• 제목/요약/키워드: Qmax

검색결과 50건 처리시간 0.032초

섬유의 열전달 특성이 보온용 부직포의 접촉온냉감에 미치는 영향 (The Effects of Heat Transfer Characteristics of Fibers on the Warm/Cool Touch of Insulating Nonwovens)

  • 김희숙
    • 한국생활과학회지
    • /
    • 제8권1호
    • /
    • pp.125-134
    • /
    • 1999
  • The purpose of this study was to investigate the effects of heat transfer characteristics of fibers on the Qmax of insulating nonwovens. The effects of fiber type, moisture content, washing cycles on the Qmax were observed. The correlations between Qmax measured by KES-F7 system and subjective warm/cool touch perception test was analyzed. The results obtained were as followed: 1. Heat transfer characteristics of fibers effected on the Qmax of insulating nonwovens. 2. Moisture transport properties of fibers effected considerably on the Qmax of nonwovens and the increasing rate of Qmax by increasing moisture content was much higher at wool than polyester. 3. As a result of subjective perception test, subjective warm/cool touch and wettness of wool nonwoven was increased obviously by increasing moisture content. 4. At the same moisture content, wool nonwoven showed higher subjective cool touch and wetness than polyester. 5. In the physical properties of nonwovens, thickness was the most effective factor on the Qmax of insulating nonwovens.

  • PDF

요소.포름알데히드 수지가공 셀룰로오스계 직물의 열특성 (The Thermal Characteristics of Cellulose Fabrics Finished with Urea-Formaldehyde Resin)

  • Song, Wha Soon
    • 한국염색가공학회지
    • /
    • 제5권4호
    • /
    • pp.79-91
    • /
    • 1993
  • The purpose of this study is to prepare the newer, more comfortable of urea-formaldehyde resin finished fabrics. The methods of this study are by making examinations and comparisons the relations between the thickness, fabrics counts, weight, moisture regain and crease recovery of cotton and viscose rayon fabrics caused by condition of urea-formaldehyde resin finishing and warm retaining ability and warm-cool sense. The analytic results of thermal character in state of fabrics material finished with urea-formaldehyde are as follows: 1. The warm retaining ability has no correlation with mixing ratio of resin but the increase of the warm retaining ability has correlation with the increase of concentration of urea-formaldehyde resin. 2. The result pf multiple regression analysis for effect of physical property according to the concentration of resin to the warm retaining ability revealed as below. As the weight, thickness and density increase and moisture regain decreases, the warm retaining ability increases. 3. The qmax value has no correlation with mixing ratio of resin but the increase of the qmax value has correlation with the increase of resin concentration. In the end, the effect of it promotes cool sense. 4. The result of multiple regression analysis for effect of physical property according to the concentration of resin to the qmax value revealed as below. As he weight and thickness increase, the qmax value decrease. But, as the density and crease recovery increase, the qmax value increase.

  • PDF

퍼클로레이트의 생물학적 환원에 나이트레이트가 주는 영향 (Biological reduction of perchlorate containing high salinity)

