub
    • Korean Journal of Medicinal Crop Science
    • /
    • v.19 no.4
    • /
    • pp.227-232
    • /
    • 2011
  • The roots of Platycodon grandiflorum has been widely used as a crude drug or a food stuff. Unfortunately, the output and the quality is not regular and highly dependent on the cultivation area and cultivation method. Therefore, seedling cultivation study of this plant under structure with various fertilizer supply was performed. As a result, significant big difference between ammonia nitrogen and nitrate nitrogen content was shown in the root at seedling stage while the difference was not significant in the aerial parts. Fresh weight of the root (7.73 g plant$^{-1}$) was higher in the group treated with three major nutrients (N, P and K) than in those treated with three major nutrients and calcium or magnesium or both calcium and magnesium, and non-treated group (2.69 g plant$^{-1}$). Total nitrogen content was recognized to be significantly correlated with root weight, plant height, number of leaves and weight of aerial parts. Ammonium nitrogen content was more correlated the growth of P. grandiflorum than nitrate nitrogen. For phosphoric acid, significant correlation was also shown with the four growth factors.

Automatic Post Editing Research (기계번역 사후교정(Automatic Post Editing) 연구)

  • Park, Chan-Jun;Lim, Heui-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.1-8
    • /
    • 2020
  • Machine translation refers to a system where a computer translates a source sentence into a target sentence. There are various subfields of machine translation. APE (Automatic Post Editing) is a subfield of machine translation that produces better translations by editing the output of machine translation systems. In other words, it means the process of correcting errors included in the translations generated by the machine translation system to make proofreading. Rather than changing the machine translation model, this is a research field to improve the translation quality by correcting the result sentence of the machine translation system. Since 2015, APE has been selected for the WMT Shaed Task. and the performance evaluation uses TER (Translation Error Rate). Due to this, various studies on the APE model have been published recently, and this paper deals with the latest research trends in the field of APE.

An implementation of 60W X-band Cascade SSPA for Marine Radar System (선박 레이다용 60W X-band Cascade SSPA 구현)

  • Kim, Min-Soo;Jang, Yeon-Gil;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • In this paper, An X-band solid state power amplifier(SSPA) for pulse compressed microwave signal with 60Watt power and power added efficiency(PAE) above 30% is described. Designed 60Watt high power amplifier(HPA) was implemented by cascade coupled amplifiers, and it is consisted on three stage drive amplifiers with internally matched GaAs FET and one stage main power amplifier with an internally matched GaN HEMT. The designed SSPA has performance with more than total power gain 37dB and output power 48dBm(60-W) in condition of frequency range $9.41{\pm}0.03GHz$, pulse period width under 1ms and duty cycle under 10%. The implemented SSPA can apply to high quality digital marine radar applications with pulse compression technique.

A FSK Radio-telemetry System for Monitoring Vital Signs in UHF Band (UHF 대역 FSK에 의한 생체신호 무선 전송장치의 개발)

  • Park D.C.;Lee H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.255-260
    • /
    • 2000
  • This paper presents a radio-telemetry patient monitor. which is used for intensive cal?e units. emergency and surgical operation rooms to monitor continuously patients' vital signs. The radio-telemetry patient monitor consists of a vital sign acquisition unit. wireless data transmission units and a vital sign-monitoring unit. The vital sign acquisition unit amplifies biological signals, performs analog signal to serial digital data conversion using the one chip micro-controller. The converted digital data is modulated FSK in UHF band using low output power and transmitted to a remote site in door. In comparison with analog modulation. FSK has major advantages to improve performance with respect to noise resistance with fower error and the potential ability to process and Improve quality of the received data. The vital sign-monitoring unit consists of the receiver to demodulate the modulated digital data, the LCD monitor to display vital signs continuously and the thermal head printer to record a signal.

  • PDF