• Title/Summary/Keyword: Quality Management Plan

Search Result 1,080, Processing Time 0.027 seconds

수입검사(受入檢査)의 경제성(經濟性)에 관한 연구(硏究) - 계수형(計數型)샘플링검사(檢査)를 중심(中心)으로 -

  • Kim, Gwang-Seop;Lee, Gyeong-Hak
    • Journal of Korean Society for Quality Management
    • /
    • v.7 no.1
    • /
    • pp.26-34
    • /
    • 1979
  • This paper intends to decide the optimum OC curves and to find the minimized ${\alpha},{\beta}$-risk based upon the Linear Cost Model (L. C. M.) for the destructive or nondestructive acceptance sampling inspection plan. For the solution from the L. C. M., the author used the prior-distribution on some assumptions.

  • PDF

Economic design of a pn control charts using loss-cost function (손실비용함수를 이용한 pn관리도의 경제적인 설계)

  • Lee, Yeong-Sik;Hwang, Ui-Cheol
    • Journal of Korean Society for Quality Management
    • /
    • v.18 no.1
    • /
    • pp.77-83
    • /
    • 1990
  • A model for the economic design of an pn control charts with an assignale cause is presented and the loss-cost function for control schemes using these charts is derived. By minimizing this function with respect to the three control variables, namely, the sample size, the sampling interval and acceptance number, the economically optimal control plan can be optained. The article shows what influence increasing or decreasing condition, according to changeability of the size of these factors, of expected cost can have on the economy when an attribute control chart is used.

  • PDF

Study in the integrated watershade management for conservation of water resources(I) - Water Quality distribution and Environmental capacity of the Samchog Buk stream, Oship stream, Gagog stream nearby eastern coastal - (수자원 보전을 위한 유역통합관리 방안에 관한 연구(I) - 동해안 유역의 북천, 오십천, 가곡천 수계의 수질 및 환경용량 평가)

  • 허인량;정의호;권재혁
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.51-60
    • /
    • 2002
  • Concerning the water quality management plan about Buk-stream, Ohsip-stream and Gagok-stream water systems in this research, which objectives of abstract is as follows. The result of cleanness degree evaluation of water quality in this research, the first grade was 91% shared in Buk-stream water system. The most point of the middle and upper stream of Buk-stream was maintain extremely clean water quality. Among the researched water system, the first grade of water quality in Ohsip-stream water system was most poor, its first garde rate was 68%. In all water quality check point of Gagog-stream water system was accomplished extremely clean water quality condition of first grade of BOD. The calculation result of pollutant loading density, which were 8.2, 21.5, 4.0kg/day.$\textrm{km}^2$. respectively and basin of Buk-stream and Gagok-Stream have high development potentiality.

Development of Database System for Management of Quality Control for Earthworks (토공노반 다짐품질관리를 위한 DB개발소개)

  • Choi, Chan-Yong;Bae, Jae-Hoon;Lee, Jin-Wook
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1848-1852
    • /
    • 2008
  • Maintenance of quality of the compaction is accomplished with the plate load test and density management in roadbed. With the different structure differently the quality of roadbed evaluates indirectly as density and bearing capacity. Control of quality of the compaction very importance but the maintenance of quality is managed still so far with the paper. Recognizes the importance of maintenance of quality from the present paper consequently, and develops a data base one maintenance of quality system with hereafter is expected with the fact that the big help will become in DATA BASE system roadbed plan which is continuous and maintenance of quality.

  • PDF

The Change of Safety Management and the Safety Counter-plan (안전관리와 예비대책 변화 방향)

  • 서지한;서광규;고용해
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.05a
    • /
    • pp.15-21
    • /
    • 2002
  • In the future, all kinds condition of industrial safety is a primary need in all advanced countries in which workplace safety is an issue. Furthermore, the increasing complexity of production systems and the rapidity of technological innovation have consolidated the recognition of the strategic value of safety, alongside the traditional competitive factors such as quality, costs, delivery time and flexibility, In this paper, the some critical issues of changes and counter-plan in an adequate safety management were identified by above considerations as follows: needs of systematic identification and analysis of safety factors; requirements to define priorities and budgeting to support the decision-making process; and needs of audit activities and indicators which measure company performance in terms of safety improvements, and so on.

  • PDF

An Analysis of Relationships among Quality, Satisfaction and Utilization Perceived by Family Caregivers in Standard LTC Utilization Plan (가족수발자가 인지하는 표준장기요양이용계획서의 질과 만족도, 활용도 간의 관계분석)

  • Lee, Jung-Suk;Han, Eun-Jeong;Kwon, Jinhee
    • 한국노년학
    • /
    • v.31 no.4
    • /
    • pp.871-884
    • /
    • 2011
  • Standard Long-term care(LTC) Utilization Plan is a kind of care plan, which aims to help beneficiaries and their family choose services to meet their care needs. The objective of this study is to determine the relationships among family caregivers' perceived quality, overall satisfaction and utilization in Standard LTC Utilization Plan. Data were gathered from family caregivers with beneficiaries who have used community service in long-term care insurance system. A national cross-sectional descriptive survey was conducted in December 2008, using proportionate quota sampling. Finally, 351 family caregivers completed questionnaires which included demographic characteristics, perceived quality(9 items), overall satisfaction(1 item) and utilization(2 items). Path analysis was conducted to find a causal relationship. This study shows firstly, the quality of Standard LTC Utilization Plan was categorized into three dimensions, that is, assessment of care needs, recommended care plan, and management of monthly benefits. Secondly, reliability and validity of quality items were satisfied. Finally, in the effect of perceived quality and satisfaction for utilization, assessment of care needs(indirect effect, path coefficients=0.077) and overall satisfaction(total effect, path coefficients=0.324) were statistically significant. The findings of this study would be helpful in developing the strategies, which is needed to improve the role of Standard LTC Utilization Plan.

Analysis of the Impact of Construction Planning Tasks on Project Cost and Schedule Success in Residential Projects (공동주택 설비공사 계획업무의 성과지표에 미치는 영향분석)

  • Kim, Dae Young;Lim, Hyoungchul;Kim, Daeyoung;Huh, Youngki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.31-38
    • /
    • 2019
  • The main purpose of this study is to analyze the impact of the cost estimates on the construction work in residential apartment housing facilities. The planning work of facility construction is roughly divided into five main tasks which are further broken down into the following: process plan (P1-P6), construction plan (C1-C5), environmental management plan (E1-E4), quality management plan (Q1-Q5) and the safety management plan (S1-S5). In this study these tasks were classified into 25 detailed planning duties and a statistical analysis was performed on each one to determine its impact on cost. Finally this study derives from major planning tasks for effective cost management through correlation between planning tasks, cost indicators and t-test.

Excessive State of Pollutant Load Allocation and Penalty Application Schemes based on Pollutant Reduction Plan Types for Solving Excessive Problem of Allocation (오염할당부하량의 초과현황 및 초과해소를 위한 삭감계획 유형에 따른 페널티 적용방안)

  • Park, Jae Hong;Park, Bae Kyoung;Oh, Seung Young;Hwang, Ha Sun;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.66-73
    • /
    • 2013
  • Total Maximum Daily Loads (TMDLs) system was introduced to manage pollution load of watershed and to improve water quality of unit watershed so that it is possible to protect dringking water soureces. Load allocation observation is the most important factor in TMDLs system. Because if load allocation is not observed, it is difficult to achieve water quality goal of unit watershed. Also it is impossible to improve water quality of the drinking water sources. Therefore it is necessary to apply some kind of sanctions (penalty) in case of excess of load allocation. The sanctions have to be, however, applied differently based on various reduction plan types, i.e., using the reduction load planed in 2nd phase, delay the completion, additional reduction in 2nd phase, error of the pollution sources, etc. Moreover, the penalty load should be properly imposed, lest it should be overburden the provence. The reduction load trade inter province must be restrictively permmitted only the same unit watershed.

A Study on Optimal Operation Conditions for an Electronic Device Alignment System by Using Design of Experiments (실험계획법을 이용한 전자부품 위치정렬장치 최적 운영조건 사례연구)

  • Lee, Dong Heon;Lee, Mi Lim;Bae, Suk Joo
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.453-466
    • /
    • 2015
  • Purpose: The purpose of this study is to design a systematic method to estimate optimal operation conditions of design variables for an electronic device alignment system. Method: The 2-level factorial design and the central composite design are used in order to plan experiments. Based on the experiment results, a regression model is established to find optimal conditions for the design variables. Results: 3 of 5 design variables are selected as major factors that affect the alignment system significantly. The optimized condition for each variable is estimated by using a sequential experiment plan and a quadratic regression model. Conclusion: The method designed in this study provides an efficient and systematic plan to select the optimized operation condition for the design variables. The method is expected to improve inspection accuracy of the system and reduce the development cost and period.