• 제목/요약/키워드: QS

검색결과 234건 처리시간 0.018초

품질인증시스템과 6시그마의 통합적 추진에 관한 연구 (A Study on the Integrated Implementation of Quality Certification Systems and Six Sigma)

  • 김진규
    • 산업경영시스템학회지
    • /
    • 제23권57호
    • /
    • pp.63-76
    • /
    • 2000
  • In today's competitive, market-driven world, a company's survival rests in its ability to provide quality performance products accompanied by total customer satisfaction. To satisfy the needs of customers, companies strive for defect free performances. This requires companies establish an integrated quality management system based on ISO 9000, ISO 14000, QS-9000, AS-9000, TL-9000, 100 PPM, and six sigma. This paper suggests that how to integrate implementation of quality certification systems and six sigma is an important approach in the continuous quality improvement, and six sigma efforts have become one of the key success approach. Through the various survey of total quality management system approach, it is intended to provide a chance to benchmark or give a cue on how to conduct the quality management innovation.

  • PDF

고밀도, 등방성 탄소의 제조에 관한 연구 (Preparation of Isotropic Carbon with High Density)

  • 오종기;이선우;박광원
    • 한국세라믹학회지
    • /
    • 제28권11호
    • /
    • pp.908-916
    • /
    • 1991
  • The characteristics of the carbonized and calcined products made from coal tar pitch coke and coal tar pitch, were investigated in the aspect of the manufacture of isotropic graphite with high density. The mesophase from the pitch was rapidly formed at higher heat-treatment temperature between 410$^{\circ}C$ and 450$^{\circ}C$, where the insolubes in the pitch accelerated the rate of nucleation and growth of the mesophase. The benzene insolubles and the quinoline insolubes were increased as the heat treatment temperature and the heat-treatment time increased. The ratio of benzene insolubles and quinoline solubles (BI/QS) was decreased as the heat-treatment temperature was higher and maintained to be nearly constant regardless of heat-treatment time at fixed heat treatment temperature. The bulk density of the calcined carbon was linearly proportional to the ratio of quinoline solubes to volatile matter in the green coke. Anisotropic ratio of electrical resistance was measured to be between 0.98 and 1.10.

  • PDF

심전도 데이터 압축 알고리즘의 성능개선에 관한 연구 (A Study on Performance Improvement of ECG Data Compression Algorithm)

  • 이병채;황선철;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.163-170
    • /
    • 1990
  • In this paper, fast Fourier transform and fast Walsh transform algorithm are studied for ECG data compression. ECG data-12 bit samples digitized at 480 samples-are segmented into QRS complexes and 50 intervals by di%ital derivative filter, which used for detection of QS width and difrerenre compressed in Fourler or welsh domain. And also the existing techniques for data compression-TP, MTP, CORTES, AZTEC, MCORTES, which have not been evaluated with a common measurement of goodness, were processed to get absolute terms of values in the same condition.

  • PDF

4 중 안정성 일체형 메커니즘의 설계, 해석 및 제작 (Design, Simulation and Fabrication of a Quadstable Monolithic Mechanism)

  • 한정삼
    • 대한기계학회논문집A
    • /
    • 제31권5호
    • /
    • pp.617-624
    • /
    • 2007
  • This paper presents a novel quadstable monolithic mechanism (QsMM) which provides four stable equilibrium positions within its operation range. The quadstable mechanism has been realized from the use of both X- and Y-directional bistable structures which use curved snapping beams. A millimeter-scale brass mechanism was fabricated by ultra-precision milling to test the quadstability and the displacement-load behavior, and the prototype clearly demonstrated four distinct stable positions in its millimeter-scale planar operation. We discuss the design concept, finite element simulation for static and transient responses, fabrication by ultra-precision milling, and experimental measurement of the proposed quadstable mechanism.

심방중격결손증의 외과적 고찰 (Clinical evaluation of atrial septal defect)

  • 김현순;서경필
    • Journal of Chest Surgery
    • /
    • 제16권4호
    • /
    • pp.511-517
    • /
    • 1983
  • For the purpose of clinical analysis of secundum atrial septal defect, the patients with atrial septal defect operated on during the period from Aug. 1959 to Aug. 1983 were analysed. The age of the patients was ranged from 3 months to 60 years and there were 132 males [45.3%] patients and 145 female patients [54.6%] in this series. The most frequent type was oval type defect in 219 [86.9%]. The PAPVC were present in 7 patients of high defect group. Clinical analysis revealed 53 patients [19.9%] were asymptomatic. The QP/QS above than 3.61 were 45 patients and less than 1.5 were 24 patients. The pulmonary artery pressure was 10 to 100 mmHg. The majority of the defects were closed in primary suture and closed with a Dacron patch in 19 patients. The postoperative complications occurred in 35 patients [13.1%] and the most frequent complication was wound problem which was present in 10 patients. The hospital mortality rate was 1.6%.