  • 전문휘;황정원;이지희;이강훈;염익태
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.277-277
    • /
    • 2015
  • 본 연구는 퍼클로레이트의 생물학적 환원 과정에 있어서 나이트레이트의 존재가 미생물에게 어떤 영향을 미치는지를 실험을 통해서 알아보고 적절한 모델링 접근을 통하여 나이트레이트의 퍼클로레이트 환원에 대한 저해의 정량적 분석을 위한 요소들을 도출하기 위해 수행되었다. 100mL 합성폐수를 포함하는 플라스크를 이용한 실험이 수행되었고, 유일 탄소원으로 아세트산나트륨이 사용되었고, 전자수용체로는 퍼클로레이트와 나이트레이트가 사용되었다. 먼저 퍼클로레이트와 나이트레이트 각각을 단일전자수용체로서 넣은 실험을 진행하였다. 퍼클로레이트의 동역학계수 qmax, Ks, Y, b값은 각각 0.9(mgClO4-/mgMLSSday), 42.28(mgClO4-/L), 0.382(mgClO4-/mgMLSS), 0.05(day-1)로 계산되었다. 그리고 나이트레이트의 동역학 계수 qmax, Ks, Y, b값은 각각 13.81(mgNO3-/mgMLSSday), 239.78(mgNO3-/L), 0.275(mgNO3-/mgMLSS), 0.05(day-1)로 계산되었다. 나이트레이트와 퍼클로레이트를 동시에 넣었을 경우에는 나이트레이트의 동역학 계수는 qmax, Ks, Y, b 값은 각각 13.72(mgClO4-/mgMLSSday), 235.64(mgClO4-/L), 0.263(mgClO4-/mgMLSS), 0.05(day-1)로 큰차이 없었으나, 퍼클로레이트의 경우에는 qmax, Ks, Y, b값은 각각 0.6(mgClO4-/ mgMLSSday), 42.24(mgClO4-/L), 0.393(mgClO4-/mgMLSS), 0.05(day-1)로 qmax값은 감소하였고, Y값은 증가하는 모습을 보임으로써, 나이트레이트의 존재가 퍼클로레이트의 환원을 저해시키는 것을 확인할 수 있었다.

  • PDF

한지와 레이온 복합사 편성물의 물성 (The Physical Properties of Knitted Fabric with Hanji/Rayon)

  • 김수미;송화순
    • 한국의류학회지
    • /
    • 제37권2호
    • /
    • pp.151-158
    • /
    • 2013
  • This study presents basic knitted fabric data on the use of ply yarn with rayon yarn and eco-friendly/high-valued Hanji yarn. Physical properties (gauge, thickness, burst strength, air permeability, stiffness, Qmax, dimensional stability and surface image) of Hanji 100%, rayon 100% and Hanji/rayon 50:50 knitted fabrics are investigated. The results are as follows. Course direction of gauge decrease in the following order: rayon 100% > Hanji/rayon 50/50 > Hanji 100%. In addition wale direction of gauge decrease in the following order: Hanji 100% > Hanji/rayon 50/50 > rayon 50/50. Thickness and air permeability decrease in the following order: Hanji 100% > Hanji/rayon 50/50 > rayon 100%. Burst strength decrease in the following order: rayon 100% > Hanji 100% > Hanji/rayon 50/50. Stiffness and Qmax decrease in the following order: rayon 100% > Hanji/rayon 50/50 > Hanji 100%. Laundry for dimensional stability is knitted fabric with Hanji/rayon 50/50 than rayon 100% and Hanji 100% improved using neutral detergent and stable at $20^{\circ}C$. From surface image observation, the cracks of Hanji 100% and fibrils of rayon 100% decrease when using knitted fabric with Hanji/rayon 50/50.

PET직물의 감량율과 직물구조인자에 따른 열적 쾌적성 변화에 관한 연구 (A Study on the Thermal Comfort to the Weight Reduction Rate and Fabric Structural Parameters of PET Fabrics)

  • 이희준;이민수;김승진;조대현;김태훈
    • 한국의류학회지
    • /
    • 제22권7호
    • /
    • pp.816-825
    • /
    • 1998
  • This study surveys the thermal property and air permeability to the weight reduction rate of PET fabrics. For this purpose, 12 kinds of satin and 18 kinds of plain weave fabrics are prepared with change of the physical properties such as weft yarn count, t.p.m. and density. The weight reduction rate was 0%, 12%, 25% and 30%. The warm/cool feeling(Qmax), thermal insulating value(T.I.V.) and thermal conductivity(K) were measured by KES-F7 System and discussed in relation with the weight reduction rate, weft yarn linear density, t.p.m., weft density of fabric and weave structure.

