• 제목/요약/키워드: Quality Factor(Q)

검색결과 459건 처리시간 0.027초

$Fe_2O_3$ 첨가에 따른 $Pb(Y_{1/2}Ta_{1/2})O_3-PbZrO_3-PbTiO_3$ 세라믹스의 전기적 특성 (Electrical Properties of $Pb(Y_{1/2}Ta_{1/2})O_3-PbZrO_3-PbTiO_3$ Ceramic s as a function of $Fe_2O_3$content)

  • 강도원;김태열;김범진;박태곤;김명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.297-299
    • /
    • 1999
  • Effects of additives on the ceramic and electrical properties of Pb(Y$_{1}$2/Ta$_{1}$2/)O$_3$-PbZrO$_3$-PbTiO$_3$ceramics in a perovskite type structure were investigated. The dielectric and piezoelectric properties of the base composition were improved markedly through selection of Fe$_2$O$_3$ additives in proper amounts. The composition Pb(Y$_{1}$2/Ta$_{1}$2/)O$_3$-PbZrO$_3$-PbTiO$_3$ obtained the dielectric constant ($\varepsilon$$_{r}$=1,425). Also, electromechanical couping factors for planar(k$_{p}$) and piezoelectric constant(d$_{33}$) were obtained 0.50 and 294[pC/N] at the additives 0wt% Fe$_2$O$_3$ respectively. The mechanical quality facor(Q$_{m}$) of Pb(Y$_{1}$2/Ta$_{1}$2/)O$_3$-PbZrO$_3$-PbTiO$_3$+Fe$_2$O$_3$(0.3 wt%) is about 510.510.510.

  • PDF

PMWN-PZT계 압전세라믹의 압전 및 유전특성 (Characteristics of Piezoelectric and dielectric of PMWN-PZT Ceramics)

  • 홍종국;이종섭;채홍인;윤만순;정수현
    • 한국전기전자재료학회논문지
    • /
    • 제14권6호
    • /
    • pp.455-459
    • /
    • 2001
  • In this paper, the dielectric and pizoelectric properties of 0.05Pb(M $n_{04}$ $W_{0.2}$N $b_{0.4}$) $O_3$-0.95(PbZ $r_{x}$ $Ti_{1-x}$ ) $O_3$+yN $b_2$ $O_{5}$ , are investigated as a function of the mole ratio of Zr and the amount of N $b_2$ $O_{5}$ . Also, the phase is analyzed by XRD. When the mole ratio of Zr is 0.51, the electromechanical coupling coefficient( $k_{p}$ ), relative dielectric constant ($\varepsilon$$^{T}$ $_{33}$ /$\varepsilon$$_{0}$ ), piezoelectric stain constrain ( $d_{33}$ and dielectric loss tangent show maximum, while the mechanical quality factor shows minimum value ; $k_{p}$ =56.5%, $d_{33}$ =258pC/N, $\varepsilon$$^{T}$ $_{33}$ /$\varepsilon$$_{0}$ =1170, $Q_{m}$ =1150, tan$\delta$=0.51%. At that composition, MPB which rhombohedral and tetragonal phase coexist in this ternary system is shown by the results of XRD analysis. Also, when the amount of N $b_2$ $O_{5}$ is 0.3wt%, the mechanical quality factor is increased to about 2000. The phase transition temperature of the ternary piezoelectric ceramic system showed about 35$0^{\circ}C$.TEX>.>.>.

  • PDF

광-유체링공진기(OFRR) 바이오센서에 관한 공진이동과 양호도의 시뮬레이션 (Simulation of Resonance Shift and Quality Factor for Opto-fluidic Ring Resonator (OFRR) Biosensors)