  • PDF

폐동맥으로 유입되는 관상동정맥루수술치험 1례 (Coronary Arteriovenous Fistula Draining into the Main Pulmonary Artery)

  • 김학제
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.143-147
    • /
    • 1988
  • Congenital coronary arteriovenous fistula is a communication of a coronary artery with one of the atria, ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. We had a successful surgical experience with 63 year-old-female patient who complained substernal chest pain on exertion for 8 years. On auscultation, a continuous murmur was heard at the left second to third intercostal space along the left sternal border. The right cardiac catheterization was revealed to 4% oxygen step up between right ventricle to main pulmonary artery, and Qp/Qs was 1.3:1. The selective coronary arteriography showed markedly tortuous dilated vessel which originated from left coronary artery draining into the main pulmonary artery. The operation performed to mid portion of tortuous and dilated fistula by multiple ligation with 3-0 Mersilene and suture ligation with pledgetted 3-0 Prolene on distal draining site, Postoperative course were uneventful without any symptoms and complications.

  • PDF

송전용 자기재 애자의 알루미나 함유량에 따른 특성 연구 (Study according to additional Alumina of Porcelain Insulator for T/L)

  • 최인혁;최장현;신태우;이동일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.65-68
    • /
    • 2005
  • 알루미나 함유량의 변화에 따른 국산 2001년, 2004년 애자와 외국산 2000년도 36,000lbs 불소켓형 현수애자에 대해 물성 분석을 실시하였다. 그 결과 2001년도 자기애자의 알루미나 함유량을 17%로 하고 2004년도 알루미나 함유량이 20%로 하였을 경우 자기 애자의 기계적 특성은 10% 정도 향상되었다. 그리고 2001년도에 제조한 애자의 자기 상대밀도는 이론밀도의 96%에 도달하였으나 2004년도에 제조한 애자의 상대 밀도는 이론민도의 98%에 도달하였으면 애자의 균일성을 나타내는 Qs 값은 5.01로 높게 나타났다.

  • PDF

우리나라 인증제도의 현황과 개선방안 (A Present Views and Improvement policy of the Certification System in Korea)

  • 조남호;우태희;한우철
    • 산업경영시스템학회지
    • /
    • 제22권51호
    • /
    • pp.211-220
    • /
    • 1999
  • The purpose of this study is the necessity of collaboration, equilibrium or the differences of examination items about certification system which is focused on products, such as KS, formal approval, and ISO 9000 family, QS 9000, etc, for Quality management system. We make expert group control this problem. Also we make examination items to be united. And the differences of certification body and personnel necessary is dissolved by proper instruction. Examination process and corrective maintenance should be improved by clarity, fairness and reliability. Problems through preparation for certification and certified company should be focused on reform of consciousness of top management and continuous instruction. And desirable solution for mutual certification problem and others should be found by information interchange system of international cooperation.

  • PDF

HYPERSTABILITY OF A SUM FORM FUNCTIONAL EQUATION RELATED DISTANCE MEASURES

  • Lee, Young Whan
    • 충청수학회지
    • /
    • 제33권1호
    • /
    • pp.147-156
    • /
    • 2020
  • The functional equation related to a distance measure f(pr, qs) + f(ps, qr) = M(r, s)f(p, q) + M(p, q)f(r, s) can be generalized a sum form functional equation as follows $${\frac{1}{n}}{\sum\limits_{i=0}^{n-1}}f(P{\cdot}{\sigma}_i(Q))=M(Q)f(P)+M(P)f(Q)$$ where f, g is information measures, P and Q are the set of n-array discrete measure, and σi is a permutation for each i = 0, 1, ⋯, n-1. In this paper, we obtain the hyperstability of the above type functional equation.

SOI 마이크로머시닝 공정을 이용한 Suspended-type 박막공진기의 제작 및 특성평가 (Fabrication and Characterization of Suspended-type Thin Film Resonator Using SOI-Micromachining Process)

  • 주병권;김현호;이시형;이전국;김수원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권6호
    • /
    • pp.303-306
    • /
    • 2001
  • STFR were fabricated on the floating membrane which was formed by SOI-micromachining process. The floating membranes having a thickness range of $3{\sim}15{\mu}m$ could be simply formed by micromachining the directly-bonded and thinned SOI substrate. The STFR device fabricated on the $15{\mu}m$-thick membrane showed resonance frequency of fr = 1.65 GHz, coupling coefficient of Keff2 = 2.4 %, and series and parallel quality factors of Qs = 91.7 and Qp = 87.7, respectively.

  • PDF