  • PDF

냉감 소재를 활용한 밀착형 여성 스포츠 상의의 착용쾌적성 평가 (Evaluation of the Wear Comfort of Women's Fitted Sports T-shirts Made from Cool-Touch Fabrics)

  • 김소영;최지영;이희란;홍경희
    • 한국의류학회지
    • /
    • 제41권5호
    • /
    • pp.929-938
    • /
    • 2017
  • This research investigated the effects of cool touch fabrics on thermo-regulating physical properties and subjective evaluation using a 3D fitted women's T-shirts in wear test. Qmax, clothing microclimate, microclimate wettedness, thermogram and subjective vote were observed during rest-right after an exercise-rest protocol. As a result, there was no single determining physical variable to explain the reasons of cool sensations of T-shirts made of cool touch fabric across the entire protocol. Qmax could partly predict a wear sensation at the initial stage when only insensible perspiration was presented. Simultaneous observation of temperature/humidity gradient understand from the inside to the outside of the clothing layer or microclimate wettedness calculated using vapor pressure were helpful to figure out the performance of cool touch fabric, especially at the later stage of the protocol when sweating was excessive. It was especially difficult to connect thermo-regulating physical variables to the subjective evaluation during transient conditions such as 'right after exercise' stage. It is necessary to measure the amount of heat and moisture transferred from the skin to the outside of clothing along with the physical properties measured in this study to understand the detailed mechanisms of why a cool sensation is evoked from tight fitting T-shirts made of newly developed cool touch fabrics.

뉴런 MOS 임계 게이트를 갖는 2중 패스-트랜지스터 논리를 이용한 4치 논리 게이트 설계 (Design of Quaternary Logic gate Using Double Pass-transistor Logic with neuron MOS Threshold gate)

  • 박수진;윤병희;김흥수
    • 전기전자학회논문지
    • /
    • 제8권1호
    • /
    • pp.33-38
    • /
    • 2004
  • 다치 논리 패스 게이트는 다치 논리를 구성하기 위한 중요한 소자이다. 본 논문에서는, 뉴런 $MOS({\nu}MOS)$ 임계 게이트를 갖는 2중 패스-트랜지스터 논리를 이용하여 4치 MIN(QMIN)/negated MIN(QNMIN) 게이트 그리고 4치 MAX(QMAX)/negated MAX(QNMAX) 게이트를 설계하였다. DPL은 입력 캐패시턴스의 증가 없이 게이트 속도를 향상 시켰다. 또한 대칭 배열과 2중 전송 특성을 갖는다. 임계 게이트는 ${\nu}MOS$ 다운 리터럴 회로(DLC)로 구성 된다. 제안된 게이트는 다양한 다치 임계 전압을 실현할 수 있다. 본 논문에서, 회로는 3V의 전원 전압을 사용하였고 0.35um N-Well 2-poly 4-metal CMOS 공정의 파라메터를 사용하였으며 모든 모의 실험은 HSPICE를 이용하였다.

  • PDF

Is the Neutrophil-Lymphocyte Ratio an Indicator of Progression in Patients with Benign Prostatic Hyperplasia?

  • Tanik, Serhat;Albayrak, Sebahattin;Zengin, Kursad;Borekci, Hasan;Bakirtas, Hasan;Imamoglu, M. Abdurrahim;Gurdal, Mesut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6375-6379
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate inflammation parameters and assess the utility of the neutrophil-lymphocyte ratio (NLR) as a simple and readily available predictor for clinical disease activity in patients with nenign prostate hyperplasia BPH. We also aimed to investigate the relationship between inflammatory parameters with ${\alpha}$-blocker therapy response, and evaluate the potential association between NLR and the progression of benign prostatic hyperplasia (BPH). Materials and Methods: We examined 320 consecutive patients (July 2013-December 2013) admitted to our outpatient clinic with symptoms of the lower urinary tract at Bozok University. The mean age was 60 (range, 51-75) years. Complete blood count (CBC), prostate-specific antigen (PSA), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were assessed. Correlations between PSA, CRP, ESR, prostate volume, International Prostate Symptom Score (IPPS), maximum urinary flow rate (Qmax), and NLR were assessed statistically. Patients were divided into two groups: high and low risk of progression. Results: NLR was positively correlated with IPSS (p=0.001, r=0.265), PSA (p=0.001, r=0.194), and negatively correlated with Qmax (p<0.001, r=-0.236). High-risk patients a had a higher NLR compared with low-risk patients, based on IPSS (p<0.001), PSA (p=0.013), and Qmax (p<0.001); however, there were no significant differences between the groups in terms of age (p>0.05), and prostate volume (p>0.05). Conclusions: NLR can predict BPH progression. We propose that increased inflammation is negatively associated with clinical status in BPH patients and suggest that NLR can give information along with LUTS severity which may be used as a readikly accessible marker for patient follow-up.

