• 제목/요약/키워드: Quality Efficiency Evaluation

검색결과 754건 처리시간 0.029초

Cone-ratio DEA에 의한 우편집중국 효율성 분석 (Efficiency Analysis for Mail Centers Using Cone-Ratio DEA)

  • 이재설;고현우
    • 산업경영시스템학회지
    • /
    • 제33권1호
    • /
    • pp.10-16
    • /
    • 2010
  • Mail centers are essential postal facilities that sort and dispatch postal items, and should be operated efficiently to provide customers high quality postal services. So the efficiency analysis of mail centers should be performed in order to induce better operation. But current performance evaluation system has 95 percent of predetermined and weighted non-quantitative indices. There is need to introduce objective efficiency measurement methodology. The main objectives of this study was to analyze the efficiency of 24 mail centers empirically using cone-ratio DEA and suggest the appropriate cone-ratio method. Consequently, this paper suggests that the cone-ratio DEA model integrating decision-maker's preferences is more desirable for efficiency analysis than that of using transformed data.

버스정보시스템의 효율성에 관한 연구 (The Study of Bus Information System's Efficiency)

  • 이정근;최석우;황병옥
    • 한국ITS학회 논문지
    • /
    • 제5권3호
    • /
    • pp.1-12
    • /
    • 2006
  • 현재 각 지자체별로 ITS 시스템이 도입되고 있으며 대시민 서비스차원에서 버스정보시스템(BIS)이 우선적으로 도입, 운영되고 있다. 이러한 버스정보시스템의 대표적인 위치추적 및 무선통신방식으로 DSRC+DSRC방식, GPS+무선통신망, Beacon+Beacon이 각 지자체별 특성에 맞게 구축, 운영중에 있다. 지금까지 BIS 시스템에 대한 평가는 각 지자체별로 사전, 사후분석의 설문조사항목을 통해 정성적 평가만 수행되었으며 시스템의 성능에 대한 평가는 실시되지 않았다. 따라서 본, 논문은 현재까지의 시행하였던 BIS 시스템에 대한 평가방안을 기초로 성능평가를 포함한 새로운 평가방안을 수립하여 각 BIS 방식별 대표시스템을 선정, 도착정보 신뢰도와 무선통신성공율의 효과척도를 적용하여 해당 시스템의 신뢰도나 효율성에 대한 평가를 수행하였다.

  • PDF

활성탄을 첨가한 콘크리트벽돌의 물리적 특성 및 환경 성능 평가에 관한 연구 (A Study on the Physical Properties and Environment Efficiency Evaluation in Activated Carbon Concrete Bricks)

  • 우종권;홍상희;전경빈;류현기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.47-51
    • /
    • 2006
  • Modern residing equipment developed much quantitatively along with economic growth but improvement for agreeable residing space of indoor environment is insufficient situation yet. Also, the latest sick-building syndrome discharging room contaminant such as Formaldehyde, toluene, radon etc. built house or buildings newly human body threaten. Radon of them is real condition that raise origination of lung cancer next to smoke. So, wish to in this research by one of solution way of these problems adsorption performance and specie performance excellent activated carbon to concrete bricks for deconstipating suppository that is room finish fare mix and examine closely after grasp physical, mechanical special quality, hazardous substance and specie performance effect. According to result that estimate environment efficiency evaluation, the $CO_2$ absorption amount displayed decrease effect more than about 90% in activated carbon metathesis rate 40% and radon release amount displayed tendency that decrease about $76{\sim}96%$ in activated carbon metathesis rate 40%.

  • PDF

품질시스템의 효과적인 운영을 위한 평가모형에 관한 연구 (An Evaluation Model for the Effective Implementation of a Quality System)

  • 김중배;강창욱
    • 산업경영시스템학회지
    • /
    • 제21권45호
    • /
    • pp.155-163
    • /
    • 1998
  • Recently, as the quality is being recognized as elementary and strategic means to improve the international competetiveness of a business, there may be few business who do not operate quality control meeting or system for their production lines. In other words, local businesses operate some types of quality control system half voluntarily and half compulsorily without having verifying their efficiency. Under such a circumstance, this study is aimed at determining the factors which local businesses are required to assess for their quality system. It is believed that the results of this study can be used as a tool for local businesses to assess their quality system. The effective identification of problems regarding the quality system depends on how precisely the activities of quality system can be performed. Upon correct identification of problems, desirable directions can be explored. All in all, the model developed through this study may be useful as quality system assessment tool.

  • PDF

3주기 및 4주기 교원양성기관 평가 후 전국 대학 유아교육과 효율성 분석 (An Analysis of Change in Efficiency of Department of Early Childhood Education in KOREA)