  • 조한근;한진우;양길모
    • Journal of Biosystems Engineering
    • /
    • 제36권1호
    • /
    • pp.23-32
    • /
    • 2011
  • In this work, the finite element method was used to investigate the shifts of resonance frequencies and quality factor of whispering-gallery-mode (WGM) for an opto-fluidic ring resonator (OFRR) biosensor. To describe the near-field radiation transfer, the time-domain Maxwell's equations were employed and solved by using the in-plane TE wave application mode of the COMSOL Multiphysics with RF module. The OFRR biosensor model under current study includes a glass capillary with a diameter of 100 mm and wall thickness of 3.0 mm. The resonance energy spectrum curves in the wavelength range from 1545 nm to 1560 nm were examined under different biosensing conditions. We mainly studied the sensitivity of resonance shifts affected by changes in the effective thickness of the sensor resonator ring with a 3.0 mm thick wall, as well as changes in the refractive index (RI) of the medium inside ring resonators with both 2.5 mm and 3.0 mm thick walls. In the bulk RI detection, a sensitivity of 23.1 nm/refractive index units (RIU) is achieved for a 2.5 mm thick ring. In small molecule detection, a sensitivity of 26.4 pm/nm is achieved with a maximum Q-factor of $6.3{\times}10^3$. These results compare favorably with those obtained by other researchers.

Microwave Dielectric Characteristics of Aluminum Magnesium Tantalate Based High Q Ceramics

  • Park, Ji-Won;Lee, Hwack-Joo;Yoon, Seok-Jin;Kim, Hyun-Hai
    • 한국세라믹학회지
    • /
    • 제40권4호
    • /
    • pp.354-359
    • /
    • 2003
  • The microwave dielectric characteristics of (1-x)(Al$\_$$\frac{1}{2}$/Ta$\_$$\frac{1}{2}$/)O$_2$-x(Mg$\_$1/3/Ta$\_$2/3/)O$_2$ (0$\leq$x$\leq$1.0) ceramics were investigated by crystalstructure, variations of ionic polarizability, and microstructures. As x increased, (1-x)(Al$\_$$\frac{1}{2}$/Ta$\_$$\frac{1}{2}$/)O$_2$-x(Mg$\_$1/3/Ta$\_$2/3/)O$_2$ transformed to tetragonal structure. Because the ionic radius of (Mg$\_$1/3/Ta$\_$2/3/)$\^$4+/was slightly bigger than one of (Al$\_$$\frac{1}{2}$/Ta$\_$$\frac{1}{2}$/)$\^$4+/, the cell parameters increased with increase of (Mg$\_$1/3/Ta$\_$2/3/)O$_2$concentration and coincided with prediction of the molecular additivity rule. As x increased, the compositions revealed ordered phase and were of single phase above 60 mol%. The increase of the ordered phase and grain size enhanced the Q and when ordering was completed at x over 0.6, the grain size was major factor for the increase in the a. Though the grain size increased, however, the porosity deteriorated the q. Therefore, the a depended on the order/disorder, the porosity, and the grain size in regular order.

나선형 인덕터를 이용한 VCO 최적설계 (Optimal Design of VCO Using Spiral Inductor)

  • 김영석;박종욱;김치원;배기성;김남수
    • 대한전자공학회논문지SD
    • /
    • 제39권5호
    • /
    • pp.8-15
    • /
    • 2002
  • 나선형 인덕터를 이용한 VCO를 MOSIS의 HP 0.5㎛ CMOS 공정으로 최적 설계하고 제작하였다. 나선형 인덕터의 SPICE 모델을 이용하여, Q지수(qualify factor)를 동작 주파수에서 최대화하기 위하여 레이아웃 변수인 금속선 폭, 회전수, 내경, 간격 등을 최적화하였다. 만약 동작주파수가 2㎓, 인덕턴스가 약 3nH이고, 금속선 두께 0.8㎛, 절연 산화막 두께 3㎛를 사용하는 MOSIS HP 0.5㎛ CMOS 공정의 경우 금속선 폭은 20 정도로 하는 것이 Q지수를 최대로 함을 확인하였다. 이렇게 최적화된 나선형 인덕터를 LC 공진 탱크에 사용하여 VCO를 설계, 제작 및 측정을 하였다. 측정은 온웨이퍼(on-wafer)상에서 HP8593E 스펙트럼 에널라이저를 이용하였다. 발진신호의 주파수는 약 1.61㎓이고, 컨트롤전압이 0V -2V변화할 때 발진주파수는 약 250㎒(15%) 변화하였으며, 출력 스펙트럼으로부터 중심주파수 1.61㎓에서 offset 주파수가 600㎑ 때의 위상잡음이 -108.4㏈c/㎐ 였다.

지지간호가 만성질환자의 삶의 질과 자존감에 미치는 효과 -류마티스양 관절염을 중심으로- (The effect of supportive nursing care on the quality of life and self-esteem of persons with rheumatoid arthritis)

  • 김명자;송경애
    • 대한간호학회지
    • /
    • 제21권3호
    • /
    • pp.323-338
    • /
    • 1991
  • This study investigated the effect of supportive nursing care including modified guided imagery on the discomfort, self- esteem, erythrocyte semdimentation rate(ESR) and quality of life(Q. L.) in persons with rheumatoid arthritis (R. A.). The purpose was to contribute to the development of theoretical nursing care to enhance the Q. L. of persons with chronic illness. From Nov. 22, 1990 to May 2, 1991, 49 patients registered at a rheumatic clinic at one general hospital in Seoul, were accepted according to the research criteria as subjects for this study. Among these, 26 were selected for an experimental group to he treated with an interpersonal interview and modified guided imagery, the other 23 became the control group not treated for the purpose of measuring and comparing the effect of the treatment. Statistical analysis was done by a SAS program for X$^2$-test, unpaired t -test, Pearson correlation coefficients and factor analysis. The results were as follows : 1. The pre-experimental discomfort level of the total subject group averaged 25.42(S. D. =8.77), and the difference between the pre /post experimental discomfort levels of the two groups was not statistically significant. 2. The pre - experimental self- esteem scores of the total subject group averaged 27.48(S. D. =3.95), and the difference between the pre /post experimental self -esteem scores of the two groups was not statistically significant. 3. The pre - experimental Q. L. scores of the total subject group averaged 28.70(S. D. =5.99), and the difference between the pre /post experimental Q. L. score of the two groups was statistically significant (t=2.1748, df=47, p= .0347), 4. The pre - experimental mean of the ESR of the total subject group was 34.48(S. D. =19.50) mm, and the difference between the pre /post expeimental ESR scores of the two groups was not statistically significant. 5. The Family support scores of the total subject group averaged 41.28(S. D. =10.27). 6. The total subject group 0.L. score was correlated with self-exteem score (r= .3984, p= .0046). In this study, supportive nursing care including modified guided imagery increased the quality of life scores for this group of persons with R. A. significantly. So the concept of supportive nursing care of this study may be effective in enhancing the quality of life persons with chronic illness. Further investigations related to the methodology and with other groups of clients was recommended.

  • PDF

Co90Fe10/SiO2 Multilayer를 이용한 GHz 자성박막 인덕터 설계 및 제작에 관한 연구 (A Study on the Design and Fabrication of GHz Magnetic Thin Film Inductor Utilizing Co90Fe10/SiO2 Multilayer)

  • 공기준;윤의중;진현준;박노경;문대철
    • 한국통신학회논문지
    • /
    • 제25권5B호
    • /
    • pp.985-991
    • /
    • 2000
  • 본 논문에서는 인덕터의 면적을 극소화시키고 인덕턴스와 Q값을 극대화시키기 위한 최적구조의 2GHz 자성박막 인덕터를 설계하고 제작하였다. Eddy-current 표피효과를 위해서 Co90Fe10와 SiO2의 multilayer를 사용하고, multilayer를 적용한 새로운 lumped 소자모델을 고려하여 최적설계를 수행하였다. 2GHz에서 동작하는 새로운 자성박막 인덕터는 photo-lithography와 lift-off기술을 이용하여 Si 기판위에 제작되었다. 50개 이상의 동일한 인덕터들의 주파수 특성은 RF Impedance Analyzer로, 자기공진주파수는 Vector Network 분석기(HP8510)로 측정되었다. 개발된 인덕터들은 1.8~2.3GHz 범위의 자기공진주파수, 47~68nH 범위의 L값, 그리고 1GHz이상의 주파수에서 70~80정도의 Q값을 가지므로 L과 Q가 극대화된 아주 우수한 최적구조의 소형(면적=30.8$\times$30.8mil2) 박막인덕터가 성공적으로 제작되었다.

  • PDF

직무긴장 모형을 이용한 치과위생사의 직무스트레스와 반응 (Job stress and reaction of dental hygienist by using the job strain model)

  • 최미숙;안권숙
    • 한국치위생학회지
    • /
    • 제10권4호
    • /
    • pp.595-605
    • /
    • 2010
  • Objectives : A precedent research has documented that occupational stress is closely associated with increased the risk of fatigue and decreased in job satisfaction. This study was conducted in an effort to assess the relationship of occupational stress to self-perceived fatigue and job satisfaction by using job strain model. Methods : The number of respondents was 122 dental hygienist who work in dental clinic and period of the investigation was July 2009 through september 2009. A structured questionnaire was employed to evaluate the participants' sociodemographics, job-related factors, health-related behaviors, occupational stress, job satisfaction and self-perceived fatigue. Occupational stress and self-perceived fatigue were assessed using the Korean Occupational Stress Scale-Short form (KOSS-SF) and the Multidimensional Fatigue Scale (MFS), respectively. Results : In job strain model, the ratio of Q2(High Strain Job) group that more susceptible to disease by stress than other group was 16% and the proportion of high fatigue group(Q3, Q4 group) and low job satisfaction group(Q3, Q4 group) was 48%, 45% respectively. In logistic regression analyses, a High Strain Job group was associated with higher odds of react factor(fatigue, job satisfaction) and the odds was down by 3.3%~7.5% after adjustment for age, smoking, alcohol drinking, regular exercise. So the effective strategy for fatigue, job satisfaction reduction for dental hygienist requires additional program focusing on innovated work environment that provide a enough leisure time and exercise program considering the personality traits. Conclusions : The results of this study suggest that occupational stress is a determinant predictor of self perceived fatigue and job satisfaction. Thus, a stress management program for the reduction of occupational stress, and the promotion of dental hygienist impact assessment health and quality of life is strongly recommended.

QEFD를 활용한 제품 환경효율성 측정 사례 연구 (A Case Study of Measuring Eco-Efficiency of Products Using the QEFD Approach)

  • 홍승용;박승욱;김연복;김종대
    • 품질경영학회지
    • /
    • 제41권2호
    • /
    • pp.197-208
    • /
    • 2013
  • Purpose: This study proposed a systematic approach to measure eco-efficiency of products based on the concept of quality function deployment(QFD). QFD method has been used to convert customer's subjective requirements to design specifications. A extension of QFD to environmental issues is known as quality environmental function deployment(QEFD). QEFD includes environmental requirements into customer's demand for quality, and incorporates them to design specifications of a product. Methods: In this study, we compared eco-efficiency of old and new models through application of QEFD. Results: The result revealed that the new model's eco-efficiency improved 24% better than the old model. Also, we found that user's Factor X of the new model has been improved to 1.178, which is about 18% better than that of the old model. Conclusion: This study implied that we can systematically use QEFD to determine eco-efficiency of two comparable products in any industries.

A Study on the Detection Algorithm of an Advanced Ultrasonic Signal for Hydro-acoustic Releaser

  • Kim, Young-Jin;Huh, Kyung-Moo;Cho, Young-June
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.767-775
    • /
    • 2008
  • Methods used for exploring marine resources and spaces include positioning a probe under water and then recalling it after a specified time. Hydro-acoustic Releasers are commonly used for positioning and retrieving of such exploration equipment. The most important factor in this kind of system is the reliability for recalling the instruments. The frequently used ultrasonic signal detection method can detect ultrasonic signals using a fixed comparator, but because of increased rates of errors due to outside interferences, information is repetitively acquired. This study presents an effective ultrasonic signal detection algorithm using the characteristics of a resonance and adaptive comparator Combined with the FSK+ASK modulator. As a result, approximately 8.8% of ultrasonic wave communication errors caused by background noise and transmission losses were reduced for effectively detecting ultrasonic waves. Furthermore, the resonance circuit's quality factor was enhanced (Q = 120 to 160). As such, the bias voltage of the transistor (Vb= 3.3 to 6.8V) was increased thereby enhancing the frequency's selectivity.