여름철 냉감성 의류소재 개발을 위한 비스코스 레이온 중심의 직물 제조 및 PCM 가공 (Preparation of Rayon Filament based Woven Fabric and PCM Treatment for Developing Cool Touch Summer Clothing Material)

  • 홍경화
    • 한국의류산업학회지
    • /
    • 제16권2호
    • /
    • pp.326-332
    • /
    • 2014
  • To develop cool touch feeling fabrics for summer clothing material, it was manufactured several compositions of woven fabrics, having rayon multi-filament yarn (non-twisted) as warp and various kinds of yarn, such as viscose rayon multi-filament yarn (twisted), tencel$^{(R)}$ spun yarn, PET high absorbance quick dry filament yarn, and PET based rayon-like yarn, as weft. After preparing the fabrics, basic properties of the fabrics were investigated, such as air-permeability, tensile strength, absorption rate, drying rate, etc. Also, surface warm / cool sensations of the woven fabrics were assessed by Qmax Warm / Cool Touch Tester. It was observed that the fabrics composed of viscose rayon multi-filament yarn (warp) and PET high absorbance quick dry filament yarn (weft) showed excellent surface cool touch sensation-the highest Qmax value. This is because the fabric having flat shaped PET high absorbance quick dry filament shows the largest contact area with Qmax measuring plate. And, the fabric also showed superior high absorbance and quick dry property as expected. In addition, we treated phase change material (PCM) on the surface of the fabric composed of viscose rayon multi-filament yarn (warp) and PET high absorbance quick dry filament yarn(weft) to improve the cool touch feeling. However, the surface cool touch feeling was impaired by resin treated with PCM during the finishing process.

스포츠웨어용 투습방수직물의 열·수분이동 특성에 관한 연구 (A Study on the Heat and Moisture Transport Properties of Vapor-Permeable Waterproof Finished Fabrics for Sports Wear)

  • 손부현;김진아;권오경
    • 한국의류산업학회지
    • /
    • 제2권3호
    • /
    • pp.220-226
    • /
    • 2000
  • This study was to determine the characteristics of vapor-permeable waterproof finished fabric by the coating method. 4 different kinds of coating fabrics (A : wet, porous, polyurethane, B : dry, no porous, polyurethane, C : shape memory polyurethane and D : dry, porous polyurethane) were used, which were developed recently With this sample, moisture transport rate ($40^{\circ}C$, 45%RH & $40^{\circ}C$, 95%RH), changes of coating side's shape by washing times, water repellency rate, contracted length, qmax, heat conductivity, heat keeping rate, heat keeping rate with cotton, heat keeping rate on humidity temperature and humidity within clothing etc. were checked. And it was done in a climate chamber under $20{\pm}2^{\circ}C$, $65{\pm}5%RH$. The results of this study were as follow; In the moisture vapor transmission of sample B and C increased on high temperature and high humidity while sample A and D decreased, on this condition. Qmax rate had high relation with ground fabric's surface properties and the order was A>C>D>B. Heat conductivity had high relation with thickness and surface properties. Heat keeping rates on sweat condition showed around half percents of heat keeping rates on normal condition, but had no relation with moisture vapor transport rate. Changes of the fabric's properties by washing times were different in accordance with the construction of fabrics and the coating resin. Sample C had tow heat keeping rate on the high temperature and humidity and high heat keeping rate on the low temperature and humidity Moisture transport rate of vapor-permeable waterproof finished fabrics had high relation with the properties of ground fabrics on low humidity condition, but on the high humidity condition, it was highly related with the properties of coating resin.

  • PDF