  • 송운경;송연경
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.517-529
    • /
    • 2021
  • 본 연구의 목적은 전국 대학 유아교육과의 효율성 변화를 분석하여 교원양성기관 역량진단의 효과성을 살펴보고, 효율적인 유아교육과와 비효율적인 유아교육과의 특성 및 효율성에 영향을 끼치는 변수들을 확인하여 정책적인 시사점을 제공하는 데에 있다. 연구목적을 위해 전국 대학 유아교육과 149개 데이터를 사용하여 자료포락분석을 실시, 교원양성기관 평가 완료 이전의 효율성 연구결과와 비교분석하였다. 불변규모수익기술과 가변규모수익기술을 가정한 산출지향 모형을 추정하여 CCR과 BCC모형으로 상대적 운영효율성 추정하였고, 투입요소로는 전임교원 1인당 학생 수, 학생 1인당 장학금, 전임교원 1인당 연구비, 학생 1인당 장서 수, 학생 1인당 교육비를 산출요소로는 전임교원 1인당 연구실적, 취업률을 사용하였다. 토빗모형을 통해 투입, 산출요소 및 외생변수(설립유형, 학교종류, 입학정원규모, 소재지) 중 효율성에 영향을 끼치는 요인들을 살펴보았다. 연구결과, 전국 대학 유아교육과는 효율적으로 운영되고 있으며 3주기 및 4주기 교원양성기관 평가 완료 전과 규모효율성과 운영효율성에 차이가 없었다. CCR에서 강효율 유아교육과는 학생 1인당 장학금, 장서 수, 교육비가 유의하게 낮음에도 불구, 유의하게 높은 전임교수 1인당 연구실적과 취업률을 보이나, BCC 아래 학생1인당 장서 수, 취업률 이외에는 통계적 유의성을 상실하며, 토빗모형 계수도 실제적인 영향을 논하기에는 미미하다. 전문대학과 입학정원규모 60명 이상, 광역권 유아교육과의 운영효율성이 높은 것으로 확인되었다. 본 연구결과는 교육의 질적 향상을 통한 효율성 증대를 목적으로 하는 평가정책에 시사점을 준다.

선진국 사례 벤치마킹을 통한 건설공사 사후평가 성과분석 체계 개발 (Performance Analysis Framework for Post-Evaluation of Construction Projects through Benchmarking from Advanced Countries)

  • 이강욱
    • 한국산업융합학회 논문집
    • /
    • 제25권6_2호
    • /
    • pp.1017-1027
    • /
    • 2022
  • Development of social overhead capital (SOC) requires huge national finance, and performance issues such as cost-efficiency, safety, and environment have been constantly raised. However, currently each construction client has limited access to its own projects' performance without analytic methodology for industry-level comparisons and benchmarking for improvement. To overcome this problem, this study proposes a comprehensive performance analysis framework for post-evaluation of large-scale construction projects. To this end, this study performed a case study of advanced countries (the U.S., the U.K. and Japan) and consultation with related experts to develop a tailored performance analysis framework for the Post- Construction Evaluation and Management system in Korea. The developed framework covers three categories (project performance, project efficiency, and ripple effect), nine areas (cost, schedule, change, safety, quality, demand, benefit-cost ratio, civil complaint, and defect), and 31 detailed metrics. Using industry-level project performance database and statistical techniques, the proposed framework can be used not only to diagnose excellent and unsatisfactory performance areas for completed construction projects, but also to provide reference data for future similar projects. This study can contribute to the improvement of clients' performance management practices and effectiveness of construction projects.

입상활성탄 재생온도에 따른 정수처리 효율 평가 (Evaluation of Drinking Water Treatment Efficiency according to Regeneration Temperatures of Granular Activated Carbon (GAC))

  • 김상구;손희종;정종문;류동춘;유평종
    • 한국환경과학회지
    • /
    • 제24권9호
    • /
    • pp.1163-1170
    • /
    • 2015
  • This study carried out continuous column test for estimating the regeneration efficiency with regeneration times and temperatures. More times regenerated granular activated carbon (GAC) has more ash in the GAC and has less apparent density. Two times regenerated GAC ($2^{nd}$ re-GAC) could removed the Trihalomethanes (THMs) in the water for the first two week after starting continuous column test, on the other hand five times regenerated GAC ($5^{th}$ re-GAC) did not have adsorption capacity. The THMs concentration in the effluent was almost equal or higher than that of influent at the first time of continuous column test. $2^{nd}$ re-GAC showed much more DOC adsorption capacity than $5^{th}$ re-GAC and the GAC which was regenerated with $700^{\circ}C$ had highest DOC removal efficiency among the GACs with 600, 700, 800, $900^{\circ}C$ regeneration temperatures. It is anticipated the cost of GAC regeneration could be saved more 100 million won by reducing the furnace temperature of 3rd~4th and 5th~6th about $150^{\circ}C$ compared to the current regeneration condition.

The system of examination of efficiency for competitive project

  • Tom, I.;Krasko, O.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.90-95
    • /
    • 1992
  • Authors have developed the method of selecting the efficient variant of designing a systems or products from a some number of competition variants in the conditions of vagueness of the initial information. Registration of information vagueness degree concerning the quantity index values is carried out of the expense of giving to the expert the possibility of using different methods of index evaluation numerical evaluations with physical scale; phrases of limited language; and points evaluation. Using of this method and software is important for marketing research, for systems of quality control of products.

  • PDF

온라인 후기에 내재된 고객의 감성분석과 LQI 차원별 호텔 서비스 품질 평가 (Hotel Service Quality Evaluation Based on LQI using Sentiment Analysis of Online Reviews)

  • 사공원;하성호;박경배
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제25권3호
    • /
    • pp.217-245
    • /
    • 2016
  • Purpose With the increasing number of foreign travelers visiting Korea, it is a heavy question to evaluate service quality of typical domestic hotel companies. Our research aims to evaluate service quality of domestic hotels in Korea from the perspective of foreign travelers in order to provide the quality improvements that call attention for the hotel management. Design/Methodology/Approach In this paper, topics of sentiment followed Lodging Quality Index(LQI) dimensions classifying lodging service quality appropriately. Also, we employed word2vec algorithm which calculates similarity and affinity among the vocabularies accurately. To calculate sentiment of each dimension, we adopted scores from SentiWordNet. Findings From the result, we found the number of foreign travelers particularly satisfied with cleanliness, politeness, and problem solving skills. In contrast, it has also been found out that both promptness of services and efficiency of communication do not fulfill the requirements of travelers.

PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가 (Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT)

  • 이충운;유연욱;문종운;김윤철
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF